메뉴 건너뛰기




Volumn 34, Issue 6, 2015, Pages 835-840

Digitization of dental alginate impression: Three-dimensional evaluation of point cloud

Author keywords

Computer analysis; Impression scanning; Laser scanner; Point cloud; Stereolithography

Indexed keywords

LASER APPLICATIONS; RUBBER; SCANNING; STEREOLITHOGRAPHY;

EID: 84948961744     PISSN: 02874547     EISSN: 18811361     Source Type: Journal    
DOI: 10.4012/dmj.2014-313     Document Type: Article
Times cited : (13)

References (22)
  • 1
    • 58849151746 scopus 로고    scopus 로고
    • The relationship between digital model accuracy and time dependent deformation of alginate impressions
    • Alcan T, Ceylanoğlu C, Baysal B. The relationship between digital model accuracy and time dependent deformation of alginate impressions. Angle Orthod 2009; 79: 30-36.
    • (2009) Angle Orthod , vol.79 , pp. 30-36
    • Alcan, T.1    Ceylanoğlu, C.2    Baysal, B.3
  • 2
    • 9144236906 scopus 로고    scopus 로고
    • Physical properties and compatibility with dental stones of current alginate impression materials
    • Murata H, Kawamura M, Hamada T, Chimori H, Nikawa H. Physical properties and compatibility with dental stones of current alginate impression materials. J Oral Rehabil 2004; 31: 1115-1122.
    • (2004) J Oral Rehabil , vol.31 , pp. 1115-1122
    • Murata, H.1    Kawamura, M.2    Hamada, T.3    Chimori, H.4    Nikawa, H.5
  • 3
    • 76649130498 scopus 로고    scopus 로고
    • Accuracy and dimensional stability of extended-pour and conventional alginate impression materials
    • Imbery TA, Nehring J, Janus C, Moon PC. Accuracy and dimensional stability of extended-pour and conventional alginate impression materials. J Am Dent Assoc 2010; 141: 32-39.
    • (2010) J am Dent Assoc , vol.141 , pp. 32-39
    • Imbery, T.A.1    Nehring, J.2    Janus, C.3    Moon, P.C.4
  • 4
    • 0042389707 scopus 로고    scopus 로고
    • A clinical study comparing the three-dimensional accuracy of a working die generated from two dual-arch trays and a complete-arch custom tray
    • Ceyhan JA, Johnson GH, Lepe X, Phillips KM. A clinical study comparing the three-dimensional accuracy of a working die generated from two dual-arch trays and a complete-arch custom tray. J Prosthet Dent 2003; 90: 228-234.
    • (2003) J Prosthet Dent , vol.90 , pp. 228-234
    • Ceyhan, J.A.1    Johnson, G.H.2    Lepe, X.3    Phillips, K.M.4
  • 5
    • 0033143572 scopus 로고    scopus 로고
    • A 3D computer-aided design system applied to diagnosis and treatment planning in orthodontics and orthognathic surgery
    • Motohashi N, Kuroda T. A 3D computer-aided design system applied to diagnosis and treatment planning in orthodontics and orthognathic surgery. Eur J Orthod 1999; 21: 263-274.
    • (1999) Eur J Orthod , vol.21 , pp. 263-274
    • Motohashi, N.1    Kuroda, T.2
  • 7
    • 84897810281 scopus 로고    scopus 로고
    • Evaluation of different approaches for using a laser scanner in digitization of dental impressions
    • Wan-Son L, Woong-Chul K, Hea-Young K, Wook-Tae K, Ji-Hwan K. Evaluation of different approaches for using a laser scanner in digitization of dental impressions. J Adv Prosthodont 2014; 6: 22-29.
    • (2014) J Adv Prosthodont , vol.6 , pp. 22-29
    • Wan-Son, L.1    Woong-Chul, K.2    Hea-Young, K.3    Wook-Tae, K.4    Ji-Hwan, K.5
  • 8
    • 0031278678 scopus 로고    scopus 로고
    • A new optical 3-D device for the detection of wear
    • Mehl A, Gloger W, Kunzelmann KH, Hickel R. A new optical 3-D device for the detection of wear. J Dent Res 1997; 76: 1799-1807.
    • (1997) J Dent Res , vol.76 , pp. 1799-1807
    • Mehl, A.1    Gloger, W.2    Kunzelmann, K.H.3    Hickel, R.4
  • 9
    • 5144228654 scopus 로고    scopus 로고
    • The use of a 3D laser scanner using superimpositional software to assess theaccuracy of impression techniques
    • Shah S, Sundaram G, Bartlett D, Sherriff M. The use of a 3D laser scanner using superimpositional software to assess theaccuracy of impression techniques. J Dent 2004; 32: 653-658.
    • (2004) J Dent , vol.32 , pp. 653-658
    • Shah, S.1    Sundaram, G.2    Bartlett, D.3    Sherriff, M.4
  • 10
    • 0035409693 scopus 로고    scopus 로고
    • Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system
    • Tinschert J, Natt G, Mautsch W, Spiekermann H, Anusavice KJ. Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system. Oper Dent 2000; 26: 367-374.
    • (2000) Oper Dent , vol.26 , pp. 367-374
    • Tinschert, J.1    Natt, G.2    Mautsch, W.3    Spiekermann, H.4    Anusavice, K.J.5
  • 11
    • 0035377724 scopus 로고    scopus 로고
    • Factors influencing optical 3D scanning of vinyl polysiloxane impression materials
    • DeLong R, Pintado MR, Ko CC, Jodges JS, Douglas WH. Factors influencing optical 3D scanning of vinyl polysiloxane impression materials. J Prosthodont 2001; 10: 78-85.
    • (2001) J Prosthodont , vol.10 , pp. 78-85
    • Delong, R.1    Pintado, M.R.2    Ko, C.C.3    Jodges, J.S.4    Douglas, W.H.5
  • 12
    • 84865735500 scopus 로고    scopus 로고
    • Qualitative and quantitative three-dimensional accuracy of a single tooth captured by elastomeric impression materials: An in vitro study
    • Schaefer O, Schmidt M, Goebel R, Kuepper H. Qualitative and quantitative three-dimensional accuracy of a single tooth captured by elastomeric impression materials: an in vitro study. J Prosthet Dent 2012; 108: 165-172.
    • (2012) J Prosthet Dent , vol.108 , pp. 165-172
    • Schaefer, O.1    Schmidt, M.2    Goebel, R.3    Kuepper, H.4
  • 13
    • 36048966648 scopus 로고    scopus 로고
    • Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations
    • Quaas S, Rudolph H, Luthardt RG. Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations. J Dent 2007; 35: 903-908.
    • (2007) J Dent , vol.35 , pp. 903-908
    • Quaas, S.1    Rudolph, H.2    Luthardt, R.G.3
  • 14
    • 77049092054 scopus 로고    scopus 로고
    • Direct 3-D morphological measurements of silicone rubber impression using micro-focus X-ray CT
    • Kamegawa M, Nakamura M, Rukui Y, Tsutsumi S, Jojo M. Direct 3-D morphological measurements of silicone rubber impression using micro-focus X-ray CT. Dent Mater J 2010; 29: 68-74.
    • (2010) Dent Mater J , vol.29 , pp. 68-74
    • Kamegawa, M.1    Nakamura, M.2    Rukui, Y.3    Tsutsumi, S.4    Jojo, M.5
  • 15
    • 0037493678 scopus 로고    scopus 로고
    • Accuracy of a system for creating 3D computer models of dental arches
    • DeLong R, Heinzen M, Jodges JS, Ko CC, Douglas WH. Accuracy of a system for creating 3D computer models of dental arches. J Dent Res 2003; 82: 438-442.
    • (2003) J Dent Res , vol.82 , pp. 438-442
    • Delong, R.1    Heinzen, M.2    Jodges, J.S.3    Ko, C.C.4    Douglas, W.H.5
  • 16
    • 67349235615 scopus 로고    scopus 로고
    • Digitization of simulated clinical dental impressions: Virtual three-dimensional analysis of exactness
    • Persson AS, Oden A, Andersson M, Sandborgh-Enqlund G. Digitization of simulated clinical dental impressions: virtual three-dimensional analysis of exactness. Dent Mater 2009; 25: 929-936.
    • (2009) Dent Mater , vol.25 , pp. 929-936
    • Persson, A.S.1    Oden, A.2    Ersson, M.3    Sandborgh-Enqlund, G.4
  • 17
    • 84886412061 scopus 로고    scopus 로고
    • Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner
    • Flügge TV, Schlager S, Nelson K, Nahles S, Metzqer MC. Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofacial Orthop 2013; 144: 471-478.
    • (2013) Am J Orthod Dentofacial Orthop , vol.144 , pp. 471-478
    • Flügge, T.V.1    Schlager, S.2    Nelson, K.3    Nahles, S.4    Metzqer, M.C.5
  • 18
    • 84883739122 scopus 로고    scopus 로고
    • Comparative analysis on measuring performances of dental intraoral and extraoral optical 3D digitization systems
    • Trifkovic B, Budak I, Todorovic A, Vukelic D, Lazic V, Puskar T. Comparative analysis on measuring performances of dental intraoral and extraoral optical 3D digitization systems. Measurement 2014; 47: 45-53.
    • (2014) Measurement , vol.47 , pp. 45-53
    • Trifkovic, B.1    Budak, I.2    Todorovic, A.3    Vukelic, D.4    Lazic, V.5    Puskar, T.6
  • 20
    • 0037982937 scopus 로고    scopus 로고
    • Matching point clouds: Limits and possibilities
    • Rudolph H, Quaas S, Luthardt RG. Matching point clouds: limits and possibilities. Int J Comput Dent 2001; 5: 155-164.
    • (2001) Int J Comput Dent , vol.5 , pp. 155-164
    • Rudolph, H.1    Quaas, S.2    Luthardt, R.G.3
  • 21
    • 84949001258 scopus 로고    scopus 로고
    • No, A.S., for alginate impression material. Revised ANSI/ ADA Specification, 18-1992
    • No, A.S., for alginate impression material. Revised ANSI/ ADA Specification, 18-1992.
  • 22
    • 84949001259 scopus 로고
    • Association, A.D., Guide to Dental Materials and Devices ed 7. American Dental Association. Chicago
    • Association, A.D., Guide to Dental Materials and Devices ed 7. American Dental Association. Chicago 1975; p. 219-229.
    • (1975) , pp. 219-229


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.