메뉴 건너뛰기




Volumn 30, Issue 2, 2016, Pages 227-233

Bioelectrical impedance spectroscopy to estimate fluid balance in critically ill patients

Author keywords

Bioelectric impedance; Body weight; Critical care; Water electrolyte balance

Indexed keywords

ANTHROPOMETRY; BIOCHEMISTRY; ELECTRIC IMPEDANCE MEASUREMENT; ELECTROPHYSIOLOGY; RESUSCITATION; VENTILATION;

EID: 84961164432     PISSN: 13871307     EISSN: 15732614     Source Type: Journal    
DOI: 10.1007/s10877-015-9706-7     Document Type: Article
Times cited : (21)

References (27)
  • 2
    • 79251546295 scopus 로고    scopus 로고
    • Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality
    • PID: 20975548
    • Boyd JH, Forbes J, Nakada TA, Walley KR, Russell JA. Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality. Crit Care Med. 2011;39(2):259–65. doi:10.1097/CCM.0b013e3181feeb15.
    • (2011) Crit Care Med , vol.39 , Issue.2 , pp. 259-265
    • Boyd, J.H.1    Forbes, J.2    Nakada, T.A.3    Walley, K.R.4    Russell, J.A.5
  • 3
    • 33745081608 scopus 로고    scopus 로고
    • Comparison of two fluid-management strategies in acute lung injury
    • National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network, Wiedemann HP, Wheeler AP, Bernard GR, Thompson BT, Hayden D, deBoisblanc B, Connors AF Jr, Hite RD, Harabin AL. Comparison of two fluid-management strategies in acute lung injury. N Engl J Med. 2006;354(24):2564–75. doi:10.1056/NEJMoa062200.
    • (2006) N Engl J Med , vol.354 , Issue.24 , pp. 2564-2575
  • 4
    • 0033924376 scopus 로고    scopus 로고
    • Comparison of bioimpedance and radioisotope methods in the estimation of extracellular water volume before and after coronary artery bypass grafting operation
    • COI: 1:STN:280:DC%2BD3cvis1Oktw%3D%3D, PID: 10886261
    • Koobi T, Kahonen M, Koskinen M, Kaukinen S, Turjanmaa VM. Comparison of bioimpedance and radioisotope methods in the estimation of extracellular water volume before and after coronary artery bypass grafting operation. Clin Physiol. 2000;20(4):283–91.
    • (2000) Clin Physiol , vol.20 , Issue.4 , pp. 283-291
    • Koobi, T.1    Kahonen, M.2    Koskinen, M.3    Kaukinen, S.4    Turjanmaa, V.M.5
  • 6
    • 84870653589 scopus 로고    scopus 로고
    • Schneider AG, Baldwin I, Freitag E, Glassford N, Bellomo R. Estimation of fluid status changes in critically ill patients: fluid balance chart or electronic bed weight? J Crit Care. 2012;27(6):745 e747–712. .
    • Schneider AG, Baldwin I, Freitag E, Glassford N, Bellomo R. Estimation of fluid status changes in critically ill patients: fluid balance chart or electronic bed weight? J Crit Care. 2012;27(6):745 e747–712. doi:10.1016/j.jcrc.2011.12.017.
  • 7
    • 79960946112 scopus 로고    scopus 로고
    • Fluid balance in critically ill patients. Should we really rely on it?
    • COI: 1:STN:280:DC%2BC3MnlvVKjuw%3D%3D, PID: 21730928
    • Perren A, Markmann M, Merlani G, Marone C, Merlani P. Fluid balance in critically ill patients. Should we really rely on it? Minerva Anestesiol. 2011;77(8):802–11.
    • (2011) Minerva Anestesiol , vol.77 , Issue.8 , pp. 802-811
    • Perren, A.1    Markmann, M.2    Merlani, G.3    Marone, C.4    Merlani, P.5
  • 8
    • 0027265236 scopus 로고
    • Weight changes in critically ill patients evaluated by fluid balances and impedance measurements
    • COI: 1:STN:280:DyaK3s3nvFSgsg%3D%3D, PID: 8504655
    • Roos AN, Westendorp RG, Frolich M, Meinders AE. Weight changes in critically ill patients evaluated by fluid balances and impedance measurements. Crit Care Med. 1993;21(6):871–7.
    • (1993) Crit Care Med , vol.21 , Issue.6 , pp. 871-877
    • Roos, A.N.1    Westendorp, R.G.2    Frolich, M.3    Meinders, A.E.4
  • 9
    • 58849150742 scopus 로고    scopus 로고
    • Importance of whole-body bioimpedance spectroscopy for the management of fluid balance
    • PID: 19169022
    • Wabel P, Chamney P, Moissl U, Jirka T. Importance of whole-body bioimpedance spectroscopy for the management of fluid balance. Blood Purif. 2009;27(1):75–80. doi:10.1159/000167013.
    • (2009) Blood Purif , vol.27 , Issue.1 , pp. 75-80
    • Wabel, P.1    Chamney, P.2    Moissl, U.3    Jirka, T.4
  • 10
    • 34948909214 scopus 로고    scopus 로고
    • Bioimpedance spectroscopy for clinical assessment of fluid distribution and body cell mass
    • PID: 17644693
    • Earthman C, Traughber D, Dobratz J, Howell W. Bioimpedance spectroscopy for clinical assessment of fluid distribution and body cell mass. Nutr Clin Pract. 2007;22(4):389–405.
    • (2007) Nutr Clin Pract , vol.22 , Issue.4 , pp. 389-405
    • Earthman, C.1    Traughber, D.2    Dobratz, J.3    Howell, W.4
  • 11
    • 4644262992 scopus 로고    scopus 로고
    • The validity of bioelectrical impedance models in clinical populations
    • PID: 16215137
    • Buchholz AC, Bartok C, Schoeller DA. The validity of bioelectrical impedance models in clinical populations. Nutr Clin Pract. 2004;19(5):433–46.
    • (2004) Nutr Clin Pract , vol.19 , Issue.5 , pp. 433-446
    • Buchholz, A.C.1    Bartok, C.2    Schoeller, D.A.3
  • 13
    • 33646529157 scopus 로고    scopus 로고
    • Detection limit of methods to assess fluid status changes in dialysis patients
    • COI: 1:STN:280:DC%2BD283ksVSgsw%3D%3D, PID: 16501488
    • Kraemer M, Rode C, Wizemann V. Detection limit of methods to assess fluid status changes in dialysis patients. Kidney Int. 2006;69(9):1609–20. doi:10.1038/sj.ki.5000286.
    • (2006) Kidney Int , vol.69 , Issue.9 , pp. 1609-1620
    • Kraemer, M.1    Rode, C.2    Wizemann, V.3
  • 14
    • 33846092266 scopus 로고    scopus 로고
    • A whole-body model to distinguish excess fluid from the hydration of major body tissues
    • COI: 1:CAS:528:DC%2BD2sXmvFegtQ%3D%3D, PID: 17209181
    • Chamney PW, Wabel P, Moissl UM, Muller MJ, Bosy-Westphal A, Korth O, Fuller NJ. A whole-body model to distinguish excess fluid from the hydration of major body tissues. Am J Clin Nutr. 2007;85(1):80–9.
    • (2007) Am J Clin Nutr , vol.85 , Issue.1 , pp. 80-89
    • Chamney, P.W.1    Wabel, P.2    Moissl, U.M.3    Muller, M.J.4    Bosy-Westphal, A.5    Korth, O.6    Fuller, N.J.7
  • 15
    • 48249153186 scopus 로고
    • Intraclass correlations: uses in assessing rater reliability
    • COI: 1:STN:280:DC%2BD1cnkslSnsg%3D%3D, PID: 18839484
    • Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979;86(2):420–8.
    • (1979) Psychol Bull , vol.86 , Issue.2 , pp. 420-428
    • Shrout, P.E.1    Fleiss, J.L.2
  • 16
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • COI: 1:STN:280:DyaL287hslWqsQ%3D%3D, PID: 2868172
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–10.
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 17
    • 0030918146 scopus 로고    scopus 로고
    • Bioelectrical impedance techniques in medicine. Part II: monitoring of physiological events by impedance
    • COI: 1:STN:280:DyaK2szktVertA%3D%3D, PID: 9196885
    • Valentinuzzi ME, Morucci JP, Felice CJ. Bioelectrical impedance techniques in medicine. Part II: monitoring of physiological events by impedance. Crit Rev Biomed Eng. 1996;24(4–6):353–466.
    • (1996) Crit Rev Biomed Eng , vol.24 , Issue.4-6 , pp. 353-466
    • Valentinuzzi, M.E.1    Morucci, J.P.2    Felice, C.J.3
  • 18
    • 0032819629 scopus 로고    scopus 로고
    • Use of single-frequency bioimpedance at 50 kHz to estimate total body water in patients with multiple organ failure and fluid overload
    • COI: 1:STN:280:DyaK1MzpslemsQ%3D%3D, PID: 10470752
    • Foley K, Keegan M, Campbell I, Murby B, Hancox D, Pollard B. Use of single-frequency bioimpedance at 50 kHz to estimate total body water in patients with multiple organ failure and fluid overload. Crit Care Med. 1999;27(8):1472–7.
    • (1999) Crit Care Med , vol.27 , Issue.8 , pp. 1472-1477
    • Foley, K.1    Keegan, M.2    Campbell, I.3    Murby, B.4    Hancox, D.5    Pollard, B.6
  • 19
    • 73649190765 scopus 로고
    • Bio-electric properties of tissues. Estimation by measurement of impedance of extracellular ionic strength and intracellular ionic strength in the clinic
    • COI: 1:STN:280:DyaF387nt12nsw%3D%3D, PID: 13981120
    • Thomasset A. Bio-electric properties of tissues. Estimation by measurement of impedance of extracellular ionic strength and intracellular ionic strength in the clinic. Lyon Med. 1963;209:1325–50.
    • (1963) Lyon Med , vol.209 , pp. 1325-1350
    • Thomasset, A.1
  • 20
    • 0029825841 scopus 로고    scopus 로고
    • Estimation of total body and extracellular water in post-coronary artery bypass graft surgical patients using single and multiple frequency bioimpedance
    • COI: 1:STN:280:DyaK2s%2FnsVKjtw%3D%3D, PID: 8917032
    • Patel RV, Peterson EL, Silverman N, Zarowitz BJ. Estimation of total body and extracellular water in post-coronary artery bypass graft surgical patients using single and multiple frequency bioimpedance. Crit Care Med. 1996;24(11):1824–8.
    • (1996) Crit Care Med , vol.24 , Issue.11 , pp. 1824-1828
    • Patel, R.V.1    Peterson, E.L.2    Silverman, N.3    Zarowitz, B.J.4
  • 21
    • 0032080105 scopus 로고    scopus 로고
    • Evaluation of multifrequency bioimpedance spectroscopy for measurement of the extracellular water space in critically ill patients
    • COI: 1:CAS:528:DyaK1cXit1eitLY%3D, PID: 9569521
    • Plank LD, Monk DN, Woollard GA, Hill GL. Evaluation of multifrequency bioimpedance spectroscopy for measurement of the extracellular water space in critically ill patients. Appl Radiat Isot. 1998;49(5–6):481–3.
    • (1998) Appl Radiat Isot , vol.49 , Issue.5-6 , pp. 481-483
    • Plank, L.D.1    Monk, D.N.2    Woollard, G.A.3    Hill, G.L.4
  • 22
    • 0034037965 scopus 로고    scopus 로고
    • Bioelectrical impedance analysis in estimating nutritional status and outcome of patients with chronic obstructive pulmonary disease and acute respiratory failure
    • COI: 1:STN:280:DC%2BD3M%2Fjt1ersQ%3D%3D, PID: 10923724
    • Faisy C, Rabbat A, Kouchakji B, Laaban JP. Bioelectrical impedance analysis in estimating nutritional status and outcome of patients with chronic obstructive pulmonary disease and acute respiratory failure. Intensive Care Med. 2000;26(5):518–25.
    • (2000) Intensive Care Med , vol.26 , Issue.5 , pp. 518-525
    • Faisy, C.1    Rabbat, A.2    Kouchakji, B.3    Laaban, J.P.4
  • 23
    • 0034058703 scopus 로고    scopus 로고
    • A comparison of bioimpedance methods for detection of body cell mass change in HIV infection
    • COI: 1:STN:280:DC%2BD3c7nsFGmsQ%3D%3D, PID: 10710390
    • Earthman CP, Matthie JR, Reid PM, Harper IT, Ravussin E, Howell WH. A comparison of bioimpedance methods for detection of body cell mass change in HIV infection. J Appl Physiol. 2000;88(3):944–56.
    • (2000) J Appl Physiol , vol.88 , Issue.3 , pp. 944-956
    • Earthman, C.P.1    Matthie, J.R.2    Reid, P.M.3    Harper, I.T.4    Ravussin, E.5    Howell, W.H.6
  • 24
    • 0036178326 scopus 로고    scopus 로고
    • Accuracy of bioelectrical impedance spectroscopy in measuring changes in body composition during severe weight loss
    • Cox-Reijven PL, van Kreel B, Soeters PB. Accuracy of bioelectrical impedance spectroscopy in measuring changes in body composition during severe weight loss. J Parenter Enter Nutr. 2002;26(2):120–7.
    • (2002) J Parenter Enter Nutr , vol.26 , Issue.2 , pp. 120-127
    • Cox-Reijven, P.L.1    van Kreel, B.2    Soeters, P.B.3
  • 25
    • 56049112558 scopus 로고    scopus 로고
    • Multifrequency bioelectrical impedance analysis and bioimpedance spectroscopy for monitoring fluid and body cell mass changes after gastric bypass surgery
    • PID: 18676066
    • Mager JR, Sibley SD, Beckman TR, Kellogg TA, Earthman CP. Multifrequency bioelectrical impedance analysis and bioimpedance spectroscopy for monitoring fluid and body cell mass changes after gastric bypass surgery. Clin Nutr. 2008;27(6):832–41. doi:10.1016/j.clnu.2008.06.007.
    • (2008) Clin Nutr , vol.27 , Issue.6 , pp. 832-841
    • Mager, J.R.1    Sibley, S.D.2    Beckman, T.R.3    Kellogg, T.A.4    Earthman, C.P.5
  • 26
    • 21344431885 scopus 로고    scopus 로고
    • Can bioimpedance determine the volume of distribution of antibiotics in sepsis?
    • COI: 1:STN:280:DC%2BD2MzisVejsA%3D%3D, PID: 15973917
    • Balik M, Sedivy J, Waldauf P, Kolar M, Smejkalova V, Pachl J. Can bioimpedance determine the volume of distribution of antibiotics in sepsis? Anaesth Intensive Care. 2005;33(3):345–50.
    • (2005) Anaesth Intensive Care , vol.33 , Issue.3 , pp. 345-350
    • Balik, M.1    Sedivy, J.2    Waldauf, P.3    Kolar, M.4    Smejkalova, V.5    Pachl, J.6
  • 27
    • 0033967530 scopus 로고    scopus 로고
    • Relationship between central venous pressure and bioimpedance vector analysis in critically ill patients
    • COI: 1:STN:280:DC%2BD3c7ivV2ktg%3D%3D, PID: 10667512
    • Piccoli A, Pittoni G, Facco E, Favaro E, Pillon L. Relationship between central venous pressure and bioimpedance vector analysis in critically ill patients. Crit Care Med. 2000;28(1):132–7.
    • (2000) Crit Care Med , vol.28 , Issue.1 , pp. 132-137
    • Piccoli, A.1    Pittoni, G.2    Facco, E.3    Favaro, E.4    Pillon, L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.