-
1
-
-
37549049393
-
Volumetric modulated arc therapy: IMRT in a single gantry arc
-
Otto K. Volumetric modulated arc therapy: IMRT in a single gantry arc. Med Phys. 2008;35(1):310-17.
-
(2008)
Med Phys
, vol.35
, Issue.1
, pp. 310-317
-
-
Otto, K.1
-
2
-
-
84868305126
-
Impact of gamma analysis parameters on dose evaluation using Gafchromic EBT2 films
-
Lee SR, Park JY, Suh TS, Park HJ, Lee JW, Jung WG. Impact of gamma analysis parameters on dose evaluation using Gafchromic EBT2 films. J Korean Phys Soc. 2012;61(8):1319-24.
-
(2012)
J Korean Phys Soc
, vol.61
, Issue.8
, pp. 1319-1324
-
-
Lee, S.R.1
Park, J.Y.2
Suh, T.S.3
Park, H.J.4
Lee, J.W.5
Jung, W.G.6
-
3
-
-
84927626677
-
A study on correlation between 2D and 3D gamma evaluation metrics in patient-specific quality assurance for VMAT
-
Rajasekaran D, Jeevanandam P, Sukumar P, Ranganathan A, Johnjothi S, Nagarajan V. A study on correlation between 2D and 3D gamma evaluation metrics in patient-specific quality assurance for VMAT. Med Dosim. 2014;39(4):300-08.
-
(2014)
Med Dosim
, vol.39
, Issue.4
, pp. 300-308
-
-
Rajasekaran, D.1
Jeevanandam, P.2
Sukumar, P.3
Ranganathan, A.4
Johnjothi, S.5
Nagarajan, V.6
-
4
-
-
58149345036
-
Commissioning of volumetric modulated arc therapy (VMAT)
-
Bedford JL and Warrington AP. Commissioning of volumetric modulated arc therapy (VMAT). Int J Radiat Oncol Biol Phys. 2009;73(2):537-45.
-
(2009)
Int J Radiat Oncol Biol Phys
, vol.73
, Issue.2
, pp. 537-545
-
-
Bedford, J.L.1
Warrington, A.P.2
-
5
-
-
84867325331
-
Is RapidArc more susceptible to delivery uncertainties than dynamic IMRT?
-
Betzel GT, Yi BY, Niu Y, Yu CX. Is RapidArc more susceptible to delivery uncertainties than dynamic IMRT? Med Phys. 2012;39(10):5882-90.
-
(2012)
Med Phys
, vol.39
, Issue.10
, pp. 5882-5890
-
-
Betzel, G.T.1
Yi, B.Y.2
Niu, Y.3
Yu, C.X.4
-
6
-
-
84881650423
-
3D EPID based dosimetry for pre-treatment verification of VMAT-methods and challenges
-
Greer PB. 3D EPID based dosimetry for pre-treatment verification of VMAT-methods and challenges. J Phys: Conf Ser. 2013;444(1):012010.
-
(2013)
J Phys: Conf Ser
, vol.444
, Issue.1
-
-
Greer, P.B.1
-
7
-
-
84890121955
-
A comparison of the gamma index analysis in various commercial IMRT/VMAT QA systems
-
Hussein M, Rowshanfarzad P, Ebert MA, Nisbet A, Clark CH. A comparison of the gamma index analysis in various commercial IMRT/VMAT QA systems. Radiother Oncol. 2013;109(3):370-76.
-
(2013)
Radiother Oncol
, vol.109
, Issue.3
, pp. 370-376
-
-
Hussein, M.1
Rowshanfarzad, P.2
Ebert, M.A.3
Nisbet, A.4
Clark, C.H.5
-
8
-
-
84864240475
-
Comparison of action levels for patient-specific quality assurance of intensity modulated radiation therapy and volumetric modulated arc therapy treatments
-
Mancuso GM, Fontenot JD, Gibbons JP, Parker BC. Comparison of action levels for patient-specific quality assurance of intensity modulated radiation therapy and volumetric modulated arc therapy treatments. Med Phys. 2012;39(7):4378-85.
-
(2012)
Med Phys
, vol.39
, Issue.7
, pp. 4378-4385
-
-
Mancuso, G.M.1
Fontenot, J.D.2
Gibbons, J.P.3
Parker, B.C.4
-
9
-
-
79952141409
-
Using an EPID for patient-specific VMAT quality assurance
-
Bakhtiari M, Kumaraswamy L, Bailey DW, de Boer S, Malhotra HK, Podgorsak MB. Using an EPID for patient-specific VMAT quality assurance. Med Phys. 2011;38(3):1366-73.
-
(2011)
Med Phys
, vol.38
, Issue.3
, pp. 1366-1373
-
-
Bakhtiari, M.1
Kumaraswamy, L.2
Bailey, D.W.3
de Boer, S.4
Malhotra, H.K.5
Podgorsak, M.B.6
-
10
-
-
0031861573
-
A technique for the quantitative evaluation of dose distributions
-
Low DA, Harms WB, Mutic S, Purdy JA. A technique for the quantitative evaluation of dose distributions. Med Phys. 1998;25(5):656-61.
-
(1998)
Med Phys
, vol.25
, Issue.5
, pp. 656-661
-
-
Low, D.A.1
Harms, W.B.2
Mutic, S.3
Purdy, J.A.4
-
11
-
-
84870943985
-
Pretreatment patient-specific IMRT quality assurance: a correlation study between gamma index and patient clinical dose volume histogram
-
Stasi M, Bresciani S, Miranti A, Maggio A, Sapino V, Gabriele P. Pretreatment patient-specific IMRT quality assurance: a correlation study between gamma index and patient clinical dose volume histogram. Med Phys. 2012;39(12):7626-34.
-
(2012)
Med Phys
, vol.39
, Issue.12
, pp. 7626-7634
-
-
Stasi, M.1
Bresciani, S.2
Miranti, A.3
Maggio, A.4
Sapino, V.5
Gabriele, P.6
-
12
-
-
84907284392
-
Comparison of 2D and 3D gamma analyses
-
Pulliam KB, Huang JY, Howell RM, et al. Comparison of 2D and 3D gamma analyses. Med Phys. 2014;41(2):021710.
-
(2014)
Med Phys
, vol.41
, Issue.2
-
-
Pulliam, K.B.1
Huang, J.Y.2
Howell, R.M.3
-
13
-
-
84890057550
-
Tomotherapy treatment plan quality assurance: The impact of applied criteria on passing rate in gamma index method
-
Bresciani S, Dia AD, Maggio A, et al. Tomotherapy treatment plan quality assurance: The impact of applied criteria on passing rate in gamma index method. Med Phys. 2013;40(12):121711.
-
(2013)
Med Phys
, vol.40
, Issue.12
-
-
Bresciani, S.1
Dia, A.D.2
Maggio, A.3
-
14
-
-
70350726816
-
IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119
-
Ezzell GA, Burmeister JW, Dogan N, et al. IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys. 2009;36(11):5359-73.
-
(2009)
Med Phys
, vol.36
, Issue.11
, pp. 5359-5373
-
-
Ezzell, G.A.1
Burmeister, J.W.2
Dogan, N.3
-
15
-
-
34548231706
-
A survey on planar IMRT QA analysis
-
Nelms BE and Simon JA. A survey on planar IMRT QA analysis. J Appl Clin Med Phys. 2007;8(3):76-90.
-
(2007)
J Appl Clin Med Phys
, vol.8
, Issue.3
, pp. 76-90
-
-
Nelms, B.E.1
Simon, J.A.2
-
16
-
-
10744231470
-
Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT subcommittee of the AAPM radiation therapy committee
-
Ezzell GA, Galvin JM, Low D, et al. Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT subcommittee of the AAPM radiation therapy committee. Med Phys. 2003;30(8):2089-115.
-
(2003)
Med Phys
, vol.30
, Issue.8
, pp. 2089-2115
-
-
Ezzell, G.A.1
Galvin, J.M.2
Low, D.3
-
17
-
-
52049100092
-
A literature review of electronic portal imaging for radiotherapy dosimetry
-
van Elmpt W, McDermott L, Nijsten S, Wendling M, Lambin P, Mijnheer B. A literature review of electronic portal imaging for radiotherapy dosimetry. Radiother Oncol. 2008;88(3):289-309.
-
(2008)
Radiother Oncol
, vol.88
, Issue.3
, pp. 289-309
-
-
van Elmpt, W.1
McDermott, L.2
Nijsten, S.3
Wendling, M.4
Lambin, P.5
Mijnheer, B.6
-
18
-
-
78650059288
-
Portal dosimetry for pretreatment verification of IMRT plan: a comparison with 2D ion chamber array
-
Sharma DS, Mhatre V, Heigrujam M, Talapatra K, Mallik S. Portal dosimetry for pretreatment verification of IMRT plan: a comparison with 2D ion chamber array. J Appl Clin Med Phys. 2010;11(4):238-48.
-
(2010)
J Appl Clin Med Phys
, vol.11
, Issue.4
, pp. 238-248
-
-
Sharma, D.S.1
Mhatre, V.2
Heigrujam, M.3
Talapatra, K.4
Mallik, S.5
-
19
-
-
1942478371
-
The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields
-
Van Esch A, Depuydt T, Huyskens DP. The use of an aSi-based EPID for routine absolute dosimetric pre-treatment verification of dynamic IMRT fields. Radiother Oncol. 2004;71(2):223-34.
-
(2004)
Radiother Oncol
, vol.71
, Issue.2
, pp. 223-234
-
-
Van Esch, A.1
Depuydt, T.2
Huyskens, D.P.3
-
20
-
-
79960509867
-
A quality assurance phantom for electronic portal imaging devices
-
Das IJ, Cao M, Cheng CW, et al. A quality assurance phantom for electronic portal imaging devices. J Appl Clin Med Phys. 2011;12(2):391-403.
-
(2011)
J Appl Clin Med Phys
, vol.12
, Issue.2
, pp. 391-403
-
-
Das, I.J.1
Cao, M.2
Cheng, C.W.3
-
22
-
-
84888410788
-
Optimized Varian aSi portal dosimetry: Development of datasets for collective use
-
Van Esch A, Huyskens DP, Hirschi L. Optimized Varian aSi portal dosimetry: Development of datasets for collective use. J Appl Clin Med Phys. 2013;14(6):82-99.
-
(2013)
J Appl Clin Med Phys
, vol.14
, Issue.6
, pp. 82-99
-
-
Van Esch, A.1
Huyskens, D.P.2
Hirschi, L.3
-
23
-
-
84893798541
-
To evaluate the accuracy of dynamic versus static IMRT delivery using portal dosimetry
-
Clemente S, Caivano R, Cozzolino M, et al. To evaluate the accuracy of dynamic versus static IMRT delivery using portal dosimetry. Clin Transl Oncol. 2014;16(2):208-12.
-
(2014)
Clin Transl Oncol
, vol.16
, Issue.2
, pp. 208-212
-
-
Clemente, S.1
Caivano, R.2
Cozzolino, M.3
-
26
-
-
84889647084
-
Evaluating IMRT and VMAT dose accuracy: Practical examples of failure to detect systematic errors when applying a commonly used metric and action levels
-
Nelms BE, Chan MF, Jarry G, et al. Evaluating IMRT and VMAT dose accuracy: Practical examples of failure to detect systematic errors when applying a commonly used metric and action levels. Med Phys. 2013;40(11):111722.
-
(2013)
Med Phys
, vol.40
, Issue.11
-
-
Nelms, B.E.1
Chan, M.F.2
Jarry, G.3
-
27
-
-
0003954913
-
-
fourth edition, Philadelphia: Lippincott Williams and Wilkins;
-
Khan FM. The Physics of Radiation Therapy, fourth edition. Philadelphia: Lippincott Williams and Wilkins; 2010.
-
(2010)
The Physics of Radiation Therapy
-
-
Khan, F.M.1
-
28
-
-
0003605672
-
-
fifth edition, Philadelphia: Lippincott Williams and Wilkins;
-
Hall EJ. Radiobiology for the Radiologist, fifth edition. Philadelphia: Lippincott Williams and Wilkins; 2000.
-
(2000)
Radiobiology for the Radiologist
-
-
Hall, E.J.1
-
29
-
-
22944477780
-
Long-term mortality from heart disease and lung cancer after radiotherapy for early breast cancer: Prospective cohort study of about 300,000 women in US SEER cancer registries
-
Darby SC, McGale P, Taylor CW, Peto R. Long-term mortality from heart disease and lung cancer after radiotherapy for early breast cancer: Prospective cohort study of about 300,000 women in US SEER cancer registries. Lancet Oncol. 2005;6(8):557-65.
-
(2005)
Lancet Oncol
, vol.6
, Issue.8
, pp. 557-565
-
-
Darby, S.C.1
McGale, P.2
Taylor, C.W.3
Peto, R.4
-
31
-
-
0036741110
-
Cancer induction by radiotherapy: dose dependence and spatial relationship to irradiated volume
-
Dörr W, Herrmann T. Cancer induction by radiotherapy: dose dependence and spatial relationship to irradiated volume. J Radiol Prot. 2002;22(3A):A117-21.
-
(2002)
J Radiol Prot
, vol.22
, Issue.3
, pp. A117-A121
-
-
Dörr, W.1
Herrmann, T.2
-
32
-
-
0036080949
-
Second primary tumors after radiotherapy for malignancies: Treatment-related parameters
-
Dörr W and Herrmann T. Second primary tumors after radiotherapy for malignancies: Treatment-related parameters. Strahlenther Onkol. 2002;178(7):357-62.
-
(2002)
Strahlenther Onkol
, vol.178
, Issue.7
, pp. 357-362
-
-
Dörr, W.1
Herrmann, T.2
-
33
-
-
79957532007
-
Assessing the risk of second malignancies after modern radiotherapy
-
Newhauser WD and Durante M. Assessing the risk of second malignancies after modern radiotherapy. Nat Rev Cancer. 2011;11(6):438-48.
-
(2011)
Nat Rev Cancer
, vol.11
, Issue.6
, pp. 438-448
-
-
Newhauser, W.D.1
Durante, M.2
-
34
-
-
67049172697
-
Frequency distribution of second solid cancer locations in relation to the irradiated volume among 115 patients treated for childhood cancer
-
Diallo I, Haddy N, Adjadj E, et al. Frequency distribution of second solid cancer locations in relation to the irradiated volume among 115 patients treated for childhood cancer. Int J Radiat Oncol Biol Phys. 2009;74(3):876-83.
-
(2009)
Int J Radiat Oncol Biol Phys
, vol.74
, Issue.3
, pp. 876-883
-
-
Diallo, I.1
Haddy, N.2
Adjadj, E.3
-
35
-
-
33645973559
-
Intensity-modulated radiation therapy, protons, and the risk of second cancers
-
Hall EJ. Intensity-modulated radiation therapy, protons, and the risk of second cancers. Int J Radiat Oncol Biol Phys. 2006;65(1):1-7.
-
(2006)
Int J Radiat Oncol Biol Phys
, vol.65
, Issue.1
, pp. 1-7
-
-
Hall, E.J.1
-
36
-
-
33645511871
-
Two-dimensional ionization chamber arrays for IMRT plan verification
-
Poppe B, Blechschmidt A, Djouguela A, et al. Two-dimensional ionization chamber arrays for IMRT plan verification. Med Phys. 2006;33(4):1005-15.
-
(2006)
Med Phys
, vol.33
, Issue.4
, pp. 1005-1015
-
-
Poppe, B.1
Blechschmidt, A.2
Djouguela, A.3
-
37
-
-
84904785092
-
The sensitivity of gamma-index method to the positioning errors of high-definition MLC in patient-specific VMAT QA for SBRT
-
Kim JI, Park SY, Kim HJ, et al. The sensitivity of gamma-index method to the positioning errors of high-definition MLC in patient-specific VMAT QA for SBRT. Radiat Oncol. 2014;9(167):1-12.
-
(2014)
Radiat Oncol
, vol.9
, Issue.167
, pp. 1-12
-
-
Kim, J.I.1
Park, S.Y.2
Kim, H.J.3
-
38
-
-
84874766976
-
On the sensitivity of common gamma-index evaluation methods to MLC misalignments in Rapidarc quality assurance
-
Heilemann G, Poppe B, Laub W. On the sensitivity of common gamma-index evaluation methods to MLC misalignments in Rapidarc quality assurance. Med Phys. 2013;40(3):031702.
-
(2013)
Med Phys
, vol.40
, Issue.3
-
-
Heilemann, G.1
Poppe, B.2
Laub, W.3
|