-
1
-
-
0031899393
-
On the nature and reduction of plaque-mimicking flow artifacts in black blood MRI of the carotid bifurcation
-
Steinman DA, Rutt BK. On the nature and reduction of plaque-mimicking flow artifacts in black blood MRI of the carotid bifurcation. Magn Reson Med 1998;39(4): 635-641.
-
(1998)
Magn Reson Med
, vol.39
, Issue.4
, pp. 635-641
-
-
Steinman, D.A.1
Rutt, B.K.2
-
2
-
-
0034756429
-
Carotid atherosclerotic plaque: Noninvasive MR characterization and identification of vulnerable lesions
-
Yuan C, Mitsumori LM, Beach KW, Maravilla KR. Carotid atherosclerotic plaque: noninvasive MR characterization and identification of vulnerable lesions. Radiology 2001;221(2):285-299.
-
(2001)
Radiology
, vol.221
, Issue.2
, pp. 285-299
-
-
Yuan, C.1
Mitsumori, L.M.2
Beach, K.W.3
Maravilla, K.R.4
-
3
-
-
84859613610
-
Plaque features associated with increased cerebral infarction after minor stroke and TIA: A prospective, case-control, 3-T carotid artery MR imaging study
-
Lindsay AC, Biasiolli L, Lee JM, et al. Plaque features associated with increased cerebral infarction after minor stroke and TIA: A prospective, case-control, 3-T carotid artery MR imaging study. JACC Cardiovasc Imaging 2012;5(4):388-396.
-
(2012)
JACC Cardiovasc Imaging
, vol.5
, Issue.4
, pp. 388-396
-
-
Lindsay, A.C.1
Biasiolli, L.2
Lee, J.M.3
-
4
-
-
0037080880
-
Identification of fibrous cap rupture with magnetic resonance imaging is highly associated with recent transient ischemic attack or stroke
-
Yuan C, Zhang SX, Polissar NL, et al. Identification of fibrous cap rupture with magnetic resonance imaging is highly associated with recent transient ischemic attack or stroke. Circulation 2002;105(2):181-185.
-
(2002)
Circulation
, vol.105
, Issue.2
, pp. 181-185
-
-
Yuan, C.1
Zhang, S.X.2
Polissar, N.L.3
-
5
-
-
0037056102
-
Classification of human carotid atherosclerotic lesions with in vivo multicontrast magnetic resonance imaging
-
Cai JM, Hatsukami TS, Ferguson MS, Small R, Polissar NL, Yuan C. Classification of human carotid atherosclerotic lesions with in vivo multicontrast magnetic resonance imaging. Circulation 2002;106(11):1368-1373.
-
(2002)
Circulation
, vol.106
, Issue.11
, pp. 1368-1373
-
-
Cai, J.M.1
Hatsukami, T.S.2
Ferguson, M.S.3
Small, R.4
Polissar, N.L.5
Yuan, C.6
-
6
-
-
0035940373
-
In vivo accuracy of multispectral magnetic resonance imaging for identifying lipid-rich necrotic cores and intraplaque hemorrhage in advanced human carotid plaques
-
Yuan C, Mitsumori LM, Ferguson MS, et al. In vivo accuracy of multispectral magnetic resonance imaging for identifying lipid-rich necrotic cores and intraplaque hemorrhage in advanced human carotid plaques. Circulation 2001;104(17):2051-2056.
-
(2001)
Circulation
, vol.104
, Issue.17
, pp. 2051-2056
-
-
Yuan, C.1
Mitsumori, L.M.2
Ferguson, M.S.3
-
7
-
-
0025163595
-
Extracranial carotid arteries: Evaluation with "black blood" MR angiography
-
Edelman RR, Mattle HP, Wallner B, et al. Extracranial carotid arteries: evaluation with "black blood" MR angiography. Radiology 1990;177(1):45-50.
-
(1990)
Radiology
, vol.177
, Issue.1
, pp. 45-50
-
-
Edelman, R.R.1
Mattle, H.P.2
Wallner, B.3
-
8
-
-
0026320313
-
Fast selective black blood MR imaging
-
Edelman RR, Chien D, Kim D. Fast selective black blood MR imaging. Radiology 1991;181(3):655-660.
-
(1991)
Radiology
, vol.181
, Issue.3
, pp. 655-660
-
-
Edelman, R.R.1
Chien, D.2
Kim, D.3
-
9
-
-
2942705883
-
Rapid extended coverage simultaneous multisection black-blood vessel wall MR imaging
-
Mani V, Itskovich VV, Szimtenings M, et al. Rapid extended coverage simultaneous multisection black-blood vessel wall MR imaging. Radiology 2004;232(1):281-288.
-
(2004)
Radiology
, vol.232
, Issue.1
, pp. 281-288
-
-
Mani, V.1
Itskovich, V.V.2
Szimtenings, M.3
-
10
-
-
0036184749
-
Multislice double inversion pulse sequence for efficient black-blood MRI
-
Song HK, Wright AC, Wolf RL, Wehrli FW. Multislice double inversion pulse sequence for efficient black-blood MRI. Magn Reson Med 2002;47(3):616-620.
-
(2002)
Magn Reson Med
, vol.47
, Issue.3
, pp. 616-620
-
-
Song, H.K.1
Wright, A.C.2
Wolf, R.L.3
Wehrli, F.W.4
-
11
-
-
0036234729
-
Improved efficiency in double-inversion fast spin-echo imaging
-
Parker DL, Goodrich KC, Masiker M, Tsuruda JS, Katzman GL. Improved efficiency in double-inversion fast spin-echo imaging. Magn Reson Med 2002;47(5):1017-1021.
-
(2002)
Magn Reson Med
, vol.47
, Issue.5
, pp. 1017-1021
-
-
Parker, D.L.1
Goodrich, K.C.2
Masiker, M.3
Tsuruda, J.S.4
Katzman, G.L.5
-
12
-
-
34147195477
-
Three-dimensional black-blood MR imaging of carotid arteries with segmented steady-state free precession: Initial experience
-
Koktzoglou I, Chung YC, Carroll TJ, Simonetti OP, Morasch MD, Li D. Three-dimensional black-blood MR imaging of carotid arteries with segmented steady-state free precession: initial experience. Radiology 2007;243(1):220-228.
-
(2007)
Radiology
, vol.243
, Issue.1
, pp. 220-228
-
-
Koktzoglou, I.1
Chung, Y.C.2
Carroll, T.J.3
Simonetti, O.P.4
Morasch, M.D.5
Li, D.6
-
13
-
-
33845904636
-
Diffusion-prepared segmented steady-state free precession: Application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls
-
Koktzoglou I, Li D. Diffusion-prepared segmented steady-state free precession: Application to 3D black-blood cardiovascular magnetic resonance of the thoracic aorta and carotid artery walls. J Cardiovasc Magn Reson 2007;9(1):33-42.
-
(2007)
J Cardiovasc Magn Reson
, vol.9
, Issue.1
, pp. 33-42
-
-
Koktzoglou, I.1
Li, D.2
-
14
-
-
34748912279
-
Dark-blood MRI of the thoracic aorta with 3D diffusion-prepared steadystate free precession: Initial clinical evaluation
-
Koktzoglou I, Kirpalani A, Carroll TJ, Li D, Carr JC. Dark-blood MRI of the thoracic aorta with 3D diffusion-prepared steadystate free precession: initial clinical evaluation. AJR Am J Roentgenol 2007;189(4): 966-972.
-
(2007)
AJR Am J Roentgenol
, vol.189
, Issue.4
, pp. 966-972
-
-
Koktzoglou, I.1
Kirpalani, A.2
Carroll, T.J.3
Li, D.4
Carr, J.C.5
-
15
-
-
35948971057
-
Improved suppression of plaque-mimicking artifacts in black-blood carotid atherosclerosis imaging using a multislice motion-sensitized driven-equilibrium (MSDE) turbo spin-echo (TSE) sequence
-
Wang J, Yarnykh VL, Hatsukami T, Chu B, Balu N, Yuan C. Improved suppression of plaque-mimicking artifacts in black-blood carotid atherosclerosis imaging using a multislice motion-sensitized driven-equilibrium (MSDE) turbo spin-echo (TSE) sequence. Magn Reson Med 2007;58(5):973-981.
-
(2007)
Magn Reson Med
, vol.58
, Issue.5
, pp. 973-981
-
-
Wang, J.1
Yarnykh, V.L.2
Hatsukami, T.3
Chu, B.4
Balu, N.5
Yuan, C.6
-
16
-
-
77951549426
-
Enhanced image quality in black-blood MRI using the improved motion-sensitized driven-equilibrium (iMSDE) sequence
-
Wang J, Yarnykh VL, Yuan C. Enhanced image quality in black-blood MRI using the improved motion-sensitized driven-equilibrium (iMSDE) sequence. J Magn Reson Imaging 2010;31(5):1256-1263.
-
(2010)
J Magn Reson Imaging
, vol.31
, Issue.5
, pp. 1256-1263
-
-
Wang, J.1
Yarnykh, V.L.2
Yuan, C.3
-
17
-
-
84863371233
-
Segmentation of carotid plaque using multicontrast 3D gradient echo MRI
-
Liu W, Balu N, Sun J, et al. Segmentation of carotid plaque using multicontrast 3D gradient echo MRI. J Magn Reson Imaging 2012; 35(4):812-819.
-
(2012)
J Magn Reson Imaging
, vol.35
, Issue.4
, pp. 812-819
-
-
Liu, W.1
Balu, N.2
Sun, J.3
-
18
-
-
78650346329
-
Carotid plaque assessment using fast 3D isotropic resolution blackblood MRI
-
Balu N, Yarnykh VL, Chu B, Wang J, Hatsukami T, Yuan C. Carotid plaque assessment using fast 3D isotropic resolution blackblood MRI. Magn Reson Med 2011;65(3): 627-637.
-
(2011)
Magn Reson Med
, vol.65
, Issue.3
, pp. 627-637
-
-
Balu, N.1
Yarnykh, V.L.2
Chu, B.3
Wang, J.4
Hatsukami, T.5
Yuan, C.6
-
19
-
-
84882441443
-
In-vivo quantitative T2 mapping of carotid arteries in atherosclerotic patients: Segmentation and T2 measurement of plaque components
-
Biasiolli L, Lindsay AC, Chai JT, Choudhury RP, Robson MD. In-vivo quantitative T2 mapping of carotid arteries in atherosclerotic patients: segmentation and T2 measurement of plaque components. J Cardiovasc Magn Reson 2013;15(1):69.
-
(2013)
J Cardiovasc Magn Reson
, vol.15
, Issue.1
, pp. 69
-
-
Biasiolli, L.1
Lindsay, A.C.2
Chai, J.T.3
Choudhury, R.P.4
Robson, M.D.5
-
20
-
-
84867864961
-
DANTE-prepared pulse trains: A novel approach to motionsensitized and motion-suppressed quantitative magnetic resonance imaging
-
Li L, Miller KL, Jezzard P. DANTE-prepared pulse trains: A novel approach to motionsensitized and motion-suppressed quantitative magnetic resonance imaging. Magn Reson Med 2012;68(5):1423-1438.
-
(2012)
Magn Reson Med
, vol.68
, Issue.5
, pp. 1423-1438
-
-
Li, L.1
Miller, K.L.2
Jezzard, P.3
-
21
-
-
84910073306
-
Improving 3D MERGE black-blood imaging using an additional time delay and compressed sensing [abstr]
-
Berkeley, Calif: International Society for Magnetic Resonance in Medicine
-
Li B, Dong L, Zhang Y, et al. Improving 3D MERGE black-blood imaging using an additional time delay and compressed sensing [abstr]. In: Proceedings of the Twenty-First Meeting of the International Society for Magnetic Resonance in Medicine. Berkeley, Calif: International Society for Magnetic Resonance in Medicine, 2013; ###.
-
(2013)
Proceedings of the Twenty-First Meeting of the International Society for Magnetic Resonance in Medicine
-
-
Li, B.1
Dong, L.2
Zhang, Y.3
-
22
-
-
84910067994
-
DANTE preparation for black-blood coronary wall imaging
-
Wang M, Kramer CM, Meyer CH. DANTE preparation for black-blood coronary wall imaging. J Cardiovasc Magn Reson 2013;15(Suppl 1):P237.
-
(2013)
J Cardiovasc Magn Reson
, vol.15
, pp. 237
-
-
Wang, M.1
Kramer, C.M.2
Meyer, C.H.3
-
23
-
-
0000629553
-
Phase and intensity anomalies in Fourier transform NMR
-
Freeman R, Hill HD. Phase and intensity anomalies in Fourier transform NMR. J Magn Reson 1971;4(3):366-383.
-
(1971)
J Magn Reson
, vol.4
, Issue.3
, pp. 366-383
-
-
Freeman, R.1
Hill, H.D.2
|