메뉴 건너뛰기




Volumn 44, Issue 11, 2013, Pages 1486-1492

Integration of fluoroscopy-based guidance in orthopaedic trauma surgery - A prospective cohort study

Author keywords

C arm; Computer navigation; Fluoroscopy; Fracture; Image based guidance; Intra operative imaging; Trauma

Indexed keywords

ADULT; ANKLE INJURY; ARTICLE; BONE IMPLANT; CLINICAL ARTICLE; COHORT ANALYSIS; FEMALE; FLUOROSCOPY; FLUOROSCOPY SYSTEM; FOOT INJURY; HAND INJURY; HUMAN; INTEGRATION; MALE; MUSCULOSKELETAL INJURY; OPERATION DURATION; ORTHOPEDIC SURGERY; OSTEOSYNTHESIS; OUTCOME ASSESSMENT; PELVIS INJURY; PRIORITY JOURNAL; PSEUDARTHROSIS; QUESTIONNAIRE; SHOULDER INJURY; SPINE INJURY; TREATMENT FAILURE; WORKFLOW; WRIST INJURY;

EID: 84885310951     PISSN: 00201383     EISSN: 18790267     Source Type: Journal    
DOI: 10.1016/j.injury.2013.02.008     Document Type: Article
Times cited : (10)

References (22)
  • 2
    • 77955574857 scopus 로고    scopus 로고
    • Can computer-assisted surgery reduce the effective dose for spinal fusion and sacroiliac screw insertion?
    • M.D. Kraus, G. Krischak, P. Keppler, F.T. Gebhard, and U.H. Schuetz Can computer-assisted surgery reduce the effective dose for spinal fusion and sacroiliac screw insertion? Clin Orthop Relat Res 468 2010 2419 2429
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 2419-2429
    • Kraus, M.D.1    Krischak, G.2    Keppler, P.3    Gebhard, F.T.4    Schuetz, U.H.5
  • 3
    • 1442277695 scopus 로고    scopus 로고
    • Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine
    • M. Richter, T. Mattes, and B. Cakir Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine Eur Spine J 13 2004 50 59
    • (2004) Eur Spine J , vol.13 , pp. 50-59
    • Richter, M.1    Mattes, T.2    Cakir, B.3
  • 4
    • 0033562611 scopus 로고    scopus 로고
    • Radiation dose for pedicle screw insertion. Fluoroscopic method versus computer-assisted surgery
    • M. Slomczykowski, M. Roberto, P. Schneeberger, C. Ozdoba, and P. Vock Radiation dose for pedicle screw insertion. Fluoroscopic method versus computer-assisted surgery Spine (Phila Pa 1976) 24 1999 975 982
    • (1999) Spine (Phila Pa 1976) , vol.24 , pp. 975-982
    • Slomczykowski, M.1    Roberto, M.2    Schneeberger, P.3    Ozdoba, C.4    Vock, P.5
  • 8
    • 11844295948 scopus 로고    scopus 로고
    • The use of computerized navigation in the treatment of gunshot and shrapnel injury
    • R. Mosheiff, Y. Weil, A. Khoury, and M. Liebergall The use of computerized navigation in the treatment of gunshot and shrapnel injury Comput Aided Surg 9 2004 39 43
    • (2004) Comput Aided Surg , vol.9 , pp. 39-43
    • Mosheiff, R.1    Weil, Y.2    Khoury, A.3    Liebergall, M.4
  • 10
    • 77951143798 scopus 로고    scopus 로고
    • Functional outcome of computer-assisted spinal pedicle screw placement: A systematic review and meta-analysis of 23 studies including 5992 pedicle screws
    • R. Verma, S. Krishan, K. Haendlmayer, and A. Mohsen Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5992 pedicle screws Eur Spine J 19 2010 370 375
    • (2010) Eur Spine J , vol.19 , pp. 370-375
    • Verma, R.1    Krishan, S.2    Haendlmayer, K.3    Mohsen, A.4
  • 11
    • 67649791453 scopus 로고    scopus 로고
    • Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure
    • J. Zwingmann, G. Konrad, E. Kotter, N.P. Sudkamp, and M. Oberst Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure Clin Orthop Relat Res 467 2009 1833 1838
    • (2009) Clin Orthop Relat Res , vol.467 , pp. 1833-1838
    • Zwingmann, J.1    Konrad, G.2    Kotter, E.3    Sudkamp, N.P.4    Oberst, M.5
  • 14
    • 33747588073 scopus 로고    scopus 로고
    • Limb malalignment and functional outcome after antegrade versus retrograde intramedullary nailing in distal femoral fractures
    • K.H. Salem, D. Maier, P. Keppler, L. Kinzl, and F. Gebhard Limb malalignment and functional outcome after antegrade versus retrograde intramedullary nailing in distal femoral fractures J Trauma 61 2006 375 381
    • (2006) J Trauma , vol.61 , pp. 375-381
    • Salem, K.H.1    Maier, D.2    Keppler, P.3    Kinzl, L.4    Gebhard, F.5
  • 15
    • 15444375505 scopus 로고    scopus 로고
    • Post-traumatic torsional differences and functional tests following antegrade or retrograde intramedullary nailing of the distal femoral diaphysis
    • D.G. Maier, R. Reisig, P. Keppler, L. Kinzl, and F. Gebhard Post-traumatic torsional differences and functional tests following antegrade or retrograde intramedullary nailing of the distal femoral diaphysis Unfallchirurg 108 2005 109 117
    • (2005) Unfallchirurg , vol.108 , pp. 109-117
    • Maier, D.G.1    Reisig, R.2    Keppler, P.3    Kinzl, L.4    Gebhard, F.5
  • 16
    • 70350087337 scopus 로고    scopus 로고
    • Reliability of limb alignment measurement for high tibial osteotomy with a navigation system
    • J. Lutzner, A.F. Gross, K.P. Gunther, and S. Kirschner Reliability of limb alignment measurement for high tibial osteotomy with a navigation system Eur J Med Res 14 2009 447 450
    • (2009) Eur J Med Res , vol.14 , pp. 447-450
    • Lutzner, J.1    Gross, A.F.2    Gunther, K.P.3    Kirschner, S.4
  • 17
    • 33749353460 scopus 로고    scopus 로고
    • Navigated open-wedge high tibial osteotomy: Advantages and disadvantages compared to the conventional technique in a cadaver study
    • S. Hankemeier, T. Hüfner, G. Wang, D. Kendoff, J. Zeichen, and G. Zhang Navigated open-wedge high tibial osteotomy: advantages and disadvantages compared to the conventional technique in a cadaver study Knee Surg Sports Traumatol Arthrosc 14 2006 917 921
    • (2006) Knee Surg Sports Traumatol Arthrosc , vol.14 , pp. 917-921
    • Hankemeier, S.1    Hüfner, T.2    Wang, G.3    Kendoff, D.4    Zeichen, J.5    Zhang, G.6
  • 19
    • 43249128572 scopus 로고    scopus 로고
    • A comparison of optical and electromagnetic computer-assisted navigation systems for fluoroscopic targeting
    • W.M. Ricci, T.A. Russell, D.M. Kahler, L. Terrill-Grisoni, and P. Culley A comparison of optical and electromagnetic computer-assisted navigation systems for fluoroscopic targeting J Orthop Trauma 22 2008 190 194
    • (2008) J Orthop Trauma , vol.22 , pp. 190-194
    • Ricci, W.M.1    Russell, T.A.2    Kahler, D.M.3    Terrill-Grisoni, L.4    Culley, P.5
  • 20
    • 45549104166 scopus 로고    scopus 로고
    • Stereotactic CT-guided percutaneous stabilization of posterior pelvic ring fractures: A preclinical cadaver study
    • R.J. Bale, P. Kovacs, B. Dolati, C. Hinterleithner, and R.E. Rosenberger Stereotactic CT-guided percutaneous stabilization of posterior pelvic ring fractures: a preclinical cadaver study J Vasc Interv Radiol 19 2008 1093 1098
    • (2008) J Vasc Interv Radiol , vol.19 , pp. 1093-1098
    • Bale, R.J.1    Kovacs, P.2    Dolati, B.3    Hinterleithner, C.4    Rosenberger, R.E.5