메뉴 건너뛰기




Volumn 9, Issue 1, 2016, Pages 64-66

Can a MR Imaging Scanner Accurately Measure Hematocrit to Determine ECV Fraction?

Author keywords

collagen; ECV; magnetic resonance imaging; mortality; myocardial fibrosis

Indexed keywords

GADOLINIUM; CONTRAST MEDIUM;

EID: 84952933959     PISSN: 1936878X     EISSN: 18767591     Source Type: Journal    
DOI: 10.1016/j.jcmg.2015.11.009     Document Type: Editorial
Times cited : (8)

References (20)
  • 1
    • 79951642225 scopus 로고    scopus 로고
    • Assessment of myocardial fibrosis with cardiovascular magnetic resonance
    • N. Mewton, C.Y. Liu, P. Croisille, D. Bluemke, and J.A. Lima Assessment of myocardial fibrosis with cardiovascular magnetic resonance J Am Coll Cardiol 57 2011 891 903
    • (2011) J Am Coll Cardiol , vol.57 , pp. 891-903
    • Mewton, N.1    Liu, C.Y.2    Croisille, P.3    Bluemke, D.4    Lima, J.A.5
  • 3
    • 0031182564 scopus 로고    scopus 로고
    • Proton NMR relaxation times of human blood samples at 1.5 T and implications for functional MRI
    • M. Barth, and E. Moser Proton NMR relaxation times of human blood samples at 1.5 T and implications for functional MRI Cell Mol Biol (Noisy-le-grand) 43 1997 783 791
    • (1997) Cell Mol Biol (Noisy-le-grand) , vol.43 , pp. 783-791
    • Barth, M.1    Moser, E.2
  • 4
    • 84876157733 scopus 로고    scopus 로고
    • Native T1 mapping in differentiation of normal myocardium from diffuse disease in hypertrophic and dilated cardiomyopathy
    • V.O. Puntmann, T. Voigt, Z. Chen, and et al. Native T1 mapping in differentiation of normal myocardium from diffuse disease in hypertrophic and dilated cardiomyopathy J Am Coll Cardiol Img 6 2013 475 484
    • (2013) J Am Coll Cardiol Img , vol.6 , pp. 475-484
    • Puntmann, V.O.1    Voigt, T.2    Chen, Z.3
  • 5
    • 85003045289 scopus 로고    scopus 로고
    • Reproducibility of native myocardial T1 mapping in the assessment of Fabry disease and its role in early detection of cardiac involvement by cardiovascular magnetic resonance
    • S. Pica, D.M. Sado, V. Maestrini, and et al. Reproducibility of native myocardial T1 mapping in the assessment of Fabry disease and its role in early detection of cardiac involvement by cardiovascular magnetic resonance J Cardiovasc Magn Reson 16 2014 99
    • (2014) J Cardiovasc Magn Reson , vol.16 , pp. 99
    • Pica, S.1    Sado, D.M.2    Maestrini, V.3
  • 7
    • 77954762396 scopus 로고    scopus 로고
    • Equilibrium contrast cardiovascular magnetic resonance for the measurement of diffuse myocardial fibrosis: Preliminary validation in humans
    • A.S. Flett, M.P. Hayward, M.T. Ashworth, and et al. Equilibrium contrast cardiovascular magnetic resonance for the measurement of diffuse myocardial fibrosis: preliminary validation in humans Circulation 122 2010 138 144
    • (2010) Circulation , vol.122 , pp. 138-144
    • Flett, A.S.1    Hayward, M.P.2    Ashworth, M.T.3
  • 8
    • 82955184487 scopus 로고    scopus 로고
    • Assessment of diffuse myocardial fibrosis in rats using small-animal Look-Locker inversion recovery T1 mapping
    • D.R. Messroghli, S. Nordmeyer, T. Dietrich, and et al. Assessment of diffuse myocardial fibrosis in rats using small-animal Look-Locker inversion recovery T1 mapping Circ Cardiovasc Imaging 4 2011 636 640
    • (2011) Circ Cardiovasc Imaging , vol.4 , pp. 636-640
    • Messroghli, D.R.1    Nordmeyer, S.2    Dietrich, T.3
  • 9
    • 84867149810 scopus 로고    scopus 로고
    • Normal left ventricular myocardial thickness for middle-aged and older subjects with steady-state free precession cardiac magnetic resonance: The multi-ethnic study of atherosclerosis
    • N. Kawel, E.B. Turkbey, J.J. Carr, and et al. Normal left ventricular myocardial thickness for middle-aged and older subjects with steady-state free precession cardiac magnetic resonance: the multi-ethnic study of atherosclerosis Circ Cardiovasc Imaging 5 2012 500 508
    • (2012) Circ Cardiovasc Imaging , vol.5 , pp. 500-508
    • Kawel, N.1    Turkbey, E.B.2    Carr, J.J.3
  • 10
    • 84866107331 scopus 로고    scopus 로고
    • Cardiovascular magnetic resonance measurement of myocardial extracellular volume in health and disease
    • D.M. Sado, A.S. Flett, S.M. Banypersad, and et al. Cardiovascular magnetic resonance measurement of myocardial extracellular volume in health and disease Heart 98 2012 1436 1441
    • (2012) Heart , vol.98 , pp. 1436-1441
    • Sado, D.M.1    Flett, A.S.2    Banypersad, S.M.3
  • 11
    • 84880225224 scopus 로고    scopus 로고
    • T1 measurements identify extracellular volume expansion in hypertrophic cardiomyopathy sarcomere mutation carriers with and without left ventricular hypertrophy
    • C.Y. Ho, S.A. Abbasi, T.G. Neilan, and et al. T1 measurements identify extracellular volume expansion in hypertrophic cardiomyopathy sarcomere mutation carriers with and without left ventricular hypertrophy Circ Cardiovasc Imaging 6 2013 415 422
    • (2013) Circ Cardiovasc Imaging , vol.6 , pp. 415-422
    • Ho, C.Y.1    Abbasi, S.A.2    Neilan, T.G.3
  • 12
    • 84873723130 scopus 로고    scopus 로고
    • Myocardial extracellular volume by cardiac magnetic resonance imaging in patients treated with anthracycline-based chemotherapy
    • T.G. Neilan, O.R. Coelho-Filho, R.V. Shah, and et al. Myocardial extracellular volume by cardiac magnetic resonance imaging in patients treated with anthracycline-based chemotherapy Am J Cardiol 111 2013 717 722
    • (2013) Am J Cardiol , vol.111 , pp. 717-722
    • Neilan, T.G.1    Coelho-Filho, O.R.2    Shah, R.V.3
  • 13
    • 84865863380 scopus 로고    scopus 로고
    • Association between extracellular matrix expansion quantified by cardiovascular magnetic resonance and short-term mortality
    • T.C. Wong, K. Piehler, C.G. Meier, and et al. Association between extracellular matrix expansion quantified by cardiovascular magnetic resonance and short-term mortality Circulation 126 2012 1206 1216
    • (2012) Circulation , vol.126 , pp. 1206-1216
    • Wong, T.C.1    Piehler, K.2    Meier, C.G.3
  • 14
    • 84872914836 scopus 로고    scopus 로고
    • Diffuse myocardial fibrosis evaluation using cardiac magnetic resonance T1 mapping: Sample size considerations for clinical trials
    • S. Liu, J. Han, M.S. Nacif, and et al. Diffuse myocardial fibrosis evaluation using cardiac magnetic resonance T1 mapping: sample size considerations for clinical trials J Cardiovasc Magn Reson 14 2012 90
    • (2012) J Cardiovasc Magn Reson , vol.14 , pp. 90
    • Liu, S.1    Han, J.2    Nacif, M.S.3
  • 15
    • 84885338673 scopus 로고    scopus 로고
    • Myocardial T1 mapping and extracellular volume quantification: A Society for Cardiovascular Magnetic Resonance (SCMR) and CMR Working Group of the European Society of Cardiology consensus statement
    • J.C. Moon, D.R. Messroghli, P. Kellman, and et al. Myocardial T1 mapping and extracellular volume quantification: a Society for Cardiovascular Magnetic Resonance (SCMR) and CMR Working Group of the European Society of Cardiology consensus statement J Cardiovasc Magn Reson 15 2013 92
    • (2013) J Cardiovasc Magn Reson , vol.15 , pp. 92
    • Moon, J.C.1    Messroghli, D.R.2    Kellman, P.3
  • 16
    • 84952924432 scopus 로고    scopus 로고
    • Automatic measurement of the myocardial interstitium: Synthetic extracellular volume quantification without hematocrit sampling
    • T.A. Treibel, M. Fontana, V. Maestrini, and et al. Automatic measurement of the myocardial interstitium: synthetic extracellular volume quantification without hematocrit sampling J Am Coll Cardiol Img 9 2016 54 63
    • (2016) J Am Coll Cardiol Img , vol.9 , pp. 54-63
    • Treibel, T.A.1    Fontana, M.2    Maestrini, V.3
  • 17
    • 4243184848 scopus 로고    scopus 로고
    • Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
    • H. Lu, C. Clingman, X. Golay, and P.C. van Zijl Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla Magn Reson Med 52 2004 679 682
    • (2004) Magn Reson Med , vol.52 , pp. 679-682
    • Lu, H.1    Clingman, C.2    Golay, X.3    Van Zijl, P.C.4
  • 18
    • 0028955605 scopus 로고
    • Analytical artifacts in hematocrit measurements by whole-blood chemistry analyzers
    • R.A. Stott, G.L. Hortin, T.R. Wilhite, S.B. Miller, C.H. Smith, and M. Landt Analytical artifacts in hematocrit measurements by whole-blood chemistry analyzers Clin Chem 41 1995 306 311
    • (1995) Clin Chem , vol.41 , pp. 306-311
    • Stott, R.A.1    Hortin, G.L.2    Wilhite, T.R.3    Miller, S.B.4    Smith, C.H.5    Landt, M.6
  • 19
    • 0034052995 scopus 로고    scopus 로고
    • How valid is the determination of hematocrit values to detect blood manipulations?
    • W. Schmidt, B. Biermann, P. Winchenbach, S. Lison, and D. Boning How valid is the determination of hematocrit values to detect blood manipulations? Int J Sports Med 21 2000 133 138
    • (2000) Int J Sports Med , vol.21 , pp. 133-138
    • Schmidt, W.1    Biermann, B.2    Winchenbach, P.3    Lison, S.4    Boning, D.5
  • 20
    • 0005917340 scopus 로고
    • Diurnal, postural and postprandial variations of hematocrit
    • G.A. Mayer Diurnal, postural and postprandial variations of hematocrit Can Med Assoc J 93 1965 1006 1008
    • (1965) Can Med Assoc J , vol.93 , pp. 1006-1008
    • Mayer, G.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.