메뉴 건너뛰기




Volumn 103, Issue 9, 2014, Pages 934-938

Comparison of four near-infrared spectroscopy devices shows that they are only suitable for monitoring cerebral oxygenation trends in preterm infants

Author keywords

Brain monitoring; Extraction coefficient; Near infrared spectroscopy; Preterm infants; Regional oxygen saturation

Indexed keywords

ARTICLE; BIRTH WEIGHT; BRAIN OXYGEN CONSUMPTION; BRAIN TISSUE; CEREBRAL OXIMETER; CLINICAL ARTICLE; COMPARATIVE STUDY; CONTROLLED STUDY; FEMALE; GESTATIONAL AGE; HEMOGLOBIN BLOOD LEVEL; HUMAN; MALE; NEAR INFRARED SPECTROSCOPY; NEWBORN; NEWBORN MONITORING; PREMATURITY; PRIORITY JOURNAL; TISSUE OXYGENATION; BRAIN; DEVICES; METABOLISM;

EID: 84906937384     PISSN: 08035253     EISSN: 16512227     Source Type: Journal    
DOI: 10.1111/apa.12698     Document Type: Article
Times cited : (65)

References (18)
  • 1
    • 84888323997 scopus 로고    scopus 로고
    • Reference ranges for regional cerebral tissue oxygen saturation and fractional oxygen extraction in neonates during immediate transition after birth
    • Pichler G, Binder C, Avian A, Beckenbach E, Schmolzer GM, Urlesberger B,. Reference ranges for regional cerebral tissue oxygen saturation and fractional oxygen extraction in neonates during immediate transition after birth. J Pediatr 2013; 163: 1558-63.
    • (2013) J Pediatr , vol.163 , pp. 1558-1563
    • Pichler, G.1    Binder, C.2    Avian, A.3    Beckenbach, E.4    Schmolzer, G.M.5    Urlesberger, B.6
  • 2
    • 34547115253 scopus 로고    scopus 로고
    • Can tissue oxygenation index (TOI) and cotside neurophysiological variables predict outcome in depressed/asphyxiated newborn infants?
    • Zaramella P, Saraceni E, Freato F, Falcon E, Suppiej A, Milan A, et al. Can tissue oxygenation index (TOI) and cotside neurophysiological variables predict outcome in depressed/asphyxiated newborn infants? Early Human Dev 2007; 83: 483-9.
    • (2007) Early Human Dev , vol.83 , pp. 483-489
    • Zaramella, P.1    Saraceni, E.2    Freato, F.3    Falcon, E.4    Suppiej, A.5    Milan, A.6
  • 4
    • 33749320421 scopus 로고    scopus 로고
    • Validation of a noninvasive neonatal optical cerebral oximeter in veno-venous ECMO patients with a cephalad catheter
    • Rais-Bahrami K, Rivera O, Short BL,. Validation of a noninvasive neonatal optical cerebral oximeter in veno-venous ECMO patients with a cephalad catheter. J Perinatol 2006; 26: 628-35.
    • (2006) J Perinatol , vol.26 , pp. 628-635
    • Rais-Bahrami, K.1    Rivera, O.2    Short, B.L.3
  • 6
    • 84906935046 scopus 로고    scopus 로고
    • Cerebral oxygenation after birth - A comparison of INVOS and FORE-SIGHT NIRS oximeters
    • Hessel TW, Hyttel-Sorensen S, Greisen G,. Cerebral oxygenation after birth-a comparison of INVOS and FORE-SIGHT NIRS oximeters. Acta Paediatr 2014.
    • (2014) Acta Paediatr
    • Hessel, T.W.1    Hyttel-Sorensen, S.2    Greisen, G.3
  • 7
    • 0033773832 scopus 로고    scopus 로고
    • Brain perfusion monitoring with frequency-domain and continuous-wave near-infrared spectroscopy: A cross-correlation study in newborn piglets
    • Zhang G, Katz A, Alfano RR, Kofinas AD, Kofinas DA, Stubblefield PG, et al. Brain perfusion monitoring with frequency-domain and continuous-wave near-infrared spectroscopy: a cross-correlation study in newborn piglets. Phys Med Biol 2000; 45: 3143-58.
    • (2000) Phys Med Biol , vol.45 , pp. 3143-3158
    • Zhang, G.1    Katz, A.2    Alfano, R.R.3    Kofinas, A.D.4    Kofinas, D.A.5    Stubblefield, P.G.6
  • 9
    • 34547729783 scopus 로고    scopus 로고
    • Use of tissue oxygenation index and fractional tissue oxygen extraction as non-invasive parameters for cerebral oxygenation. A validation study in piglets
    • Naulaers G, Meyns B, Miserez M, Leunens V, Van Huffel S, Casaer P, et al. Use of tissue oxygenation index and fractional tissue oxygen extraction as non-invasive parameters for cerebral oxygenation. A validation study in piglets. Neonatology 2007; 92: 120-6.
    • (2007) Neonatology , vol.92 , pp. 120-126
    • Naulaers, G.1    Meyns, B.2    Miserez, M.3    Leunens, V.4    Van Huffel, S.5    Casaer, P.6
  • 10
    • 84887482905 scopus 로고    scopus 로고
    • Comparing near-infrared spectroscopy devices and their sensors for monitoring regional cerebral oxygen saturation in the neonate
    • Dix LM, van Bel F, Baerts W, Lemmers PM,. Comparing near-infrared spectroscopy devices and their sensors for monitoring regional cerebral oxygen saturation in the neonate. Pediatr Res 2013; 74: 557-63.
    • (2013) Pediatr Res , vol.74 , pp. 557-563
    • Dix, L.M.1    Van Bel, F.2    Baerts, W.3    Lemmers, P.M.4
  • 11
    • 84883554632 scopus 로고    scopus 로고
    • Dynamic evaluation of near-infrared peripheral oximetry in healthy volunteers: A comparison between INVOS and EQUANOX
    • Fellahi JL, Butin G, Fischer MO, Zamparini G, Gerard JL, Hanouz JL,. Dynamic evaluation of near-infrared peripheral oximetry in healthy volunteers: a comparison between INVOS and EQUANOX. J Crit Care 2013; 28: 881.e1-6.
    • (2013) J Crit Care , vol.28
    • Fellahi, J.L.1    Butin, G.2    Fischer, M.O.3    Zamparini, G.4    Gerard, J.L.5    Hanouz, J.L.6
  • 12
    • 84885019374 scopus 로고    scopus 로고
    • Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers
    • Bickler PE, Feiner JR, Rollins MD,. Factors affecting the performance of 5 cerebral oximeters during hypoxia in healthy volunteers. Anesth Analg 2013; 117: 813-23.
    • (2013) Anesth Analg , vol.117 , pp. 813-823
    • Bickler, P.E.1    Feiner, J.R.2    Rollins, M.D.3
  • 13
    • 84859111411 scopus 로고    scopus 로고
    • Impact of extracranial contamination on regional cerebral oxygen saturation: A comparison of three cerebral oximetry technologies
    • Davie SN, Grocott HP,. Impact of extracranial contamination on regional cerebral oxygen saturation: a comparison of three cerebral oximetry technologies. Anesthesiology 2012; 116: 834-40.
    • (2012) Anesthesiology , vol.116 , pp. 834-840
    • Davie, S.N.1    Grocott, H.P.2
  • 14
    • 21244490736 scopus 로고    scopus 로고
    • Comparison between cerebral tissue oxygenation index measured by near-infrared spectroscopy and venous jugular bulb saturation in children
    • Nagdyman N, Fleck T, Schubert S, Ewert P, Peters B, Lange PE, et al. Comparison between cerebral tissue oxygenation index measured by near-infrared spectroscopy and venous jugular bulb saturation in children. Intensive Care Med 2005; 31: 846-50.
    • (2005) Intensive Care Med , vol.31 , pp. 846-850
    • Nagdyman, N.1    Fleck, T.2    Schubert, S.3    Ewert, P.4    Peters, B.5    Lange, P.E.6
  • 15
    • 80455137274 scopus 로고    scopus 로고
    • Regional tissue oxygen saturation: Comparability and reproducibility of different devices
    • Pocivalnik M, Pichler G, Zotter H, Tax N, Muller W, Urlesberger B,. Regional tissue oxygen saturation: comparability and reproducibility of different devices. J Biomed Opt 2011; 16: 057004.
    • (2011) J Biomed Opt , vol.16 , pp. 057004
    • Pocivalnik, M.1    Pichler, G.2    Zotter, H.3    Tax, N.4    Muller, W.5    Urlesberger, B.6
  • 17
    • 84889635226 scopus 로고    scopus 로고
    • Does the resting state connectivity have hemispheric asymmetry? A near-infrared spectroscopy study
    • Medvedev AV,. Does the resting state connectivity have hemispheric asymmetry? A near-infrared spectroscopy study Neuroimage 2014; 85 (Pt 1): 400-7.
    • (2014) Neuroimage , vol.85 , Issue.PART 1 , pp. 400-407
    • Medvedev, A.V.1
  • 18
    • 37549034591 scopus 로고    scopus 로고
    • Cerebral laterality differences in handedness: A mental rotation study with NIRS
    • Shimoda N, Takeda K, Imai I, Kaneko J, Kato H,. Cerebral laterality differences in handedness: a mental rotation study with NIRS. Neurosci Lett 2008; 430: 43-7.
    • (2008) Neurosci Lett , vol.430 , pp. 43-47
    • Shimoda, N.1    Takeda, K.2    Imai, I.3    Kaneko, J.4    Kato, H.5