A quality assurance phantom for electronic portal imaging devices

Author keywords

EPID; Imager; MTF; QA

Indexed keywords


EID: 79960509867     PISSN: None     EISSN: 15269914     Source Type: Journal    
DOI: 10.1120/jacmp.v12i2.3350     Document Type: Article
Times cited : (17)

References (30)
  • 1
    • 0028839880 scopus 로고
    • Evaluation of digitally reconstructed radiographs (DRRs) used for clinical radiotherapy: a phantom study
    • McGee KP, Das IJ, Sims C. Evaluation of digitally reconstructed radiographs (DRRs) used for clinical radiotherapy: a phantom study. Med Phys. 1995;22(11 Pt. 1):1815-27.
    • (1995) Med Phys , vol.22 , Issue.11 PART 1 , pp. 1815-1827
    • McGee, K.P.1    Das, I.J.2    Sims, C.3
  • 2
    • 0345259674 scopus 로고
    • The digitally reconstructed radiograph
    • Coia LR, Schultheiss TE, Hanks GE, editors. Madison, WI: Advanced Medical Publishing
    • Das IJ, McGee KP, Desobrey GE. The digitally reconstructed radiograph. In: Coia LR, Schultheiss TE, Hanks GE, editors. A Practical Guide to CT Simulation. Madison, WI: Advanced Medical Publishing; 1995. p. 39-50.
    • (1995) A Practical Guide to CT Simulation , pp. 3950
    • Das, I.J.1    McGee, K.P.2    Desobrey, G.E.3
  • 3
    • 0023628868 scopus 로고
    • A coordinate transfer of anatomical information from CT to treatment simulation
    • Cheng CW, Chin LM, Kijewski PK. A coordinate transfer of anatomical information from CT to treatment simulation. Int J Radiat Oncol Biol Phys. 1987;13(10):1559-69.
    • (1987) Int J Radiat Oncol Biol Phys , vol.13 , Issue.10 , pp. 1559-1569
    • Cheng, C.W.1    Chin, L.M.2    Kijewski, P.K.3
  • 4
    • 0035018405 scopus 로고    scopus 로고
    • Clinical use of electronic portal imaging: report of AAPM Radiation Therapy Committee Task Group 58
    • Herman MG, Balter JM, Jaffray DA, et al. Clinical use of electronic portal imaging: report of AAPM Radiation Therapy Committee Task Group 58. Med Phys. 2001;28(5):712-37.
    • (2001) Med Phys , vol.28 , Issue.5 , pp. 712-737
    • Herman, M.G.1    Balter, J.M.2    Jaffray, D.A.3
  • 5
    • 0034810198 scopus 로고    scopus 로고
    • Portal imaging
    • Langmack KA. Portal imaging. Br J Radiol. 2001;74(885):789-804.
    • (2001) Br J Radiol , vol.74 , Issue.885 , pp. 789-804
    • Langmack, K.A.1
  • 6
    • 0037149519 scopus 로고    scopus 로고
    • Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research
    • Antonuk LE. Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research. Phys Med Biol. 2002;47(6):R31-R65.
    • (2002) Phys Med Biol , vol.47 , Issue.6
    • Antonuk, L.E.1
  • 7
    • 0030051211 scopus 로고    scopus 로고
    • Commissioning and periodic quality assurance of a clinical electronic portal imaging device
    • Low DA, Klein EE, Maag DK, Umfleet WE, Purdy JA. Commissioning and periodic quality assurance of a clinical electronic portal imaging device. Int J Radiat Oncol Biol Phys. 1996;34(1):117-23.
    • (1996) Int J Radiat Oncol Biol Phys , vol.34 , Issue.1 , pp. 117-123
    • Low, D.A.1    Klein, E.E.2    Maag, D.K.3    Umfleet, W.E.4    Purdy, J.A.5
  • 8
    • 4344686934 scopus 로고    scopus 로고
    • Registration of electronic portal images for patient set-up verification
    • Matsopoulos GK, Asvestas PA, Delibasis KK, et al. Registration of electronic portal images for patient set-up verification. Phys Med Biol. 2004;49(14):3279-89.
    • (2004) Phys Med Biol , vol.49 , Issue.14 , pp. 3279-3289
    • Matsopoulos, G.K.1    Asvestas, P.A.2    Delibasis, K.K.3
  • 9
    • 0036803213 scopus 로고    scopus 로고
    • Electronic and film portal images: a comparison of landmark visibility and review accuracy
    • Kruse JJ, Herman MG, Hagness CR, et al. Electronic and film portal images: a comparison of landmark visibility and review accuracy. Int J Radiat Oncol Biol Phys. 2002;54(2):584-91.
    • (2002) Int J Radiat Oncol Biol Phys , vol.54 , Issue.2 , pp. 584-591
    • Kruse, J.J.1    Herman, M.G.2    Hagness, C.R.3
  • 10
    • 0037111196 scopus 로고    scopus 로고
    • The use of electronic portal imaging to verify patient position during intensity-modulated radiotherapy delivered by the dynamic MLC technique
    • Fielding AL, Evans PM, Clark CH. The use of electronic portal imaging to verify patient position during intensity-modulated radiotherapy delivered by the dynamic MLC technique. Int J Radiat Oncol Biol Phys. 2002;54(4):1225-34.
    • (2002) Int J Radiat Oncol Biol Phys , vol.54 , Issue.4 , pp. 1225-1234
    • Fielding, A.L.1    Evans, P.M.2    Clark, C.H.3
  • 11
    • 0033965317 scopus 로고    scopus 로고
    • Verification of dynamic multileaf collimation using an electronic portal imaging device
    • James HV, Atherton S, Budgell GJ, Kirby MC, Williams PC. Verification of dynamic multileaf collimation using an electronic portal imaging device. Phys Med Biol. 2000;45(2):495-509.
    • (2000) Phys Med Biol , vol.45 , Issue.2 , pp. 495-509
    • James, H.V.1    Atherton, S.2    Budgell, G.J.3    Kirby, M.C.4    Williams, P.C.5
  • 12
    • 11244294832 scopus 로고    scopus 로고
    • On the use of EPID-based implanted marker tracking for 4D radiotherapy
    • Keall PJ, Todor AD, Vedam SS, et al. On the use of EPID-based implanted marker tracking for 4D radiotherapy. Med Phys. 2004;31(12):3492-99.
    • (2004) Med Phys , vol.31 , Issue.12 , pp. 3492-3499
    • Keall, P.J.1    Todor, A.D.2    Vedam, S.S.3
  • 13
    • 0347625746 scopus 로고    scopus 로고
    • Dosimetric IMRT verification with a flat-panel EPID
    • Warkentin B, Steciw S, Rathee S, Fallone B. Dosimetric IMRT verification with a flat-panel EPID. Med Phys. 2003;30(12):3143-55.
    • (2003) Med Phys , vol.30 , Issue.12 , pp. 3143-3155
    • Warkentin, B.1    Steciw, S.2    Rathee, S.3    Fallone, B.4
  • 14
    • 0032433905 scopus 로고    scopus 로고
    • In vivo dosimetry for prostate cancer patients using an electronic portal imaging device (EPID); demonstration of internal organ motion
    • Kroonwijk M, Pasma KL, Quint S, Koper PC, Visser AG, Heijmen BJ. In vivo dosimetry for prostate cancer patients using an electronic portal imaging device (EPID); demonstration of internal organ motion. Radiother Oncol. 1998;49(2):125-32.
    • (1998) Radiother Oncol , vol.49 , Issue.2 , pp. 125-132
    • Kroonwijk, M.1    Pasma, K.L.2    Quint, S.3    Koper, P.C.4    Visser, A.G.5    Heijmen, B.J.6
  • 15
    • 0038033842 scopus 로고    scopus 로고
    • Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy
    • Greer PB, Popescu CC. Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy. Med Phys. 2003;30(7):1618-27.
    • (2003) Med Phys , vol.30 , Issue.7 , pp. 1618-1627
    • Greer, P.B.1    Popescu, C.C.2
  • 16
    • 2442706565 scopus 로고    scopus 로고
    • Performance of electronic portal imaging devices (EPIDs) used in radiotherapy: image quality and dose measurements
    • Cremers F, Frenzel T, Kausch C, Albers D, Schönborn T, Schmidt R. Performance of electronic portal imaging devices (EPIDs) used in radiotherapy: image quality and dose measurements. Med Phys. 2004;31(5):985-96.
    • (2004) Med Phys , vol.31 , Issue.5 , pp. 985-996
    • Cremers, F.1    Frenzel, T.2    Kausch, C.3    Albers, D.4    Schönborn, T.5    Schmidt, R.6
  • 17
    • 0034957234 scopus 로고    scopus 로고
    • Pre-treatment dosimetric verification by means of a liquid-filled electronic portal imaging device during dynamic delivery of intensity modulated treatment fields
    • Van Esch A, Vanstraelen B, Verstraete J, Kutcher G, Huyskens D. Pre-treatment dosimetric verification by means of a liquid-filled electronic portal imaging device during dynamic delivery of intensity modulated treatment fields. Radiother Oncol. 2001;60(2):181-90.
    • (2001) Radiother Oncol , vol.60 , Issue.2 , pp. 181-190
    • Van Esch, A.1    Vanstraelen, B.2    Verstraete, J.3    Kutcher, G.4    Huyskens, D.5
  • 18
    • 68149155416 scopus 로고    scopus 로고
    • Monte Carlo-based adaptive EPID dose kernel accounting for different field size responses of imagers
    • Wang S, Gardner JK, Gordon JJ, et al. Monte Carlo-based adaptive EPID dose kernel accounting for different field size responses of imagers. Med Phys. 2009;36(8):3582-95.
    • (2009) Med Phys , vol.36 , Issue.8 , pp. 3582-3595
    • Wang, S.1    Gardner, J.K.2    Gordon, J.J.3
  • 19
    • 77954372264 scopus 로고    scopus 로고
    • Evaluation of a fast method of EPID-based dosimetry for intensity-modulated radiation therapy
    • Nelms BE, Rasmussen KH, Tome WA. Evaluation of a fast method of EPID-based dosimetry for intensity-modulated radiation therapy. J Appl Clin Med Phys. 2010;11(2):140-57.
    • (2010) J Appl Clin Med Phys , vol.11 , Issue.2 , pp. 140-157
    • Nelms, B.E.1    Rasmussen, K.H.2    Tome, W.A.3
  • 20
    • 0029900134 scopus 로고    scopus 로고
    • A quality control test for electronic portal imaging devices
    • Rajapakshe R, Luchka K, Shalev S. A quality control test for electronic portal imaging devices. Med Phys. 1996;23(7):1237-44.
    • (1996) Med Phys , vol.23 , Issue.7 , pp. 1237-1244
    • Rajapakshe, R.1    Luchka, K.2    Shalev, S.3
  • 21
    • 1542711413 scopus 로고    scopus 로고
    • Quality assurance measurements of a-Si EPID performance
    • Menon GV, Sloboda RS. Quality assurance measurements of a-Si EPID performance. Med Dosim. 2004;29(1):11-17.
    • (2004) Med Dosim , vol.29 , Issue.1 , pp. 11-17
    • Menon, G.V.1    Sloboda, R.S.2
  • 22
    • 0038710306 scopus 로고    scopus 로고
    • Compensator quality control with an amorphous silicon EPID
    • Menon GV, Sloboda RS. Compensator quality control with an amorphous silicon EPID. Med Phys. 2003;30(7):1816-24.
    • (2003) Med Phys , vol.30 , Issue.7 , pp. 1816-1824
    • Menon, G.V.1    Sloboda, R.S.2
  • 23
    • 79960502303 scopus 로고    scopus 로고
    • Evaluation of quality assurance phantom for electronic portal imaging device (EPID) [abstract]
    • Das I, Cheng C, Chopra K, Misic V, Schule E. Evaluation of quality assurance phantom for electronic portal imaging device (EPID) [abstract]. Med Phys. 2007;34(6):2371-72.
    • (2007) Med Phys , vol.34 , Issue.6 , pp. 2371-2372
    • Das, I.1    Cheng, C.2    Chopra, K.3    Misic, V.4    Schule, E.5
  • 24
    • 67650391486 scopus 로고    scopus 로고
    • Quality control of portal imaging with PTW EPID QC phantom
    • Pesznyák C, Fekete G, Mózes A, et al. Quality control of portal imaging with PTW EPID QC phantom. Strahlenther Onkol. 2009;185(1):56-60.
    • (2009) Strahlenther Onkol , vol.185 , Issue.1 , pp. 56-60
    • Pesznyák, C.1    Fekete, G.2    Mózes, A.3
  • 25
    • 34249737441 scopus 로고    scopus 로고
    • Amorphous silicon EPID calibration for dosimetric applications: comparison of a method based on Monte Carlo prediction of response with existing techniques
    • Parent L, Fielding AL, Dance DR, Seco J, Evans PM. Amorphous silicon EPID calibration for dosimetric applications: comparison of a method based on Monte Carlo prediction of response with existing techniques. Phys Med Biol. 2007;52(12):3351-68.
    • (2007) Phys Med Biol , vol.52 , Issue.12 , pp. 3351-3368
    • Parent, L.1    Fielding, A.L.2    Dance, D.R.3    Seco, J.4    Evans, P.M.5
  • 26
    • 0036338786 scopus 로고    scopus 로고
    • The electronic portal imaging system Siemens BeamView Plus versus the conventional verification films CEA-TVS and DuPont COL-7. A critical appraisal of visual image quality
    • Gagel B, Schramm O, Harms W, et al. The electronic portal imaging system Siemens BeamView Plus versus the conventional verification films CEA-TVS and DuPont COL-7. A critical appraisal of visual image quality. Strahlenther Onkol. 2002;178(8):446-52.
    • (2002) Strahlenther Onkol , vol.178 , Issue.8 , pp. 446-452
    • Gagel, B.1    Schramm, O.2    Harms, W.3
  • 27
    • 77953493215 scopus 로고    scopus 로고
    • A field size specific backscatter correction algorithm for accurate EPID dosimetry
    • Berry SL, Polvorosa CS, Wuu CS. A field size specific backscatter correction algorithm for accurate EPID dosimetry. Med Phys. 2010;37(6):2425-34.
    • (2010) Med Phys , vol.37 , Issue.6 , pp. 2425-2434
    • Berry, S.L.1    Polvorosa, C.S.2    Wuu, C.S.3
  • 29
    • 0000188292 scopus 로고
    • The specification of imaging properties by response to a sine wave input
    • Coleman JW. The specification of imaging properties by response to a sine wave input. Optics InfoBase. 1954;44:468-71.
    • (1954) Optics InfoBase , vol.44 , pp. 468-471
    • Coleman, J.W.1
  • 30
    • 26244436616 scopus 로고    scopus 로고
    • Determination of the modulation transfer function of digitally reconstructed radiographs in radiotherapy treatment planning using a point phantom
    • Kirwin SL, Langmack KA. Determination of the modulation transfer function of digitally reconstructed radiographs in radiotherapy treatment planning using a point phantom. Phys Med Biol. 2005;50(20):N251-N255.
    • (2005) Phys Med Biol , vol.50 , Issue.20
    • Kirwin, S.L.1    Langmack, K.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.