메뉴 건너뛰기




Volumn 129, Issue 3, 2016, Pages 274-282.e2

Prognostic Value of Undetectable hs Troponin T in Suspected Acute Coronary Syndrome

Author keywords

Acute coronary syndrome (ACS); Acute myocardial infarction (AMI); Copeptin; High sensitivity troponin T (hsTnT); Limit of detection (LoD); Rule out

Indexed keywords

COPEPTIN; HIGH SENSITIVITY TROPONIN T; TROPONIN T; UNCLASSIFIED DRUG; BIOLOGICAL MARKER; GLYCOPEPTIDE;

EID: 84958051174     PISSN: 00029343     EISSN: 15557162     Source Type: Journal    
DOI: 10.1016/j.amjmed.2015.10.016     Document Type: Article
Times cited : (28)

References (20)
  • 1
    • 84874941217 scopus 로고    scopus 로고
    • Chief complaints in medical emergencies: Do they relate to underlying disease and outcome? the Charite Emergency Medicine Study (CHARITEM)
    • M. Mockel, J. Searle, R. Muller, and et al. Chief complaints in medical emergencies: do they relate to underlying disease and outcome? The Charite Emergency Medicine Study (CHARITEM) Eur J Emerg Med 20 2013 103 108
    • (2013) Eur J Emerg Med , vol.20 , pp. 103-108
    • Mockel, M.1    Searle, J.2    Muller, R.3
  • 2
    • 84856158305 scopus 로고    scopus 로고
    • ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: The Task Force for the management of acute coronary syndromes (ACS) in patients presenting without persistent ST-segment elevation of the European Society of Cardiology (ESC)
    • C.W. Hamm, J.P. Bassand, S. Agewall, et al. ESC Committee for Practice Guidelines ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: the Task Force for the management of acute coronary syndromes (ACS) in patients presenting without persistent ST-segment elevation of the European Society of Cardiology (ESC) Eur Heart J 32 23 2011 2999 3054
    • (2011) Eur Heart J , vol.32 , Issue.23 , pp. 2999-3054
    • Hamm, C.W.1    Bassand, J.P.2    Agewall, S.3
  • 3
    • 84886304639 scopus 로고    scopus 로고
    • Rapid rule out of acute myocardial infarction using undetectable levels of high-sensitivity cardiac troponin
    • M. Rubini Giménez, R. Hoeller, T. Reichlin, and et al. Rapid rule out of acute myocardial infarction using undetectable levels of high-sensitivity cardiac troponin Int J Cardiol 168 4 2013 3896 3901
    • (2013) Int J Cardiol , vol.168 , Issue.4 , pp. 3896-3901
    • Rubini Giménez, M.1    Hoeller, R.2    Reichlin, T.3
  • 4
    • 84921908439 scopus 로고    scopus 로고
    • Diagnostic accuracy of single baseline measurement of Elecsys Troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: Systematic review and meta-analysis
    • Z. Zhelev, C. Hyde, E. Youngman, and et al. Diagnostic accuracy of single baseline measurement of Elecsys Troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: systematic review and meta-analysis BMJ 350 2015 h15
    • (2015) BMJ , vol.350 , pp. h15
    • Zhelev, Z.1    Hyde, C.2    Youngman, E.3
  • 5
    • 77954351802 scopus 로고    scopus 로고
    • Biological and analytical variability of a novel high-sensitivity cardiac troponin T assay
    • V.C. Vasile, A.K. Saenger, J.M. Kroning, and et al. Biological and analytical variability of a novel high-sensitivity cardiac troponin T assay Clin Chem 56 7 2010 1086 1090
    • (2010) Clin Chem , vol.56 , Issue.7 , pp. 1086-1090
    • Vasile, V.C.1    Saenger, A.K.2    Kroning, J.M.3
  • 6
    • 80052974660 scopus 로고    scopus 로고
    • Rapid exclusion of acute myocardial infarction in patients with undetectable troponin using a high-sensitivity assay
    • R. Body, S. Carley, G. McDowell, and et al. Rapid exclusion of acute myocardial infarction in patients with undetectable troponin using a high-sensitivity assay J Am Coll Cardiol 58 2011 1332 1339
    • (2011) J Am Coll Cardiol , vol.58 , pp. 1332-1339
    • Body, R.1    Carley, S.2    McDowell, G.3
  • 7
    • 84902138306 scopus 로고    scopus 로고
    • Undetectable high-sensitivity cardiac troponin T level in the emergency department and risk of myocardial infarction
    • N. Bandstein, R. Ljung, M. Johansson, and et al. Undetectable high-sensitivity cardiac troponin T level in the emergency department and risk of myocardial infarction J Am Coll Cardiol 63 23 2014 2569 2578
    • (2014) J Am Coll Cardiol , vol.63 , Issue.23 , pp. 2569-2578
    • Bandstein, N.1    Ljung, R.2    Johansson, M.3
  • 8
    • 84925480988 scopus 로고    scopus 로고
    • Early discharge using single cardiac troponin and copeptin testing in patients with suspected acute coronary syndrome (ACS): A randomized, controlled clinical process study
    • M. Möckel, J. Searle, C. Hamm, and et al. Early discharge using single cardiac troponin and copeptin testing in patients with suspected acute coronary syndrome (ACS): a randomized, controlled clinical process study Eur Heart J 36 6 2015 369 376
    • (2015) Eur Heart J , vol.36 , Issue.6 , pp. 369-376
    • Möckel, M.1    Searle, J.2    Hamm, C.3
  • 9
    • 75749150570 scopus 로고    scopus 로고
    • Analytical validation of a high-sensitivity cardiac troponin T assay
    • E. Giannitsis, K. Kurz, K. Hallermayer, and et al. Analytical validation of a high-sensitivity cardiac troponin T assay Clin Chem 56 2 2010 254 261
    • (2010) Clin Chem , vol.56 , Issue.2 , pp. 254-261
    • Giannitsis, E.1    Kurz, K.2    Hallermayer, K.3
  • 10
    • 77955435768 scopus 로고    scopus 로고
    • The new high-sensitivity cardiac troponin T assay improves risk assessment in acute coronary syndromes
    • B. Lindahl, P. Venge, and S. James The new high-sensitivity cardiac troponin T assay improves risk assessment in acute coronary syndromes Am Heart J 160 2 2010 224 229
    • (2010) Am Heart J , vol.160 , Issue.2 , pp. 224-229
    • Lindahl, B.1    Venge, P.2    James, S.3
  • 11
    • 84869108301 scopus 로고    scopus 로고
    • Diagnostic and prognostic performance of a novel high-sensitivity cardiac troponin T assay compared to a contemporary sensitive cardiac troponin i assay in patients with acute coronary syndrome
    • M. Mueller, S. Celik, M. Biener, and et al. Diagnostic and prognostic performance of a novel high-sensitivity cardiac troponin T assay compared to a contemporary sensitive cardiac troponin I assay in patients with acute coronary syndrome Clin Res Cardiol 101 10 2012 837 845
    • (2012) Clin Res Cardiol , vol.101 , Issue.10 , pp. 837-845
    • Mueller, M.1    Celik, S.2    Biener, M.3
  • 12
    • 73549124781 scopus 로고    scopus 로고
    • Prevention of Events with Angiotensin Converting Enzyme Inhibition (PEACE) Trial Investigators. A sensitive cardiac troponin T assay in stable coronary artery disease
    • T. Omland, J.A. de Lemos, M.S. Sabatine, and et al. Prevention of Events with Angiotensin Converting Enzyme Inhibition (PEACE) Trial Investigators. A sensitive cardiac troponin T assay in stable coronary artery disease N Engl J Med 361 26 2009 2538 2547
    • (2009) N Engl J Med , vol.361 , Issue.26 , pp. 2538-2547
    • Omland, T.1    De Lemos, J.A.2    Sabatine, M.S.3
  • 13
    • 79961050437 scopus 로고    scopus 로고
    • High-sensitivity cardiac troponin i measurement for risk stratification in a stable high-risk population
    • P.A. Kavsak, L. Xu, S. Yusuf, and et al. High-sensitivity cardiac troponin I measurement for risk stratification in a stable high-risk population Clin Chem 57 8 2011 1146 1153
    • (2011) Clin Chem , vol.57 , Issue.8 , pp. 1146-1153
    • Kavsak, P.A.1    Xu, L.2    Yusuf, S.3
  • 14
    • 78649843808 scopus 로고    scopus 로고
    • Association of troponin T detected with a highly sensitive assay and cardiac structure and mortality risk in the general population
    • J.A. de Lemos, M.H. Drazner, T. Omland, and et al. Association of troponin T detected with a highly sensitive assay and cardiac structure and mortality risk in the general population JAMA 304 22 2010 2503 2512
    • (2010) JAMA , vol.304 , Issue.22 , pp. 2503-2512
    • De Lemos, J.A.1    Drazner, M.H.2    Omland, T.3
  • 15
    • 84893822597 scopus 로고    scopus 로고
    • High population prevalence of cardiac troponin i measured by a high-sensitivity assay and cardiovascular risk estimation: The MORGAM Biomarker Project Scottish Cohort
    • T. Zeller, H. Tunstall-Pedoe, O. Saarela, et al. MORGAM Investigators High population prevalence of cardiac troponin I measured by a high-sensitivity assay and cardiovascular risk estimation: the MORGAM Biomarker Project Scottish Cohort Eur Heart J 35 5 2014 271 281
    • (2014) Eur Heart J , vol.35 , Issue.5 , pp. 271-281
    • Zeller, T.1    Tunstall-Pedoe, H.2    Saarela, O.3
  • 16
    • 67650035169 scopus 로고    scopus 로고
    • A new season for cardiac troponin assays: It's time to keep a scorecard
    • F.S. Apple A new season for cardiac troponin assays: it's time to keep a scorecard Clin Chem 55 7 2009 1303 1306
    • (2009) Clin Chem , vol.55 , Issue.7 , pp. 1303-1306
    • Apple, F.S.1
  • 17
    • 84868105856 scopus 로고    scopus 로고
    • Clinical implications of a recent adjustment to the high-sensitivity cardiac troponin T assay: User beware
    • F.S. Apple, and A.S. Jaffe Clinical implications of a recent adjustment to the high-sensitivity cardiac troponin T assay: user beware Clin Chem 58 11 2012 1599 1600
    • (2012) Clin Chem , vol.58 , Issue.11 , pp. 1599-1600
    • Apple, F.S.1    Jaffe, A.S.2
  • 18
    • 84874591834 scopus 로고    scopus 로고
    • Release kinetics of copeptin in patients undergoing transcoronary ablation of septal hypertrophy
    • C. Liebetrau, H. Nef, Szardien, and et al. Release kinetics of copeptin in patients undergoing transcoronary ablation of septal hypertrophy Clin Chem 59 3 2013 566 569
    • (2013) Clin Chem , vol.59 , Issue.3 , pp. 566-569
    • Liebetrau, C.1    Nef, H.2    Szardien3
  • 19
    • 84898637651 scopus 로고    scopus 로고
    • A systematic review and collaborative meta-analysis to determine the incremental value of copeptin for rapid rule-out of acute myocardial infarction
    • M.J. Lipinski, R.O. Escárcega, F. D'Ascenzo, and et al. A systematic review and collaborative meta-analysis to determine the incremental value of copeptin for rapid rule-out of acute myocardial infarction Am J Cardiol 113 9 2014 1581 1591
    • (2014) Am J Cardiol , vol.113 , Issue.9 , pp. 1581-1591
    • Lipinski, M.J.1    Escárcega, R.O.2    D'Ascenzo, F.3
  • 20
    • 84906258958 scopus 로고    scopus 로고
    • Diagnostic accuracy of combined cardiac troponin and copeptin assessment for early rule-out of myocardial infarction: A systematic review and meta-analysis
    • T. Raskovalova, R. Twerenbold, P.O. Collinson, and et al. Diagnostic accuracy of combined cardiac troponin and copeptin assessment for early rule-out of myocardial infarction: a systematic review and meta-analysis Eur Heart J Acute Cardiovasc Care 3 1 2014 18 27
    • (2014) Eur Heart J Acute Cardiovasc Care , vol.3 , Issue.1 , pp. 18-27
    • Raskovalova, T.1    Twerenbold, R.2    Collinson, P.O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.