Volumn 20, Issue 4, 2000, Pages 283-291

Comparison of bioimpedance and radioisotope methods in the estimation of extracellular water volume before and after coronary artery bypass grafting operation

Author keywords

Bioimpedance analysis; Coronary artery bypass surgery; Extracellular water; Radioisotope dilution technique

Indexed keywords

EDETATE CHROMIUM CR 51; RADIOISOTOPE;

EID: 0033924376     PISSN: 01445979     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1365-2281.2000.00261.x     Document Type: Article
Times cited : (16)

References (36)
  • 2
    • 0015349668 scopus 로고
    • Sustained hypovolemia and extracellular fluid volume expansion following cardiopulmonary bypass
    • BEATTIE H. W., EVANS G., GARNETT E. S. & WEBBER C. E. (1972) Sustained hypovolemia and extracellular fluid volume expansion following cardiopulmonary bypass. Surgery, 71, 891-897.
    • (1972) Surgery , vol.71 , pp. 891-897
    • Beattie, H.W.1    Evans, G.2    Garnett, E.S.3    Webber, C.E.4
  • 3
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • BLAND J. M. & ALTMAN D. G. (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet, i, 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 4
    • 0031180466 scopus 로고    scopus 로고
    • Prediction of total body water in Indian men from anthropometry and bioelectrical impedance using deuterium dilution as reference
    • BORGONHA S., PETRACCHI C., LUZZI A. F., SHETTY P. S. & KURPAD A. V. (1997) Prediction of total body water in Indian men from anthropometry and bioelectrical impedance using deuterium dilution as reference. Ann Hum Biol, 24, 355-361.
    • (1997) Ann Hum Biol , vol.24 , pp. 355-361
    • Borgonha, S.1    Petracchi, C.2    Luzzi, A.F.3    Shetty, P.S.4    Kurpad, A.V.5
  • 5
    • 0031799280 scopus 로고    scopus 로고
    • Bedside determination of fluid accumulation after cardiac surgery using segmental bioelectrical impedance
    • BRACCO D., REVELLY J. P., BERGER M. M. & CHIOLERO R. L. (1998) Bedside determination of fluid accumulation after cardiac surgery using segmental bioelectrical impedance. Crit Care Med, 26, 1065-1070.
    • (1998) Crit Care Med , vol.26 , pp. 1065-1070
    • Bracco, D.1    Revelly, J.P.2    Berger, M.M.3    Chiolero, R.L.4
  • 6
  • 8
    • 0028807127 scopus 로고
    • Multifrequency bioelectrical impedance estimates the distribution of body water
    • CHA K., CHERTOW G. M., GONZALEZ J., LAZARUS J. M. & WILMORE D. W. (1995) Multifrequency bioelectrical impedance estimates the distribution of body water. J Appl Physiol, 79, 1316-1319.
    • (1995) J Appl Physiol , vol.79 , pp. 1316-1319
    • Cha, K.1    Chertow, G.M.2    Gonzalez, J.3    Lazarus, J.M.4    Wilmore, D.W.5
  • 9
    • 0015161889 scopus 로고
    • Relative extracellular fluid deficits in patients undergoing coronary artery bypass
    • COHN L. H. & ANGELL W. W. (1971) Relative extracellular fluid deficits in patients undergoing coronary artery bypass. Surg Forum, 22, 151-152.
    • (1971) Surg Forum , vol.22 , pp. 151-152
    • Cohn, L.H.1    Angell, W.W.2
  • 10
    • 0015113704 scopus 로고
    • Body fluid shifts after cardiopulmonary bypass. I. Effects of congestive heart failure and hemodilution
    • COHN L. H., ANGELL W. W. & SHUMWAY N. E. (1971) Body fluid shifts after cardiopulmonary bypass. I. Effects of congestive heart failure and hemodilution. J Thorac Cardiovasc Surg, 62, 423-430.
    • (1971) J Thorac Cardiovasc Surg , vol.62 , pp. 423-430
    • Cohn, L.H.1    Angell, W.W.2    Shumway, N.E.3
  • 11
    • 0022983361 scopus 로고
    • Electrical impedance tomography for thermal monitoring of hyperthermia treatment: An assessment using in vitro and in vivo measurements
    • CONWAY J. (1987) Electrical impedance tomography for thermal monitoring of hyperthermia treatment: an assessment using in vitro and in vivo measurements. Clin Phys Physiol Meas, 8 (Suppl. A), 141-146.
    • (1987) Clin Phys Physiol Meas , vol.8 , Issue.SUPPL. A , pp. 141-146
    • Conway, J.1
  • 12
    • 0029047991 scopus 로고
    • Bioelectric impedance detects fluid retention in patients undergoing cardiopulmonary bypass
    • GONZALEZ J., MORRISSEY T., BYRNE T., RIZZO R. & WILMORE D. (1995) Bioelectric impedance detects fluid retention in patients undergoing cardiopulmonary bypass. J Thorac Cardiovasc Surg, 110, 111-118.
    • (1995) J Thorac Cardiovasc Surg , vol.110 , pp. 111-118
    • Gonzalez, J.1    Morrissey, T.2    Byrne, T.3    Rizzo, R.4    Wilmore, D.5
  • 13
    • 0029764778 scopus 로고    scopus 로고
    • Effect of skin temperature on multifrequency bioelectrical impedance analysis
    • GUDIVAKA R., SCHOELLER D. & KUSHNER R. F. (1996) Effect of skin temperature on multifrequency bioelectrical impedance analysis. J Appl Physiol, 81, 838-845.
    • (1996) J Appl Physiol , vol.81 , pp. 838-845
    • Gudivaka, R.1    Schoeller, D.2    Kushner, R.F.3
  • 14
    • 0028198209 scopus 로고
    • Evaluation of multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients
    • HANNAN W. J., COWEN S. J., FEARON K. C., PLESTER C. E., FALCONER J. S. & RICHARDSON R. A. (1994) Evaluation of multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients. Clin Sci, 86, 479-485.
    • (1994) Clin Sci , vol.86 , pp. 479-485
    • Hannan, W.J.1    Cowen, S.J.2    Fearon, K.C.3    Plester, C.E.4    Falconer, J.S.5    Richardson, R.A.6
  • 15
    • 0028881307 scopus 로고
    • Comparison of bio-impedance spectroscopy and multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients
    • HANNAN W. J., COWEN S. J., PLESTER C. E., FEARON K. C. & DEBEAU A. (1995) Comparison of bio-impedance spectroscopy and multi-frequency bio-impedance analysis for the assessment of extracellular and total body water in surgical patients. Clin Sci (Colch), 89, 651-658.
    • (1995) Clin Sci (Colch) , vol.89 , pp. 651-658
    • Hannan, W.J.1    Cowen, S.J.2    Plester, C.E.3    Fearon, K.C.4    Debeau, A.5
  • 16
    • 0034054098 scopus 로고    scopus 로고
    • Segmental composition of whole-body impedance cardiogram estimated by computer simulations and clinical experiments
    • KAUPPINEN P., KOOBI T., HYTTINEN J. & MALMIVUO J. (2000) Segmental composition of whole-body impedance cardiogram estimated by computer simulations and clinical experiments. Clin Physiol, 20, 106-113.
    • (2000) Clin Physiol , vol.20 , pp. 106-113
    • Kauppinen, P.1    Koobi, T.2    Hyttinen, J.3    Malmivuo, J.4
  • 17
    • 0022384422 scopus 로고
    • Assessment of glomerular filtration rate (GFR) and extracellular fluid volume (ECF) in the perioperative phase
    • KLETTER K., LACKNER F. & ZIMPFER M. (1985) Assessment of glomerular filtration rate (GFR) and extracellular fluid volume (ECF) in the perioperative phase. Anaesthesia, 34, 600-606.
    • (1985) Anaesthesia , vol.34 , pp. 600-606
    • Kletter, K.1    Lackner, F.2    Zimpfer, M.3
  • 19
    • 0030716837 scopus 로고    scopus 로고
    • Non-invasive measurement of cardiac output: Whole-body impedance cardiography in simultaneous comparison with thermodilution and direct oxygen Fick methods
    • KOOBI T., KAUKINEN S., AHOLA T. & TURJANMAA V. M. (1997a) Non-invasive measurement of cardiac output: whole-body impedance cardiography in simultaneous comparison with thermodilution and direct oxygen Fick methods. Intensive Care Med, 23, 1132-1137.
    • (1997) Intensive Care Med , vol.23 , pp. 1132-1137
    • Koobi, T.1    Kaukinen, S.2    Ahola, T.3    Turjanmaa, V.M.4
  • 20
    • 0030988157 scopus 로고    scopus 로고
    • Whole-body impedance cardiography in the measurement of cardiac output
    • KOOBI T., KAUNKINEN S., TURJANMAA V. M. & UUSITALO A. J. (1997b) Whole-body impedance cardiography in the measurement of cardiac output. Crit Care Med, 25, 779-785.
    • (1997) Crit Care Med , vol.25 , pp. 779-785
    • Koobi, T.1    Kaunkinen, S.2    Turjanmaa, V.M.3    Uusitalo, A.J.4
  • 21
    • 0022473871 scopus 로고
    • Estimation of total body water by bioelectrical impedance analysis
    • KUSHNER R. F. & SCHOELLER D. A. (1986) Estimation of total body water by bioelectrical impedance analysis. Am J Clin Nutr, 44, 417-424.
    • (1986) Am J Clin Nutr , vol.44 , pp. 417-424
    • Kushner, R.F.1    Schoeller, D.A.2
  • 22
    • 0015429593 scopus 로고
    • A comparison of the distribution volumes of inulin and (51 Cr) EDTA in man and nephrectomized dogs
    • LADEGAARD-PEDERSEN H. J. & ENGELL H. C. (1972) A comparison of the distribution volumes of inulin and (51 Cr) EDTA in man and nephrectomized dogs. Scand J Clin Lab Invest, 30, 267-270.
    • (1972) Scand J Clin Lab Invest , vol.30 , pp. 267-270
    • Ladegaard-Pedersen, H.J.1    Engell, H.C.2
  • 23
    • 0016761198 scopus 로고
    • A comparison between the changes in the distribution volumes of inulin and [51Cr]EDTA after major surgery
    • LADEGAARD-PEDERSEN H. J. & ENGELL H. C. (1975) A comparison between the changes in the distribution volumes of inulin and [51Cr]EDTA after major surgery. Scand J Clin Lab Invest, 35, 109-113.
    • (1975) Scand J Clin Lab Invest , vol.35 , pp. 109-113
    • Ladegaard-Pedersen, H.J.1    Engell, H.C.2
  • 24
    • 0023488498 scopus 로고
    • Methods for the assessment of human body composition: Traditional and new
    • LUKASKI H. C. (1987) Methods for the assessment of human body composition: traditional and new. Am J Clin Nutr, 46, 537-556.
    • (1987) Am J Clin Nutr , vol.46 , pp. 537-556
    • Lukaski, H.C.1
  • 25
    • 0022553636 scopus 로고
    • Validation of tetrapolar bioelectrical impedance method to assess human body composition
    • LUKASKI H. C., BOLONCHUK W. W., HALL C. B. & SIDERS W. A. (1986) Validation of tetrapolar bioelectrical impedance method to assess human body composition. J Appl Physiol, 60, 1327-1332.
    • (1986) J Appl Physiol , vol.60 , pp. 1327-1332
    • Lukaski, H.C.1    Bolonchuk, W.W.2    Hall, C.B.3    Siders, W.A.4
  • 26
    • 0001666449 scopus 로고
    • The interrelationship between the galvanic skin response, basal resistance, and temperature
    • MAULSBY R. L. & EDELBERG R. (1960) The interrelationship between the galvanic skin response, basal resistance, and temperature. J Comp Physiol Psychol, 53, 475-479.
    • (1960) J Comp Physiol Psychol , vol.53 , pp. 475-479
    • Maulsby, R.L.1    Edelberg, R.2
  • 29
    • 0029825841 scopus 로고    scopus 로고
    • Estimation of total body and extracellular water in post-coronary artery bypass graft surgical patients using single and multiple frequency bioimpedance
    • PATEL R. Y., PETERSON E. L., SILVERMAN N. & ZAROWITZ B. J. (1996) Estimation of total body and extracellular water in post-coronary artery bypass graft surgical patients using single and multiple frequency bioimpedance. Crit Care Med, 24, 1824-1828.
    • (1996) Crit Care Med , vol.24 , pp. 1824-1828
    • Patel, R.Y.1    Peterson, E.L.2    Silverman, N.3    Zarowitz, B.J.4
  • 30
    • 0025830394 scopus 로고
    • Alterations in body fluid content can be detected by bioelectrical impedance analysis
    • SCHELTINGA M. R., JACOBS D. O., KIMBROUGH T. D. & WILMORE D. W. (1991) Alterations in body fluid content can be detected by bioelectrical impedance analysis. J Surg Res, 50, 461-468.
    • (1991) J Surg Res , vol.50 , pp. 461-468
    • Scheltinga, M.R.1    Jacobs, D.O.2    Kimbrough, T.D.3    Wilmore, D.W.4
  • 31
    • 0028023789 scopus 로고
    • Comparison of extra-cellular fluid volume measurement in children by 99Tcm-DPTA clearance and multi-frequency impedance techniques
    • SMYE S. W., NORWOOD H. M., BUUR T., BRADBURY M. & BROCKLEBANK J. T. (1994) Comparison of extra-cellular fluid volume measurement in children by 99Tcm-DPTA clearance and multi-frequency impedance techniques. Physiol Meas, 15, 251-260.
    • (1994) Physiol Meas , vol.15 , pp. 251-260
    • Smye, S.W.1    Norwood, H.M.2    Buur, T.3    Bradbury, M.4    Brocklebank, J.T.5
  • 32
    • 0029019771 scopus 로고
    • Determination of body composition in children and adolescents: Validation of bioelectrical impedance with isotope dilution technique
    • SUPRASONGSIN C., KALHAN S. & ARSLANIAN S. (1995) Determination of body composition in children and adolescents: validation of bioelectrical impedance with isotope dilution technique. J Pediatr Endocr Metab, 8, 103-109.
    • (1995) J Pediatr Endocr Metab , vol.8 , pp. 103-109
    • Suprasongsin, C.1    Kalhan, S.2    Arslanian, S.3
  • 33
    • 0015885524 scopus 로고
    • Measurement of the stroke blood volume by an integral rheogram of the human body
    • TISHCHENKO M. I. (1973) Measurement of the stroke blood volume by an integral rheogram of the human body [in Russian]. Fiziologicheskii Zhurnal SSSR, 59, 1216-1224.
    • (1973) Fiziologicheskii Zhurnal SSSR , vol.59 , pp. 1216-1224
    • Tishchenko, M.I.1
  • 34
    • 0005171028 scopus 로고
    • Renal function and fluid balance with cardiopulmonary bypass
    • (eds Gravlee G. P., Davis R. F. & Utley J. R.), Williams & Wilkins, Baltimore
    • UTLEY J. R. (1993) Renal function and fluid balance with cardiopulmonary bypass. In: Cardiopulmonary Bypass, Principles and Practice (eds Gravlee G. P., Davis R. F. & Utley J. R.), pp. 488-508. Williams & Wilkins, Baltimore.
    • (1993) Cardiopulmonary Bypass, Principles and Practice , pp. 488-508
    • Utley, J.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.