메뉴 건너뛰기




Volumn 17, Issue 1, 2016, Pages 36-44

A Cross-Sectional Survey of Near-Infrared Spectroscopy Use in Pediatric Cardiac ICUs in the United Kingdom, Ireland, Italy, and Germany

Author keywords

brain monitoring; cerebral oximeter; cerebral saturation; pediatric cardiac surgery; regional oxygen saturation; tissue oxygenation index

Indexed keywords

ARTERY BYPASS; ARTICLE; BRAIN PERFUSION; CROSS-SECTIONAL STUDY; EXTRACORPOREAL OXYGENATION; GERMANY; HEART OUTPUT; HIGH RISK PATIENT; HUMAN; HYPOPLASTIC LEFT HEART SYNDROME; INTENSIVE CARE; INTENSIVE CARE UNIT; IRELAND; ITALY; MULTICENTER STUDY; NEAR INFRARED SPECTROSCOPY; NEUROMONITORING; OXYGEN SATURATION; PALLIATIVE THERAPY; PATIENT MONITORING; POSTOPERATIVE CARE; PREOPERATIVE CARE; PRIORITY JOURNAL; UNITED KINGDOM; ALGORITHM; BLOOD; BRAIN; CLINICAL PROTOCOL; CLINICAL TRIAL; EUROPE; HEART SURGERY; ORGANIZATION AND MANAGEMENT; OXIMETRY; PEDIATRIC INTENSIVE CARE UNIT; PERIOPERATIVE PERIOD; PROCEDURES; RISK ASSESSMENT; UTILIZATION; VASCULARIZATION;

EID: 84953863049     PISSN: 15297535     EISSN: 19473893     Source Type: Journal    
DOI: 10.1097/PCC.0000000000000564     Document Type: Article
Times cited : (23)

References (47)
  • 1
    • 10744227442 scopus 로고    scopus 로고
    • Changes in cerebral and somatic oxygenation during stage 1 palliation of hypoplastic left heart syndrome using continuous regional cerebral perfusion
    • Hoffman GM, Stuth EA, Jaquiss RD, et al: Changes in cerebral and somatic oxygenation during stage 1 palliation of hypoplastic left heart syndrome using continuous regional cerebral perfusion. J Thorac Cardiovasc Surg 2004; 127:223-233
    • (2004) J Thorac Cardiovasc Surg , vol.127 , pp. 223-233
    • Hoffman, G.M.1    Stuth, E.A.2    Jaquiss, R.D.3
  • 2
    • 77956885774 scopus 로고    scopus 로고
    • Perioperative monitoring in high-risk infants after stage 1 palliation of univentricular congenital heart disease
    • Ghanayem NS, Hoffman GM, Mussatto KA, et al: Perioperative monitoring in high-risk infants after stage 1 palliation of univentricular congenital heart disease. J Thorac Cardiovasc Surg 2010; 140:857-863
    • (2010) J Thorac Cardiovasc Surg , vol.140 , pp. 857-863
    • Ghanayem, N.S.1    Hoffman, G.M.2    Mussatto, K.A.3
  • 3
    • 20444449773 scopus 로고    scopus 로고
    • A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients
    • Tortoriello TA, Stayer SA, Mott AR, et al: A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients. Paediatr Anaesth 2005; 15:495-503
    • (2005) Paediatr Anaesth , vol.15 , pp. 495-503
    • Tortoriello, T.A.1    Stayer, S.A.2    Mott, A.R.3
  • 4
    • 33746349282 scopus 로고    scopus 로고
    • Pro: Near-infrared spectroscopy should be used for all cardiopulmonary bypass
    • Hoffman GM: Pro: Near-infrared spectroscopy should be used for all cardiopulmonary bypass. J Cardiothorac Vasc Anesth 2006; 20:606-612
    • (2006) J Cardiothorac Vasc Anesth , vol.20 , pp. 606-612
    • Hoffman, G.M.1
  • 6
    • 79954560468 scopus 로고    scopus 로고
    • Cerebral oximetry for pediatric anesthesia: Why do intelligent clinicians disagree?
    • Kasman N, Brady K: Cerebral oximetry for pediatric anesthesia: Why do intelligent clinicians disagree? Paediatr Anaesth 2011; 21:473-478
    • (2011) Paediatr Anaesth , vol.21 , pp. 473-478
    • Kasman, N.1    Brady, K.2
  • 7
    • 84969298920 scopus 로고    scopus 로고
    • Near infrared spectroscopy in paediatric cardiac surgery - A review of local experience and national survey
    • Langford R, Jenkins, I. Near infrared spectroscopy in paediatric cardiac surgery - A review of local experience and national survey. Paediatr Anaesth 2009;19:717-718
    • (2009) Paediatr Anaesth , vol.19 , pp. 717-718
    • Langford, R.1    Jenkins, I.2
  • 8
    • 0033034079 scopus 로고    scopus 로고
    • Near infrared spectroscopy can detect changes in splanchnic oxygen delivery in neonates during apnoeic episodes
    • Petros AJ, Heys R, Tasker RC, et al: Near infrared spectroscopy can detect changes in splanchnic oxygen delivery in neonates during apnoeic episodes. Eur J Pediatr 1999; 158:173-174
    • (1999) Eur J Pediatr , vol.158 , pp. 173-174
    • Petros, A.J.1    Heys, R.2    Tasker, R.C.3
  • 9
    • 77953837168 scopus 로고    scopus 로고
    • Cerebral and somatic near-infrared spectroscopy in normal newborns
    • Bernal NP, Hoffman GM, Ghanayem NS, et al: Cerebral and somatic near-infrared spectroscopy in normal newborns. J Pediatr Surg 2010; 45:1306-1310
    • (2010) J Pediatr Surg , vol.45 , pp. 1306-1310
    • Bernal, N.P.1    Hoffman, G.M.2    Ghanayem, N.S.3
  • 10
    • 14944364787 scopus 로고    scopus 로고
    • Brain tissue oxygenation index measured by near infrared spatially resolved spectroscopy agreed with jugular bulb oxygen saturation in normal pediatric brain: A pilot study
    • Shimizu N, Gilder F, Bissonnette B, et al: Brain tissue oxygenation index measured by near infrared spatially resolved spectroscopy agreed with jugular bulb oxygen saturation in normal pediatric brain: A pilot study. Childs Nerv Syst 2005; 21:181-184
    • (2005) Childs Nerv Syst , vol.21 , pp. 181-184
    • Shimizu, N.1    Gilder, F.2    Bissonnette, B.3
  • 11
    • 21244490736 scopus 로고    scopus 로고
    • Comparison between cerebral tissue oxygenation index measured by near-infrared spectroscopy and venous jugular bulb saturation in children
    • Nagdyman N, Fleck T, Schubert S, et al: Comparison between cerebral tissue oxygenation index measured by near-infrared spectroscopy and venous jugular bulb saturation in children. Intensive Care Med 2005; 31:846-850
    • (2005) Intensive Care Med , vol.31 , pp. 846-850
    • Nagdyman, N.1    Fleck, T.2    Schubert, S.3
  • 12
    • 0033775089 scopus 로고    scopus 로고
    • Arterial and venous contributions to near-infrared cerebral oximetry
    • Watzman HM, Kurth CD, Montenegro LM, et al: Arterial and venous contributions to near-infrared cerebral oximetry. Anesthesiology 2000; 93:947-953
    • (2000) Anesthesiology , vol.93 , pp. 947-953
    • Watzman, H.M.1    Kurth, C.D.2    Montenegro, L.M.3
  • 13
    • 84872401056 scopus 로고    scopus 로고
    • Cerebral perfusion during cardiopulmonary bypass in children: Correlations between near-infrared spectroscopy, temperature, lactate, pump flow, and blood pressure
    • Haydin S, Onan B, Onan IS, et al: Cerebral perfusion during cardiopulmonary bypass in children: Correlations between near-infrared spectroscopy, temperature, lactate, pump flow, and blood pressure. Artif Organs 2013; 37:87-91
    • (2013) Artif Organs , vol.37 , pp. 87-91
    • Haydin, S.1    Onan, B.2    Onan, I.S.3
  • 14
    • 70349314621 scopus 로고    scopus 로고
    • Multisite near-infrared spectroscopy predicts elevated blood lactate level in children after cardiac surgery
    • Chakravarti SB, Mittnacht AJ, Katz JC, et al: Multisite near-infrared spectroscopy predicts elevated blood lactate level in children after cardiac surgery. J Cardiothorac Vasc Anesth 2009; 23:663-667
    • (2009) J Cardiothorac Vasc Anesth , vol.23 , pp. 663-667
    • Chakravarti, S.B.1    Mittnacht, A.J.2    Katz, J.C.3
  • 15
    • 33750364999 scopus 로고    scopus 로고
    • Assessment of the relationship between cerebral and splanchnic oxygen saturations measured by near-infrared spectroscopy and direct measurements of systemic haemodynamic variables and oxygen transport after the Norwood procedure
    • Li J, Van Arsdell GS, Zhang G, et al: Assessment of the relationship between cerebral and splanchnic oxygen saturations measured by near-infrared spectroscopy and direct measurements of systemic haemodynamic variables and oxygen transport after the Norwood procedure. Heart 2006; 92:1678-1685
    • (2006) Heart , vol.92 , pp. 1678-1685
    • Li, J.1    Van Arsdell, G.S.2    Zhang, G.3
  • 16
    • 84893645527 scopus 로고    scopus 로고
    • Cerebral near-infrared spectroscopy correlates to vital parameters during cardiopulmonary bypass surgery in children
    • Menke J, Möller G: Cerebral near-infrared spectroscopy correlates to vital parameters during cardiopulmonary bypass surgery in children. Pediatr Cardiol 2014; 35:155-163
    • (2014) Pediatr Cardiol , vol.35 , pp. 155-163
    • Menke, J.1    Möller, G.2
  • 17
    • 38849179456 scopus 로고    scopus 로고
    • A proposed algorithm for the intraoperative use of cerebral near-infrared spectroscopy
    • Denault A, Deschamps A, Murkin JM: A proposed algorithm for the intraoperative use of cerebral near-infrared spectroscopy. Semin Cardiothorac Vasc Anesth 2007; 11:274-281
    • (2007) Semin Cardiothorac Vasc Anesth , vol.11 , pp. 274-281
    • Denault, A.1    Deschamps, A.2    Murkin, J.M.3
  • 18
    • 0030720067 scopus 로고    scopus 로고
    • Benefit of neurophysiologic monitoring for pediatric cardiac surgery
    • 717
    • Austin EH 3rd, Edmonds HL Jr, Auden SM, et al: Benefit of neurophysiologic monitoring for pediatric cardiac surgery. J Thorac Cardiovasc Surg 1997; 114:707-715, 717
    • (1997) J Thorac Cardiovasc Surg , vol.114 , pp. 707-715
    • Austin, E.H.1    Edmonds, H.L.2    Auden, S.M.3
  • 19
    • 33748372262 scopus 로고    scopus 로고
    • Bilateral monitoring of cerebral oxygen saturation results in recognition of aortic cannula malposition during pediatric congenital heart surgery
    • Gottlieb EA, Fraser CD Jr, Andropoulos DB, et al: Bilateral monitoring of cerebral oxygen saturation results in recognition of aortic cannula malposition during pediatric congenital heart surgery. Paediatr Anaesth 2006; 16:787-789
    • (2006) Paediatr Anaesth , vol.16 , pp. 787-789
    • Gottlieb, E.A.1    Fraser, C.D.2    Andropoulos, D.B.3
  • 20
    • 0031666377 scopus 로고    scopus 로고
    • Near infrared spectroscopy detects cerebral ischemia during hypotension in piglets
    • Tsuji M, duPlessis A, Taylor G, et al: Near infrared spectroscopy detects cerebral ischemia during hypotension in piglets. Pediatr Res 1998; 44:591-595
    • (1998) Pediatr Res , vol.44 , pp. 591-595
    • Tsuji, M.1    DuPlessis, A.2    Taylor, G.3
  • 21
    • 84906937384 scopus 로고    scopus 로고
    • Comparison of four near-infrared spectroscopy devices shows that they are only suitable for monitoring cerebral oxygenation trends in preterm infants
    • Schneider A, Minnich B, Hofstätter E, et al: Comparison of four near-infrared spectroscopy devices shows that they are only suitable for monitoring cerebral oxygenation trends in preterm infants. Acta Paediatr 2014; 103:934-938
    • (2014) Acta Paediatr , vol.103 , pp. 934-938
    • Schneider, A.1    Minnich, B.2    Hofstätter, E.3
  • 22
    • 84867821728 scopus 로고    scopus 로고
    • Evaluation of pediatric near-infrared cerebral oximeter for cardiac disease
    • Kreeger RN, Ramamoorthy C, Nicolson SC, et al: Evaluation of pediatric near-infrared cerebral oximeter for cardiac disease. Ann Thorac Surg 2012; 94:1527-1533
    • (2012) Ann Thorac Surg , vol.94 , pp. 1527-1533
    • Kreeger, R.N.1    Ramamoorthy, C.2    Nicolson, S.C.3
  • 23
    • 84896394636 scopus 로고    scopus 로고
    • Survey of the clinical assessment and utility of near-infrared cerebral oximetry in cardiac surgery
    • Zacharias DG, Lilly K, Shaw CL, et al: Survey of the clinical assessment and utility of near-infrared cerebral oximetry in cardiac surgery. J Cardiothorac Vasc Anesth 2014; 28:308-316
    • (2014) J Cardiothorac Vasc Anesth , vol.28 , pp. 308-316
    • Zacharias, D.G.1    Lilly, K.2    Shaw, C.L.3
  • 24
    • 6444235523 scopus 로고    scopus 로고
    • Neurological monitoring for congenital heart surgery
    • table of contents
    • Andropoulos DB, Stayer SA, Diaz LK, et al: Neurological monitoring for congenital heart surgery. Anesth Analg 2004; 99:1365-1375; table of contents
    • (2004) Anesth Analg , vol.99 , pp. 1365-1375
    • Andropoulos, D.B.1    Stayer, S.A.2    Diaz, L.K.3
  • 25
    • 16644383579 scopus 로고    scopus 로고
    • Detection of unintentional partial superior vena cava occlusion during a bidirectional cavopulmonary anastomosis
    • Ing RJ, Lawson DS, Jaggers J, et al: Detection of unintentional partial superior vena cava occlusion during a bidirectional cavopulmonary anastomosis. J Cardiothorac Vasc Anesth 2004; 18:472-474
    • (2004) J Cardiothorac Vasc Anesth , vol.18 , pp. 472-474
    • Ing, R.J.1    Lawson, D.S.2    Jaggers, J.3
  • 26
    • 3042519043 scopus 로고    scopus 로고
    • Cerebral ischemia caused by obstructed superior vena cava cannula is detected by near-infrared spectroscopy
    • Sakamoto T, Duebener LF, Laussen PC, et al: Cerebral ischemia caused by obstructed superior vena cava cannula is detected by near-infrared spectroscopy. J Cardiothorac Vasc Anesth 2004; 18:293-303
    • (2004) J Cardiothorac Vasc Anesth , vol.18 , pp. 293-303
    • Sakamoto, T.1    Duebener, L.F.2    Laussen, P.C.3
  • 27
    • 84880835875 scopus 로고    scopus 로고
    • Role of intraoperative regional oxygen saturation using near infrared spectroscopy in the prediction of low output syndrome after pediatric heart surgery
    • Zulueta JL, Vida VL, Perisinotto E, et al: Role of intraoperative regional oxygen saturation using near infrared spectroscopy in the prediction of low output syndrome after pediatric heart surgery. J Card Surg 2013; 28:446-452
    • (2013) J Card Surg , vol.28 , pp. 446-452
    • Zulueta, J.L.1    Vida, V.L.2    Perisinotto, E.3
  • 28
    • 0035909006 scopus 로고    scopus 로고
    • Impact of inspired gas mixtures on preoperative infants with hypoplastic left heart syndrome during controlled ventilation
    • Tabbutt S, Ramamoorthy C, Montenegro LM, et al: Impact of inspired gas mixtures on preoperative infants with hypoplastic left heart syndrome during controlled ventilation. Circulation 2001; 104:I159-I164
    • (2001) Circulation , vol.104 , pp. I159-I164
    • Tabbutt, S.1    Ramamoorthy, C.2    Montenegro, L.M.3
  • 29
    • 58249137786 scopus 로고    scopus 로고
    • Near-infrared spectroscopy in neonates before palliation of hypoplastic left heart syndrome
    • discussion 577
    • Johnson BA, Hoffman GM, Tweddell JS, et al: Near-infrared spectroscopy in neonates before palliation of hypoplastic left heart syndrome. Ann Thorac Surg 2009; 87:571-577; discussion 577
    • (2009) Ann Thorac Surg , vol.87 , pp. 571-577
    • Johnson, B.A.1    Hoffman, G.M.2    Tweddell, J.S.3
  • 30
    • 84885918741 scopus 로고    scopus 로고
    • Perioperative cerebral oxygen saturation in neonates with hypoplastic left heart syndrome and childhood neurodevelopmental outcome
    • Hoffman GM, Brosig CL, Mussatto KA, et al: Perioperative cerebral oxygen saturation in neonates with hypoplastic left heart syndrome and childhood neurodevelopmental outcome. J Thorac Cardiovasc Surg 2013; 146:1153-1164
    • (2013) J Thorac Cardiovasc Surg , vol.146 , pp. 1153-1164
    • Hoffman, G.M.1    Brosig, C.L.2    Mussatto, K.A.3
  • 31
    • 64649098160 scopus 로고    scopus 로고
    • Postoperative cerebral oxygenation in hypoplastic left heart syndrome after the Norwood procedure
    • Phelps HM, Mahle WT, Kim D, et al: Postoperative cerebral oxygenation in hypoplastic left heart syndrome after the Norwood procedure. Ann Thorac Surg 2009; 87:1490-1494
    • (2009) Ann Thorac Surg , vol.87 , pp. 1490-1494
    • Phelps, H.M.1    Mahle, W.T.2    Kim, D.3
  • 32
    • 84891817361 scopus 로고    scopus 로고
    • Cerebral near-infrared spectroscopy in perioperative management of left ventricular assist device and extracorporeal membrane oxygenation patients
    • Maldonado Y, Singh S, Taylor MA: Cerebral near-infrared spectroscopy in perioperative management of left ventricular assist device and extracorporeal membrane oxygenation patients. Curr Opin Anaesthesiol 2014; 27:81-88
    • (2014) Curr Opin Anaesthesiol , vol.27 , pp. 81-88
    • Maldonado, Y.1    Singh, S.2    Taylor, M.A.3
  • 33
    • 33645551309 scopus 로고    scopus 로고
    • Cerebral oxygenation in neonatal and pediatric patients during veno-arterial extracorporeal life support
    • Ejike JC, Schenkman KA, Seidel K, et al: Cerebral oxygenation in neonatal and pediatric patients during veno-arterial extracorporeal life support. Pediatr Crit Care Med 2006; 7:154-158
    • (2006) Pediatr Crit Care Med , vol.7 , pp. 154-158
    • Ejike, J.C.1    Schenkman, K.A.2    Seidel, K.3
  • 34
    • 84868660416 scopus 로고    scopus 로고
    • Multichannel near infrared spectroscopy indicates regional variations in cerebral autoregulation in infants supported on extracorporeal membrane oxygenation
    • Papademetriou MD, Tachtsidis I, Elliot MJ, et al: Multichannel near infrared spectroscopy indicates regional variations in cerebral autoregulation in infants supported on extracorporeal membrane oxygenation. J Biomed Opt 2012; 17:067008
    • (2012) J Biomed Opt , vol.17 , pp. 067008
    • Papademetriou, M.D.1    Tachtsidis, I.2    Elliot, M.J.3
  • 35
    • 33749320421 scopus 로고    scopus 로고
    • Validation of a noninvasive neonatal optical cerebral oximeter in veno-venous ECMO patients with a cephalad catheter
    • Rais-Bahrami K, Rivera O, Short BL: Validation of a noninvasive neonatal optical cerebral oximeter in veno-venous ECMO patients with a cephalad catheter. J Perinatol 2006; 26:628-635
    • (2006) J Perinatol , vol.26 , pp. 628-635
    • Rais-Bahrami, K.1    Rivera, O.2    Short, B.L.3
  • 36
    • 0028800303 scopus 로고
    • Near-infrared spectroscopy for the in vivo study of cerebral hemodynamics and oxygenation
    • du Plessis AJ: Near-infrared spectroscopy for the in vivo study of cerebral hemodynamics and oxygenation. Curr Opin Pediatr 1995; 7:632-639
    • (1995) Curr Opin Pediatr , vol.7 , pp. 632-639
    • Du Plessis, A.J.1
  • 37
    • 22044456172 scopus 로고    scopus 로고
    • The significance of baseline cerebral oxygen saturation in children undergoing congenital heart surgery
    • Fenton KN, Freeman K, Glogowski K, et al: The significance of baseline cerebral oxygen saturation in children undergoing congenital heart surgery. Am J Surg 2005; 190:260-263
    • (2005) Am J Surg , vol.190 , pp. 260-263
    • Fenton, K.N.1    Freeman, K.2    Glogowski, K.3
  • 38
    • 27944491921 scopus 로고    scopus 로고
    • Brain magnetic resonance imaging abnormalities after the Norwood procedure using regional cerebral perfusion
    • Dent CL, Spaeth JP, Jones BV, et al: Brain magnetic resonance imaging abnormalities after the Norwood procedure using regional cerebral perfusion. J Thorac Cardiovasc Surg 2005; 130:1523-1530
    • (2005) J Thorac Cardiovasc Surg , vol.130 , pp. 1523-1530
    • Dent, C.L.1    Spaeth, J.P.2    Jones, B.V.3
  • 39
    • 84990347709 scopus 로고    scopus 로고
    • Prognostic value of perioperative near-infrared spectroscopy during neonatal and infant congenital heart surgery for adverse in-hospital clinical events
    • Dodge-Khatami J, Gottschalk U, Eulenburg C, et al: Prognostic value of perioperative near-infrared spectroscopy during neonatal and infant congenital heart surgery for adverse in-hospital clinical events. World J Pediatr Congenit Heart Surg 2012; 3:221-228
    • (2012) World J Pediatr Congenit Heart Surg , vol.3 , pp. 221-228
    • Dodge-Khatami, J.1    Gottschalk, U.2    Eulenburg, C.3
  • 40
    • 34147093080 scopus 로고    scopus 로고
    • Regional and central venous oxygen saturation monitoring following pediatric cardiac surgery: Concordance and association with clinical variables
    • McQuillen PS, Nishimoto MS, Bottrell CL, et al: Regional and central venous oxygen saturation monitoring following pediatric cardiac surgery: Concordance and association with clinical variables. Pediatr Crit Care Med 2007; 8:154-160
    • (2007) Pediatr Crit Care Med , vol.8 , pp. 154-160
    • McQuillen, P.S.1    Nishimoto, M.S.2    Bottrell, C.L.3
  • 41
    • 64649090919 scopus 로고    scopus 로고
    • Near infrared spectroscopy changes with pericardial tamponade
    • Maher KO, Phelps HM, Kirshbom PM: Near infrared spectroscopy changes with pericardial tamponade. Pediatr Crit Care Med 2009; 10:e13-e15
    • (2009) Pediatr Crit Care Med , vol.10 , pp. e13-e15
    • Maher, K.O.1    Phelps, H.M.2    Kirshbom, P.M.3
  • 42
    • 84923050613 scopus 로고    scopus 로고
    • Near-infrared spectroscopy after high-risk congenital heart surgery in the paediatric intensive care unit
    • Tume LN, Arnold P. Near-infrared spectroscopy after high-risk congenital heart surgery in the paediatric intensive care unit. Cardiol Young 2014:459-467
    • (2014) Cardiol Young , pp. 459-467
    • Tume, L.N.1    Arnold, P.2
  • 43
    • 77954957188 scopus 로고    scopus 로고
    • Relationship of intraoperative cerebral oxygen saturation to neurodevelopmental outcome and brain magnetic resonance imaging at 1 year of age in infants undergoing biventricular repair
    • Kussman BD, Wypij D, Laussen PC, et al: Relationship of intraoperative cerebral oxygen saturation to neurodevelopmental outcome and brain magnetic resonance imaging at 1 year of age in infants undergoing biventricular repair. Circulation 2010; 122:245-254
    • (2010) Circulation , vol.122 , pp. 245-254
    • Kussman, B.D.1    Wypij, D.2    Laussen, P.C.3
  • 44
    • 0036197902 scopus 로고    scopus 로고
    • Near-infrared spectroscopy cerebral oxygen saturation thresholds for hypoxia-ischemia in piglets
    • Kurth CD, Levy WJ, McCann J: Near-infrared spectroscopy cerebral oxygen saturation thresholds for hypoxia-ischemia in piglets. J Cereb Blood Flow Metab 2002; 22:335-341
    • (2002) J Cereb Blood Flow Metab , vol.22 , pp. 335-341
    • Kurth, C.D.1    Levy, W.J.2    McCann, J.3
  • 45
    • 0036796709 scopus 로고    scopus 로고
    • A comparison of cerebral oxygenation as measured by the NIRO 300 and the INVOS 5100 near-infrared spectrophotometers
    • Thavasothy M, Broadhead M, Elwell C, et al: A comparison of cerebral oxygenation as measured by the NIRO 300 and the INVOS 5100 Near-Infrared Spectrophotometers. Anaesthesia 2002; 57:999-1006
    • (2002) Anaesthesia , vol.57 , pp. 999-1006
    • Thavasothy, M.1    Broadhead, M.2    Elwell, C.3
  • 46
    • 33846446415 scopus 로고    scopus 로고
    • Measurements of optical pathlength using phase-resolved spectroscopy in patients undergoing cardiopulmonary bypass
    • Yoshitani K, Kawaguchi M, Okuno T, et al: Measurements of optical pathlength using phase-resolved spectroscopy in patients undergoing cardiopulmonary bypass. Anesth Analg 2007; 104:341-346
    • (2007) Anesth Analg , vol.104 , pp. 341-346
    • Yoshitani, K.1    Kawaguchi, M.2    Okuno, T.3
  • 47
    • 84887482905 scopus 로고    scopus 로고
    • Comparing near-infrared spectroscopy devices and their sensors for monitoring regional cerebral oxygen saturation in the neonate
    • Dix LM, van Bel F, Baerts W, et al: Comparing near-infrared spectroscopy devices and their sensors for monitoring regional cerebral oxygen saturation in the neonate. Pediatr Res 2013; 74:557-563
    • (2013) Pediatr Res , vol.74 , pp. 557-563
    • Dix, L.M.1    Van Bel, F.2    Baerts, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.