메뉴 건너뛰기




Volumn 5, Issue 2, 2014, Pages 93-101

Computer-aided surgery does not increase the accuracy of dorsal pedicle screw placement in the thoracic and lumbar spine: A retrospective analysis of 2,003 pedicle screws in a level i trauma center

Author keywords

computer assisted pedicle screw placement; computer navigation; image based guidance; pedicle screw; spine

Indexed keywords

ACCURACY; ADOLESCENT; ADULT; AGED; ARTICLE; BODY MASS; COMPUTER ASSISTED SURGERY; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FEMALE; HUMAN; INTERMETHOD COMPARISON; LAMINECTOMY; LUMBAR SPINE; MAJOR CLINICAL STUDY; MALE; MEDICAL DEVICE COMPLICATION; NEUROLOGIC DISEASE; PEDICLE SCREW; PERFORATION; POSTERIOR SPINE FUSION; POSTOPERATIVE HEMORRHAGE; POSTOPERATIVE INFECTION; PRIORITY JOURNAL; REOPERATION; RETROSPECTIVE STUDY; SPINE STABILIZATION; SURGICAL NAVIGATION SYSTEM; THORACIC SPINE; VASCULAR DISEASE; WORK EXPERIENCE; WOUND HEALING IMPAIRMENT;

EID: 84986544938     PISSN: 21925682     EISSN: 21925690     Source Type: Journal    
DOI: 10.1055/s-0034-1396430     Document Type: Article
Times cited : (26)

References (26)
  • 1
    • 0014442736 scopus 로고
    • Reduction of severe spondylolisthesis in children
    • Harrington P. R., Tullos H. S. Reduction of severe spondylolisthesis in children. South Med J: 1969; 62 1 1 7
    • (1969) South Med J , vol.62 , Issue.1 , pp. 1-7
    • Harrington, P.R.1    Tullos, H.S.2
  • 2
    • 0022625438 scopus 로고
    • Internal fixation of the lumbar spine with pedicle screw plating
    • Roy-Camille R., Saillant G., Mazel C. Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res: 1986; 203 7 17
    • (1986) Clin Orthop Relat Res , Issue.203 , pp. 7-17
    • Roy-Camille, R.1    Saillant, G.2    Mazel, C.3
  • 3
    • 0023790873 scopus 로고
    • Spinal pedicle fixation: Reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement
    • Weinstein J. N., Spratt K. F., Spengler D., Brick C., Reid S. Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine (Phila Pa 1976): 1988; 13 9 1012 1018
    • (1988) Spine (Phila Pa 1976) , vol.13 , Issue.9 , pp. 1012-1018
    • Weinstein, J.N.1    Spratt, K.F.2    Spengler, D.3    Brick, C.4    Reid, S.5
  • 4
    • 82155173291 scopus 로고    scopus 로고
    • Clinically relevant complications related to pedicle screw placement in thoracolumbar surgery and their management: A literature review of 35,630 pedicle screws
    • Gautschi O. P., Schatlo B., Schaller K., Tessitore E. Clinically relevant complications related to pedicle screw placement in thoracolumbar surgery and their management: a literature review of 35,630 pedicle screws. Neurosurg Focus: 2011; 31 4 E8
    • (2011) Neurosurg Focus , vol.31 , Issue.4 , pp. E8
    • Gautschi, O.P.1    Schatlo, B.2    Schaller, K.3    Tessitore, E.4
  • 5
    • 77952369629 scopus 로고    scopus 로고
    • Complications of pedicle screw fixation in scoliosis surgery: A systematic review
    • Hicks J. M., Singla A., Shen F. H., Arlet V. Complications of pedicle screw fixation in scoliosis surgery: a systematic review. Spine (Phila Pa 1976): 2010; 35 11 E465 E470
    • (2010) Spine (Phila Pa 1976) , vol.35 , Issue.11 , pp. E465-E470
    • Hicks, J.M.1    Singla, A.2    Shen, F.H.3    Arlet, V.4
  • 7
    • 84873576215 scopus 로고    scopus 로고
    • Worldwide survey on the use of navigation in spine surgery
    • Hartl R., Lam K. S., Wang J., et al. Worldwide survey on the use of navigation in spine surgery. World Neurosurg: 2013; 79 1 162 172
    • (2013) World Neurosurg , vol.79 , Issue.1 , pp. 162-172
    • Hartl, R.1    Lam, K.S.2    Wang, J.3
  • 8
    • 77955574857 scopus 로고    scopus 로고
    • Can computer-assisted surgery reduce the effective dose for spinal fusion and sacroiliac screw insertion
    • Kraus M. D., Krischak G., Keppler P., Gebhard F. T., Schuetz U. H. Can computer-assisted surgery reduce the effective dose for spinal fusion and sacroiliac screw insertion? Clin Orthop Relat Res: 2010; 468 9 2419 2429
    • (2010) Clin Orthop Relat Res , vol.468 , Issue.9 , pp. 2419-2429
    • Kraus, M.D.1    Krischak, G.2    Keppler, P.3    Gebhard, F.T.4    Schuetz, U.H.5
  • 9
    • 0034061781 scopus 로고    scopus 로고
    • Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
    • Amiot L. P., Lang K., Putzier M., Zippel H., Labelle H. Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine (Phila Pa 1976): 2000; 25 5 606 614
    • (2000) Spine (Phila Pa 1976) , vol.25 , Issue.5 , pp. 606-614
    • Amiot, L.P.1    Lang, K.2    Putzier, M.3    Zippel, H.4    Labelle, H.5
  • 10
    • 0142120120 scopus 로고    scopus 로고
    • Improved accuracy of computer-assisted cervical pedicle screw insertion
    • (3, Suppl)
    • Kotani Y., Abumi K., Ito M., Minami A. Improved accuracy of computer-assisted cervical pedicle screw insertion. J Neurosurg: 2003; 99 (3, Suppl): 257 263
    • (2003) J Neurosurg , vol.99 , pp. 257-263
    • Kotani, Y.1    Abumi, K.2    Ito, M.3    Minami, A.4
  • 11
    • 0029421473 scopus 로고
    • Computer-assisted spine surgery: A technique for accurate transpedicular screw fixation using CT data and a 3-D optical localizer
    • Lavallée S., Sautot P., Troccaz J., Cinquin P., Merloz P. Computer-assisted spine surgery: a technique for accurate transpedicular screw fixation using CT data and a 3-D optical localizer. J Image Guid Surg: 1995; 1 1 65 73
    • (1995) J Image Guid Surg , vol.1 , Issue.1 , pp. 65-73
    • Lavallée, S.1    Sautot, P.2    Troccaz, J.3    Cinquin, P.4    Merloz, P.5
  • 12
    • 35948933032 scopus 로고    scopus 로고
    • Fluoroscopy-based navigation system in spine surgery
    • Merloz P., Troccaz J., Vouaillat H., et al. Fluoroscopy-based navigation system in spine surgery. Proc Inst Mech Eng H: 2007; 221 7 813 820
    • (2007) Proc Inst Mech Eng H , vol.221 , Issue.7 , pp. 813-820
    • Merloz, P.1    Troccaz, J.2    Vouaillat, H.3
  • 13
    • 33846683025 scopus 로고    scopus 로고
    • Pedicle screw placement accuracy: A meta-analysis
    • Kosmopoulos V., Schizas C. Pedicle screw placement accuracy: a meta-analysis. Spine (Phila Pa 1976): 2007; 32 3 E111 E120
    • (2007) Spine (Phila Pa 1976) , vol.32 , Issue.3 , pp. E111-E120
    • Kosmopoulos, V.1    Schizas, C.2
  • 14
    • 75049084141 scopus 로고    scopus 로고
    • Image-guided spine surgery: State of the art and future directions
    • Tjardes T., Shafizadeh S., Rixen D., et al. Image-guided spine surgery: state of the art and future directions. Eur Spine J: 2010; 19 1 25 45
    • (2010) Eur Spine J , vol.19 , Issue.1 , pp. 25-45
    • Tjardes, T.1    Shafizadeh, S.2    Rixen, D.3
  • 15
    • 0026657201 scopus 로고
    • Pedicle screw instrumentation for thoracolumbar burst fractures and fracture-dislocations
    • (8, Suppl)
    • Carl A. L., Tromanhauser S. G., Roger D. J. Pedicle screw instrumentation for thoracolumbar burst fractures and fracture-dislocations. Spine (Phila Pa 1976): 1992; 17 (8, Suppl): S317 S324
    • (1992) Spine (Phila Pa 1976) , vol.17 , pp. S317-S324
    • Carl, A.L.1    Tromanhauser, S.G.2    Roger, D.J.3
  • 16
    • 84855193778 scopus 로고    scopus 로고
    • Factors affecting the accurate placement of percutaneous pedicle screws during minimally invasive transforaminal lumbar interbody fusion
    • Kim M. C., Chung H. T., Cho J. L., Kim D. J., Chung N. S. Factors affecting the accurate placement of percutaneous pedicle screws during minimally invasive transforaminal lumbar interbody fusion. Eur Spine J: 2011; 20 10 1635 1643
    • (2011) Eur Spine J , vol.20 , Issue.10 , pp. 1635-1643
    • Kim, M.C.1    Chung, H.T.2    Cho, J.L.3    Kim, D.J.4    Chung, N.S.5
  • 17
    • 84878198364 scopus 로고    scopus 로고
    • CT-navigation versus fluoroscopy-guided placement of pedicle screws at the thoracolumbar spine: Single center experience of 4,500 screws
    • Waschke A., Walter J., Duenisch P., Reichart R., Kalff R., Ewald C. CT-navigation versus fluoroscopy-guided placement of pedicle screws at the thoracolumbar spine: single center experience of 4,500 screws. Eur Spine J: 2013; 22 3 654 660
    • (2013) Eur Spine J , vol.22 , Issue.3 , pp. 654-660
    • Waschke, A.1    Walter, J.2    Duenisch, P.3    Reichart, R.4    Kalff, R.5    Ewald, C.6
  • 18
    • 68349104323 scopus 로고    scopus 로고
    • Image-guided pedicle screw insertion accuracy: A meta-analysis
    • Tian N. F., Xu H. Z. Image-guided pedicle screw insertion accuracy: a meta-analysis. Int Orthop: 2009; 33 4 895 903
    • (2009) Int Orthop , vol.33 , Issue.4 , pp. 895-903
    • Tian, N.F.1    Xu, H.Z.2
  • 19
    • 77951143798 scopus 로고    scopus 로고
    • Functional outcome of computer-assisted spinal pedicle screw placement: A systematic review and meta-analysis of 23 studies including 5,992 pedicle screws
    • Verma R., Krishan S., Haendlmayer K., Mohsen A. Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screws. Eur Spine J: 2010; 19 3 370 375
    • (2010) Eur Spine J , vol.19 , Issue.3 , pp. 370-375
    • Verma, R.1    Krishan, S.2    Haendlmayer, K.3    Mohsen, A.4
  • 20
    • 80052564997 scopus 로고    scopus 로고
    • Pedicle screw insertion accuracy with different assisted methods: A systematic review and meta-analysis of comparative studies
    • Tian N. F., Huang Q. S., Zhou P., et al. Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies. Eur Spine J: 2011; 20 6 846 859
    • (2011) Eur Spine J , vol.20 , Issue.6 , pp. 846-859
    • Tian, N.F.1    Huang, Q.S.2    Zhou, P.3
  • 21
    • 0031438992 scopus 로고    scopus 로고
    • Accuracy of pedicle screw insertion: A prospective CT study in 30 low back patients
    • Laine T., Mäkitalo K., Schlenzka D., Tallroth K., Poussa M., Alho A. Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients. Eur Spine J: 1997; 6 6 402 405
    • (1997) Eur Spine J , vol.6 , Issue.6 , pp. 402-405
    • Laine, T.1    Mäkitalo, K.2    Schlenzka, D.3    Tallroth, K.4    Poussa, M.5    Alho, A.6
  • 22
    • 0025267440 scopus 로고
    • Accuracy of pedicular screw placement in vivo
    • Gertzbein S. D., Robbins S. E. Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976): 1990; 15 1 11 14
    • (1990) Spine (Phila Pa 1976) , vol.15 , Issue.1 , pp. 11-14
    • Gertzbein, S.D.1    Robbins, S.E.2
  • 23
    • 84861304427 scopus 로고    scopus 로고
    • Accuracy of pedicle screw placement: A systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques
    • Gelalis I. D., Paschos N. K., Pakos E. E., et al. Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J: 2012; 21 2 247 255
    • (2012) Eur Spine J , vol.21 , Issue.2 , pp. 247-255
    • Gelalis, I.D.1    Paschos, N.K.2    Pakos, E.E.3
  • 25
    • 0025879589 scopus 로고
    • Complications of the variable screw plate pedicle screw fixation
    • West J. L. III, Ogilvie J. W., Bradford D. S. Complications of the variable screw plate pedicle screw fixation. Spine (Phila Pa 1976): 1991; 16 5 576 579
    • (1991) Spine (Phila Pa 1976) , vol.16 , Issue.5 , pp. 576-579
    • Ogilvie, J.W.1    Bradford, D.S.2
  • 26
    • 84971580244 scopus 로고
    • Absence of evidence is not evidence of absence
    • Altman D. G., Bland J. M. Absence of evidence is not evidence of absence. BMJ: 1995; 311 7003 485
    • (1995) BMJ , vol.311 , Issue.7003 , pp. 485
    • Altman, D.G.1    Bland, J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.