메뉴 건너뛰기




Volumn 34, Issue 1, 2016, Pages 18-25

Isotropic 3D black blood MRI of abdominal aortic aneurysm wall and intraluminal thrombus

Author keywords

3D black blood; Abdominal aortic aneurysm; Blood suppression; Intra luminal thrombus; Vessel wall MRI

Indexed keywords

ABDOMINAL AORTA ANEURYSM; AGED; AORTA WALL; ARTICLE; ARTIFACT; CLINICAL ARTICLE; CONTRAST TO NOISE RATIO; CONTROLLED STUDY; HUMAN; IMAGE QUALITY; INTRALUMINAL THROMBUS; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PSOAS MUSCLE; RISK ASSESSMENT; SIGNAL NOISE RATIO; THREE DIMENSIONAL IMAGING; THROMBUS; ALGORITHM; ANISOTROPY; AORTA VALVE STENOSIS; COMPLICATION; COMPUTER ASSISTED DIAGNOSIS; IMAGE ENHANCEMENT; MAGNETIC RESONANCE ANGIOGRAPHY; PATHOLOGY; PROCEDURES; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; THROMBOSIS;

EID: 84952791285     PISSN: 0730725X     EISSN: 18735894     Source Type: Journal    
DOI: 10.1016/j.mri.2015.10.002     Document Type: Article
Times cited : (31)

References (22)
  • 2
    • 0038710648 scopus 로고    scopus 로고
    • Guidelines for the treatment of abdominal aortic aneurysms. Report of a subcommittee of the Joint Council of the American Association for Vascular Surgery and Society for Vascular Surgery
    • Brewster D.C., Cronenwett J.L., Hallett J.W., Johnston K.W., Krupski W.C., Matsumura J.S. Guidelines for the treatment of abdominal aortic aneurysms. Report of a subcommittee of the Joint Council of the American Association for Vascular Surgery and Society for Vascular Surgery. J Vasc Surg 2003, 37:1106-1117.
    • (2003) J Vasc Surg , vol.37 , pp. 1106-1117
    • Brewster, D.C.1    Cronenwett, J.L.2    Hallett, J.W.3    Johnston, K.W.4    Krupski, W.C.5    Matsumura, J.S.6
  • 3
    • 82455194960 scopus 로고    scopus 로고
    • Improved risk assessment for abdominal aortic aneurysm rupture: off-the-wall imaging
    • Hope T.A., Hope M.D. Improved risk assessment for abdominal aortic aneurysm rupture: off-the-wall imaging. J Am Coll Cardiol 2011, 58:2531-2532.
    • (2011) J Am Coll Cardiol , vol.58 , pp. 2531-2532
    • Hope, T.A.1    Hope, M.D.2
  • 4
    • 13244270204 scopus 로고    scopus 로고
    • Screening for abdominal aortic aneurysm: recommendation statement
    • Screening for abdominal aortic aneurysm: recommendation statement. Ann Intern Med 2005, 142:198-202.
    • (2005) Ann Intern Med , vol.142 , pp. 198-202
  • 5
    • 84919451168 scopus 로고    scopus 로고
    • Abdominal aortic aneurysms with high thrombus signal intensity on magnetic resonance imaging are associated with high growth rate
    • Nguyen V.L., Leiner T., Hellenthal F.A., Backes W.H., Wishaupt M.C., van der Geest R.J., et al. Abdominal aortic aneurysms with high thrombus signal intensity on magnetic resonance imaging are associated with high growth rate. Eur J Vasc Endovasc Surg 2014, 48:676-684.
    • (2014) Eur J Vasc Endovasc Surg , vol.48 , pp. 676-684
    • Nguyen, V.L.1    Leiner, T.2    Hellenthal, F.A.3    Backes, W.H.4    Wishaupt, M.C.5    van der Geest, R.J.6
  • 6
    • 79960205627 scopus 로고    scopus 로고
    • Abdominal aortic aneurysm growth predicted by uptake of ultrasmall superparamagnetic particles of iron oxide: a pilot study
    • Richards J.M., Semple S.I., MacGillivray T.J., Gray C., Langrish J.P., Williams M., et al. Abdominal aortic aneurysm growth predicted by uptake of ultrasmall superparamagnetic particles of iron oxide: a pilot study. Circ Cardiovasc Imaging 2011, 4:274-281.
    • (2011) Circ Cardiovasc Imaging , vol.4 , pp. 274-281
    • Richards, J.M.1    Semple, S.I.2    MacGillivray, T.J.3    Gray, C.4    Langrish, J.P.5    Williams, M.6
  • 7
    • 51449085600 scopus 로고    scopus 로고
    • Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo
    • Busse R.F., Brau A.C., Vu A., Michelich C.R., Bayram E., Kijowski R., et al. Effects of refocusing flip angle modulation and view ordering in 3D fast spin echo. Magn Reson Med 2008, 60:640-649.
    • (2008) Magn Reson Med , vol.60 , pp. 640-649
    • Busse, R.F.1    Brau, A.C.2    Vu, A.3    Michelich, C.R.4    Bayram, E.5    Kijowski, R.6
  • 8
    • 0033035836 scopus 로고    scopus 로고
    • Voxel sensitivity function description of flow-induced signal loss in MR imaging: implications for black-blood MR angiography with turbo spin-echo sequences
    • Jara H., Yu B.C., Caruthers S.D., Melhem E.R., Yucel E.K. Voxel sensitivity function description of flow-induced signal loss in MR imaging: implications for black-blood MR angiography with turbo spin-echo sequences. Magn Reson Med 1999, 41:575-590.
    • (1999) Magn Reson Med , vol.41 , pp. 575-590
    • Jara, H.1    Yu, B.C.2    Caruthers, S.D.3    Melhem, E.R.4    Yucel, E.K.5
  • 9
    • 75749136951 scopus 로고    scopus 로고
    • T1-weighted-SPACE dark blood whole body magnetic resonance angiography (DB-WBMRA): initial experience
    • Mihai G., Chung Y.C., Merchant A., Simonetti O.P., Rajagopalan S. T1-weighted-SPACE dark blood whole body magnetic resonance angiography (DB-WBMRA): initial experience. J Magn Reson Imaging 2010, 31:502-509.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 502-509
    • Mihai, G.1    Chung, Y.C.2    Merchant, A.3    Simonetti, O.P.4    Rajagopalan, S.5
  • 10
    • 84919352931 scopus 로고    scopus 로고
    • Reproducibility of thoracic and abdominal aortic wall measurements with three-dimensional, variable flip angle (SPACE) MRI
    • Mihai G., Varghese J., Lu B., Zhu H., Simonetti O.P., Rajagopalan S. Reproducibility of thoracic and abdominal aortic wall measurements with three-dimensional, variable flip angle (SPACE) MRI. J Magn Reson Imaging 2015, 41:202-212.
    • (2015) J Magn Reson Imaging , vol.41 , pp. 202-212
    • Mihai, G.1    Varghese, J.2    Lu, B.3    Zhu, H.4    Simonetti, O.P.5    Rajagopalan, S.6
  • 12
    • 77649197700 scopus 로고    scopus 로고
    • Carotid arterial wall MRI at 3T using 3D variable-flip-angle turbo spin-echo (TSE) with flow-sensitive dephasing (FSD)
    • Fan Z., Zhang Z., Chung Y.C., Weale P., Zuehlsdorff S., Carr J., et al. Carotid arterial wall MRI at 3T using 3D variable-flip-angle turbo spin-echo (TSE) with flow-sensitive dephasing (FSD). J Magn Reson Imaging 2010, 31:645-654.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 645-654
    • Fan, Z.1    Zhang, Z.2    Chung, Y.C.3    Weale, P.4    Zuehlsdorff, S.5    Carr, J.6
  • 13
    • 84867864961 scopus 로고    scopus 로고
    • DANTE-prepared pulse trains: a novel approach to motion-sensitized and motion-suppressed quantitative magnetic resonance imaging
    • Li L., Miller K.L., Jezzard P. DANTE-prepared pulse trains: a novel approach to motion-sensitized and motion-suppressed quantitative magnetic resonance imaging. Magn Reson Med 2012, 68:1423-1438.
    • (2012) Magn Reson Med , vol.68 , pp. 1423-1438
    • Li, L.1    Miller, K.L.2    Jezzard, P.3
  • 14
    • 85019284497 scopus 로고    scopus 로고
    • 2D and 3D multi-contrast black blood carotid vessel wall imaging applying DANTE preparation
    • Zhu C., Patterson A., Graves M., Gillard J. 2D and 3D multi-contrast black blood carotid vessel wall imaging applying DANTE preparation. Proc Intl Soc Mag Reson Med 2014, 22:2538.
    • (2014) Proc Intl Soc Mag Reson Med , vol.22 , pp. 2538
    • Zhu, C.1    Patterson, A.2    Graves, M.3    Gillard, J.4
  • 15
    • 84907675207 scopus 로고    scopus 로고
    • Mural thrombus and the progression of abdominal aortic aneurysms: a large population-based prospective cohort study
    • Behr-Rasmussen C., Grondal N., Bramsen M.B., Thomsen M.D., Lindholt J.S. Mural thrombus and the progression of abdominal aortic aneurysms: a large population-based prospective cohort study. Eur J Vasc Endovasc Surg 2014, 48:301-307.
    • (2014) Eur J Vasc Endovasc Surg , vol.48 , pp. 301-307
    • Behr-Rasmussen, C.1    Grondal, N.2    Bramsen, M.B.3    Thomsen, M.D.4    Lindholt, J.S.5
  • 16
    • 84897024368 scopus 로고    scopus 로고
    • Optimized three-dimensional fast-spin-echo MRI
    • Mugler J.P. Optimized three-dimensional fast-spin-echo MRI. J Magn Reson Imaging 2014, 39:745-767.
    • (2014) J Magn Reson Imaging , vol.39 , pp. 745-767
    • Mugler, J.P.1
  • 17
    • 84910080490 scopus 로고    scopus 로고
    • Black-blood multicontrast imaging of carotid arteries with DANTE-prepared 2D and 3D MR imaging
    • Li L., Chai J.T., Biasiolli L., Robson M.D., Choudhury R.P., Handa A.I., et al. Black-blood multicontrast imaging of carotid arteries with DANTE-prepared 2D and 3D MR imaging. Radiology 2014, 273:560-569.
    • (2014) Radiology , vol.273 , pp. 560-569
    • Li, L.1    Chai, J.T.2    Biasiolli, L.3    Robson, M.D.4    Choudhury, R.P.5    Handa, A.I.6
  • 18
    • 55749111367 scopus 로고    scopus 로고
    • On the overestimation of early wall thickening at the carotid bulb by black blood MRI, with implications for coronary and vulnerable plaque imaging
    • Antiga L., Wasserman B.A., Steinman D.A. On the overestimation of early wall thickening at the carotid bulb by black blood MRI, with implications for coronary and vulnerable plaque imaging. Magn Reson Med 2008, 60:1020-1028.
    • (2008) Magn Reson Med , vol.60 , pp. 1020-1028
    • Antiga, L.1    Wasserman, B.A.2    Steinman, D.A.3
  • 20
    • 79959610781 scopus 로고    scopus 로고
    • Intracranial arterial wall imaging using three-dimensional high isotropic resolution black blood MRI at 3.0 Tesla
    • Qiao Y., Steinman D.A., Qin Q., Etesami M., Schar M., Astor B.C., et al. Intracranial arterial wall imaging using three-dimensional high isotropic resolution black blood MRI at 3.0 Tesla. J Magn Reson Imaging 2011, 34:22-30.
    • (2011) J Magn Reson Imaging , vol.34 , pp. 22-30
    • Qiao, Y.1    Steinman, D.A.2    Qin, Q.3    Etesami, M.4    Schar, M.5    Astor, B.C.6
  • 21
    • 84924351951 scopus 로고    scopus 로고
    • Fast 3D isotropic imaging of the aortic vessel wall by application of 2D spatially selective excitation and a new way of inversion recovery for black blood imaging
    • [Epub ahead of print]
    • Mooiweer R., Sbrizzi A., El Aidi H., Eikendal A.L., Raaijmakers A., Visser F., et al. Fast 3D isotropic imaging of the aortic vessel wall by application of 2D spatially selective excitation and a new way of inversion recovery for black blood imaging. Magn Reson Med 2015, [Epub ahead of print]. 10.1002/mrm.25599.
    • (2015) Magn Reson Med
    • Mooiweer, R.1    Sbrizzi, A.2    El Aidi, H.3    Eikendal, A.L.4    Raaijmakers, A.5    Visser, F.6
  • 22
    • 0031894283 scopus 로고    scopus 로고
    • Reduced pulsatile wall motion of abdominal aortic aneurysms after endovascular repair
    • Malina M., Lanne T., Ivancev K., Lindblad B., Brunkwall J. Reduced pulsatile wall motion of abdominal aortic aneurysms after endovascular repair. J Vasc Surg 1998, 27:624-631.
    • (1998) J Vasc Surg , vol.27 , pp. 624-631
    • Malina, M.1    Lanne, T.2    Ivancev, K.3    Lindblad, B.4    Brunkwall, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.