Volumn 27, Issue 8, 1999, Pages 1472-1477

Use of single-frequency bioimpedance at 50 kHz to estimate total body water in patients with multiple organ failure and fluid overload

Author keywords

50 kHz bioimpedance; Body weight; Body weight changes; Critical care; Electrical conductivity; Fluid balance; Multiple organ failure; Severe edema; Total body water; Water loss

Indexed keywords

ADULT; AGED; ARTICLE; BODY POSITION; BODY WATER; CLINICAL ARTICLE; CONTROLLED STUDY; DISEASE ASSOCIATION; ELECTRIC CONDUCTIVITY; FEMALE; FLUID RETENTION; HUMAN; IMPEDANCE; INTENSIVE CARE; MALE; MULTIPLE ORGAN FAILURE; PRIORITY JOURNAL; TOTAL BODY WATER; WATER LOSS;

EID: 0032819629     PISSN: 00903493     EISSN: None     Source Type: Journal    
DOI: 10.1097/00003246-199908000-00012     Document Type: Article
Times cited : (29)

References (27)
  • 1
    • 0022553636 scopus 로고
    • Validation of tetrapolar bioelectrical impedance to assess human body composition
    • 1. Lukaski HC, Bolonchuk WW, Hall CB, et al: Validation of tetrapolar bioelectrical impedance to assess human body composition. J Appl Physiol 1986; 60:1327-1332
    • (1986) J Appl Physiol , vol.60 , pp. 1327-1332
    • Lukaski, H.C.1    Bolonchuk, W.W.2    Hall, C.B.3
  • 2
    • 0024820281 scopus 로고
    • Potential use of bioelectrical impedance of the 'whole body' and of body segments for the assessment of body composition: Comparison with densitometry and anthropometry
    • 2. Fuller NJ, Elia M: Potential use of bioelectrical impedance of the 'whole body' and of body segments for the assessment of body composition: Comparison with densitometry and anthropometry. Eur J Clin Nutr 1989; 43:779-791
    • (1989) Eur J Clin Nutr , vol.43 , pp. 779-791
    • Fuller, N.J.1    Elia, M.2
  • 3
    • 0024263738 scopus 로고
    • Estimation of body fluid volumes using tetrapolar bioelectrical impedance measurements
    • 3. Lukaski HC, Bolonchuk WW: Estimation of body fluid volumes using tetrapolar bioelectrical impedance measurements. Aviat Space Environ Med 1988; 59:1163-1169
    • (1988) Aviat Space Environ Med , vol.59 , pp. 1163-1169
    • Lukaski, H.C.1    Bolonchuk, W.W.2
  • 4
    • 0022473871 scopus 로고
    • Estimation of total body water by bioelectrical impedance analysis
    • 4. Kushner RF, Schoeller DA: Estimation of total body water by bioelectrical impedance analysis. Am J Clin Nutr 1986; 44:417-424
    • (1986) Am J Clin Nutr , vol.44 , pp. 417-424
    • Kushner, R.F.1    Schoeller, D.A.2
  • 5
    • 0025730820 scopus 로고
    • Assessment of changes in total body water in patients undergoing renal dialysis using bioelectrical impedance analysis
    • 5. Jebb SA, Elia M: Assessment of changes in total body water in patients undergoing renal dialysis using bioelectrical impedance analysis. Clin Nutr 1991; 10:81-84
    • (1991) Clin Nutr , vol.10 , pp. 81-84
    • Jebb, S.A.1    Elia, M.2
  • 7
    • 0028328587 scopus 로고
    • Total body water in pregnancy: Assessment by using bioelectrical impedance
    • 7. Lukaski HC, Siders WA, Nielsen EJ, et al: Total body water in pregnancy: Assessment by using bioelectrical impedance. Am J Clin Nutr 1994; 59:578-585
    • (1994) Am J Clin Nutr , vol.59 , pp. 578-585
    • Lukaski, H.C.1    Siders, W.A.2    Nielsen, E.J.3
  • 8
    • 0026563519 scopus 로고
    • Whole body and segmental bioelectrical-impedance analysis in patients with cirrhosis of the liver: Changes after treatment of ascites
    • 8. Zillikens MC, van den Berg JW, Wilson JH, et al: Whole body and segmental bioelectrical-impedance analysis in patients with cirrhosis of the liver: Changes after treatment of ascites. Am J Clin Nutr 1992; 55:621-625
    • (1992) Am J Clin Nutr , vol.55 , pp. 621-625
    • Zillikens, M.C.1    Van Den Berg, J.W.2    Wilson, J.H.3
  • 9
    • 0028132610 scopus 로고
    • Accuracy of bioelectrical impedance analysis in estimation of extracellular space in healthy subjects and in fluid retention states
    • 9. Sergi G, Bussolotto M, Perini P, et al: Accuracy of bioelectrical impedance analysis in estimation of extracellular space in healthy subjects and in fluid retention states. Ann Nutr Metab 1994; 38:158-165
    • (1994) Ann Nutr Metab , vol.38 , pp. 158-165
    • Sergi, G.1    Bussolotto, M.2    Perini, P.3
  • 10
    • 0029047991 scopus 로고
    • Bioelectric impedance detects fluid retention in patients undergoing cardiopulmonary bypass
    • 10. Gonzalez J, Morrissey T, Byrne T, et al: Bioelectric impedance detects fluid retention in patients undergoing cardiopulmonary bypass. J Thorac Cardiovasc Surg 1995; 110: 111-118
    • (1995) J Thorac Cardiovasc Surg , vol.110 , pp. 111-118
    • Gonzalez, J.1    Morrissey, T.2    Byrne, T.3
  • 11
    • 0026649467 scopus 로고
    • Noninvasive estimation of total body water in critically ill children after cardiac operations: Validation of a bioelectrical impedance method
    • 11. Novak I, Davies PS, Elliott MJ: Noninvasive estimation of total body water in critically ill children after cardiac operations: Validation of a bioelectrical impedance method. J Thorac Cardiovasc Surg 1992; 104:585-589
    • (1992) J Thorac Cardiovasc Surg , vol.104 , pp. 585-589
    • Novak, I.1    Davies, P.S.2    Elliott, M.J.3
  • 12
    • 0027096414 scopus 로고
    • Identifying body fluid distribution by measuring electrical impedance
    • 12. Scheltinga MR, Jacobs DA, Kimborough TD, et al: Identifying body fluid distribution by measuring electrical impedance. J Trauma 1992; 33:665-670
    • (1992) J Trauma , vol.33 , pp. 665-670
    • Scheltinga, M.R.1    Jacobs, D.A.2    Kimborough, T.D.3
  • 13
    • 0026756527 scopus 로고
    • Rapid bedside method to assess changes in postoperative fluid status with bioelectrical impedance analysis
    • 13. Meguid MM, Lukaski HC, Tripp MD, et al: Rapid bedside method to assess changes in postoperative fluid status with bioelectrical impedance analysis. Surgery 1992; 112: 502-508
    • (1992) Surgery , vol.112 , pp. 502-508
    • Meguid, M.M.1    Lukaski, H.C.2    Tripp, M.D.3
  • 14
    • 0020541461 scopus 로고
    • The fluid problem in the critically ill
    • 14. Lucas CE, Ledgerwood AM: The fluid problem in the critically ill. Surg Clin North Am 1983; 63:439-454
    • (1983) Surg Clin North Am , vol.63 , pp. 439-454
    • Lucas, C.E.1    Ledgerwood, A.M.2
  • 15
  • 16
    • 0023263008 scopus 로고
    • Aggressive nutritional support does not prevent protein loss despite fat gain in septic intensive care patients
    • 16. Streat SJ, Beddoe AH, Hill GJ: Aggressive nutritional support does not prevent protein loss despite fat gain in septic intensive care patients. J Trauma 1987; 27:272-376
    • (1987) J Trauma , vol.27 , pp. 272-376
    • Streat, S.J.1    Beddoe, A.H.2    Hill, G.J.3
  • 17
    • 0027265236 scopus 로고
    • Weight changes in critically ill patients evaluated by fluid balances and impedance measurements
    • 17. Roos AN, Westendorp RGJ, Frolich M, et al: Weight changes in critically ill patients evaluated by fluid balances and impedance measurements. Crit Care Med 1993; 21:871-877
    • (1993) Crit Care Med , vol.21 , pp. 871-877
    • Roos, A.N.1    Westendorp, R.G.J.2    Frolich, M.3
  • 18
    • 0029583486 scopus 로고
    • Energy and nitrogen balance and changes in mid upper-arm circumference with multiple organ failure
    • 18. Green CJ, Campbell IT, McClelland P, et al: Energy and nitrogen balance and changes in mid upper-arm circumference with multiple organ failure. Nutrition 1995; 11:739-746
    • (1995) Nutrition , vol.11 , pp. 739-746
    • Green, C.J.1    Campbell, I.T.2    McClelland, P.3
  • 19
    • 0026874127 scopus 로고
    • Definitions for sepsis and organ failure and guidelines for the use of innovative therapies in sepsis
    • 19. American College of Chest Physicians/ Society of Critical Care Medicine Consensus Conference: Definitions for sepsis and organ failure and guidelines for the use of innovative therapies in sepsis. Crit Care Med 1992; 20:864-874
    • (1992) Crit Care Med , vol.20 , pp. 864-874
  • 20
    • 0021850258 scopus 로고
    • Measurement of total body water in intensive care patients with fluid overload
    • 20. Streat SJ, Beddoe AH, Hill GL: Measurement of total body water in intensive care patients with fluid overload. Metabolism 1985; 34: 688-694
    • (1985) Metabolism , vol.34 , pp. 688-694
    • Streat, S.J.1    Beddoe, A.H.2    Hill, G.L.3
  • 21
    • 0001742838 scopus 로고
    • Rapid assay procedures for tritium labelled water in body fluids
    • 21. Vaughan BE, Boling EA: Rapid assay procedures for tritium labelled water in body fluids. J Lab Clin Med 1961; 57:159-164
    • (1961) J Lab Clin Med , vol.57 , pp. 159-164
    • Vaughan, B.E.1    Boling, E.A.2
  • 23
    • 0028924599 scopus 로고
    • Predictive value of tetrapolar body impedance measurements for hydration status in critically ill patients
    • 23. Roos AN, Westendorp RGJ, Brand R, et al: Predictive value of tetrapolar body impedance measurements for hydration status in critically ill patients. Intensive Care Med 1995; 21:125-131
    • (1995) Intensive Care Med , vol.21 , pp. 125-131
    • Roos, A.N.1    Westendorp, R.G.J.2    Brand, R.3
  • 24
    • 0028881307 scopus 로고
    • Comparison of bio-impedance spectroscopy and multifrequency bioimpedance analysis for the assessment of extracellular and total body water in surgical patients
    • 24. Hannan WJ, Cowen SJ, Plester CE, et al: Comparison of bio-impedance spectroscopy and multifrequency bioimpedance analysis for the assessment of extracellular and total body water in surgical patients. Clin Sci 1995; 89:651-658
    • (1995) Clin Sci , vol.89 , pp. 651-658
    • Hannan, W.J.1    Cowen, S.J.2    Plester, C.E.3
  • 25
    • 0009656678 scopus 로고
    • Use of the tetrapolar bioimpedance method to assess human body composition
    • Norgan NG (Ed). The Hague, CIP-gegevens Koninklijke Bibliotheek
    • 25. Lukaski HC: Use of the tetrapolar bioimpedance method to assess human body composition. In: Human Body Composition and Fat Distribution. Norgan NG (Ed). The Hague, CIP-gegevens Koninklijke Bibliotheek, 1985, pp 142-155
    • (1985) Human Body Composition and Fat Distribution , pp. 142-155
    • Lukaski, H.C.1
  • 26
    • 0026640935 scopus 로고
    • Assessment of changes in body water by bioimpedance in acutely ill surgical patients
    • 26. Chiolero RL, Gay LJ, Cotting J, et al: Assessment of changes in body water by bioimpedance in acutely ill surgical patients. Intensive Care Med 1992; 18:322-326
    • (1992) Intensive Care Med , vol.18 , pp. 322-326
    • Chiolero, R.L.1    Gay, L.J.2    Cotting, J.3
  • 27
    • 0029825841 scopus 로고    scopus 로고
    • Estimation of total body and extracellular water in post-coronary artery bypass graft surgical patients using single and multiple frequency bioimpedance
    • 27. Patel RV, Peterson EL, Silverman N, et al: Estimation of total body and extracellular water in post-coronary artery bypass graft surgical patients using single and multiple frequency bioimpedance. Crit Care Med 1996; 24:1824-1828
    • (1996) Crit Care Med , vol.24 , pp. 1824-1828
    • Patel, R.V.1    Peterson, E.L.2    Silverman, N.3