메뉴 건너뛰기




Volumn 47, Issue 1, 2012, Pages 335-344

A 3-μW CMOS glucose sensor for wireless contact-lens tear glucose monitoring

Author keywords

Contact lens; glucose sensor; heterogeneous integration; low power; noninvasive; potentiostat; wireless health monitoring

Indexed keywords

HETEROGENEOUS INTEGRATION; LOW POWER; NONINVASIVE; POTENTIOSTATS; WIRELESS HEALTH MONITORING;

EID: 84863844193     PISSN: 00189200     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSSC.2011.2170633     Document Type: Article
Times cited : (330)

References (19)
  • 1
    • 73749083481 scopus 로고    scopus 로고
    • Global estimates of the prevalence of diabetes for 2010 and 2030
    • Jan.
    • J. E. Shaw, R. A. Sicree, and Z. Zimmet, "Global estimates of the prevalence of diabetes for 2010 and 2030," Diabetes Res. Clin. Prac., vol. 87, pp. 4-14, Jan. 2010.
    • (2010) Diabetes Res. Clin. Prac. , vol.87 , pp. 4-14
    • Shaw, J.E.1    Sicree, R.A.2    Zimmet, Z.3
  • 3
    • 84878016587 scopus 로고
    • Biochemistry of the Eye. New York: Plenum
    • E. Berman, Biochemistry of the Eye. New York: Plenum, 1991.
    • (1991)
    • Berman, E.1
  • 4
    • 84942606868 scopus 로고    scopus 로고
    • Biochemistry of the Eye. London, U.K.: Butterworth-Heinemann
    • D. Whikehart, Biochemistry of the Eye. London, U.K.: Butterworth- Heinemann, 2003.
    • (2003)
    • Whikehart, D.1
  • 5
    • 74049118781 scopus 로고    scopus 로고
    • A technique to measure eyelid pressure using piezoresistive sensors
    • Oct.
    • A. Shaw, B. Davis, M. Collins, and L. Carney, "A technique to measure eyelid pressure using piezoresistive sensors," IEEE Trans. Biomed. Eng., vol. 56, no. 10, pp. 2512-2517, Oct. 2009.
    • (2009) IEEE Trans. Biomed. Eng. , vol.56 , Issue.10 , pp. 2512-2517
    • Shaw, A.1    Davis, B.2    Collins, M.3    Carney, L.4
  • 7
    • 84944726312 scopus 로고    scopus 로고
    • A soft contact lens with a mems strain gage embedded for intraocular pressure monitoring
    • Solid-State Sensors, Actuators Microsyst., Jun.
    • M. Leonardi, P. Leuenberger, D. Bertrand, A. Bertsch, and P. Renaud, "A soft contact lens with a mems strain gage embedded for intraocular pressure monitoring," in Proc. 12th Int. Conf. Transducers, Solid-State Sensors, Actuators Microsyst., Jun. 2003, vol. 2, pp. 1043-1046.
    • (2003) Proc. 12th Int. Conf. Transducers , vol.2 , pp. 1043-1046
    • Leonardi, M.1    Leuenberger, P.2    Bertrand, D.3    Bertsch, A.4    Renaud, P.5
  • 10
    • 79955722523 scopus 로고    scopus 로고
    • A 3 w wirelessly powered cmos glucose sensor for an active contact lens
    • Feb.
    • Y.-T. Liao, H. Yao, B. Parviz, and B. Otis, "A 3 w wirelessly powered cmos glucose sensor for an active contact lens," in IEEE ISSCC Dig. Tech. Papers, Feb. 2011, pp. 38-40.
    • (2011) IEEE ISSCC Dig. Tech. Papers , pp. 38-40
    • Liao, Y.-T.1    Yao, H.2    Parviz, B.3    Otis, B.4
  • 11
    • 58149166895 scopus 로고    scopus 로고
    • Development of urine glucose meter based on micro-planer amperometric biosensor and its clinical application for self-monitoring of urine glucose
    • M. Miyashita, N. Ito, S. Ikeda, T. Murayama, K. Oguma, and J. Kimura, "Development of urine glucose meter based on micro-planer amperometric biosensor and its clinical application for self-monitoring of urine glucose," Biosensors Bioelectron., vol. 24, no. 5, pp. 1336-1340, 2009.
    • (2009) Biosensors Bioelectron. , vol.24 , Issue.5 , pp. 1336-1340
    • Miyashita, M.1    Ito, N.2    Ikeda, S.3    Murayama, T.4    Oguma, K.5    Kimura, J.6
  • 12
    • 79951726135 scopus 로고    scopus 로고
    • A contact lens with embedded sensor for monitoring tear glucose level
    • H. Yao, A. Shum, M. Cowana, I. Lähdesmäkia, and B. Parviz, "A contact lens with embedded sensor for monitoring tear glucose level," Biosensors Bioelectron., vol. 26, no. 7, pp. 3290-3296, 2011.
    • (2011) Biosensors Bioelectron. , vol.26 , Issue.7 , pp. 3290-3296
    • Yao, H.1    Shum, A.2    Cowana, M.3    Lähdesmäkia, I.4    Parviz, B.5
  • 13
    • 79953796973 scopus 로고    scopus 로고
    • A dual microscale glucose sensor on a contact lens, tested in conditions mimicking the eye
    • Jan.
    • H.Yao, A. Afanasiev, I. Lahdesmaki, and B. Parviz, "A dual microscale glucose sensor on a contact lens, tested in conditions mimicking the eye," in Proc. IEEE 24th Int. Conf. MEMS, Jan. 2011, pp. 25-28.
    • (2011) Proc. IEEE 24th Int. Conf. MEMS , pp. 25-28
    • Yao, H.1    Afanasiev, A.2    Lahdesmaki, I.3    Parviz, B.4
  • 14
    • 38349087158 scopus 로고    scopus 로고
    • Surface modification of a perfluorinated ionomer using a glow discharge deposition method to control protein adsorption
    • T. Valdes, W. Ciridon, B. Ratner, and J. Bryers, "Surface modification of a perfluorinated ionomer using a glow discharge deposition method to control protein adsorption," Biomaterials, vol. 29, no. 10, pp. 1356-1366, 2008.
    • (2008) Biomaterials , vol.29 , Issue.10 , pp. 1356-1366
    • Valdes, T.1    Ciridon, W.2    Ratner, B.3    Bryers, J.4
  • 15
    • 77955091787 scopus 로고    scopus 로고
    • A wireless-implantable microsystem for continuous blood glucose monitoring
    • Jun.
    • M. Ahmadi and G. Jullien, "A wireless-implantable microsystem for continuous blood glucose monitoring," IEEE Trans. Biomed. Circuits Syst., vol. 3, no. 3, pp. 169-180, Jun. 2009.
    • (2009) IEEE Trans. Biomed. Circuits Syst. , vol.3 , Issue.3 , pp. 169-180
    • Ahmadi, M.1    Jullien, G.2
  • 17
    • 67651160770 scopus 로고    scopus 로고
    • Current-mirror-based potentiostats for three-electrode amperometric electrochemical sensors
    • Jul.
    • M. Ahmadi and G. Jullien, "Current-mirror-based potentiostats for three-electrode amperometric electrochemical sensors," IEEE Trans. Circuits Syst. I, Reg. Papers, vol. 56, no. 7, pp. 1339-1348, Jul. 2009.
    • (2009) IEEE Trans. Circuits Syst. I, Reg. Papers , vol.56 , Issue.7 , pp. 1339-1348
    • Ahmadi, M.1    Jullien, G.2
  • 19
    • 85048786741 scopus 로고    scopus 로고
    • Low-power low-voltage current read-out circuit for inductively-powered implant system
    • M. R. Haider, S. K. Islam, S. Mostafa, M. Zhang, and T. Oh, "Low-power low-voltage current read-out circuit for inductively-powered implant system," IEEE Trans. Antennas Propag., vol. PP, no. 99, pp. 31-40, 2010.
    • (2010) IEEE Trans. Antennas Propag. , vol.PP , Issue.99 , pp. 31-40
    • Haider, M.R.1    Islam, S.K.2    Mostafa, S.3    Zhang, M.4    Oh, T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.