메뉴 건너뛰기




Volumn 63, Issue 10, 2015, Pages 3016-3025

Design and in Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor

Author keywords

Biomedical sensors; dielectric measurements; emerging application for RF microwaves; material characterization; microwave sensors

Indexed keywords

ASCORBIC ACID; BLOOD; GLUCOSE; NATURAL FREQUENCIES; ORGANIC ACIDS; TESTING;

EID: 84959468041     PISSN: 00189480     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMTT.2015.2472019     Document Type: Article
Times cited : (236)

References (33)
  • 1
    • 84946913153 scopus 로고    scopus 로고
    • Diabetes UK, London, U.K.
    • "2014 annual report," Diabetes UK, London, U.K., 2015.
    • (2015) 2014 Annual Report
  • 2
  • 3
    • 0031036953 scopus 로고    scopus 로고
    • Noninvasive blood glucose monitoring
    • Mar.
    • D. C. Klonoff, "Noninvasive blood glucose monitoring," Diabetes Care, vol. 20, no. 3, pp. 433-437, Mar. 1997.
    • (1997) Diabetes Care , vol.20 , Issue.3 , pp. 433-437
    • Klonoff, D.C.1
  • 4
    • 0032995738 scopus 로고    scopus 로고
    • Spectroscopic and clinical aspects of noninvasive glucose measurements
    • Feb.
    • O. S. Khalil, "Spectroscopic and clinical aspects of noninvasive glucose measurements," Clin. Chem., vol. 45, no. 2, pp. 165-177, Feb. 1999.
    • (1999) Clin. Chem. , vol.45 , Issue.2 , pp. 165-177
    • Khalil, O.S.1
  • 5
    • 84901716123 scopus 로고    scopus 로고
    • Continuous glucose monitoring systems: A review
    • Oct.
    • S. K. Vashist, "Continuous glucose monitoring systems: A review," Diagnostics, vol. 3, no. 4, pp. 385-412, Oct. 2013.
    • (2013) Diagnostics , vol.3 , Issue.4 , pp. 385-412
    • Vashist, S.K.1
  • 6
    • 0034061329 scopus 로고    scopus 로고
    • Transdermal monitoring of glucose and other analytes using ultrasound
    • Mar.
    • J. Kost, S. Mitragotri, R. A. Gabbay, M. Pishko, and R. Langer, "Transdermal monitoring of glucose and other analytes using ultrasound," Nature Med., vol. 6, no. 3, pp. 347-350, Mar. 2000.
    • (2000) Nature Med. , vol.6 , Issue.3 , pp. 347-350
    • Kost, J.1    Mitragotri, S.2    Gabbay, R.A.3    Pishko, M.4    Langer, R.5
  • 7
    • 84959560796 scopus 로고    scopus 로고
    • An integrated wireless fluorimeter for a long term implantable, continuous glucose monitoring system
    • presented at Vienna, Austria, Feb. 5-8
    • A. DeHennis et al., "An integrated wireless fluorimeter for a long term implantable, continuous glucose monitoring system," presented at the 7th Int. Adv. Technol. Treatments for Diabetes Conf., Vienna, Austria, Feb. 5-8, 2014.
    • (2014) The 7th Int. Adv. Technol. Treatments for Diabetes Conf.
    • DeHennis, A.1
  • 8
    • 84959495564 scopus 로고    scopus 로고
    • Comparative performance between the former Glucowatch® and an improved non-invasive continuous glucose monitoring watch (CGM Watch™)
    • presented at Vienna, Austria, Feb. 5-8
    • F. Chowdhury and Y. Han, "Comparative performance between the former Glucowatch® and an improved non-invasive continuous glucose monitoring watch (CGM Watch™)," presented at the 7th Int. Adv. Technol. Treatments for Diabetes Conf., Vienna, Austria, Feb. 5-8, 2014.
    • (2014) The 7th Int. Adv. Technol. Treatments for Diabetes Conf.
    • Chowdhury, F.1    Han, Y.2
  • 9
    • 84959565204 scopus 로고    scopus 로고
    • Calibration schemes of a truly non-invasive glucose monitor for variety of diabetics
    • presented at
    • A. Gal et al., "Calibration schemes of a truly non-invasive glucose monitor for variety of diabetics," presented at the 7th Int. Ad. Technol. Treatments for Diabetes Conf., Vienna, Austria, Feb. 5-8, 2014.
    • (2014) The 7th Int. Ad. Technol. Treatments for Diabetes Conf.
    • Gal, A.1
  • 10
    • 84863844193 scopus 로고    scopus 로고
    • A 3-uW CMOS glucose sensor for wireless contact-lens tear glucose monitoring
    • Jan.
    • Y. Liao, H. Hao, A. Lingley, B. Parviz, and B. Otis, "A 3-uW CMOS glucose sensor for wireless contact-lens tear glucose monitoring," IEEE J. Solid-State Circuits, vol. 47, no. 1, pp. 335-344, Jan. 2012.
    • (2012) IEEE J. Solid-State Circuits , vol.47 , Issue.1 , pp. 335-344
    • Liao, Y.1    Hao, H.2    Lingley, A.3    Parviz, B.4    Otis, B.5
  • 11
    • 62449149289 scopus 로고    scopus 로고
    • Continuous noninvasive glucose monitoring technology based on occlusion spectroscopy
    • Jul.
    • O. Amir et al., "Continuous noninvasive glucose monitoring technology based on occlusion spectroscopy," J. Diabetes Sci. Technol., vol. 1, no. 4, pp. 463-469, Jul. 2007.
    • (2007) J. Diabetes Sci. Technol. , vol.1 , Issue.4 , pp. 463-469
    • Amir, O.1
  • 12
    • 84959518209 scopus 로고    scopus 로고
    • CGM sensor design principles for reliable and accurate glucose monitoring in the subcutaneous tissue
    • presented at Vienna, Austria, Feb. 5-8
    • M. Schoemaker, G. Schmelzeisen-Redeker, and J. Jager, "CGM sensor design principles for reliable and accurate glucose monitoring in the subcutaneous tissue," presented at the 7th Int. Adv. Technol. Treatments for Diabetes Conf., Vienna, Austria, Feb. 5-8, 2014.
    • (2014) The 7th Int. Adv. Technol. Treatments for Diabetes Conf.
    • Schoemaker, M.1    Schmelzeisen-Redeker, G.2    Jager, J.3
  • 13
    • 73049097259 scopus 로고    scopus 로고
    • Integrated broadband microwave and microfluidic sensor dedicated to bioengineering
    • Dec.
    • K. Grenier et al., "Integrated broadband microwave and microfluidic sensor dedicated to bioengineering," IEEE Trans. Microw. Theory Techn., vol. 57, no. 12, pp. 3246-3253, Dec. 2009.
    • (2009) IEEE Trans. Microw. Theory Techn. , vol.57 , Issue.12 , pp. 3246-3253
    • Grenier, K.1
  • 14
    • 78649760553 scopus 로고    scopus 로고
    • A microwave frequency sensor for non-invasive blood-glucose measurement
    • Atlanta, GA, USA
    • B. R. Jean, E. C. Green, and M. J. McClung, "A microwave frequency sensor for non-invasive blood-glucose measurement," in IEEE Sensors Appl. Symp., Atlanta, GA, USA, 2008, pp. 4-7.
    • (2008) IEEE Sensors Appl. Symp. , pp. 4-7
    • Jean, B.R.1    Green, E.C.2    McClung, M.J.3
  • 16
    • 84877789833 scopus 로고    scopus 로고
    • Microwave-based noninvasive concentration measurements for biomedical applications
    • May
    • M. Hofmann, G. Fischer, R. Weigel, and D. Kissinger, "Microwave-based noninvasive concentration measurements for biomedical applications," IEEE Trans. Microw. Theory Techn., vol. 61, no. 5, pp. 2195-2204, May 2013.
    • (2013) IEEE Trans. Microw. Theory Techn. , vol.61 , Issue.5 , pp. 2195-2204
    • Hofmann, M.1    Fischer, G.2    Weigel, R.3    Kissinger, D.4
  • 17
    • 84901975700 scopus 로고    scopus 로고
    • Broadband tissue mimicking phantoms and a patch resonator for evaluating noninvasive monitoring of blood glucose levels
    • Jun.
    • T. Yilmaz, R. Foster, and Y. Hao, "Broadband tissue mimicking phantoms and a patch resonator for evaluating noninvasive monitoring of blood glucose levels," IEEE Trans. Antennas Propag., vol. 62, no. 6, pp. 3064-3075, Jun. 2014.
    • (2014) IEEE Trans. Antennas Propag. , vol.62 , Issue.6 , pp. 3064-3075
    • Yilmaz, T.1    Foster, R.2    Hao, Y.3
  • 18
    • 84911981574 scopus 로고    scopus 로고
    • Millimeter-wave non-invasive monitoring of glucose in anesthetized rats
    • Tucson, AZ, USA, Sep. 14-19
    • P. H. Siegel, Y. Lee, and V. Pikov, "Millimeter-wave non-invasive monitoring of glucose in anesthetized rats," in 39th Int. Infrared, Millimeter, Terahertz Waves Conf., Tucson, AZ, USA, Sep. 14-19, 2014, pp. 1-2.
    • (2014) 39th Int. Infrared, Millimeter, Terahertz Waves Conf. , pp. 1-2
    • Siegel, P.H.1    Lee, Y.2    Pikov, V.3
  • 19
    • 0242654854 scopus 로고    scopus 로고
    • The correlation of the complex dielectric constant and blood glucose at low frequency
    • Dec.
    • J. H. Pack, C. S. Kim, B. C. Choi, and K. Y. Ham, "The correlation of the complex dielectric constant and blood glucose at low frequency," Biosens. Bioelectron., vol. 19, no. 4, pp. 321-324, Dec. 2003.
    • (2003) Biosens. Bioelectron. , vol.19 , Issue.4 , pp. 321-324
    • Pack, J.H.1    Kim, C.S.2    Choi, B.C.3    Ham, K.Y.4
  • 20
    • 0242357278 scopus 로고    scopus 로고
    • First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system
    • Nov.
    • A. Caduff, E. Hirt, Y. Feldman, Z. Ali, and L. Heinemann, "First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system," Biosens. Bioelectron., vol. 19, no. 3, pp. 209-217, Nov. 2003.
    • (2003) Biosens. Bioelectron. , vol.19 , Issue.3 , pp. 209-217
    • Caduff, A.1    Hirt, E.2    Feldman, Y.3    Ali, Z.4    Heinemann, L.5
  • 21
    • 0020928860 scopus 로고
    • Loop-gap resonator: A lumped mode microwave resonant structure
    • Dec.
    • M. Mehdizadeh, T. K. Ishii, J. S. Hyde, and W. Froncisz, "Loop-gap resonator: A lumped mode microwave resonant structure," IEEE Trans. Microw. Theory Techn., vol. MTT-31, no. 12, pp. 1059-1064, Dec. 1983.
    • (1983) IEEE Trans. Microw. Theory Techn. , vol.MTT-31 , Issue.12 , pp. 1059-1064
    • Mehdizadeh, M.1    Ishii, T.K.2    Hyde, J.S.3    Froncisz, W.4
  • 22
    • 0021202876 scopus 로고
    • The microstrip open-ring resonator
    • Jan.
    • I. Wolff and V. K. Tripathi, "The microstrip open-ring resonator," IEEE Trans. Microw. Theory Techn., vol. MTT-32, no. 1, pp. 102-107, Jan. 1984.
    • (1984) IEEE Trans. Microw. Theory Techn. , vol.MTT-32 , Issue.1 , pp. 102-107
    • Wolff, I.1    Tripathi, V.K.2
  • 23
    • 84898596955 scopus 로고    scopus 로고
    • Improved split-ring resonator for microfluidic sensing
    • Mar.
    • D. J. Rowe et al., "Improved split-ring resonator for microfluidic sensing," IEEE Trans. Microw. Theory Techn., vol. 62, no. 3, pp. 689-699, Mar. 2014.
    • (2014) IEEE Trans. Microw. Theory Techn. , vol.62 , Issue.3 , pp. 689-699
    • Rowe, D.J.1
  • 24
    • 84898600671 scopus 로고    scopus 로고
    • Novel microwave microfluidic sensor using a microstrip split-ring resonator
    • Mar.
    • A. A. Abduljabar, D. J. Rowe, A. Porch, and D. A. Barrow, "Novel microwave microfluidic sensor using a microstrip split-ring resonator," IEEE Trans. Microw. Theory Techn., vol. 62, no. 3, pp. 679-688, Mar. 2014.
    • (2014) IEEE Trans. Microw. Theory Techn. , vol.62 , Issue.3 , pp. 679-688
    • Abduljabar, A.A.1    Rowe, D.J.2    Porch, A.3    Barrow, D.A.4
  • 25
    • 84879812632 scopus 로고    scopus 로고
    • Microwave properties of nanodiamond particles
    • Jun.
    • D. Slocombe, A. Porch, E. Bustarret, and O. A. Williams, "Microwave properties of nanodiamond particles," Appl. Phys. Lett., vol. 102, no. 24, Jun. 2013, Art. ID 2441021.
    • (2013) Appl. Phys. Lett. , vol.102 , Issue.24
    • Slocombe, D.1    Porch, A.2    Bustarret, E.3    Williams, O.A.4
  • 28
    • 0029909341 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: II. Measurements in frequency range 10 Hz to 20 GHz
    • Nov.
    • S. Gabriel, R. W. Lau, and C. Gabriel, "The dielectric properties of biological tissues: II. Measurements in frequency range 10 Hz to 20 GHz," Phys. Med. Biol., vol. 41, no. 11, pp. 2251-2269, Nov. 1996.
    • (1996) Phys. Med. Biol. , vol.41 , Issue.11 , pp. 2251-2269
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 31
    • 70350209515 scopus 로고    scopus 로고
    • Factors affecting blood glucose monitoring: Sources of errors in measurement
    • Jul.
    • B. H. Ginsberg, "Factors affecting blood glucose monitoring: Sources of errors in measurement," J. Diabetes Sci. Technol., vol. 3, no. 4, pp. 903-913, Jul. 2009.
    • (2009) J. Diabetes Sci. Technol. , vol.3 , Issue.4 , pp. 903-913
    • Ginsberg, B.H.1
  • 32
    • 0016610679 scopus 로고
    • Percutaneous absorption. on the relevance of in vitro data
    • T. J. Franz, "Percutaneous absorption. On the relevance of in vitro data," J. Investigat. Dermatol., vol. 64, no. 3, pp. 190-195, 1975.
    • (1975) J. Investigat. Dermatol. , vol.64 , Issue.3 , pp. 190-195
    • Franz, T.J.1
  • 33
    • 0035834259 scopus 로고    scopus 로고
    • Modulated insulin delivery from glucose-sensitive hydrogel dosage forms
    • Nov.
    • J. J. Kim and K. Park, "Modulated insulin delivery from glucose-sensitive hydrogel dosage forms," J. Control. Release, vol. 77, no. 1-2, pp. 39-47, Nov. 2001.
    • (2001) J. Control. Release , vol.77 , Issue.1-2 , pp. 39-47
    • Kim, J.J.1    Park, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.