메뉴 건너뛰기




Volumn 2, Issue , 2014, Pages 3294-3309.e1

Disinfection, Sterilization, and Control of Hospital Waste

Author keywords

Disinfection; Ethylene oxide; Glutaraldehyde; Hydrogen peroxide; Hypochlorite; Iodophor; Medical waste; Ortho phthalaldehyde; Peracetic acid; Sterilization

Indexed keywords


EID: 84944611409     PISSN: None     EISSN: None     Source Type: Book    
DOI: 10.1016/B978-1-4557-4801-3.00301-5     Document Type: Chapter
Times cited : (87)

References (358)
  • 2
    • 84863189507 scopus 로고    scopus 로고
    • Managing and preventing exposure events from inappropriately reprocessed endoscopes
    • Weber DJ Managing and preventing exposure events from inappropriately reprocessed endoscopes. Infect Control Hosp Epidemiol 2012, 33:657-660.
    • (2012) Infect Control Hosp Epidemiol , vol.33 , pp. 657-660
    • Weber, D.J.1
  • 3
    • 0028290954 scopus 로고
    • Audit of bronchoscope disinfection: a survey of procedures in England and Wales and incidents of mycobacterial contamination
    • Uttley AH, Simpson RA Audit of bronchoscope disinfection: a survey of procedures in England and Wales and incidents of mycobacterial contamination. J Hosp Infect 1994, 26:301-308.
    • (1994) J Hosp Infect , vol.26 , pp. 301-308
    • Uttley, A.H.1    Simpson, R.A.2
  • 4
    • 0027076628 scopus 로고
    • Transmission of infection by gastrointestinal endoscopy and bronchoscopy
    • Spach DH, Silverstein FE, Stamm WE Transmission of infection by gastrointestinal endoscopy and bronchoscopy. Ann Intern Med 1993, 118:117-128.
    • (1993) Ann Intern Med , vol.118 , pp. 117-128
    • Spach, D.H.1    Silverstein, F.E.2    Stamm, W.E.3
  • 5
    • 0034827267 scopus 로고    scopus 로고
    • Lessons from outbreaks associated with bronchoscopy
    • Weber DJ, Rutala WA Lessons from outbreaks associated with bronchoscopy. Infect Control Hosp Epidemiol 2001, 22:403-408.
    • (2001) Infect Control Hosp Epidemiol , vol.22 , pp. 403-408
    • Weber, D.J.1    Rutala, W.A.2
  • 6
    • 0242568023 scopus 로고    scopus 로고
    • The prevention of infection following gastrointestinal endoscopy: the importance of prophylaxis and reprocessing
    • Slack Inc, Thorofare, NJ, A.J. DiMarino, S.B. Benjamin (Eds.), 2nd ed.
    • Weber DJ, Rutala WA, DiMarino AJ The prevention of infection following gastrointestinal endoscopy: the importance of prophylaxis and reprocessing. Gastrointestinal Diseases: An Endoscopic Approach 2002, 87-106. Slack Inc, Thorofare, NJ. 2nd ed. A.J. DiMarino, S.B. Benjamin (Eds.).
    • (2002) Gastrointestinal Diseases: An Endoscopic Approach , pp. 87-106
    • Weber, D.J.1    Rutala, W.A.2    DiMarino, A.J.3
  • 7
    • 0036604095 scopus 로고    scopus 로고
    • An outbreak of Mycobacterium chelonae infection following liposuction
    • Meyers H, Brown-Elliott BA, Moore D, et al. An outbreak of Mycobacterium chelonae infection following liposuction. Clin Infect Dis 2002, 34:1500-1507.
    • (2002) Clin Infect Dis , vol.34 , pp. 1500-1507
    • Meyers, H.1    Brown-Elliott, B.A.2    Moore, D.3
  • 8
    • 0023759803 scopus 로고
    • Mycobacterium chelonae causing otitis media in an ear-nose-and-throat practice
    • Lowry PW, Jarvis WR, Oberle AD, et al. Mycobacterium chelonae causing otitis media in an ear-nose-and-throat practice. N Engl J Med 1988, 319:978-982.
    • (1988) N Engl J Med , vol.319 , pp. 978-982
    • Lowry, P.W.1    Jarvis, W.R.2    Oberle, A.D.3
  • 10
    • 84924381421 scopus 로고    scopus 로고
    • Selection and use of disinfectants in healthcare
    • Wolters Kluwer/Lippincott Williams & Wilkins, Philadelphia, C.G. Mayhall (Ed.), 4th ed.
    • Rutala WA, Weber DJ Selection and use of disinfectants in healthcare. Hospital Epidemiology and Infection Control 2012, Wolters Kluwer/Lippincott Williams & Wilkins, Philadelphia. 4th ed. C.G. Mayhall (Ed.).
    • (2012) Hospital Epidemiology and Infection Control
    • Rutala, W.A.1    Weber, D.J.2
  • 11
    • 84876943043 scopus 로고    scopus 로고
    • Disinfection, sterilization, and control of hospital waste
    • Churchill Livingstone Elsevier, Philadelphia, G.L. Mandell, J.E. Bennett, R. Dolin (Eds.), 7th ed.
    • Rutala WA, Weber DJ Disinfection, sterilization, and control of hospital waste. Principles and Practice of Infectious Diseases 2009, 3677-3695. Churchill Livingstone Elsevier, Philadelphia. 7th ed. G.L. Mandell, J.E. Bennett, R. Dolin (Eds.).
    • (2009) Principles and Practice of Infectious Diseases , pp. 3677-3695
    • Rutala, W.A.1    Weber, D.J.2
  • 13
    • 84973890054 scopus 로고    scopus 로고
    • Disinfection and sterilization in health-care facilities
    • Wolters Kluwer/Lippincott Williams & Wilkins, Philadelphia, W.R. Jarvis (Ed.), 6th ed.
    • Rutala WA, Weber DJ Disinfection and sterilization in health-care facilities. Bennett and Brachman's Hospital Infections 2013, Wolters Kluwer/Lippincott Williams & Wilkins, Philadelphia. 6th ed. W.R. Jarvis (Ed.).
    • (2013) Bennett and Brachman's Hospital Infections
    • Rutala, W.A.1    Weber, D.J.2
  • 14
    • 0002556667 scopus 로고    scopus 로고
    • Chemical disinfection of medical and surgical materials
    • Lippincott Williams & Wilkins, Philadelphia, S.S. Block (Ed.), 5th ed.
    • Favero MS, Bond WW Chemical disinfection of medical and surgical materials. Disinfection, Sterilization, and Preservation 2001, 881-917. Lippincott Williams & Wilkins, Philadelphia. 5th ed. S.S. Block (Ed.).
    • (2001) Disinfection, Sterilization, and Preservation , pp. 881-917
    • Favero, M.S.1    Bond, W.W.2
  • 15
    • 0002239984 scopus 로고
    • Chemical disinfection of medical and surgical materials
    • Lea & Febiger, Philadelphia, C. Lawrence, S.S. Block (Eds.)
    • Spaulding EH Chemical disinfection of medical and surgical materials. Disinfection, Sterilization, and Preservation 1968, 517-531. Lea & Febiger, Philadelphia. C. Lawrence, S.S. Block (Eds.).
    • (1968) Disinfection, Sterilization, and Preservation , pp. 517-531
    • Spaulding, E.H.1
  • 16
    • 0020573940 scopus 로고
    • CDC guidelines for the prevention and control of nosocomial infections: guideline for hospital environmental control
    • Simmons BP CDC guidelines for the prevention and control of nosocomial infections: guideline for hospital environmental control. Am J Infect Control 1983, 11:97-120.
    • (1983) Am J Infect Control , vol.11 , pp. 97-120
    • Simmons, B.P.1
  • 17
    • 0004230372 scopus 로고    scopus 로고
    • Lippincott Williams & Wilkins, Philadelphia, S.S. Block (Ed.), 5th ed.
    • Disinfection, Sterilization, and Preservation 2001, Lippincott Williams & Wilkins, Philadelphia. 5th ed. S.S. Block (Ed.).
    • (2001) Disinfection, Sterilization, and Preservation
  • 18
    • 0029738949 scopus 로고    scopus 로고
    • APIC guideline for selection and use of disinfectants. Association for Professionals in Infection Control and Epidemiology, Inc
    • 1994, 1995, and 1996 APIC Guidelines Committee
    • Rutala WA APIC guideline for selection and use of disinfectants. Association for Professionals in Infection Control and Epidemiology, Inc. Am J Infect Control 1996, 24:313-342. 1994, 1995, and 1996 APIC Guidelines Committee.
    • (1996) Am J Infect Control , vol.24 , pp. 313-342
    • Rutala, W.A.1
  • 19
    • 0001870548 scopus 로고    scopus 로고
    • Disinfection, sterilization and waste disposal
    • Williams and Wilkins, Baltimore, R.P. Wenzel (Ed.), 3rd ed.
    • Rutala WA Disinfection, sterilization and waste disposal. Prevention and Control of Nosocomial Infections 1997, 539-593. Williams and Wilkins, Baltimore. 3rd ed. R.P. Wenzel (Ed.).
    • (1997) Prevention and Control of Nosocomial Infections , pp. 539-593
    • Rutala, W.A.1
  • 20
    • 0022501175 scopus 로고
    • CDC guideline for handwashing and hospital environmental control, 1985
    • Garner JS, Favero MS CDC guideline for handwashing and hospital environmental control, 1985. Infect Control 1986, 7:231-243.
    • (1986) Infect Control , vol.7 , pp. 231-243
    • Garner, J.S.1    Favero, M.S.2
  • 21
    • 0025408763 scopus 로고
    • APIC guideline for selection and use of disinfectants
    • Rutala WA APIC guideline for selection and use of disinfectants. Am J Infect Control 1990, 18:99-117.
    • (1990) Am J Infect Control , vol.18 , pp. 99-117
    • Rutala, W.A.1
  • 22
    • 79958725386 scopus 로고    scopus 로고
    • Disinfection: is it time to reconsider Spaulding?
    • McDonnell G, Burke P Disinfection: is it time to reconsider Spaulding?. J Hosp Infect 2011, 78:163-170.
    • (2011) J Hosp Infect , vol.78 , pp. 163-170
    • McDonnell, G.1    Burke, P.2
  • 25
    • 0030074687 scopus 로고    scopus 로고
    • Comparison of ion plasma, vaporized hydrogen peroxide and 100% ethylene oxide sterilizers to the 12/88 ethylene oxide gas sterilizer
    • Alfa MJ, DeGagne P, Olson N, et al. Comparison of ion plasma, vaporized hydrogen peroxide and 100% ethylene oxide sterilizers to the 12/88 ethylene oxide gas sterilizer. Infect Control Hosp Epidemiol 1996, 17:92-100.
    • (1996) Infect Control Hosp Epidemiol , vol.17 , pp. 92-100
    • Alfa, M.J.1    DeGagne, P.2    Olson, N.3
  • 26
    • 84876912735 scopus 로고    scopus 로고
    • New developments in reprocessing semicritical devices
    • Rutala WA, Weber DJ New developments in reprocessing semicritical devices. Am J Infect Control 2013, 41(5 suppl):S60-S66.
    • (2013) Am J Infect Control , vol.41 , Issue.5 , pp. S60-S66
    • Rutala, W.A.1    Weber, D.J.2
  • 27
  • 28
    • 84856513367 scopus 로고    scopus 로고
    • Disinfection of an infrared coagulation device used to treat hemorrhoids
    • Rutala WA, Gergen MF, Weber DJ Disinfection of an infrared coagulation device used to treat hemorrhoids. Am J Infect Control 2012, 40:78-79.
    • (2012) Am J Infect Control , vol.40 , pp. 78-79
    • Rutala, W.A.1    Gergen, M.F.2    Weber, D.J.3
  • 29
    • 46449122727 scopus 로고    scopus 로고
    • Outbreak of cystoscopy related infections with Pseudomonas aeruginosa: New Mexico, 2007
    • Wendelboe AM, Baumbach J, Blossom DB, et al. Outbreak of cystoscopy related infections with Pseudomonas aeruginosa: New Mexico, 2007. J Urol 2008, 180:588-592.
    • (2008) J Urol , vol.180 , pp. 588-592
    • Wendelboe, A.M.1    Baumbach, J.2    Blossom, D.B.3
  • 30
    • 0035321323 scopus 로고    scopus 로고
    • Efficacy of high-level disinfectants for reprocessing gastrointestinal endoscopes in simulated-use testing
    • Foliente RL, Kovacs BJ, Aprecio RM, et al. Efficacy of high-level disinfectants for reprocessing gastrointestinal endoscopes in simulated-use testing. Gastrointest Endosc 2001, 53:456-462.
    • (2001) Gastrointest Endosc , vol.53 , pp. 456-462
    • Foliente, R.L.1    Kovacs, B.J.2    Aprecio, R.M.3
  • 31
    • 0032975663 scopus 로고    scopus 로고
    • High-level disinfection of gastrointestinal endoscopes: are current guidelines adequate?
    • Kovacs BJ, Chen YK, Kettering JD, et al. High-level disinfection of gastrointestinal endoscopes: are current guidelines adequate?. Am J Gastroenterol 1999, 94:1546-1550.
    • (1999) Am J Gastroenterol , vol.94 , pp. 1546-1550
    • Kovacs, B.J.1    Chen, Y.K.2    Kettering, J.D.3
  • 32
    • 17344367024 scopus 로고    scopus 로고
    • Nosocomial outbreaks/pseudo-outbreaks caused by nontuberculous mycobacteria
    • Wallace RJ, Brown BA, Griffith DE Nosocomial outbreaks/pseudo-outbreaks caused by nontuberculous mycobacteria. Annu Rev Microbiol 1998, 52:453-490.
    • (1998) Annu Rev Microbiol , vol.52 , pp. 453-490
    • Wallace, R.J.1    Brown, B.A.2    Griffith, D.E.3
  • 33
    • 0021818787 scopus 로고
    • Water-related nosocomial pneumonia caused by Legionella pneumophila serogroups 1 and 10
    • Meenhorst PL, Reingold AL, Groothuis DG, et al. Water-related nosocomial pneumonia caused by Legionella pneumophila serogroups 1 and 10. J Infect Dis 1985, 152:356-364.
    • (1985) J Infect Dis , vol.152 , pp. 356-364
    • Meenhorst, P.L.1    Reingold, A.L.2    Groothuis, D.G.3
  • 34
    • 0033171421 scopus 로고    scopus 로고
    • Legionella: from environmental habitats to disease pathology, detection and control
    • Atlas RM Legionella: from environmental habitats to disease pathology, detection and control. Environ Microbiol 1999, 1:283-293.
    • (1999) Environ Microbiol , vol.1 , pp. 283-293
    • Atlas, R.M.1
  • 36
    • 0002164744 scopus 로고    scopus 로고
    • Environmental issues and nosocomial infections
    • Williams & Wilkins, Baltimore, R.P. Wenzel (Ed.), 3rd ed.
    • Weber DJ, Rutala WA Environmental issues and nosocomial infections. Prevention and Control of Nosocomial Infections 1997, 491-514. Williams & Wilkins, Baltimore. 3rd ed. R.P. Wenzel (Ed.).
    • (1997) Prevention and Control of Nosocomial Infections , pp. 491-514
    • Weber, D.J.1    Rutala, W.A.2
  • 37
    • 79957963760 scopus 로고    scopus 로고
    • Multisociety guideline on reprocessing flexible GI endoscopes: 2011
    • Petersen BT, Chennat J, Cohen J, et al. Multisociety guideline on reprocessing flexible GI endoscopes: 2011. Infect Control Hosp Epidemiol 2011, 32:527-537.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 527-537
    • Petersen, B.T.1    Chennat, J.2    Cohen, J.3
  • 38
    • 0019974257 scopus 로고
    • Cleaning and disinfection of fiberoptic endoscopes: evaluation of glutaraldehyde exposure time and forced-air drying
    • Gerding DN, Peterson LR, Vennes JA Cleaning and disinfection of fiberoptic endoscopes: evaluation of glutaraldehyde exposure time and forced-air drying. Gastroenterology 1982, 83:613-618.
    • (1982) Gastroenterology , vol.83 , pp. 613-618
    • Gerding, D.N.1    Peterson, L.R.2    Vennes, J.A.3
  • 39
    • 0026161350 scopus 로고
    • Disinfection practices for endoscopes and other semicritical items
    • Rutala WA, Clontz EP, Weber DJ, et al. Disinfection practices for endoscopes and other semicritical items. Infect Control Hosp Epidemiol 1991, 12:282-288.
    • (1991) Infect Control Hosp Epidemiol , vol.12 , pp. 282-288
    • Rutala, W.A.1    Clontz, E.P.2    Weber, D.J.3
  • 40
    • 3042756428 scopus 로고    scopus 로고
    • Guidelines for environmental infection control in health-care facilities, 2003
    • Centers for Disease Control and Prevention Guidelines for environmental infection control in health-care facilities, 2003. MMWR Recomm Rep 2003, 52(RR-10):1-44.
    • (2003) MMWR Recomm Rep , vol.52 , Issue.RR 10 , pp. 1-44
  • 42
    • 0022621927 scopus 로고
    • Institutional outbreaks of rotavirus diarrhoea: potential role of fomites and environmental surfaces as vehicles for virus transmission
    • Sattar SA, Lloyd-Evans N, Springthorpe VS, et al. Institutional outbreaks of rotavirus diarrhoea: potential role of fomites and environmental surfaces as vehicles for virus transmission. J Hyg 1986, 96:277-289.
    • (1986) J Hyg , vol.96 , pp. 277-289
    • Sattar, S.A.1    Lloyd-Evans, N.2    Springthorpe, V.S.3
  • 43
    • 0031132010 scopus 로고    scopus 로고
    • Role of environmental contamination in the transmission of vancomycin-resistant enterococci
    • Weber DJ, Rutala WA Role of environmental contamination in the transmission of vancomycin-resistant enterococci. Infect Control Hosp Epidemiol 1997, 18:306-309.
    • (1997) Infect Control Hosp Epidemiol , vol.18 , pp. 306-309
    • Weber, D.J.1    Rutala, W.A.2
  • 44
    • 0025986922 scopus 로고
    • Prevention of surface-to-human transmission of rotaviruses by treatment with disinfectant spray
    • Ward RL, Bernstein DI, Knowlton DR, et al. Prevention of surface-to-human transmission of rotaviruses by treatment with disinfectant spray. J Clin Microbiol 1991, 29:1991-1996.
    • (1991) J Clin Microbiol , vol.29 , pp. 1991-1996
    • Ward, R.L.1    Bernstein, D.I.2    Knowlton, D.R.3
  • 45
    • 0027246416 scopus 로고
    • Chemical disinfection to interrupt transfer of rhinovirus type 14 from environmental surfaces to hands
    • Sattar SA, Jacobsen H, Springthorpe VS, et al. Chemical disinfection to interrupt transfer of rhinovirus type 14 from environmental surfaces to hands. Appl Environ Microbiol 1993, 59:1579-1585.
    • (1993) Appl Environ Microbiol , vol.59 , pp. 1579-1585
    • Sattar, S.A.1    Jacobsen, H.2    Springthorpe, V.S.3
  • 46
    • 0020384332 scopus 로고
    • Transmission of experimental rhinovirus infection by contaminated surfaces
    • Gwaltney JM, Hendley JO Transmission of experimental rhinovirus infection by contaminated surfaces. Am J Epidemiol 1982, 116:828-833.
    • (1982) Am J Epidemiol , vol.116 , pp. 828-833
    • Gwaltney, J.M.1    Hendley, J.O.2
  • 47
    • 0028693196 scopus 로고
    • Interruption of rotavirus spread through chemical disinfection
    • Sattar SA, Jacobsen H, Rahman H, et al. Interruption of rotavirus spread through chemical disinfection. Infect Control Hosp Epidemiol 1994, 15:751-756.
    • (1994) Infect Control Hosp Epidemiol , vol.15 , pp. 751-756
    • Sattar, S.A.1    Jacobsen, H.2    Rahman, H.3
  • 48
    • 0033630769 scopus 로고    scopus 로고
    • Antimicrobial activity of home disinfectants and natural products against potential human pathogens
    • Rutala WA, Barbee SL, Aguiar NC, et al. Antimicrobial activity of home disinfectants and natural products against potential human pathogens. Infect Control Hosp Epidemiol 2000, 21:33-38.
    • (2000) Infect Control Hosp Epidemiol , vol.21 , pp. 33-38
    • Rutala, W.A.1    Barbee, S.L.2    Aguiar, N.C.3
  • 49
    • 0025182439 scopus 로고
    • Efficacies of selected disinfectants against Mycobacterium tuberculosis
    • Best M, Sattar SA, Springthorpe VS, et al. Efficacies of selected disinfectants against Mycobacterium tuberculosis. J Clin Microbiol 1990, 28:2234-2239.
    • (1990) J Clin Microbiol , vol.28 , pp. 2234-2239
    • Best, M.1    Sattar, S.A.2    Springthorpe, V.S.3
  • 50
    • 0025093588 scopus 로고
    • Efficacy of a variety of disinfectants against Listeria spp
    • Best M, Kennedy ME, Coates F Efficacy of a variety of disinfectants against Listeria spp. Appl Environ Microbiol 1990, 56:377-380.
    • (1990) Appl Environ Microbiol , vol.56 , pp. 377-380
    • Best, M.1    Kennedy, M.E.2    Coates, F.3
  • 51
    • 0028237289 scopus 로고
    • Feasibility of a combined carrier test for disinfectants: studies with a mixture of five types of microorganisms
    • Best M, Springthorpe VS, Sattar SA Feasibility of a combined carrier test for disinfectants: studies with a mixture of five types of microorganisms. Am J Infect Control 1994, 22:152-162.
    • (1994) Am J Infect Control , vol.22 , pp. 152-162
    • Best, M.1    Springthorpe, V.S.2    Sattar, S.A.3
  • 52
    • 0023031029 scopus 로고
    • Chemical disinfection of human rotaviruses: efficacy of commercially-available products in suspension tests
    • Springthorpe VS, Grenier JL, Lloyd-Evans N, et al. Chemical disinfection of human rotaviruses: efficacy of commercially-available products in suspension tests. J Hyg 1986, 97:139-161.
    • (1986) J Hyg , vol.97 , pp. 139-161
    • Springthorpe, V.S.1    Grenier, J.L.2    Lloyd-Evans, N.3
  • 53
    • 0025764373 scopus 로고
    • Survival and disinfectant inactivation of the human immunodeficiency virus: a critical review
    • Sattar SA, Springthorpe VS Survival and disinfectant inactivation of the human immunodeficiency virus: a critical review. Rev Infect Dis 1991, 13:430-447.
    • (1991) Rev Infect Dis , vol.13 , pp. 430-447
    • Sattar, S.A.1    Springthorpe, V.S.2
  • 54
    • 0033254252 scopus 로고    scopus 로고
    • The effect of blood on the antiviral activity of sodium hypochlorite, a phenolic, and a quaternary ammonium compound
    • Weber DJ, Barbee SL, Sobsey MD, et al. The effect of blood on the antiviral activity of sodium hypochlorite, a phenolic, and a quaternary ammonium compound. Infect Control Hosp Epidemiol 1999, 20:821-827.
    • (1999) Infect Control Hosp Epidemiol , vol.20 , pp. 821-827
    • Weber, D.J.1    Barbee, S.L.2    Sobsey, M.D.3
  • 55
    • 77952572492 scopus 로고    scopus 로고
    • How stable is the hepatitis C virus (HCV)? Environmental stability of HCV and its susceptibility to chemical biocides
    • Ciesek S, Friesland M, Steinmann J, et al. How stable is the hepatitis C virus (HCV)? Environmental stability of HCV and its susceptibility to chemical biocides. J Infect Dis 2010, 201:1859-1866.
    • (2010) J Infect Dis , vol.201 , pp. 1859-1866
    • Ciesek, S.1    Friesland, M.2    Steinmann, J.3
  • 56
    • 70349247697 scopus 로고    scopus 로고
    • The antiviral action of common household disinfectants and antiseptics against murine hepatitis virus, a potential surrogate for SARS coronavirus
    • Dellanno C, Vega Q, Boesenberg D The antiviral action of common household disinfectants and antiseptics against murine hepatitis virus, a potential surrogate for SARS coronavirus. Am J Infect Control 2009, 37:649-652.
    • (2009) Am J Infect Control , vol.37 , pp. 649-652
    • Dellanno, C.1    Vega, Q.2    Boesenberg, D.3
  • 57
    • 77953026367 scopus 로고    scopus 로고
    • Inactivation of influenza A virus H1N1 by disinfection process
    • Jeong EK, Bae JE, Kim IS Inactivation of influenza A virus H1N1 by disinfection process. Am J Infect Control 2010, 38:354-360.
    • (2010) Am J Infect Control , vol.38 , pp. 354-360
    • Jeong, E.K.1    Bae, J.E.2    Kim, I.S.3
  • 58
    • 84867438406 scopus 로고    scopus 로고
    • Efficacy of improved hydrogen peroxide against important healthcare-associated pathogens
    • Rutala WA, Gergen MF, Weber DJ Efficacy of improved hydrogen peroxide against important healthcare-associated pathogens. Infect Control Hosp Epidemiol 2012, 33:1159-1161.
    • (2012) Infect Control Hosp Epidemiol , vol.33 , pp. 1159-1161
    • Rutala, W.A.1    Gergen, M.F.2    Weber, D.J.3
  • 59
    • 77955035549 scopus 로고    scopus 로고
    • Are disinfectants accurately prepared for use in hospital patient care areas?
    • Pentella MA, Fisher T, Chandler S, et al. Are disinfectants accurately prepared for use in hospital patient care areas?. Infect Control Hosp Epidemiol 2000, 21:103.
    • (2000) Infect Control Hosp Epidemiol , vol.21 , pp. 103
    • Pentella, M.A.1    Fisher, T.2    Chandler, S.3
  • 60
    • 33646679119 scopus 로고    scopus 로고
    • Bacterial contamination of keyboards: efficacy and functional impact of disinfectants
    • Rutala WA, White MS, Gergen MF, et al. Bacterial contamination of keyboards: efficacy and functional impact of disinfectants. Infect Control Hosp Epidemiol 2006, 27:372-377.
    • (2006) Infect Control Hosp Epidemiol , vol.27 , pp. 372-377
    • Rutala, W.A.1    White, M.S.2    Gergen, M.F.3
  • 61
    • 35548976241 scopus 로고    scopus 로고
    • Microbiologic evaluation of microfiber mops for surface disinfection
    • Rutala WA, Gergen MF, Weber DJ Microbiologic evaluation of microfiber mops for surface disinfection. Am J Infect Control 2007, 35:569-573.
    • (2007) Am J Infect Control , vol.35 , pp. 569-573
    • Rutala, W.A.1    Gergen, M.F.2    Weber, D.J.3
  • 62
    • 0015045041 scopus 로고
    • Hospital sanitation: the massive bacterial contamination of the wet mop
    • Westwood JC, Mitchell MA, Legace S Hospital sanitation: the massive bacterial contamination of the wet mop. Appl Microbiol 1971, 21:693-697.
    • (1971) Appl Microbiol , vol.21 , pp. 693-697
    • Westwood, J.C.1    Mitchell, M.A.2    Legace, S.3
  • 63
    • 34250165041 scopus 로고    scopus 로고
    • Monitoring the effectiveness of cleaning in four British hospitals
    • Cooper RA, Griffith CJ, Malik RE, et al. Monitoring the effectiveness of cleaning in four British hospitals. Am J Infect Control 2007, 35:338-341.
    • (2007) Am J Infect Control , vol.35 , pp. 338-341
    • Cooper, R.A.1    Griffith, C.J.2    Malik, R.E.3
  • 64
    • 67651098977 scopus 로고    scopus 로고
    • Monitoring the effectiveness of hospital cleaning practices by use of an adenosine triphosphate bioluminescence assay
    • Boyce JM, Havill NL, Dumigan DG, et al. Monitoring the effectiveness of hospital cleaning practices by use of an adenosine triphosphate bioluminescence assay. Infect Control Hosp Epidemiol 2009, 30:678-684.
    • (2009) Infect Control Hosp Epidemiol , vol.30 , pp. 678-684
    • Boyce, J.M.1    Havill, N.L.2    Dumigan, D.G.3
  • 65
    • 44149087791 scopus 로고    scopus 로고
    • A modified ATP benchmark for evaluating the cleaning of some hospital environmental surfaces
    • Lewis T, Griffith C, Gallo M, et al. A modified ATP benchmark for evaluating the cleaning of some hospital environmental surfaces. J Hosp Infect 2008, 69:156-163.
    • (2008) J Hosp Infect , vol.69 , pp. 156-163
    • Lewis, T.1    Griffith, C.2    Gallo, M.3
  • 66
    • 54949127200 scopus 로고    scopus 로고
    • Improving cleaning of the environment surrounding patients in 36 acute care hospitals
    • Carling PC, Parry MF, Rupp ME, et al. Improving cleaning of the environment surrounding patients in 36 acute care hospitals. Infect Control Hosp Epidemiol 2008, 29:1035-1041.
    • (2008) Infect Control Hosp Epidemiol , vol.29 , pp. 1035-1041
    • Carling, P.C.1    Parry, M.F.2    Rupp, M.E.3
  • 67
    • 65349091877 scopus 로고    scopus 로고
    • Use of a fluorescent chemical as a quality indicator for a hospital cleaning program
    • Blue J, O'Neill C, Speziale P, et al. Use of a fluorescent chemical as a quality indicator for a hospital cleaning program. Can J Infect Control 2008, 23:216-219.
    • (2008) Can J Infect Control , vol.23 , pp. 216-219
    • Blue, J.1    O'Neill, C.2    Speziale, P.3
  • 68
    • 84944611481 scopus 로고    scopus 로고
    • Public Health Notification from FDA, CDC, EPA and OSHA
    • U.S. Department of Health & Human Services, October 31
    • U.S. Food and Drug Administration. Public Health Notification from FDA, CDC, EPA and OSHA: Avoiding Hazards with Using Cleaners and Disinfectants on Electronic Medical Equipment. U.S. Department of Health & Human Services, October 31, 2007.
    • (2007) Avoiding Hazards with Using Cleaners and Disinfectants on Electronic Medical Equipment.
  • 69
    • 0003591674 scopus 로고    scopus 로고
    • Occupational risks associated with the use of selected disinfectants and sterilants
    • Polyscience Publications, Champlain, NY, W.A. Rutala (Ed.)
    • Weber DJ, Rutala WA Occupational risks associated with the use of selected disinfectants and sterilants. Disinfection, Sterilization, and Antisepsis in Healthcare 1998, 211-226. Polyscience Publications, Champlain, NY. W.A. Rutala (Ed.).
    • (1998) Disinfection, Sterilization, and Antisepsis in Healthcare , pp. 211-226
    • Weber, D.J.1    Rutala, W.A.2
  • 70
    • 0011043541 scopus 로고
    • Alcohol as a surgical disinfectant
    • Spaulding EH Alcohol as a surgical disinfectant. AORN J 1964, 2:67-71.
    • (1964) AORN J , vol.2 , pp. 67-71
    • Spaulding, E.H.1
  • 71
    • 0010830635 scopus 로고
    • The relationship of concentration and germicidal efficiency of ethyl alcohol
    • Morton HE The relationship of concentration and germicidal efficiency of ethyl alcohol. Ann NY Acad Sci 1950, 53:191-196.
    • (1950) Ann NY Acad Sci , vol.53 , pp. 191-196
    • Morton, H.E.1
  • 73
    • 33646303029 scopus 로고
    • A note on the fallacy of using alcohol for the sterilization of surgical instruments
    • Nye RN, Mallory TB A note on the fallacy of using alcohol for the sterilization of surgical instruments. Boston Med Surg J 1923, 189:561-563.
    • (1923) Boston Med Surg J , vol.189 , pp. 561-563
    • Nye, R.N.1    Mallory, T.B.2
  • 74
    • 33645798070 scopus 로고    scopus 로고
    • Efficacy of hospital germicides against adenovirus 8, a common cause of epidemic keratoconjunctivitis in health care facilities
    • Rutala WA, Peacock JE, Gergen MF, et al. Efficacy of hospital germicides against adenovirus 8, a common cause of epidemic keratoconjunctivitis in health care facilities. Antimicrob Agents Chemother 2006, 50:1419-1424.
    • (2006) Antimicrob Agents Chemother , vol.50 , pp. 1419-1424
    • Rutala, W.A.1    Peacock, J.E.2    Gergen, M.F.3
  • 75
    • 4444276316 scopus 로고    scopus 로고
    • Selection and use of disinfectants in healthcare
    • Lippincott Williams & Wilkins, Philadelphia, C.G. Mayhall (Ed.), 3rd ed.
    • Rutala WA, Weber DJ Selection and use of disinfectants in healthcare. Hospital Epidemiology and Infection Control 2004, 1473-1522. Lippincott Williams & Wilkins, Philadelphia. 3rd ed. C.G. Mayhall (Ed.).
    • (2004) Hospital Epidemiology and Infection Control , pp. 1473-1522
    • Rutala, W.A.1    Weber, D.J.2
  • 76
    • 0030723030 scopus 로고    scopus 로고
    • Uses of inorganic hypochlorite (bleach) in health-care facilities
    • Rutala WA, Weber DJ Uses of inorganic hypochlorite (bleach) in health-care facilities. Clin Microbiol Rev 1997, 10:597-610.
    • (1997) Clin Microbiol Rev , vol.10 , pp. 597-610
    • Rutala, W.A.1    Weber, D.J.2
  • 77
    • 0034105446 scopus 로고    scopus 로고
    • Safety and cleaning of medical materials and devices
    • Merritt K, Hitchins VM, Brown SA Safety and cleaning of medical materials and devices. J Biomed Mater Res 2000, 53:131-136.
    • (2000) J Biomed Mater Res , vol.53 , pp. 131-136
    • Merritt, K.1    Hitchins, V.M.2    Brown, S.A.3
  • 78
    • 0026355098 scopus 로고
    • Poisoning with sodium hypochlorite solution: report of a fatal case, supplemented with an experimental and clinico-epidemiological study
    • Jakobsson SW, Rajs J, Jonsson JA, et al. Poisoning with sodium hypochlorite solution: report of a fatal case, supplemented with an experimental and clinico-epidemiological study. Am J Forens Med Pathol 1991, 12:320-327.
    • (1991) Am J Forens Med Pathol , vol.12 , pp. 320-327
    • Jakobsson, S.W.1    Rajs, J.2    Jonsson, J.A.3
  • 79
    • 0025892376 scopus 로고
    • Treatment of acute hypoxemic respiratory failure caused by chlorine exposure
    • Heidemann SM, Goetting MG Treatment of acute hypoxemic respiratory failure caused by chlorine exposure. Pediatr Emerg Care 1991, 7:87-88.
    • (1991) Pediatr Emerg Care , vol.7 , pp. 87-88
    • Heidemann, S.M.1    Goetting, M.G.2
  • 80
    • 0014860041 scopus 로고
    • Esophageal stenosis produced by ingestion of bleach: report of two cases
    • French RJ, Tabb HG, Rutledge LJ Esophageal stenosis produced by ingestion of bleach: report of two cases. South Med J 1970, 63:1140-1144.
    • (1970) South Med J , vol.63 , pp. 1140-1144
    • French, R.J.1    Tabb, H.G.2    Rutledge, L.J.3
  • 81
    • 0025432568 scopus 로고
    • Response of the human eye to accidental exposure to sodium hypochlorite
    • Ingram TA Response of the human eye to accidental exposure to sodium hypochlorite. J Endod 1990, 16:235-238.
    • (1990) J Endod , vol.16 , pp. 235-238
    • Ingram, T.A.1
  • 82
    • 0027181058 scopus 로고
    • Home exposures to chlorine/chloramine gas: review of 216 cases
    • Mrvos R, Dean BS, Krenzelok EP Home exposures to chlorine/chloramine gas: review of 216 cases. South Med J 1993, 86:654-657.
    • (1993) South Med J , vol.86 , pp. 654-657
    • Mrvos, R.1    Dean, B.S.2    Krenzelok, E.P.3
  • 84
    • 0348220729 scopus 로고    scopus 로고
    • Not all super-oxidized waters are the same
    • Sampson MN, Muir AVG Not all super-oxidized waters are the same. J Hosp Infect 2002, 52:227-228.
    • (2002) J Hosp Infect , vol.52 , pp. 227-228
    • Sampson, M.N.1    Muir, A.V.G.2
  • 85
    • 0032896277 scopus 로고    scopus 로고
    • Evaluation of the antimicrobial activity of a new super-oxidized water, Sterilox®, for the disinfection of endoscopes
    • Selkon JB, Babb JR, Morris R Evaluation of the antimicrobial activity of a new super-oxidized water, Sterilox®, for the disinfection of endoscopes. J Hosp Infect 1999, 41:59-70.
    • (1999) J Hosp Infect , vol.41 , pp. 59-70
    • Selkon, J.B.1    Babb, J.R.2    Morris, R.3
  • 86
    • 0032966329 scopus 로고    scopus 로고
    • Evaluation of microbicidal activity of a new disinfectant: Sterilox® 2500 against Clostridium difficile spores, Helicobacter pylori, vancomycin resistant Enterococcus species, Candida albicans and several Mycobacterium species
    • Shetty N, Srinivasan S, Holton J, et al. Evaluation of microbicidal activity of a new disinfectant: Sterilox® 2500 against Clostridium difficile spores, Helicobacter pylori, vancomycin resistant Enterococcus species, Candida albicans and several Mycobacterium species. J Hosp Infect 1999, 41:101-105.
    • (1999) J Hosp Infect , vol.41 , pp. 101-105
    • Shetty, N.1    Srinivasan, S.2    Holton, J.3
  • 88
    • 0020475764 scopus 로고
    • Acquired immune deficiency syndrome (AIDS): precautions for clinical and laboratory staffs
    • Centers for Disease Control Acquired immune deficiency syndrome (AIDS): precautions for clinical and laboratory staffs. MMWR Morb Mortal Wkly Rep 1982, 31:577-580.
    • (1982) MMWR Morb Mortal Wkly Rep , vol.31 , pp. 577-580
  • 89
    • 0023661798 scopus 로고
    • Recommendations for prevention of HIV transmission in health-care settings
    • Centers for Disease Control Recommendations for prevention of HIV transmission in health-care settings. MMWR Morb Mortal Wkly Rep 1987, 36:S3-S18.
    • (1987) MMWR Morb Mortal Wkly Rep , vol.36 , pp. S3-S18
  • 90
    • 0024977004 scopus 로고
    • Guidelines for prevention of transmission of human immunodeficiency virus and hepatitis B virus to health-care and public-safety workers
    • Centers for Disease Control Guidelines for prevention of transmission of human immunodeficiency virus and hepatitis B virus to health-care and public-safety workers. MMWR Morb Mortal Wkly Rep 1989, 38(S-6):1-37.
    • (1989) MMWR Morb Mortal Wkly Rep , vol.38 , Issue.S 6 , pp. 1-37
  • 91
    • 0020787946 scopus 로고
    • Guideline for isolation precautions in hospitals
    • Garner JS, Simmons BP Guideline for isolation precautions in hospitals. Infect Control 1983, 4(4 suppl):245-325.
    • (1983) Infect Control , vol.4 , Issue.4 , pp. 245-325
    • Garner, J.S.1    Simmons, B.P.2
  • 92
    • 0024400980 scopus 로고
    • A comparison of hypochlorite and phenolic disinfectants for disinfection of clean and soiled surfaces and blood spillages
    • Bloomfield SF, Miller EA A comparison of hypochlorite and phenolic disinfectants for disinfection of clean and soiled surfaces and blood spillages. J Hosp Infect 1989, 13:231-239.
    • (1989) J Hosp Infect , vol.13 , pp. 231-239
    • Bloomfield, S.F.1    Miller, E.A.2
  • 93
    • 0032607540 scopus 로고    scopus 로고
    • Disinfection of endoscopes: review of new chemical sterilants used for high-level disinfection
    • Rutala WA, Weber DJ Disinfection of endoscopes: review of new chemical sterilants used for high-level disinfection. Infect Control Hosp Epidemiol 1999, 20:69-76.
    • (1999) Infect Control Hosp Epidemiol , vol.20 , pp. 69-76
    • Rutala, W.A.1    Weber, D.J.2
  • 94
    • 39749111479 scopus 로고    scopus 로고
    • Measures to control and prevent Clostridium difficile infection
    • Gerding DN, Muto CA, Owens RC Measures to control and prevent Clostridium difficile infection. Clin Infect Dis 2008, 46(suppl 1):S43-S49.
    • (2008) Clin Infect Dis , vol.46 , pp. S43-S49
    • Gerding, D.N.1    Muto, C.A.2    Owens, R.C.3
  • 95
    • 23044492188 scopus 로고    scopus 로고
    • Activity of selected oxidizing microbicides against spores of Clostridium difficile: relevance to environmental control
    • Perez J, Springthorpe S, Sattar SA Activity of selected oxidizing microbicides against spores of Clostridium difficile: relevance to environmental control. Am J Infect Control 2005, 33:320-325.
    • (2005) Am J Infect Control , vol.33 , pp. 320-325
    • Perez, J.1    Springthorpe, S.2    Sattar, S.A.3
  • 97
    • 77952960299 scopus 로고    scopus 로고
    • Significant impact of terminal room cleaning with bleach on reducing nosocomial Clostridium difficile
    • Hacek DM, Ogle AM, Fisher A, et al. Significant impact of terminal room cleaning with bleach on reducing nosocomial Clostridium difficile. Am J Infect Control 2010, 38:350-353.
    • (2010) Am J Infect Control , vol.38 , pp. 350-353
    • Hacek, D.M.1    Ogle, A.M.2    Fisher, A.3
  • 98
    • 0034452451 scopus 로고    scopus 로고
    • Environmental control to reduce transmission of Clostridium difficile
    • Mayfield JL, Leet T, Miller J, et al. Environmental control to reduce transmission of Clostridium difficile. Clin Infect Dis 2000, 31:995-1000.
    • (2000) Clin Infect Dis , vol.31 , pp. 995-1000
    • Mayfield, J.L.1    Leet, T.2    Miller, J.3
  • 99
    • 0020573788 scopus 로고
    • Legionnaires' disease associated with a hospital water system: a cluster of 24 nosocomial cases
    • Helms CM, Massanari RM, Zeitler R, et al. Legionnaires' disease associated with a hospital water system: a cluster of 24 nosocomial cases. Ann Intern Med 1983, 99:172-178.
    • (1983) Ann Intern Med , vol.99 , pp. 172-178
    • Helms, C.M.1    Massanari, R.M.2    Zeitler, R.3
  • 100
    • 0023943794 scopus 로고
    • Legionnaires' disease associated with a hospital water system. A five-year progress report on continuous hyperchlorination
    • Helms C, Massanari R, Wenzel R, et al. Legionnaires' disease associated with a hospital water system. A five-year progress report on continuous hyperchlorination. JAMA 1988, 259:2423-2427.
    • (1988) JAMA , vol.259 , pp. 2423-2427
    • Helms, C.1    Massanari, R.2    Wenzel, R.3
  • 101
    • 0032842841 scopus 로고    scopus 로고
    • GI endoscopic reprocessing practices in the United States
    • Cheung RJ, Ortiz D, DiMarino AJ GI endoscopic reprocessing practices in the United States. Gastrointest Endosc 1999, 50:362-368.
    • (1999) Gastrointest Endosc , vol.50 , pp. 362-368
    • Cheung, R.J.1    Ortiz, D.2    DiMarino, A.J.3
  • 102
    • 0017597215 scopus 로고
    • Antimicrobial and other properties of a new stabilized alkaline glutaraldehyde disinfectant/sterilizer
    • Miner NA, McDowell JW, Willcockson GW, et al. Antimicrobial and other properties of a new stabilized alkaline glutaraldehyde disinfectant/sterilizer. Am J Hosp Pharm 1977, 34:376-382.
    • (1977) Am J Hosp Pharm , vol.34 , pp. 376-382
    • Miner, N.A.1    McDowell, J.W.2    Willcockson, G.W.3
  • 103
    • 0018994573 scopus 로고
    • Comparison of the activities and stabilities of alkaline glutaraldehyde sterilizing solutions
    • Pepper RE Comparison of the activities and stabilities of alkaline glutaraldehyde sterilizing solutions. Infect Control 1980, 1:90-92.
    • (1980) Infect Control , vol.1 , pp. 90-92
    • Pepper, R.E.1
  • 104
    • 33044503205 scopus 로고    scopus 로고
    • Glutaraldehyde
    • Lippincott Williams & Wilkins, Philadelphia, S.S. Block (Ed.), 5th ed.
    • Scott EM, Gorman SP Glutaraldehyde. Disinfection, Sterilization, and Preservation 2001, 361-381. Lippincott Williams & Wilkins, Philadelphia. 5th ed. S.S. Block (Ed.).
    • (2001) Disinfection, Sterilization, and Preservation , pp. 361-381
    • Scott, E.M.1    Gorman, S.P.2
  • 106
    • 0021957357 scopus 로고
    • The activity of glutaraldehyde against Clostridium difficile
    • Dyas A, Das BC The activity of glutaraldehyde against Clostridium difficile. J Hosp Infect 1985, 6:41-45.
    • (1985) J Hosp Infect , vol.6 , pp. 41-45
    • Dyas, A.1    Das, B.C.2
  • 107
    • 0027674673 scopus 로고
    • Glutaraldehyde resistant mycobacteria from endoscope washers
    • van Klingeren B, Pullen W Glutaraldehyde resistant mycobacteria from endoscope washers. J Hosp Infect 1993, 25:147-149.
    • (1993) J Hosp Infect , vol.25 , pp. 147-149
    • van Klingeren, B.1    Pullen, W.2
  • 108
    • 0030956701 scopus 로고    scopus 로고
    • Glutaraldehyde-resistant Mycobacterium chelonae from endoscope washer disinfectors
    • Griffiths PA, Babb JR, Bradley CR, et al. Glutaraldehyde-resistant Mycobacterium chelonae from endoscope washer disinfectors. J Appl Microbiol 1997, 82:519-526.
    • (1997) J Appl Microbiol , vol.82 , pp. 519-526
    • Griffiths, P.A.1    Babb, J.R.2    Bradley, C.R.3
  • 109
    • 84868199861 scopus 로고    scopus 로고
    • Aldehyde-resistant mycobacteria bacteria associated with the use of endoscope reprocessing systems
    • Fisher CW, Fiorello A, Shaffer D, et al. Aldehyde-resistant mycobacteria bacteria associated with the use of endoscope reprocessing systems. Am J Infect Control 2012, 40:880-882.
    • (2012) Am J Infect Control , vol.40 , pp. 880-882
    • Fisher, C.W.1    Fiorello, A.2    Shaffer, D.3
  • 110
    • 84899563291 scopus 로고    scopus 로고
    • Microbial contamination of activated 2% glutaraldehyde used in high-level disinfection of endoscopes [abstract]
    • Webster E, Ribner B, Streed LL, et al. Microbial contamination of activated 2% glutaraldehyde used in high-level disinfection of endoscopes [abstract]. Am J Infect Control 1996, 24:153.
    • (1996) Am J Infect Control , vol.24 , pp. 153
    • Webster, E.1    Ribner, B.2    Streed, L.L.3
  • 111
    • 0032931401 scopus 로고    scopus 로고
    • Inactivation of Cryptosporidium parvum oocyst infectivity by disinfection and sterilization processes
    • Barbee SL, Weber DJ, Sobsey MD, Rutala WA Inactivation of Cryptosporidium parvum oocyst infectivity by disinfection and sterilization processes. Gastrointest Endosc 1999, 49:605-611.
    • (1999) Gastrointest Endosc , vol.49 , pp. 605-611
    • Barbee, S.L.1    Weber, D.J.2    Sobsey, M.D.3    Rutala, W.A.4
  • 112
    • 0017722308 scopus 로고
    • Fastidious mycobacteria grown from porcine prosthetic-heart-valve cultures
    • Laskowski LF, Marr JJ, Spernoga JF, et al. Fastidious mycobacteria grown from porcine prosthetic-heart-valve cultures. N Engl J Med 1977, 297:101-102.
    • (1977) N Engl J Med , vol.297 , pp. 101-102
    • Laskowski, L.F.1    Marr, J.J.2    Spernoga, J.F.3
  • 113
    • 69449083445 scopus 로고    scopus 로고
    • Rapidly growing mycobacteria infection after videosurgical procedures-the glutaraldehyde hypothesis
    • Lorena NS, Duarte RS, Pitombo MB Rapidly growing mycobacteria infection after videosurgical procedures-the glutaraldehyde hypothesis. Rev Col Bras Cir 2009, 36:266-267.
    • (2009) Rev Col Bras Cir , vol.36 , pp. 266-267
    • Lorena, N.S.1    Duarte, R.S.2    Pitombo, M.B.3
  • 114
    • 70349127307 scopus 로고    scopus 로고
    • Role of porins in the susceptibility of Mycobacterium smegmatis and Mycobacterium chelonae to aldehyde-based disinfectants and drugs
    • Svetlikova Z, Skovierova H, Niederweis M, et al. Role of porins in the susceptibility of Mycobacterium smegmatis and Mycobacterium chelonae to aldehyde-based disinfectants and drugs. Antimicrob Agents Chemother 2009, 53:4015-4018.
    • (2009) Antimicrob Agents Chemother , vol.53 , pp. 4015-4018
    • Svetlikova, Z.1    Skovierova, H.2    Niederweis, M.3
  • 115
    • 0027444731 scopus 로고
    • Bactericidal, virucidal, and mycobactericidal activities of reused alkaline glutaraldehyde in an endoscopy unit
    • Mbithi JN, Springthorpe VS, Sattar SA, et al. Bactericidal, virucidal, and mycobactericidal activities of reused alkaline glutaraldehyde in an endoscopy unit. J Clin Microbiol 1993, 31:2988-2995.
    • (1993) J Clin Microbiol , vol.31 , pp. 2988-2995
    • Mbithi, J.N.1    Springthorpe, V.S.2    Sattar, S.A.3
  • 116
    • 0025311776 scopus 로고
    • Effect of methodology, dilution, and exposure time on the tuberculocidal activity of glutaraldehyde-based disinfectants
    • Cole EC, Rutala WA, Nessen L, et al. Effect of methodology, dilution, and exposure time on the tuberculocidal activity of glutaraldehyde-based disinfectants. Appl Environ Microbiol 1990, 56:1813-1817.
    • (1990) Appl Environ Microbiol , vol.56 , pp. 1813-1817
    • Cole, E.C.1    Rutala, W.A.2    Nessen, L.3
  • 117
    • 0017152792 scopus 로고
    • Mycobactericidal activity of glutaraldehyde solutions
    • Collins FM, Montalbine V Mycobactericidal activity of glutaraldehyde solutions. J Clin Microbiol 1976, 4:408-412.
    • (1976) J Clin Microbiol , vol.4 , pp. 408-412
    • Collins, F.M.1    Montalbine, V.2
  • 118
    • 0024624227 scopus 로고
    • Glutaraldehyde test kits: evaluation for accuracy and range
    • Overton D, Burgess JO, Beck B, et al. Glutaraldehyde test kits: evaluation for accuracy and range. Gen Dent 1989, 37:126.
    • (1989) Gen Dent , vol.37 , pp. 126
    • Overton, D.1    Burgess, J.O.2    Beck, B.3
  • 119
    • 0034920346 scopus 로고    scopus 로고
    • Monitoring glutaraldehyde dilution in automated washer/disinfectors
    • Cooke RPD, Goddard SV, Chatterley R, et al. Monitoring glutaraldehyde dilution in automated washer/disinfectors. J Hosp Infect 2001, 48:242-246.
    • (2001) J Hosp Infect , vol.48 , pp. 242-246
    • Cooke, R.P.D.1    Goddard, S.V.2    Chatterley, R.3
  • 120
    • 0033373612 scopus 로고    scopus 로고
    • Residual glutaraldehyde levels in fiberoptic endoscopes: measurement and implications for patient toxicity
    • Farina A, Fievet MH, Plassart F, et al. Residual glutaraldehyde levels in fiberoptic endoscopes: measurement and implications for patient toxicity. J Hosp Infect 1999, 43:293-297.
    • (1999) J Hosp Infect , vol.43 , pp. 293-297
    • Farina, A.1    Fievet, M.H.2    Plassart, F.3
  • 122
    • 0026874485 scopus 로고
    • Glutaraldehyde: a potential health risk to nurses
    • Newman MA, Kachuba JB Glutaraldehyde: a potential health risk to nurses. Gastroenterol Nurs 1992, 14:296-300.
    • (1992) Gastroenterol Nurs , vol.14 , pp. 296-300
    • Newman, M.A.1    Kachuba, J.B.2
  • 123
    • 0002873317 scopus 로고
    • Hydrogen peroxide and other oxidant disinfectants
    • Lea & Febiger, Philadelphia, S.S. Block (Ed.), 3rd ed.
    • Turner FJ Hydrogen peroxide and other oxidant disinfectants. Disinfection, Sterilization, and Preservation 1983, 240-250. Lea & Febiger, Philadelphia. 3rd ed. S.S. Block (Ed.).
    • (1983) Disinfection, Sterilization, and Preservation , pp. 240-250
    • Turner, F.J.1
  • 124
    • 0000103325 scopus 로고    scopus 로고
    • Peroxygen compounds
    • Lippincott Williams & Wilkins, Philadelphia, S.S. Block (Ed.), 5th ed.
    • Block SS Peroxygen compounds. Disinfection, Sterilization, and Preservation 2001, 185-204. Lippincott Williams & Wilkins, Philadelphia. 5th ed. S.S. Block (Ed.).
    • (2001) Disinfection, Sterilization, and Preservation , pp. 185-204
    • Block, S.S.1
  • 125
    • 0000417496 scopus 로고    scopus 로고
    • A product based on accelerated and stabilized hydrogen peroxide: evidence for broad-spectrum germicidal activity
    • Sattar SA, Springthorpe VS, Rochon M A product based on accelerated and stabilized hydrogen peroxide: evidence for broad-spectrum germicidal activity. Can J Infect Control 1998, (Winter):123-130.
    • (1998) Can J Infect Control , Issue.WINTER , pp. 123-130
    • Sattar, S.A.1    Springthorpe, V.S.2    Rochon, M.3
  • 127
    • 79951854001 scopus 로고    scopus 로고
    • Innate resistance to sporicides and potential failure to decontaminate
    • Maillard J-Y Innate resistance to sporicides and potential failure to decontaminate. J Hosp Infect 2011, 77:204-209.
    • (2011) J Hosp Infect , vol.77 , pp. 204-209
    • Maillard, J.-Y.1
  • 128
    • 0025256009 scopus 로고
    • The effect of currently available contact lens disinfection systems on Acanthamoeba castellanii and Acanthamoeba polyphaga
    • Silvany RE, Dougherty JM, McCulley JP, et al. The effect of currently available contact lens disinfection systems on Acanthamoeba castellanii and Acanthamoeba polyphaga. Ophthalmology 1990, 97:286-290.
    • (1990) Ophthalmology , vol.97 , pp. 286-290
    • Silvany, R.E.1    Dougherty, J.M.2    McCulley, J.P.3
  • 129
    • 0033429347 scopus 로고    scopus 로고
    • The 1999 Lindberg award. 3% hydrogen peroxide for the gram-positive disinfection of fabrics
    • Neely AN, Maley MP The 1999 Lindberg award. 3% hydrogen peroxide for the gram-positive disinfection of fabrics. J Burn Care Rehabil 1999, 20:471-477.
    • (1999) J Burn Care Rehabil , vol.20 , pp. 471-477
    • Neely, A.N.1    Maley, M.P.2
  • 130
    • 0027078788 scopus 로고
    • Significant factors in the disinfection and sterilization of flexible endoscopes
    • Vesley D, Norlien KG, Nelson B, et al. Significant factors in the disinfection and sterilization of flexible endoscopes. Am J Infect Control 1992, 20:291-300.
    • (1992) Am J Infect Control , vol.20 , pp. 291-300
    • Vesley, D.1    Norlien, K.G.2    Nelson, B.3
  • 131
    • 0024708358 scopus 로고
    • Corneal damage from improperly cleaned tonometer tips
    • Levenson JE Corneal damage from improperly cleaned tonometer tips. Arch Ophthalmol 1989, 107:1117.
    • (1989) Arch Ophthalmol , vol.107 , pp. 1117
    • Levenson, J.E.1
  • 132
    • 33744505789 scopus 로고    scopus 로고
    • Broad-spectrum microbicidal activity, toxicologic assessment, and materials compatibility of a new generation of accelerated hydrogen peroxide-based environmental surface disinfectant
    • Omidbakhsh N, Sattar SA Broad-spectrum microbicidal activity, toxicologic assessment, and materials compatibility of a new generation of accelerated hydrogen peroxide-based environmental surface disinfectant. Am J Infect Control 2006, 34:251-257.
    • (2006) Am J Infect Control , vol.34 , pp. 251-257
    • Omidbakhsh, N.1    Sattar, S.A.2
  • 133
    • 0036913683 scopus 로고    scopus 로고
    • Combined application of simulated reuse and quantitative carrier test to assess high-level disinfection: experiments with an accelerated hydrogen peroxide-based formulation
    • Sattar SA, Adegbunrin O, Ramirez J Combined application of simulated reuse and quantitative carrier test to assess high-level disinfection: experiments with an accelerated hydrogen peroxide-based formulation. Am J Infect Control 2002, 30:449-457.
    • (2002) Am J Infect Control , vol.30 , pp. 449-457
    • Sattar, S.A.1    Adegbunrin, O.2    Ramirez, J.3
  • 134
    • 33750626250 scopus 로고    scopus 로고
    • A new peroxide-based flexible endoscope-compatible high-level disinfectant
    • Omidbakhsh N A new peroxide-based flexible endoscope-compatible high-level disinfectant. Am J Infect Control 2006, 34:571-577.
    • (2006) Am J Infect Control , vol.34 , pp. 571-577
    • Omidbakhsh, N.1
  • 135
    • 50649104431 scopus 로고    scopus 로고
    • An accelerated hydrogen peroxide (AHP)-based fast-acting and reusable microbicide for manual disinfection of heat sensitive semi-critical medical devices
    • Omidbakhsh N, Kenny N An accelerated hydrogen peroxide (AHP)-based fast-acting and reusable microbicide for manual disinfection of heat sensitive semi-critical medical devices. Can J Infect Control 2008, 23:81-88.
    • (2008) Can J Infect Control , vol.23 , pp. 81-88
    • Omidbakhsh, N.1    Kenny, N.2
  • 136
    • 0004860719 scopus 로고    scopus 로고
    • Products based on accelerated and stabilized hydrogen peroxide: evidence for cleaning and sanitizing efficiency, environmental and human safety and non-corrosiveness
    • Rochon M, Sullivan N Products based on accelerated and stabilized hydrogen peroxide: evidence for cleaning and sanitizing efficiency, environmental and human safety and non-corrosiveness. Can J Infect Control 1999, (Summer):51-55.
    • (1999) Can J Infect Control , Issue.SUMMER , pp. 51-55
    • Rochon, M.1    Sullivan, N.2
  • 137
    • 0001187590 scopus 로고    scopus 로고
    • Iodine and iodine compounds
    • Lippincott Williams & Wilkins, Philadelphia, S.S. Block (Ed.), 5th ed.
    • Gottardi W Iodine and iodine compounds. Disinfection, Sterilization, and Preservation 2001, 159-184. Lippincott Williams & Wilkins, Philadelphia. 5th ed. S.S. Block (Ed.).
    • (2001) Disinfection, Sterilization, and Preservation , pp. 159-184
    • Gottardi, W.1
  • 138
    • 0019814415 scopus 로고
    • Pseudobacteremia caused by povidone-iodine solution contaminated with Pseudomonas cepacia
    • Craven DE, Moody B, Connolly MG, et al. Pseudobacteremia caused by povidone-iodine solution contaminated with Pseudomonas cepacia. N Engl J Med 1981, 305:621-623.
    • (1981) N Engl J Med , vol.305 , pp. 621-623
    • Craven, D.E.1    Moody, B.2    Connolly, M.G.3
  • 139
    • 0019466375 scopus 로고
    • Pseudobacteremia attributed to contamination of povidone-iodine with Pseudomonas cepacia
    • Berkelman RL, Lewin S, Allen JR, et al. Pseudobacteremia attributed to contamination of povidone-iodine with Pseudomonas cepacia. Ann Intern Med 1981, 95:32-36.
    • (1981) Ann Intern Med , vol.95 , pp. 32-36
    • Berkelman, R.L.1    Lewin, S.2    Allen, J.R.3
  • 141
    • 0026095191 scopus 로고
    • Inactivation of Mycobacterium tuberculosis and Mycobacterium bovis by 14 hospital disinfectants
    • Rutala WA, Cole EC, Wannamaker NS, et al. Inactivation of Mycobacterium tuberculosis and Mycobacterium bovis by 14 hospital disinfectants. Am J Med 1991, 91:267S-271S.
    • (1991) Am J Med , vol.91 , pp. 267S-271S
    • Rutala, W.A.1    Cole, E.C.2    Wannamaker, N.S.3
  • 143
    • 0020054111 scopus 로고
    • Increased bactericidal activity of dilute preparations of povidone-iodine solutions
    • Berkelman RL, Holland BW, Anderson RL Increased bactericidal activity of dilute preparations of povidone-iodine solutions. J Clin Microbiol 1982, 15:635-639.
    • (1982) J Clin Microbiol , vol.15 , pp. 635-639
    • Berkelman, R.L.1    Holland, B.W.2    Anderson, R.L.3
  • 144
    • 0018215516 scopus 로고
    • Wescodyne: lack of activity against poliovirus in the presence of organic matter
    • Wallbank AM, Drulak M, Poffenroth L, et al. Wescodyne: lack of activity against poliovirus in the presence of organic matter. Health Lab Sci 1978, 15:133-137.
    • (1978) Health Lab Sci , vol.15 , pp. 133-137
    • Wallbank, A.M.1    Drulak, M.2    Poffenroth, L.3
  • 145
    • 0002556667 scopus 로고    scopus 로고
    • Chemical disinfection of medical and surgical materials
    • Lea & Febiger, Philadelphia, S.S. Block (Ed.), 4th ed.
    • Favero MS, Bond WW Chemical disinfection of medical and surgical materials. Disinfection, Sterilization, and Preservation 1991, 617-641. Lea & Febiger, Philadelphia. 4th ed. S.S. Block (Ed.).
    • (1991) Disinfection, Sterilization, and Preservation , pp. 617-641
    • Favero, M.S.1    Bond, W.W.2
  • 146
    • 84944621454 scopus 로고    scopus 로고
    • Accessed June 2000
    • Medcom Frequently Asked Questions Available at, Accessed June 2000. http://www.medcompnet.com/faq/faq/html.
  • 147
    • 0028181530 scopus 로고
    • Enhancement of mycobactericidal activity of glutaraldehyde with α,β-unsaturated and aromatic aldehydes
    • Gordon MD, Ezzell RJ, Bruckner NI, et al. Enhancement of mycobactericidal activity of glutaraldehyde with α,β-unsaturated and aromatic aldehydes. J Indus Microbiol 1994, 13:77-82.
    • (1994) J Indus Microbiol , vol.13 , pp. 77-82
    • Gordon, M.D.1    Ezzell, R.J.2    Bruckner, N.I.3
  • 148
    • 0035032162 scopus 로고    scopus 로고
    • New disinfection and sterilization methods
    • Rutala WA, Weber DJ New disinfection and sterilization methods. Emerg Infect Dis 2001, 7:348-353.
    • (2001) Emerg Infect Dis , vol.7 , pp. 348-353
    • Rutala, W.A.1    Weber, D.J.2
  • 149
    • 0033126393 scopus 로고    scopus 로고
    • The mycobactericidal efficacy of ortho-phthalaldehyde and the comparative resistances of Mycobacterium bovis, Mycobacterium terrae, and Mycobacterium chelonae
    • Gregory AW, Schaalje GB, Smart JD, et al. The mycobactericidal efficacy of ortho-phthalaldehyde and the comparative resistances of Mycobacterium bovis, Mycobacterium terrae, and Mycobacterium chelonae. Infect Control Hosp Epidemiol 1999, 20:324-330.
    • (1999) Infect Control Hosp Epidemiol , vol.20 , pp. 324-330
    • Gregory, A.W.1    Schaalje, G.B.2    Smart, J.D.3
  • 150
    • 0032977409 scopus 로고    scopus 로고
    • Ortho-phthalaldehyde: a possible alternative to glutaraldehyde for high level disinfection
    • Walsh SE, Maillard JY, Russell AD Ortho-phthalaldehyde: a possible alternative to glutaraldehyde for high level disinfection. J Appl Microbiol 1999, 86:1039-1046.
    • (1999) J Appl Microbiol , vol.86 , pp. 1039-1046
    • Walsh, S.E.1    Maillard, J.Y.2    Russell, A.D.3
  • 151
    • 0027954617 scopus 로고
    • In-hospital evaluation of ortho-phthalaldehyde as a high level disinfectant for flexible endoscopes
    • Alfa MJ, Sitter DL In-hospital evaluation of ortho-phthalaldehyde as a high level disinfectant for flexible endoscopes. J Hosp Infect 1994, 26:15-26.
    • (1994) J Hosp Infect , vol.26 , pp. 15-26
    • Alfa, M.J.1    Sitter, D.L.2
  • 152
    • 40949107723 scopus 로고    scopus 로고
    • Virucidal activity of ortho-phthalaldehyde solutions against hepatitis B and C viruses
    • Roberts CG, Chan-Myers HB, Favero MS Virucidal activity of ortho-phthalaldehyde solutions against hepatitis B and C viruses. Am J Infect Control 2008, 36:223-226.
    • (2008) Am J Infect Control , vol.36 , pp. 223-226
    • Roberts, C.G.1    Chan-Myers, H.B.2    Favero, M.S.3
  • 153
    • 4344609711 scopus 로고    scopus 로고
    • Nine episodes of anaphylaxis following cystoscopy caused by Cidex OPA (ortho-phthalaldehyde) high-level disinfectant in 4 patients after cystoscopy
    • Sokol WN Nine episodes of anaphylaxis following cystoscopy caused by Cidex OPA (ortho-phthalaldehyde) high-level disinfectant in 4 patients after cystoscopy. J Allergy Clin Immunol 2004, 114:392-397.
    • (2004) J Allergy Clin Immunol , vol.114 , pp. 392-397
    • Sokol, W.N.1
  • 154
    • 77954672477 scopus 로고    scopus 로고
    • Ortho-phthalaldehyde exposure levels among endoscope disinfection workers
    • Miyajima K, Yoshida J, Kumagai S Ortho-phthalaldehyde exposure levels among endoscope disinfection workers. Sangyo Eiseigaku Zasshi 2010, 52:74.
    • (2010) Sangyo Eiseigaku Zasshi , vol.52 , pp. 74
    • Miyajima, K.1    Yoshida, J.2    Kumagai, S.3
  • 155
    • 0030200855 scopus 로고    scopus 로고
    • Surface analysis of clinically used expanded PTFE endoscopic tubing treated by the STERIS PROCESS
    • Tucker RC, Lestini BJ, Marchant RE Surface analysis of clinically used expanded PTFE endoscopic tubing treated by the STERIS PROCESS. ASAIO J 1996, 42:306-313.
    • (1996) ASAIO J , vol.42 , pp. 306-313
    • Tucker, R.C.1    Lestini, B.J.2    Marchant, R.E.3
  • 156
    • 84944536982 scopus 로고    scopus 로고
    • U.S.Food and Drug Administration Steris System 1E Liquid Chemical Sterilant Available at. http://wwwfdagov/MedicalDevices/ProductsandMedicalProcedures/DeviceApprovalsandClearances/Recently-ApprovedDevices/ucm207489htm.
    • Steris System 1E Liquid Chemical Sterilant
  • 157
    • 21344463920 scopus 로고    scopus 로고
    • Medical applications of peracetic acid
    • Lippincott Williams & Wilkins, Philadelphia, S.S. Block (Ed.), 5th ed.
    • Malchesky PS Medical applications of peracetic acid. Disinfection, Sterilization, and Preservation 2001, 979-996. Lippincott Williams & Wilkins, Philadelphia. 5th ed. S.S. Block (Ed.).
    • (2001) Disinfection, Sterilization, and Preservation , pp. 979-996
    • Malchesky, P.S.1
  • 158
    • 0029285616 scopus 로고
    • The use of peracetic acid for the reprocessing of flexible endoscopes and rigid cystoscopes and laparoscopes
    • Mannion PT The use of peracetic acid for the reprocessing of flexible endoscopes and rigid cystoscopes and laparoscopes. J Hosp Infect 1995, 29:313-315.
    • (1995) J Hosp Infect , vol.29 , pp. 313-315
    • Mannion, P.T.1
  • 159
    • 0028956283 scopus 로고
    • Evaluation of the Steris System 1 Peracetic Acid Endoscope Processor
    • Bradley CR, Babb JR, Ayliffe GA Evaluation of the Steris System 1 Peracetic Acid Endoscope Processor. J Hosp Infect 1995, 29:143-151.
    • (1995) J Hosp Infect , vol.29 , pp. 143-151
    • Bradley, C.R.1    Babb, J.R.2    Ayliffe, G.A.3
  • 160
    • 0034919807 scopus 로고    scopus 로고
    • Evaluation of the microbicidal efficacy of Steris System 1 for digestive endoscopes using GERMANDE and ASTM validation protocols
    • Duc DL, Ribiollet A, Dode X, et al. Evaluation of the microbicidal efficacy of Steris System 1 for digestive endoscopes using GERMANDE and ASTM validation protocols. J Hosp Infect 2001, 48:135-141.
    • (2001) J Hosp Infect , vol.48 , pp. 135-141
    • Duc, D.L.1    Ribiollet, A.2    Dode, X.3
  • 161
    • 0346554265 scopus 로고    scopus 로고
    • New low temperature sterilization technologies: microbicidal activity and clinical efficacy
    • Polyscience Publications, Champlain, NY, W.A. Rutala (Ed.)
    • Alfa MJ, Olson N, Degagne P, et al. New low temperature sterilization technologies: microbicidal activity and clinical efficacy. Disinfection, Sterilization, and Antisepsis in Healthcare 1998, 67-78. Polyscience Publications, Champlain, NY. W.A. Rutala (Ed.).
    • (1998) Disinfection, Sterilization, and Antisepsis in Healthcare , pp. 67-78
    • Alfa, M.J.1    Olson, N.2    Degagne, P.3
  • 162
    • 0031784234 scopus 로고    scopus 로고
    • Comparison of liquid chemical sterilization with peracetic acid and ethylene oxide sterilization for long narrow lumens
    • Alfa MJ, DeGagne P, Olson N, et al. Comparison of liquid chemical sterilization with peracetic acid and ethylene oxide sterilization for long narrow lumens. Am J Infect Control 1998, 26:469-477.
    • (1998) Am J Infect Control , vol.26 , pp. 469-477
    • Alfa, M.J.1    DeGagne, P.2    Olson, N.3
  • 163
    • 0343990780 scopus 로고    scopus 로고
    • Liquid sterilization versus high level disinfection in the urologic office
    • Fuselier HA, Mason C Liquid sterilization versus high level disinfection in the urologic office. Urology 1997, 50:337-340.
    • (1997) Urology , vol.50 , pp. 337-340
    • Fuselier, H.A.1    Mason, C.2
  • 164
    • 0004511249 scopus 로고
    • Clinical evaluation of a liquid chemical sterilization system for flexible bronchoscopes
    • Seballos RJ, Walsh AL, Mehta AC Clinical evaluation of a liquid chemical sterilization system for flexible bronchoscopes. J Bronch 1995, 2:192-199.
    • (1995) J Bronch , vol.2 , pp. 192-199
    • Seballos, R.J.1    Walsh, A.L.2    Mehta, A.C.3
  • 165
    • 0029059876 scopus 로고
    • Liquid chemical sterilization using peracetic acid: an alternative approach to endoscope processing
    • Wallace CG, Agee PM, Demicco DD Liquid chemical sterilization using peracetic acid: an alternative approach to endoscope processing. ASAIO J 1995, 41:151-154.
    • (1995) ASAIO J , vol.41 , pp. 151-154
    • Wallace, C.G.1    Agee, P.M.2    Demicco, D.D.3
  • 166
    • 0033538360 scopus 로고    scopus 로고
    • Bronchoscopy-related infections and pseudoinfections-New York, 1996 and 1998
    • Centers for Disease Control and Prevention Bronchoscopy-related infections and pseudoinfections-New York, 1996 and 1998. MMWR Morb Mortal Wkly Rep 1999, 48:557-560.
    • (1999) MMWR Morb Mortal Wkly Rep , vol.48 , pp. 557-560
  • 168
    • 0030781640 scopus 로고    scopus 로고
    • Disinfection of bronchoscopes, contaminated in vitro with Mycobacterium tuberculosis, Mycobacterium avium-intracellulare and Mycobacterium chelonae in sputum, using stabilized, buffered peracetic acid solution ('Nu-Cidex
    • Middleton AM, Chadwick MV, Gaya H Disinfection of bronchoscopes, contaminated in vitro with Mycobacterium tuberculosis, Mycobacterium avium-intracellulare and Mycobacterium chelonae in sputum, using stabilized, buffered peracetic acid solution ('Nu-Cidex. J Hosp Infect 1997, 37:137-143.
    • (1997) J Hosp Infect , vol.37 , pp. 137-143
    • Middleton, A.M.1    Chadwick, M.V.2    Gaya, H.3
  • 169
    • 0030983021 scopus 로고    scopus 로고
    • In-use stability of Nu-Cidex
    • Holton J, Shetty N In-use stability of Nu-Cidex. J Hosp Infect 1997, 35:245-248.
    • (1997) J Hosp Infect , vol.35 , pp. 245-248
    • Holton, J.1    Shetty, N.2
  • 170
    • 0026675476 scopus 로고
    • Bactericidal properties of peracetic acid and hydrogen peroxide, alone and in combination, and chlorine and formaldehyde against bacterial water strains
    • Alasri A, Roques C, Michel G, et al. Bactericidal properties of peracetic acid and hydrogen peroxide, alone and in combination, and chlorine and formaldehyde against bacterial water strains. Can J Microbiol 1992, 38:635-642.
    • (1992) Can J Microbiol , vol.38 , pp. 635-642
    • Alasri, A.1    Roques, C.2    Michel, G.3
  • 171
    • 1842572564 scopus 로고    scopus 로고
    • Destruction of a glutaraldehyde-resistant mycobacterium by a per-oxygen disinfectant [abstract]
    • Stanley P Destruction of a glutaraldehyde-resistant mycobacterium by a per-oxygen disinfectant [abstract]. Am J Infect Control 1998, 26:185.
    • (1998) Am J Infect Control , vol.26 , pp. 185
    • Stanley, P.1
  • 173
    • 14844335024 scopus 로고    scopus 로고
    • National surveillance of dialysis-associated diseases in the United States, 2002
    • Finelli L, Miller JT, Tokars JI, et al. National surveillance of dialysis-associated diseases in the United States, 2002. Semin Dial 2005, 18:52-61.
    • (2005) Semin Dial , vol.18 , pp. 52-61
    • Finelli, L.1    Miller, J.T.2    Tokars, J.I.3
  • 174
    • 0023463444 scopus 로고
    • Ineffectiveness of hospital disinfectants against bacteria: a collaborative study
    • Rutala WA, Cole EC Ineffectiveness of hospital disinfectants against bacteria: a collaborative study. Infect Control 1987, 8:501-506.
    • (1987) Infect Control , vol.8 , pp. 501-506
    • Rutala, W.A.1    Cole, E.C.2
  • 175
    • 0346291076 scopus 로고
    • Phenolic compounds
    • Lea & Febiger, Philadelphia, S.S. Block (Ed.), 3rd ed.
    • Prindle RF Phenolic compounds. Disinfection, Sterilization, and Preservation 1983, 197-224. Lea & Febiger, Philadelphia. 3rd ed. S.S. Block (Ed.).
    • (1983) Disinfection, Sterilization, and Preservation , pp. 197-224
    • Prindle, R.F.1
  • 176
    • 0024116169 scopus 로고
    • Disinfectant testing using a modified use-dilution method: collaborative study
    • Cole EC, Rutala WA, Samsa GP Disinfectant testing using a modified use-dilution method: collaborative study. J Assoc Off Anal Chem 1988, 71:1187-1194.
    • (1988) J Assoc Off Anal Chem , vol.71 , pp. 1187-1194
    • Cole, E.C.1    Rutala, W.A.2    Samsa, G.P.3
  • 177
    • 0242483474 scopus 로고    scopus 로고
    • Phenolic compounds
    • Lippincott Williams & Wilkins, Philadelphia, S.S. Block (Ed.), 5th ed.
    • Goddard PA, McCue KA Phenolic compounds. Disinfection, Sterilization, and Preservation 2001, 255-281. Lippincott Williams & Wilkins, Philadelphia. 5th ed. S.S. Block (Ed.).
    • (2001) Disinfection, Sterilization, and Preservation , pp. 255-281
    • Goddard, P.A.1    McCue, K.A.2
  • 178
    • 0030786952 scopus 로고    scopus 로고
    • Comparative sensitivity of 13 species of pathogenic bacteria to seven chemical germicides
    • Sagripanti JL, Eklund CA, Trost PA, et al. Comparative sensitivity of 13 species of pathogenic bacteria to seven chemical germicides. Am J Infect Control 1997, 25:335-339.
    • (1997) Am J Infect Control , vol.25 , pp. 335-339
    • Sagripanti, J.L.1    Eklund, C.A.2    Trost, P.A.3
  • 179
    • 0018091405 scopus 로고
    • Epidemic neonatal hyperbilirubinemia and use of a phenolic disinfectant detergent
    • Wysowski DK, Flynt JW, Goldfield M, et al. Epidemic neonatal hyperbilirubinemia and use of a phenolic disinfectant detergent. Pediatrics 1978, 61:165-170.
    • (1978) Pediatrics , vol.61 , pp. 165-170
    • Wysowski, D.K.1    Flynt, J.W.2    Goldfield, M.3
  • 181
    • 84965092276 scopus 로고
    • Bacteremia following cardiac catheterization
    • Shickman MD, Guze LB, Pearce ML Bacteremia following cardiac catheterization. N Engl J Med 1959, 260:1164-1166.
    • (1959) N Engl J Med , vol.260 , pp. 1164-1166
    • Shickman, M.D.1    Guze, L.B.2    Pearce, M.L.3
  • 182
    • 0019225287 scopus 로고
    • Antibiotic-sensitive Serratia marcescens infections complicating cardiopulmonary operations: contaminated disinfectant as a reservoir
    • Ehrenkranz NJ, Bolyard EA, Wiener M, et al. Antibiotic-sensitive Serratia marcescens infections complicating cardiopulmonary operations: contaminated disinfectant as a reservoir. Lancet 1980, 2:1289-1292.
    • (1980) Lancet , vol.2 , pp. 1289-1292
    • Ehrenkranz, N.J.1    Bolyard, E.A.2    Wiener, M.3
  • 183
    • 0025133031 scopus 로고
    • Chemical disinfection of hepatitis A virus on environmental surfaces
    • Mbithi JN, Springthorpe VS, Sattar SA Chemical disinfection of hepatitis A virus on environmental surfaces. Appl Environ Microbiol 1990, 56:3601-3604.
    • (1990) Appl Environ Microbiol , vol.56 , pp. 3601-3604
    • Mbithi, J.N.1    Springthorpe, V.S.2    Sattar, S.A.3
  • 184
    • 0002156590 scopus 로고
    • Surface active agents: quaternary ammonium compounds
    • Lea & Febiger, Philadelphia, S.S. Block (Ed.), 3rd ed.
    • Petrocci AN Surface active agents: quaternary ammonium compounds. Disinfection, Sterilization, and Preservation 1983, 309-329. Lea & Febiger, Philadelphia. 3rd ed. S.S. Block (Ed.).
    • (1983) Disinfection, Sterilization, and Preservation , pp. 309-329
    • Petrocci, A.N.1
  • 185
    • 0032925758 scopus 로고    scopus 로고
    • Inactivation of feline calicivirus, a Norwalk virus surrogate
    • Doultree JC, Druce JD, Birch CJ, et al. Inactivation of feline calicivirus, a Norwalk virus surrogate. J Hosp Infect 1999, 41:51-57.
    • (1999) J Hosp Infect , vol.41 , pp. 51-57
    • Doultree, J.C.1    Druce, J.D.2    Birch, C.J.3
  • 186
    • 0025361756 scopus 로고
    • An outbreak of respiratory tract infection resulting from incomplete disinfection of ventilatory equipment
    • Cefai C, Richards J, Gould FK, et al. An outbreak of respiratory tract infection resulting from incomplete disinfection of ventilatory equipment. J Hosp Infect 1990, 15:177-182.
    • (1990) J Hosp Infect , vol.15 , pp. 177-182
    • Cefai, C.1    Richards, J.2    Gould, F.K.3
  • 187
    • 0021030954 scopus 로고
    • Disinfection of respirator tubing: a comparison of chemical versus hot water machine-assisted processing
    • Gurevich I, Tafuro P, Ristuccia P, et al. Disinfection of respirator tubing: a comparison of chemical versus hot water machine-assisted processing. J Hosp Infect 1983, 4:199-208.
    • (1983) J Hosp Infect , vol.4 , pp. 199-208
    • Gurevich, I.1    Tafuro, P.2    Ristuccia, P.3
  • 188
    • 0034185895 scopus 로고    scopus 로고
    • Efficacy of a washer-pasteurizer for disinfection of respiratory-care equipment
    • Rutala WA, Weber DJ, Gergen MF, et al. Efficacy of a washer-pasteurizer for disinfection of respiratory-care equipment. Infect Control Hosp Epidemiol 2000, 21:333-336.
    • (2000) Infect Control Hosp Epidemiol , vol.21 , pp. 333-336
    • Rutala, W.A.1    Weber, D.J.2    Gergen, M.F.3
  • 189
    • 0024008863 scopus 로고
    • Evaluation of two hot water washer disinfectors for medical instruments
    • Jette LP, Lambert NG Evaluation of two hot water washer disinfectors for medical instruments. Infect Control Hosp Epidemiol 1988, 9:194-199.
    • (1988) Infect Control Hosp Epidemiol , vol.9 , pp. 194-199
    • Jette, L.P.1    Lambert, N.G.2
  • 190
    • 60549087175 scopus 로고    scopus 로고
    • Dose requirements for UVC disinfection of catheter biofilms
    • Bak J, Ladefoged SD, Tvede M, et al. Dose requirements for UVC disinfection of catheter biofilms. Biofouling 2009, 25:289-296.
    • (2009) Biofouling , vol.25 , pp. 289-296
    • Bak, J.1    Ladefoged, S.D.2    Tvede, M.3
  • 191
    • 33947718016 scopus 로고    scopus 로고
    • Evaluation of a new disinfection procedure for ultrasound probes using ultraviolet light
    • Kac G, Gueneret M, Rodi A, et al. Evaluation of a new disinfection procedure for ultrasound probes using ultraviolet light. J Hosp Infect 2007, 65:163-168.
    • (2007) J Hosp Infect , vol.65 , pp. 163-168
    • Kac, G.1    Gueneret, M.2    Rodi, A.3
  • 192
    • 36148984113 scopus 로고    scopus 로고
    • Disinfection of Acinetobacter baumannii-contaminated surfaces relevant to medical treatment facilities with ultraviolet C light
    • Rastogi VK, Wallace L, Smith LS Disinfection of Acinetobacter baumannii-contaminated surfaces relevant to medical treatment facilities with ultraviolet C light. Mil Med 2007, 172:1166-1169.
    • (2007) Mil Med , vol.172 , pp. 1166-1169
    • Rastogi, V.K.1    Wallace, L.2    Smith, L.S.3
  • 193
    • 84861014016 scopus 로고    scopus 로고
    • Evaluation of a hand-held far-ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens
    • Nerandzic MM, Cadnum JL, Eckart KE, et al. Evaluation of a hand-held far-ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens. BMC Infect Dis 2012, 12:120.
    • (2012) BMC Infect Dis , vol.12 , pp. 120
    • Nerandzic, M.M.1    Cadnum, J.L.2    Eckart, K.E.3
  • 195
    • 0031749365 scopus 로고    scopus 로고
    • Outbreak of viral hepatitis B in a rural community in India linked to inadequately sterilized needles and syringes
    • Singh J, Bhatia R, Gandhi JC, et al. Outbreak of viral hepatitis B in a rural community in India linked to inadequately sterilized needles and syringes. Bull World Health Organ 1998, 76:93-98.
    • (1998) Bull World Health Organ , vol.76 , pp. 93-98
    • Singh, J.1    Bhatia, R.2    Gandhi, J.C.3
  • 196
    • 0342643036 scopus 로고
    • An outbreak of surgical wound infections due to Clostridium perfringens
    • Eickhoff TC An outbreak of surgical wound infections due to Clostridium perfringens. Surg Gynecol Obstet 1962, 114:102-108.
    • (1962) Surg Gynecol Obstet , vol.114 , pp. 102-108
    • Eickhoff, T.C.1
  • 197
    • 80955148222 scopus 로고    scopus 로고
    • Outbreak of Pseudomonas aeruginosa surgical site infections after arthroscopic procedures: Texas, 2009
    • Tosh PK, Disbot M, Duffy JM, et al. Outbreak of Pseudomonas aeruginosa surgical site infections after arthroscopic procedures: Texas, 2009. Infect Control Hosp Epidemiol 2011, 32:1179-1186.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 1179-1186
    • Tosh, P.K.1    Disbot, M.2    Duffy, J.M.3
  • 198
    • 21644468535 scopus 로고    scopus 로고
    • Sterility assurance: concepts for patient safety
    • Association for Professional in Infection Control and Epidemiology, Washington, DC, W.A. Rutala (Ed.)
    • Favero MS Sterility assurance: concepts for patient safety. Disinfection, Sterilization and Antisepsis: Principles and Practices in Healthcare Facilities 2001, 110-119. Association for Professional in Infection Control and Epidemiology, Washington, DC. W.A. Rutala (Ed.).
    • (2001) Disinfection, Sterilization and Antisepsis: Principles and Practices in Healthcare Facilities , pp. 110-119
    • Favero, M.S.1
  • 199
    • 0002232195 scopus 로고
    • Sterility testing-validation of sterilization processes, and sporicide testing
    • Lea & Febiger, Philadelphia, S.S. Block (Ed.), 4th ed.
    • Oxborrow GS, Berube R Sterility testing-validation of sterilization processes, and sporicide testing. Disinfection, Sterilization, and Preservation 1991, 1047-1057. Lea & Febiger, Philadelphia. 4th ed. S.S. Block (Ed.).
    • (1991) Disinfection, Sterilization, and Preservation , pp. 1047-1057
    • Oxborrow, G.S.1    Berube, R.2
  • 200
    • 0032176559 scopus 로고    scopus 로고
    • Clinical effectiveness of low-temperature sterilization technologies
    • Rutala WA, Weber DJ Clinical effectiveness of low-temperature sterilization technologies. Infect Control Hosp Epidemiol 1998, 19:798-804.
    • (1998) Infect Control Hosp Epidemiol , vol.19 , pp. 798-804
    • Rutala, W.A.1    Weber, D.J.2
  • 201
    • 0031761157 scopus 로고    scopus 로고
    • Costs of low-temperature plasma sterilization compared with other sterilization methods
    • Adler S, Scherrer M, Daschner FD Costs of low-temperature plasma sterilization compared with other sterilization methods. J Hosp Infect 1998, 40:125-134.
    • (1998) J Hosp Infect , vol.40 , pp. 125-134
    • Adler, S.1    Scherrer, M.2    Daschner, F.D.3
  • 202
    • 0010798337 scopus 로고    scopus 로고
    • Sterilization by heat
    • Lippincott Williams & Wilkins, Philadelphia, S.S. Block (Ed.), 5th ed.
    • Joslyn L Sterilization by heat. Disinfection, Sterilization, and Preservation 2001, 695-728. Lippincott Williams & Wilkins, Philadelphia. 5th ed. S.S. Block (Ed.).
    • (2001) Disinfection, Sterilization, and Preservation , pp. 695-728
    • Joslyn, L.1
  • 203
    • 0033084816 scopus 로고    scopus 로고
    • Evaluation of sterilization of dental handpieces by heating in synthetic compressor lubricant
    • Silverstone SE, Hill DE Evaluation of sterilization of dental handpieces by heating in synthetic compressor lubricant. Gen Dent 1999, 47:158-160.
    • (1999) Gen Dent , vol.47 , pp. 158-160
    • Silverstone, S.E.1    Hill, D.E.2
  • 204
    • 0033980178 scopus 로고    scopus 로고
    • The effect of steam sterilization at 134 degrees C on light intensity provided by fibrelight Macintoch laryngoscopes
    • Bucx MJ, Veldman DJ, Beenhakker MM, et al. The effect of steam sterilization at 134 degrees C on light intensity provided by fibrelight Macintoch laryngoscopes. Anaesthesia 2000, 55:185-186.
    • (2000) Anaesthesia , vol.55 , pp. 185-186
    • Bucx, M.J.1    Veldman, D.J.2    Beenhakker, M.M.3
  • 205
    • 0021687271 scopus 로고
    • The effect of steam sterilization on plaster casting material
    • Gilbert JA, Phillips HO The effect of steam sterilization on plaster casting material. Clin Orthop Relat Res 1984, (190):241-244.
    • (1984) Clin Orthop Relat Res , Issue.190 , pp. 241-244
    • Gilbert, J.A.1    Phillips, H.O.2
  • 206
    • 0031225279 scopus 로고    scopus 로고
    • When the biological indicator is positive: investigating autoclave failures
    • Bryce EA, Roberts FJ, Clements B, et al. When the biological indicator is positive: investigating autoclave failures. Infect Control Hosp Epidemiol 1997, 18:654-656.
    • (1997) Infect Control Hosp Epidemiol , vol.18 , pp. 654-656
    • Bryce, E.A.1    Roberts, F.J.2    Clements, B.3
  • 207
    • 0020326367 scopus 로고
    • Decontamination of laboratory microbiological waste by steam sterilization
    • Rutala WA, Stiegel MM, Sarubbi FA Decontamination of laboratory microbiological waste by steam sterilization. Appl Environ Microbiol 1982, 43:1311-1316.
    • (1982) Appl Environ Microbiol , vol.43 , pp. 1311-1316
    • Rutala, W.A.1    Stiegel, M.M.2    Sarubbi, F.A.3
  • 208
    • 0026166541 scopus 로고
    • Disinfection and flash sterilization in the operating room
    • Rutala WA Disinfection and flash sterilization in the operating room. J Ophthalm Nurs Technol 1991, 10:106-115.
    • (1991) J Ophthalm Nurs Technol , vol.10 , pp. 106-115
    • Rutala, W.A.1
  • 209
    • 84876919548 scopus 로고    scopus 로고
    • Immediate use steam sterilization: moving beyond current policy
    • Seavey R Immediate use steam sterilization: moving beyond current policy. Am J Infect Control 2013, 41(5 suppl):S46-S48.
    • (2013) Am J Infect Control , vol.41 , Issue.5 , pp. S46-S48
    • Seavey, R.1
  • 210
    • 84876891985 scopus 로고    scopus 로고
    • Association for the Advancement of Medical Instrumentation, Accreditation Association for Ambulatory Health Care, Association of Perioperative Registered Nurses, et al. Immediate-Use Steam Sterilization Available at. http://www.aami.org/publications/standards/ST79_Immediate_Use_Statement.pdf.
    • Immediate-Use Steam Sterilization
  • 211
    • 84984085282 scopus 로고
    • Sterilization with gaseous ethylene oxide: a review of chemical and physical factors
    • Ernst RR, Doyle JE Sterilization with gaseous ethylene oxide: a review of chemical and physical factors. Biotech Bioeng 1968, 10:1-31.
    • (1968) Biotech Bioeng , vol.10 , pp. 1-31
    • Ernst, R.R.1    Doyle, J.E.2
  • 212
    • 0002242613 scopus 로고    scopus 로고
    • Gaseous chemical sterilization
    • Lippincott Williams & Wilkins, Philadelphia, S.S. Block (Ed.), 5th ed.
    • Joslyn L Gaseous chemical sterilization. Disinfection, Sterilization, and Preservation 2001, 337-360. Lippincott Williams & Wilkins, Philadelphia. 5th ed. S.S. Block (Ed.).
    • (2001) Disinfection, Sterilization, and Preservation , pp. 337-360
    • Joslyn, L.1
  • 215
    • 84944535807 scopus 로고    scopus 로고
    • U.S.Department of Health and Human Services.National Toxicology Program Available at. http://ntp-server.niehs.nih.gov/.
  • 216
    • 0028718408 scopus 로고
    • Ethylene oxide sterilization: how hospitals can adapt to the changes
    • Ethylene oxide sterilization: how hospitals can adapt to the changes. Health Devices 1994, 23:485-492.
    • (1994) Health Devices , vol.23 , pp. 485-492
  • 217
    • 0029999567 scopus 로고    scopus 로고
    • Safety and efficacy of ethylene oxide sterilized polyethylene in total knee arthroplasty
    • Ries MD, Weaver K, Beals N Safety and efficacy of ethylene oxide sterilized polyethylene in total knee arthroplasty. Clin Orthop Relat Res 1996, (331):159-163.
    • (1996) Clin Orthop Relat Res , Issue.331 , pp. 159-163
    • Ries, M.D.1    Weaver, K.2    Beals, N.3
  • 218
    • 0031230014 scopus 로고    scopus 로고
    • Bacterial killing ability of 10% ethylene oxide plus 90% hydrochlorofluorocarbon sterilizing gas
    • Alfa MJ, DeGagne P, Olson N Bacterial killing ability of 10% ethylene oxide plus 90% hydrochlorofluorocarbon sterilizing gas. Infect Control Hosp Epidemiol 1997, 18:641-645.
    • (1997) Infect Control Hosp Epidemiol , vol.18 , pp. 641-645
    • Alfa, M.J.1    DeGagne, P.2    Olson, N.3
  • 219
    • 0031874972 scopus 로고    scopus 로고
    • Comparative evaluation of the sporicidal activity of new low-temperature sterilization technologies: ethylene oxide, 2 plasma sterilization systems, and liquid peracetic acid
    • Rutala WA, Gergen MF, Weber DJ Comparative evaluation of the sporicidal activity of new low-temperature sterilization technologies: ethylene oxide, 2 plasma sterilization systems, and liquid peracetic acid. Am J Infect Control 1998, 26:393-398.
    • (1998) Am J Infect Control , vol.26 , pp. 393-398
    • Rutala, W.A.1    Gergen, M.F.2    Weber, D.J.3
  • 220
    • 0002225192 scopus 로고
    • Sterilization with ethylene oxide and other gases
    • Lea & Febiger, Philadelphia, S.S. Block (Ed.), 4th ed.
    • Parisi AN, Young WE Sterilization with ethylene oxide and other gases. Disinfection, Sterilization, and Preservation 1991, 580-595. Lea & Febiger, Philadelphia. 4th ed. S.S. Block (Ed.).
    • (1991) Disinfection, Sterilization, and Preservation , pp. 580-595
    • Parisi, A.N.1    Young, W.E.2
  • 221
    • 0027636853 scopus 로고
    • The efficacy of low temperature plasma (LTP) sterilization, a new sterilization technique
    • Holler C, Martiny H, Christiansen B, et al. The efficacy of low temperature plasma (LTP) sterilization, a new sterilization technique. Zentralbl Hyg Umweltmed 1993, 194:380-391.
    • (1993) Zentralbl Hyg Umweltmed , vol.194 , pp. 380-391
    • Holler, C.1    Martiny, H.2    Christiansen, B.3
  • 222
    • 0029285124 scopus 로고
    • Effectiveness of ethylene oxide for sterilization of dental handpieces
    • Parker HH, Johnson RB Effectiveness of ethylene oxide for sterilization of dental handpieces. J Dent 1995, 23:113-115.
    • (1995) J Dent , vol.23 , pp. 113-115
    • Parker, H.H.1    Johnson, R.B.2
  • 223
    • 0344310512 scopus 로고
    • Efficacy testing of low-temperature plasma sterilization (LTP) with test object models simulating practice conditions
    • Borneff M, Ruppert J, Okpara J, et al. Efficacy testing of low-temperature plasma sterilization (LTP) with test object models simulating practice conditions. Zentralbl Steril 1995, 3:361-371.
    • (1995) Zentralbl Steril , vol.3 , pp. 361-371
    • Borneff, M.1    Ruppert, J.2    Okpara, J.3
  • 224
    • 0002273170 scopus 로고    scopus 로고
    • Validation of low-temperature-plasma (LPT) sterilization systems: comparison of two technical versions, the Sterrad 100, 1.8 and the 100S
    • Borneff-Lipp M, Okpara J, Bodendorf M, et al. Validation of low-temperature-plasma (LPT) sterilization systems: comparison of two technical versions, the Sterrad 100, 1.8 and the 100S. Hyg Mikrobiol 1997, 3:21-28.
    • (1997) Hyg Mikrobiol , vol.3 , pp. 21-28
    • Borneff-Lipp, M.1    Okpara, J.2    Bodendorf, M.3
  • 225
    • 0013281061 scopus 로고    scopus 로고
    • Sterilization processes utilizing low-temperature plasma
    • Lippincott Williams & Wilkins, Philadelphia, S.S. Block (Ed.), 5th ed.
    • Jacobs PT, Lin SM Sterilization processes utilizing low-temperature plasma. Disinfection, Sterilization, and Preservation 2001, 747-763. Lippincott Williams & Wilkins, Philadelphia. 5th ed. S.S. Block (Ed.).
    • (2001) Disinfection, Sterilization, and Preservation , pp. 747-763
    • Jacobs, P.T.1    Lin, S.M.2
  • 226
    • 0033160447 scopus 로고    scopus 로고
    • Sporicidal activity of a new low-temperature sterilization technology: the Sterrad 50 sterilizer
    • Rutala WA, Gergen MF, Weber DJ Sporicidal activity of a new low-temperature sterilization technology: the Sterrad 50 sterilizer. Infect Control Hosp Epidemiol 1999, 20:514-516.
    • (1999) Infect Control Hosp Epidemiol , vol.20 , pp. 514-516
    • Rutala, W.A.1    Gergen, M.F.2    Weber, D.J.3
  • 227
    • 0031924998 scopus 로고    scopus 로고
    • Inactivation of human immunodeficiency virus type 1, hepatitis A virus, respiratory syncytial virus, vaccinia virus, herpes simplex virus type 1, and poliovirus type 2 by hydrogen peroxide gas plasma sterilization
    • Roberts C, Antonoplos P Inactivation of human immunodeficiency virus type 1, hepatitis A virus, respiratory syncytial virus, vaccinia virus, herpes simplex virus type 1, and poliovirus type 2 by hydrogen peroxide gas plasma sterilization. Am J Infect Control 1998, 26:94-101.
    • (1998) Am J Infect Control , vol.26 , pp. 94-101
    • Roberts, C.1    Antonoplos, P.2
  • 228
    • 0029559446 scopus 로고
    • Assessment of the efficacy of a low temperature hydrogen peroxide gas plasma sterilization system
    • Kyi MS, Holton J, Ridgway GL Assessment of the efficacy of a low temperature hydrogen peroxide gas plasma sterilization system. J Hosp Infect 1995, 31:275-284.
    • (1995) J Hosp Infect , vol.31 , pp. 275-284
    • Kyi, M.S.1    Holton, J.2    Ridgway, G.L.3
  • 229
    • 39749111823 scopus 로고    scopus 로고
    • Evaluation of low temperature hydrogen peroxide plasma sterilization
    • Borneff-Lipp M, Kaetzke A, Durr M Evaluation of low temperature hydrogen peroxide plasma sterilization. Zentralbl Steril 2008, 16:35-42.
    • (2008) Zentralbl Steril , vol.16 , pp. 35-42
    • Borneff-Lipp, M.1    Kaetzke, A.2    Durr, M.3
  • 230
    • 0031352886 scopus 로고    scopus 로고
    • Compatibility of medical devices and materials with low-temperature hydrogen peroxide gas plasma
    • Feldman LA, Hui HK Compatibility of medical devices and materials with low-temperature hydrogen peroxide gas plasma. Med Dev Diag Indust 1997, 19:57-62.
    • (1997) Med Dev Diag Indust , vol.19 , pp. 57-62
    • Feldman, L.A.1    Hui, H.K.2
  • 231
    • 0002520572 scopus 로고    scopus 로고
    • The new Sterrad 100S sterilization system: features and advantages
    • Jacobs PT, Smith D The new Sterrad 100S sterilization system: features and advantages. Zentralbl Steril 1998, 6:86-94.
    • (1998) Zentralbl Steril , vol.6 , pp. 86-94
    • Jacobs, P.T.1    Smith, D.2
  • 232
    • 0034061282 scopus 로고    scopus 로고
    • Infectious complications associated with gastrointestinal endoscopy
    • Schembre DB Infectious complications associated with gastrointestinal endoscopy. Gastrointest Endosc Clin North Am 2000, 10:215-232.
    • (2000) Gastrointest Endosc Clin North Am , vol.10 , pp. 215-232
    • Schembre, D.B.1
  • 233
    • 84856985143 scopus 로고    scopus 로고
    • Lessons learned from outbreaks and pseudo-outbreaks associated with bronchoscopy
    • Weber DJ, Rutala WA Lessons learned from outbreaks and pseudo-outbreaks associated with bronchoscopy. Infect Control Hosp Epidemiol 2012, 33:224-229.
    • (2012) Infect Control Hosp Epidemiol , vol.33 , pp. 224-229
    • Weber, D.J.1    Rutala, W.A.2
  • 234
    • 0042706408 scopus 로고    scopus 로고
    • Multi-society guideline for reprocessing flexible gastrointestinal endoscopes
    • Nelson DB, Jarvis WR, Rutala WA, et al. Multi-society guideline for reprocessing flexible gastrointestinal endoscopes. Infect Control Hosp Epidemiol 2003, 24:532-537.
    • (2003) Infect Control Hosp Epidemiol , vol.24 , pp. 532-537
    • Nelson, D.B.1    Jarvis, W.R.2    Rutala, W.A.3
  • 235
    • 76849091679 scopus 로고    scopus 로고
    • SGNA Standards of infection control in reprocessing of flexible gastrointestinal endoscopes
    • Society of Gastroenterology Nurses and Associates SGNA Standards of infection control in reprocessing of flexible gastrointestinal endoscopes. Gastroenterol Nurs 2010, 33:70-80.
    • (2010) Gastroenterol Nurs , vol.33 , pp. 70-80
  • 236
    • 77955449995 scopus 로고    scopus 로고
    • Endoscope reprocessing methods: a prospective study on the impact of human factors and automation
    • Ofstead CL, Wetzler HP, Snyder AK, et al. Endoscope reprocessing methods: a prospective study on the impact of human factors and automation. Gastroenterol Nurs 2010, 33:304-311.
    • (2010) Gastroenterol Nurs , vol.33 , pp. 304-311
    • Ofstead, C.L.1    Wetzler, H.P.2    Snyder, A.K.3
  • 237
    • 0031279659 scopus 로고    scopus 로고
    • Correction of deficiencies in flexible fiberoptic sigmoidoscope cleaning and disinfection technique in family practice and internal medicine offices
    • Jackson FW, Ball MD Correction of deficiencies in flexible fiberoptic sigmoidoscope cleaning and disinfection technique in family practice and internal medicine offices. Arch Fam Med 1997, 6:578-582.
    • (1997) Arch Fam Med , vol.6 , pp. 578-582
    • Jackson, F.W.1    Ball, M.D.2
  • 238
    • 0030727650 scopus 로고    scopus 로고
    • Italian National Survey of Digestive Endoscopy Disinfection Procedures
    • Orsi GB, Filocamo A, Di Stefano L, et al. Italian National Survey of Digestive Endoscopy Disinfection Procedures. Endoscopy 1997, 29:732-738.
    • (1997) Endoscopy , vol.29 , pp. 732-738
    • Orsi, G.B.1    Filocamo, A.2    Di Stefano, L.3
  • 239
    • 0030870860 scopus 로고    scopus 로고
    • An audit of bronchoscopy practice in the United Kingdom: a survey of adherence to national guidelines
    • Honeybourne D, Neumann CS An audit of bronchoscopy practice in the United Kingdom: a survey of adherence to national guidelines. Thorax 1997, 52:709-713.
    • (1997) Thorax , vol.52 , pp. 709-713
    • Honeybourne, D.1    Neumann, C.S.2
  • 240
    • 0037448354 scopus 로고    scopus 로고
    • An outbreak of Pseudomonas aeruginosa infections associated with flexible bronchoscopes
    • Srinivasan A, Wolfenden LL, Song X, et al. An outbreak of Pseudomonas aeruginosa infections associated with flexible bronchoscopes. N Engl J Med 2003, 348:221-227.
    • (2003) N Engl J Med , vol.348 , pp. 221-227
    • Srinivasan, A.1    Wolfenden, L.L.2    Song, X.3
  • 241
    • 0037883338 scopus 로고    scopus 로고
    • Outbreak of infection associated with bronchoscopes
    • Cetse JC, Vanhems P Outbreak of infection associated with bronchoscopes. N Engl J Med 2003, 348:2039-2040.
    • (2003) N Engl J Med , vol.348 , pp. 2039-2040
    • Cetse, J.C.1    Vanhems, P.2
  • 242
    • 33847700197 scopus 로고    scopus 로고
    • How to assess risk of disease transmission when there is a failure to follow recommended disinfection and sterilization principles
    • Rutala WA, Weber DJ How to assess risk of disease transmission when there is a failure to follow recommended disinfection and sterilization principles. Infect Control Hosp Epidemiol 2007, 28:519-524.
    • (2007) Infect Control Hosp Epidemiol , vol.28 , pp. 519-524
    • Rutala, W.A.1    Weber, D.J.2
  • 243
    • 0029283682 scopus 로고
    • FDA labeling requirements for disinfection of endoscopes: a counterpoint
    • Rutala WA, Weber DJ FDA labeling requirements for disinfection of endoscopes: a counterpoint. Infect Control Hosp Epidemiol 1995, 16:231-235.
    • (1995) Infect Control Hosp Epidemiol , vol.16 , pp. 231-235
    • Rutala, W.A.1    Weber, D.J.2
  • 244
    • 0033628708 scopus 로고    scopus 로고
    • Guidelines on cleaning and disinfection in GI endoscopy: update 1999. The European Society of Gastrointestinal Endoscopy
    • Kruse A, Rey JF Guidelines on cleaning and disinfection in GI endoscopy: update 1999. The European Society of Gastrointestinal Endoscopy. Endoscopy 2000, 32:77-80.
    • (2000) Endoscopy , vol.32 , pp. 77-80
    • Kruse, A.1    Rey, J.F.2
  • 245
    • 0031955527 scopus 로고    scopus 로고
    • Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a working party of the British Society of Gastroenterology Endoscope Committee
    • British Society of Gastroenterology Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a working party of the British Society of Gastroenterology Endoscope Committee. Gut 1998, 42:585-593.
    • (1998) Gut , vol.42 , pp. 585-593
  • 246
    • 18844464904 scopus 로고    scopus 로고
    • British Thoracic Society guidelines on diagnostic flexible bronchoscopy
    • British Thoracic Society British Thoracic Society guidelines on diagnostic flexible bronchoscopy. Thorax 2001, 56(suppl 1):1-21.
    • (2001) Thorax , vol.56 , pp. 1-21
  • 247
    • 0001204332 scopus 로고
    • Occupational exposure to bloodborne pathogens; final rule
    • Occupational Safety and Health Administration Occupational exposure to bloodborne pathogens; final rule. Fed Register 1991, 56:64003-64182.
    • (1991) Fed Register , vol.56 , pp. 64003-64182
  • 250
    • 0034930048 scopus 로고    scopus 로고
    • Inactivation of hepatitis B virus in plasma by hospital in-use chemical disinfectants assessed by a modified HepG2 cell culture
    • Payan C, Cottin J, Lemarie C, et al. Inactivation of hepatitis B virus in plasma by hospital in-use chemical disinfectants assessed by a modified HepG2 cell culture. J Hosp Infect 2001, 47:282-287.
    • (2001) J Hosp Infect , vol.47 , pp. 282-287
    • Payan, C.1    Cottin, J.2    Lemarie, C.3
  • 251
    • 0033605364 scopus 로고    scopus 로고
    • The looming threat of bioterrorism
    • Henderson DA The looming threat of bioterrorism. Science 1999, 283:1279-1282.
    • (1999) Science , vol.283 , pp. 1279-1282
    • Henderson, D.A.1
  • 252
    • 0034696740 scopus 로고    scopus 로고
    • Biological and chemical terrorism: strategic plan for preparedness and response
    • Centers for Disease Control and Prevention Biological and chemical terrorism: strategic plan for preparedness and response. MMWR Recomm Rep 2000, 49(RR-4):1-14.
    • (2000) MMWR Recomm Rep , vol.49 , Issue.RR 4 , pp. 1-14
  • 253
    • 0033395397 scopus 로고    scopus 로고
    • Infection control: the role of dis-infection and sterilization
    • Rutala WA, Weber DJ Infection control: the role of dis-infection and sterilization. J Hosp Infect 1999, 43(suppl):S43-S55.
    • (1999) J Hosp Infect , vol.43 , pp. S43-S55
    • Rutala, W.A.1    Weber, D.J.2
  • 254
    • 84859199893 scopus 로고    scopus 로고
    • Research to support the decontamination of surfaces and buildings contaminated with biothreat agents
    • Association for Professionals in Infection Control and Epidemiology, Washington, DC, W.A. Rutala (Ed.)
    • Ryan SP, Calfee MW, Wood JP, et al. Research to support the decontamination of surfaces and buildings contaminated with biothreat agents. Disinfection, Sterilization and Antisepsis: Principles, Practices, Current Issues, New Research, and New Technologies 2010, 260-306. Association for Professionals in Infection Control and Epidemiology, Washington, DC. W.A. Rutala (Ed.).
    • (2010) Disinfection, Sterilization and Antisepsis: Principles, Practices, Current Issues, New Research, and New Technologies , pp. 260-306
    • Ryan, S.P.1    Calfee, M.W.2    Wood, J.P.3
  • 255
    • 0031156868 scopus 로고    scopus 로고
    • Susceptibility of antibiotic-susceptible and antibiotic-resistant hospital bacteria to disinfectants
    • Rutala WA, Stiegel MM, Sarubbi FA, et al. Susceptibility of antibiotic-susceptible and antibiotic-resistant hospital bacteria to disinfectants. Infect Control Hosp Epidemiol 1997, 18:417-421.
    • (1997) Infect Control Hosp Epidemiol , vol.18 , pp. 417-421
    • Rutala, W.A.1    Stiegel, M.M.2    Sarubbi, F.A.3
  • 256
    • 33750565432 scopus 로고    scopus 로고
    • Use of germicides in the home and health care setting: is there a relationship between germicide use and antimicrobial resistance
    • Weber DJ, Rutala WA Use of germicides in the home and health care setting: is there a relationship between germicide use and antimicrobial resistance. Infect Control Hosp Epidemiol 2006, 27:1107-1119.
    • (2006) Infect Control Hosp Epidemiol , vol.27 , pp. 1107-1119
    • Weber, D.J.1    Rutala, W.A.2
  • 257
    • 75949105990 scopus 로고    scopus 로고
    • Guideline for disinfection and sterilization of prion-contaminated medical instruments
    • Rutala WA, Weber DJ Guideline for disinfection and sterilization of prion-contaminated medical instruments. Infect Control Hosp Epidemiol 2010, 31:107-117.
    • (2010) Infect Control Hosp Epidemiol , vol.31 , pp. 107-117
    • Rutala, W.A.1    Weber, D.J.2
  • 258
    • 0030576389 scopus 로고    scopus 로고
    • Surveillance for Creutzfeldt-Jakob disease-United States
    • Centers for Disease Control and Prevention Surveillance for Creutzfeldt-Jakob disease-United States. MMWR Morb Mortal Wkly Rep 1996, 45:665-668.
    • (1996) MMWR Morb Mortal Wkly Rep , vol.45 , pp. 665-668
  • 259
    • 78649930832 scopus 로고    scopus 로고
    • Disinfection and sterilization of prion-contaminated medical instruments
    • Belay ED, Schonberger LB, Brown P, et al. Disinfection and sterilization of prion-contaminated medical instruments. Infect Control Hosp Epidemiol 2010, 31:1304-1306.
    • (2010) Infect Control Hosp Epidemiol , vol.31 , pp. 1304-1306
    • Belay, E.D.1    Schonberger, L.B.2    Brown, P.3
  • 260
    • 78649973590 scopus 로고    scopus 로고
    • Disinfection and sterilization of prion-contaminated medical instruments: reply to Belay
    • Rutala WA, Weber DJ Disinfection and sterilization of prion-contaminated medical instruments: reply to Belay. Infect Control Hosp Epidemiol 2010, 31:1306-1307.
    • (2010) Infect Control Hosp Epidemiol , vol.31 , pp. 1306-1307
    • Rutala, W.A.1    Weber, D.J.2
  • 261
    • 79960191169 scopus 로고    scopus 로고
    • Adsorption of prion and tissue proteins to surgical stainless steel surfaces and the efficacy of decontamination following dry and wet storage conditions
    • Secker TJ, Herve R, Keevil CW Adsorption of prion and tissue proteins to surgical stainless steel surfaces and the efficacy of decontamination following dry and wet storage conditions. J Hosp Infect 2011, 78:251-255.
    • (2011) J Hosp Infect , vol.78 , pp. 251-255
    • Secker, T.J.1    Herve, R.2    Keevil, C.W.3
  • 263
    • 0035341334 scopus 로고    scopus 로고
    • Creutzfeldt-Jakob disease: recommendations for disinfection and sterilization
    • Rutala WA, Weber DJ Creutzfeldt-Jakob disease: recommendations for disinfection and sterilization. Clin Infect Dis 2001, 32:1348-1356.
    • (2001) Clin Infect Dis , vol.32 , pp. 1348-1356
    • Rutala, W.A.1    Weber, D.J.2
  • 264
    • 0033382236 scopus 로고    scopus 로고
    • Inactivation of prions by physical and chemical means
    • Taylor DM Inactivation of prions by physical and chemical means. J Hosp Infect 1999, 43(suppl):S69-S76.
    • (1999) J Hosp Infect , vol.43 , pp. S69-S76
    • Taylor, D.M.1
  • 265
    • 79958739691 scopus 로고    scopus 로고
    • The role played by contaminated surfaces in the transmission of nosocomial pathogens
    • Otter JA The role played by contaminated surfaces in the transmission of nosocomial pathogens. Infect Control Hosp Epidemiol 2011, 32:687-699.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 687-699
    • Otter, J.A.1
  • 266
    • 34249300080 scopus 로고    scopus 로고
    • Environmental contamination makes an important contribution to hospital infection
    • Boyce JM Environmental contamination makes an important contribution to hospital infection. J Hosp Infect 2007, 65:50-54.
    • (2007) J Hosp Infect , vol.65 , pp. 50-54
    • Boyce, J.M.1
  • 267
    • 77952994819 scopus 로고    scopus 로고
    • Role of hospital surfaces in the transmission of emerging health care-associated pathogens: norovirus, Clostridium difficile, and Acinetobacter species
    • Weber DJ, Rutala WA, Miller MB, et al. Role of hospital surfaces in the transmission of emerging health care-associated pathogens: norovirus, Clostridium difficile, and Acinetobacter species. Am J Infect Control 2010, 38:S25-S33.
    • (2010) Am J Infect Control , vol.38 , pp. S25-S33
    • Weber, D.J.1    Rutala, W.A.2    Miller, M.B.3
  • 268
    • 79960716757 scopus 로고    scopus 로고
    • Are room decontamination units needed to prevent transmission of environmental pathogens?
    • Rutala WA, Weber DJ Are room decontamination units needed to prevent transmission of environmental pathogens?. Infect Control Hosp Epidemiol 2011, 32:743-747.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 743-747
    • Rutala, W.A.1    Weber, D.J.2
  • 269
    • 78751670846 scopus 로고    scopus 로고
    • Contamination of hands with methicillin-resistant Staphylococcus aureus after contact with environmental surfaces and after contact with the skin of colonized patients
    • Stiefel U, Cadnum JL, Eckstein BC, et al. Contamination of hands with methicillin-resistant Staphylococcus aureus after contact with environmental surfaces and after contact with the skin of colonized patients. Infect Control Hosp Epidemiol 2011, 32:185-187.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 185-187
    • Stiefel, U.1    Cadnum, J.L.2    Eckstein, B.C.3
  • 270
    • 33749574575 scopus 로고    scopus 로고
    • Risk of acquiring antibiotic-resistant bacteria from prior room occupants
    • Huang SS, Datta R, Platt R Risk of acquiring antibiotic-resistant bacteria from prior room occupants. Arch Intern Med 2006, 166:1945-1951.
    • (2006) Arch Intern Med , vol.166 , pp. 1945-1951
    • Huang, S.S.1    Datta, R.2    Platt, R.3
  • 271
    • 79952411060 scopus 로고    scopus 로고
    • Evaluation of hospital room assignment and acquisition of Clostridium difficile infection
    • Shaughnessy MK, Micielli RL, DePestal DD, et al. Evaluation of hospital room assignment and acquisition of Clostridium difficile infection. Infect Control Hosp Epidemiol 2011, 32:201-206.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 201-206
    • Shaughnessy, M.K.1    Micielli, R.L.2    DePestal, D.D.3
  • 272
    • 39449113970 scopus 로고    scopus 로고
    • Identifying opportunities to enhance environmental cleaning in 23 acute care hospitals
    • Healthcare Environmental Hygiene Study Group
    • Carling PC, Parry MF, Von Beheren SM Identifying opportunities to enhance environmental cleaning in 23 acute care hospitals. Infect Control Hosp Epidemiol 2008, 29:1-7. Healthcare Environmental Hygiene Study Group.
    • (2008) Infect Control Hosp Epidemiol , vol.29 , pp. 1-7
    • Carling, P.C.1    Parry, M.F.2    Von Beheren, S.M.3
  • 273
    • 37749005066 scopus 로고    scopus 로고
    • Intensive care unit environmental cleaning: an evaluation in sixteen hospitals using a novel assessment tool
    • Carling PC, von Bheren S, Kim P, et al. Intensive care unit environmental cleaning: an evaluation in sixteen hospitals using a novel assessment tool. J Hosp Infect 2008, 68:39-44.
    • (2008) J Hosp Infect , vol.68 , pp. 39-44
    • Carling, P.C.1    von Bheren, S.2    Kim, P.3
  • 274
    • 80052021992 scopus 로고    scopus 로고
    • Cleanliness of portable medical equipment disinfected by nursing staff
    • Havill NL, Havill HL, Mangione E, et al. Cleanliness of portable medical equipment disinfected by nursing staff. Am J Infect Control 2011, 39:602-604.
    • (2011) Am J Infect Control , vol.39 , pp. 602-604
    • Havill, N.L.1    Havill, H.L.2    Mangione, E.3
  • 275
    • 58249086920 scopus 로고    scopus 로고
    • Intervention evaluation of environmental contamination by vancomycin-resistant enterococci: failure of personnel, product, or procedure?
    • Hota B, Blom DW, Lyle EA, et al. Intervention evaluation of environmental contamination by vancomycin-resistant enterococci: failure of personnel, product, or procedure?. J Hosp Infect 2009, 71:123-131.
    • (2009) J Hosp Infect , vol.71 , pp. 123-131
    • Hota, B.1    Blom, D.W.2    Lyle, E.A.3
  • 276
    • 47549098621 scopus 로고    scopus 로고
    • Impact of an environmental cleaning intervention on the presence of methicillin-resistant Staphylococcus aureus and vancomycin-resistant enterococci on surfaces in intensive care unit rooms
    • Goodman ER, Platt R, Bass R, et al. Impact of an environmental cleaning intervention on the presence of methicillin-resistant Staphylococcus aureus and vancomycin-resistant enterococci on surfaces in intensive care unit rooms. Infect Control Hosp Epidemiol 2008, 29:593-599.
    • (2008) Infect Control Hosp Epidemiol , vol.29 , pp. 593-599
    • Goodman, E.R.1    Platt, R.2    Bass, R.3
  • 277
    • 34447296689 scopus 로고    scopus 로고
    • Reduction of Clostridium difficile and vancomycin-resistant Enterococcus contamination of environmental surfaces after an intervention to improve cleaning methods
    • Eckstein BC, Adams DA, Eckstein EC, et al. Reduction of Clostridium difficile and vancomycin-resistant Enterococcus contamination of environmental surfaces after an intervention to improve cleaning methods. BMC Infect Dis 2007, 7:61.
    • (2007) BMC Infect Dis , vol.7 , pp. 61
    • Eckstein, B.C.1    Adams, D.A.2    Eckstein, E.C.3
  • 278
    • 79551711211 scopus 로고    scopus 로고
    • Sterilization, high-level disinfection, and environmental cleaning
    • Rutala WA, Weber DJ Sterilization, high-level disinfection, and environmental cleaning. Infect Dis Clin North Am 2011, 25:45-76.
    • (2011) Infect Dis Clin North Am , vol.25 , pp. 45-76
    • Rutala, W.A.1    Weber, D.J.2
  • 279
    • 77953010366 scopus 로고    scopus 로고
    • Applications of ultraviolet germicidal irradiation disinfection in health care facilities: effective adjunct, but not stand-alone technology
    • Memarzadeh F, Olmsted RN, Bartley JM Applications of ultraviolet germicidal irradiation disinfection in health care facilities: effective adjunct, but not stand-alone technology. Am J Infect Control 2010, 38:S13-S24.
    • (2010) Am J Infect Control , vol.38 , pp. S13-S24
    • Memarzadeh, F.1    Olmsted, R.N.2    Bartley, J.M.3
  • 281
    • 79960701617 scopus 로고    scopus 로고
    • Terminal decontamination of patient rooms using an automated mobile UV light unit
    • Boyce JM, Havill NL, Moore BA Terminal decontamination of patient rooms using an automated mobile UV light unit. Infect Control Hosp Epidemiol 2011, 32:743-747.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 743-747
    • Boyce, J.M.1    Havill, N.L.2    Moore, B.A.3
  • 282
    • 77955103443 scopus 로고    scopus 로고
    • Evaluation of an automated ultraviolet radiation device for decon-tamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms
    • Nerandzic MM, Cadnum JL, Pultz MJ, et al. Evaluation of an automated ultraviolet radiation device for decon-tamination of Clostridium difficile and other healthcare-associated pathogens in hospital rooms. BMC Infect Dis 2010, 10:197.
    • (2010) BMC Infect Dis , vol.10 , pp. 197
    • Nerandzic, M.M.1    Cadnum, J.L.2    Pultz, M.J.3
  • 283
    • 50949120269 scopus 로고    scopus 로고
    • Impact of hydrogen peroxide vapor room decontamination on Clostridium difficile environmental contamination and transmission in a healthcare setting
    • Boyce JM, Havill NL, Otter JA, et al. Impact of hydrogen peroxide vapor room decontamination on Clostridium difficile environmental contamination and transmission in a healthcare setting. Infect Control Hosp Epidemiol 2008, 29:723-729.
    • (2008) Infect Control Hosp Epidemiol , vol.29 , pp. 723-729
    • Boyce, J.M.1    Havill, N.L.2    Otter, J.A.3
  • 284
    • 2342485984 scopus 로고    scopus 로고
    • Tackling contamination of the hospital environment by methicillin-resistant Staphylococcus aureus (MRSA): a comparison between conventional terminal cleaning and hydrogen peroxide vapour decontamination
    • French GL, Otter JA, Shannon KP, et al. Tackling contamination of the hospital environment by methicillin-resistant Staphylococcus aureus (MRSA): a comparison between conventional terminal cleaning and hydrogen peroxide vapour decontamination. J Hosp Infect 2004, 57:31-37.
    • (2004) J Hosp Infect , vol.57 , pp. 31-37
    • French, G.L.1    Otter, J.A.2    Shannon, K.P.3
  • 285
    • 48749123087 scopus 로고    scopus 로고
    • Environmental methicillin-resistant Staphylococcus aureus (MRSA) disinfection using dry-mist-generated hydrogen peroxide
    • Bartels MD, Kristofferson K, Slotsbjerg T, et al. Environmental methicillin-resistant Staphylococcus aureus (MRSA) disinfection using dry-mist-generated hydrogen peroxide. J Hosp Infect 2008, 70:35-41.
    • (2008) J Hosp Infect , vol.70 , pp. 35-41
    • Bartels, M.D.1    Kristofferson, K.2    Slotsbjerg, T.3
  • 286
    • 33947260670 scopus 로고    scopus 로고
    • Use of hydrogen peroxide vapor for deactivation of Mycobacterium tuberculosis in a biological safety cabinet and a room
    • Hall L, Otter JA, Chewins J, et al. Use of hydrogen peroxide vapor for deactivation of Mycobacterium tuberculosis in a biological safety cabinet and a room. J Clin Microbiol 2007, 45:810-815.
    • (2007) J Clin Microbiol , vol.45 , pp. 810-815
    • Hall, L.1    Otter, J.A.2    Chewins, J.3
  • 287
    • 34547668867 scopus 로고    scopus 로고
    • Rapid recontamination with MRSA of the environment of an intensive care unit after decontamination with hydrogen peroxide vapour
    • Hardy KJ, Gossain S, Henderson N, et al. Rapid recontamination with MRSA of the environment of an intensive care unit after decontamination with hydrogen peroxide vapour. J Hosp Infect 2007, 66:360-368.
    • (2007) J Hosp Infect , vol.66 , pp. 360-368
    • Hardy, K.J.1    Gossain, S.2    Henderson, N.3
  • 288
    • 11844302901 scopus 로고    scopus 로고
    • Evaluation of hydrogen peroxide vapour as a method for the decontamination of surfaces contaminated with Clostridium botulinum spores
    • Johnston MD, Lawson S, Otter JA Evaluation of hydrogen peroxide vapour as a method for the decontamination of surfaces contaminated with Clostridium botulinum spores. J Microbiol Methods 2005, 60:403-411.
    • (2005) J Microbiol Methods , vol.60 , pp. 403-411
    • Johnston, M.D.1    Lawson, S.2    Otter, J.A.3
  • 289
    • 0030766486 scopus 로고    scopus 로고
    • Efficacy of vaporized hydrogen peroxide against exotic animal viruses
    • Heckert RA, Best M, Jordan LT, et al. Efficacy of vaporized hydrogen peroxide against exotic animal viruses. Appl Environ Microbiol 1997, 63:3916-3918.
    • (1997) Appl Environ Microbiol , vol.63 , pp. 3916-3918
    • Heckert, R.A.1    Best, M.2    Jordan, L.T.3
  • 290
    • 0025014713 scopus 로고
    • Vapor-phase hydrogen peroxide as a surface decontaminant and sterilant
    • Klapes NA, Vesley D Vapor-phase hydrogen peroxide as a surface decontaminant and sterilant. Appl Environ Microbiol 1990, 56:503-506.
    • (1990) Appl Environ Microbiol , vol.56 , pp. 503-506
    • Klapes, N.A.1    Vesley, D.2
  • 291
    • 13844319541 scopus 로고    scopus 로고
    • Use of hydrogen peroxide vapour for environmental control during a Serratia outbreak in a neonatal intensive care unit
    • Bates CJ, Pearse R Use of hydrogen peroxide vapour for environmental control during a Serratia outbreak in a neonatal intensive care unit. J Hosp Infect 2005, 61:364-366.
    • (2005) J Hosp Infect , vol.61 , pp. 364-366
    • Bates, C.J.1    Pearse, R.2
  • 292
    • 50849110800 scopus 로고    scopus 로고
    • Activity of a dry mist hydrogen peroxide system against environmental Clostridium difficile contamination in elderly care wards
    • Shapey S, Machin K, Levi K, et al. Activity of a dry mist hydrogen peroxide system against environmental Clostridium difficile contamination in elderly care wards. J Hosp Infect 2008, 70:136-141.
    • (2008) J Hosp Infect , vol.70 , pp. 136-141
    • Shapey, S.1    Machin, K.2    Levi, K.3
  • 293
    • 0024462026 scopus 로고
    • Management of infectious waste by United States hospitals
    • Rutala WA, Odette RL, Samsa GP Management of infectious waste by United States hospitals. JAMA 1989, 262:1635-1640.
    • (1989) JAMA , vol.262 , pp. 1635-1640
    • Rutala, W.A.1    Odette, R.L.2    Samsa, G.P.3
  • 294
    • 0020948631 scopus 로고
    • Management of infectious waste from hospitals
    • Rutala WA, Sarubbi FA Management of infectious waste from hospitals. Infect Control 1983, 4:198-204.
    • (1983) Infect Control , vol.4 , pp. 198-204
    • Rutala, W.A.1    Sarubbi, F.A.2
  • 296
    • 0012841664 scopus 로고
    • U.S. Environmental Protection Agency, Washington, DC
    • Environmental Protection Agency EPA Guide for Infectious Waste Management 1986, U.S. Environmental Protection Agency, Washington, DC.
    • (1986) EPA Guide for Infectious Waste Management
  • 297
    • 0344771784 scopus 로고
    • Government Printing Office, Washington, DC
    • Office of Technology Assessment (OTA-0-459 Finding the Rx for Managing Medical Wastes 1990, Government Printing Office, Washington, DC.
    • (1990) Finding the Rx for Managing Medical Wastes
  • 298
    • 0348102636 scopus 로고
    • Standards for the tracking and management of medical waste; interim final rule and request for comments
    • Environmental Protection Agency Standards for the tracking and management of medical waste; interim final rule and request for comments. Fed Register 1989, 54:12326-12395.
    • (1989) Fed Register , vol.54 , pp. 12326-12395
  • 299
    • 0025887357 scopus 로고
    • Infectious waste: mismatch between science and policy
    • Rutala WA, Weber DJ Infectious waste: mismatch between science and policy. N Engl J Med 1991, 325:578-582.
    • (1991) N Engl J Med , vol.325 , pp. 578-582
    • Rutala, W.A.1    Weber, D.J.2
  • 301
    • 0026436560 scopus 로고
    • SHEA position paper: Medical waste
    • Society for Hospital Epidemiology of America
    • Rutala WA, Mayhall CG SHEA position paper: Medical waste. Infect Control Hosp Epidemiol 1992, 13:38-48. Society for Hospital Epidemiology of America.
    • (1992) Infect Control Hosp Epidemiol , vol.13 , pp. 38-48
    • Rutala, W.A.1    Mayhall, C.G.2
  • 302
    • 84944613637 scopus 로고
    • Infectious substances: final rule
    • U.S.Department of Transportation Infectious substances: final rule. Fed Register 1995, 60:48779-48787.
    • (1995) Fed Register , vol.60 , pp. 48779-48787
  • 303
    • 0009519451 scopus 로고    scopus 로고
    • Selection and use of disinfectants in healthcare
    • Lippincott Williams & Wilkins, Philadelphia, C.G. Mayhall (Ed.), 2nd ed.
    • Rutala WA Selection and use of disinfectants in healthcare. Hospital Epidemiology and Infection Control 1999, 1161-1187. Lippincott Williams & Wilkins, Philadelphia. 2nd ed. C.G. Mayhall (Ed.).
    • (1999) Hospital Epidemiology and Infection Control , pp. 1161-1187
    • Rutala, W.A.1
  • 304
    • 79956014856 scopus 로고    scopus 로고
    • Sterilization and disinfection
    • Wolters Kluwer/Lippincott Williams & Wilkins, Philadelphia, W.R. Jarvis (Ed.), 5th ed.
    • Rutala WA, Weber DJ Sterilization and disinfection. Bennett & Brachman's Hospital Infections 2007, 303-318. Wolters Kluwer/Lippincott Williams & Wilkins, Philadelphia. 5th ed. W.R. Jarvis (Ed.).
    • (2007) Bennett & Brachman's Hospital Infections , pp. 303-318
    • Rutala, W.A.1    Weber, D.J.2
  • 306
    • 84924381421 scopus 로고    scopus 로고
    • Selection and use of disinfectants in healthcare
    • Wolters Kluwer/Lippincott Williams & Wilkins, Philadelphia, C.G. Mayhall (Ed.), 4th ed.
    • Rutala WA, Weber DJ Selection and use of disinfectants in healthcare. Hospital Epidemiology and Infection Control 2012, Wolters Kluwer/Lippincott Williams & Wilkins, Philadelphia. 4th ed. C.G. Mayhall (Ed.).
    • (2012) Hospital Epidemiology and Infection Control
    • Rutala, W.A.1    Weber, D.J.2
  • 308
    • 84973890054 scopus 로고    scopus 로고
    • Disinfection and sterilization in health-care facilities
    • Wolters Kluwer/Lippincott Williams & Wilkins, Philadelphia, W.R. Jarvis (Ed.), 6th ed.
    • Rutala WA, Weber DJ Disinfection and sterilization in health-care facilities. Bennett and Brachman's Hospital Infections 2013, Wolters Kluwer/Lippincott Williams & Wilkins, Philadelphia. 6th ed. W.R. Jarvis (Ed.).
    • (2013) Bennett and Brachman's Hospital Infections
    • Rutala, W.A.1    Weber, D.J.2
  • 310
    • 0030074687 scopus 로고    scopus 로고
    • Comparison of ion plasma, vaporized hydrogen peroxide and 100% ethylene oxide sterilizers to the 12/88 ethylene oxide gas sterilizer
    • Alfa MJ, DeGagne P, Olson N, et al. Comparison of ion plasma, vaporized hydrogen peroxide and 100% ethylene oxide sterilizers to the 12/88 ethylene oxide gas sterilizer. Infect Control Hosp Epidemiol 1996, 17:92-100.
    • (1996) Infect Control Hosp Epidemiol , vol.17 , pp. 92-100
    • Alfa, M.J.1    DeGagne, P.2    Olson, N.3
  • 311
    • 84876912735 scopus 로고    scopus 로고
    • New developments in reprocessing semicritical devices
    • Rutala WA, Weber DJ New developments in reprocessing semicritical devices. Am J Infect Control 2013, 41(5 suppl):S60-S66.
    • (2013) Am J Infect Control , vol.41 , Issue.5 , pp. S60-S66
    • Rutala, W.A.1    Weber, D.J.2
  • 312
    • 79957963760 scopus 로고    scopus 로고
    • Multisociety guideline on reprocessing flexible GI endoscopes: 2011
    • Petersen BT, Chennat J, Cohen J, et al. Multisociety guideline on reprocessing flexible GI endoscopes: 2011. Infect Control Hosp Epidemiol 2011, 32:527-537.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 527-537
    • Petersen, B.T.1    Chennat, J.2    Cohen, J.3
  • 313
    • 3042756428 scopus 로고    scopus 로고
    • Guidelines for environmental infection control in health-care facilities, 2003
    • Centers for Disease Control and Prevention Guidelines for environmental infection control in health-care facilities, 2003. MMWR Recomm Rep 2003, 52(RR-10):1-44.
    • (2003) MMWR Recomm Rep , vol.52 , Issue.RR 10 , pp. 1-44
  • 314
    • 0033630769 scopus 로고    scopus 로고
    • Antimicrobial activity of home disinfectants and natural products against potential human pathogens
    • Rutala WA, Barbee SL, Aguiar NC, et al. Antimicrobial activity of home disinfectants and natural products against potential human pathogens. Infect Control Hosp Epidemiol 2000, 21:33-38.
    • (2000) Infect Control Hosp Epidemiol , vol.21 , pp. 33-38
    • Rutala, W.A.1    Barbee, S.L.2    Aguiar, N.C.3
  • 315
    • 0025182439 scopus 로고
    • Efficacies of selected disinfectants against Mycobacterium tuberculosis
    • Best M, Sattar SA, Springthorpe VS, et al. Efficacies of selected disinfectants against Mycobacterium tuberculosis. J Clin Microbiol 1990, 28:2234-2239.
    • (1990) J Clin Microbiol , vol.28 , pp. 2234-2239
    • Best, M.1    Sattar, S.A.2    Springthorpe, V.S.3
  • 316
    • 0033254252 scopus 로고    scopus 로고
    • The effect of blood on the antiviral activity of sodium hypochlorite, a phenolic, and a quaternary ammonium compound
    • Weber DJ, Barbee SL, Sobsey MD, et al. The effect of blood on the antiviral activity of sodium hypochlorite, a phenolic, and a quaternary ammonium compound. Infect Control Hosp Epidemiol 1999, 20:821-827.
    • (1999) Infect Control Hosp Epidemiol , vol.20 , pp. 821-827
    • Weber, D.J.1    Barbee, S.L.2    Sobsey, M.D.3
  • 317
    • 84867438406 scopus 로고    scopus 로고
    • Efficacy of improved hydrogen peroxide against important healthcare-associated pathogens
    • Rutala WA, Gergen MF, Weber DJ Efficacy of improved hydrogen peroxide against important healthcare-associated pathogens. Infect Control Hosp Epidemiol 2012, 33:1159-1161.
    • (2012) Infect Control Hosp Epidemiol , vol.33 , pp. 1159-1161
    • Rutala, W.A.1    Gergen, M.F.2    Weber, D.J.3
  • 318
    • 54949127200 scopus 로고    scopus 로고
    • Improving cleaning of the environment surrounding patients in 36 acute care hospitals
    • Carling PC, Parry MF, Rupp ME, et al. Improving cleaning of the environment surrounding patients in 36 acute care hospitals. Infect Control Hosp Epidemiol 2008, 29:1035-1041.
    • (2008) Infect Control Hosp Epidemiol , vol.29 , pp. 1035-1041
    • Carling, P.C.1    Parry, M.F.2    Rupp, M.E.3
  • 319
    • 33645798070 scopus 로고    scopus 로고
    • Efficacy of hospital germicides against adenovirus 8, a common cause of epidemic keratoconjunctivitis in health care facilities
    • Rutala WA, Peacock JE, Gergen MF, et al. Efficacy of hospital germicides against adenovirus 8, a common cause of epidemic keratoconjunctivitis in health care facilities. Antimicrob Agents Chemother 2006, 50:1419-1424.
    • (2006) Antimicrob Agents Chemother , vol.50 , pp. 1419-1424
    • Rutala, W.A.1    Peacock, J.E.2    Gergen, M.F.3
  • 320
    • 0030723030 scopus 로고    scopus 로고
    • Uses of inorganic hypochlorite (bleach) in health-care facilities
    • Rutala WA, Weber DJ Uses of inorganic hypochlorite (bleach) in health-care facilities. Clin Microbiol Rev 1997, 10:597-610.
    • (1997) Clin Microbiol Rev , vol.10 , pp. 597-610
    • Rutala, W.A.1    Weber, D.J.2
  • 322
    • 23044492188 scopus 로고    scopus 로고
    • Activity of selected oxidizing microbicides against spores of Clostridium difficile: relevance to environmental control
    • Perez J, Springthorpe S, Sattar SA Activity of selected oxidizing microbicides against spores of Clostridium difficile: relevance to environmental control. Am J Infect Control 2005, 33:320-325.
    • (2005) Am J Infect Control , vol.33 , pp. 320-325
    • Perez, J.1    Springthorpe, S.2    Sattar, S.A.3
  • 325
    • 0027444731 scopus 로고
    • Bactericidal, virucidal, and mycobactericidal activities of reused alkaline glutaraldehyde in an endoscopy unit
    • Mbithi JN, Springthorpe VS, Sattar SA, et al. Bactericidal, virucidal, and mycobactericidal activities of reused alkaline glutaraldehyde in an endoscopy unit. J Clin Microbiol 1993, 31:2988-2995.
    • (1993) J Clin Microbiol , vol.31 , pp. 2988-2995
    • Mbithi, J.N.1    Springthorpe, V.S.2    Sattar, S.A.3
  • 327
    • 0026095191 scopus 로고
    • Inactivation of Mycobacterium tuberculosis and Mycobacterium bovis by 14 hospital disinfectants
    • Rutala WA, Cole EC, Wannamaker NS, et al. Inactivation of Mycobacterium tuberculosis and Mycobacterium bovis by 14 hospital disinfectants. Am J Med 1991, 91:267S-271S.
    • (1991) Am J Med , vol.91 , pp. 267S-271S
    • Rutala, W.A.1    Cole, E.C.2    Wannamaker, N.S.3
  • 329
    • 40949107723 scopus 로고    scopus 로고
    • Virucidal activity of ortho-phthalaldehyde solutions against hepatitis B and C viruses
    • Roberts CG, Chan-Myers HB, Favero MS Virucidal activity of ortho-phthalaldehyde solutions against hepatitis B and C viruses. Am J Infect Control 2008, 36:223-226.
    • (2008) Am J Infect Control , vol.36 , pp. 223-226
    • Roberts, C.G.1    Chan-Myers, H.B.2    Favero, M.S.3
  • 330
    • 84944536982 scopus 로고    scopus 로고
    • U.S.Food and Drug Administration Steris System 1E Liquid Chemical Sterilant Available at. http://wwwfdagov/MedicalDevices/ProductsandMedicalProcedures/DeviceApprovalsandClearances/Recently-ApprovedDevices/ucm207489htm.
    • Steris System 1E Liquid Chemical Sterilant
  • 331
    • 0346554265 scopus 로고    scopus 로고
    • New low temperature sterilization technologies: microbicidal activity and clinical efficacy
    • Polyscience Publications, Champlain, NY, W.A. Rutala (Ed.)
    • Alfa MJ, Olson N, Degagne P, et al. New low temperature sterilization technologies: microbicidal activity and clinical efficacy. Disinfection, Sterilization, and Antisepsis in Healthcare 1998, 67-78. Polyscience Publications, Champlain, NY. W.A. Rutala (Ed.).
    • (1998) Disinfection, Sterilization, and Antisepsis in Healthcare , pp. 67-78
    • Alfa, M.J.1    Olson, N.2    Degagne, P.3
  • 332
    • 0023463444 scopus 로고
    • Ineffectiveness of hospital disinfectants against bacteria: a collaborative study
    • Rutala WA, Cole EC Ineffectiveness of hospital disinfectants against bacteria: a collaborative study. Infect Control 1987, 8:501-506.
    • (1987) Infect Control , vol.8 , pp. 501-506
    • Rutala, W.A.1    Cole, E.C.2
  • 333
    • 21644468535 scopus 로고    scopus 로고
    • Sterility assurance: concepts for patient safety
    • Association for Professional in Infection Control and Epidemiology, Washington, DC, W.A. Rutala (Ed.)
    • Favero MS Sterility assurance: concepts for patient safety. Disinfection, Sterilization and Antisepsis: Principles and Practices in Healthcare Facilities 2001, 110-119. Association for Professional in Infection Control and Epidemiology, Washington, DC. W.A. Rutala (Ed.).
    • (2001) Disinfection, Sterilization and Antisepsis: Principles and Practices in Healthcare Facilities , pp. 110-119
    • Favero, M.S.1
  • 334
    • 84876919548 scopus 로고    scopus 로고
    • Immediate use steam sterilization: moving beyond current policy
    • Seavey R Immediate use steam sterilization: moving beyond current policy. Am J Infect Control 2013, 41(5 suppl):S46-S48.
    • (2013) Am J Infect Control , vol.41 , Issue.5 , pp. S46-S48
    • Seavey, R.1
  • 335
    • 84876891985 scopus 로고    scopus 로고
    • Association for the Advancement of Medical Instrumentation, Accreditation Association for Ambulatory Health Care, Association of Perioperative Registered Nurses, et al. Immediate-Use Steam Sterilization Available at. http://www.aami.org/publications/standards/ST79_Immediate_Use_Statement.pdf.
    • Immediate-Use Steam Sterilization
  • 337
    • 33847700197 scopus 로고    scopus 로고
    • How to assess risk of disease transmission when there is a failure to follow recommended disinfection and sterilization principles
    • Rutala WA, Weber DJ How to assess risk of disease transmission when there is a failure to follow recommended disinfection and sterilization principles. Infect Control Hosp Epidemiol 2007, 28:519-524.
    • (2007) Infect Control Hosp Epidemiol , vol.28 , pp. 519-524
    • Rutala, W.A.1    Weber, D.J.2
  • 338
    • 0029283682 scopus 로고
    • FDA labeling requirements for disinfection of endoscopes: a counterpoint
    • Rutala WA, Weber DJ FDA labeling requirements for disinfection of endoscopes: a counterpoint. Infect Control Hosp Epidemiol 1995, 16:231-235.
    • (1995) Infect Control Hosp Epidemiol , vol.16 , pp. 231-235
    • Rutala, W.A.1    Weber, D.J.2
  • 339
    • 0001204332 scopus 로고
    • Occupational exposure to bloodborne pathogens; final rule
    • Occupational Safety and Health Administration Occupational exposure to bloodborne pathogens; final rule. Fed Register 1991, 56:64003-64182.
    • (1991) Fed Register , vol.56 , pp. 64003-64182
  • 340
    • 0031156868 scopus 로고    scopus 로고
    • Susceptibility of antibiotic-susceptible and antibiotic-resistant hospital bacteria to disinfectants
    • Rutala WA, Stiegel MM, Sarubbi FA, et al. Susceptibility of antibiotic-susceptible and antibiotic-resistant hospital bacteria to disinfectants. Infect Control Hosp Epidemiol 1997, 18:417-421.
    • (1997) Infect Control Hosp Epidemiol , vol.18 , pp. 417-421
    • Rutala, W.A.1    Stiegel, M.M.2    Sarubbi, F.A.3
  • 341
    • 33750565432 scopus 로고    scopus 로고
    • Use of germicides in the home and health care setting: is there a relationship between germicide use and antimicrobial resistance
    • Weber DJ, Rutala WA Use of germicides in the home and health care setting: is there a relationship between germicide use and antimicrobial resistance. Infect Control Hosp Epidemiol 2006, 27:1107-1119.
    • (2006) Infect Control Hosp Epidemiol , vol.27 , pp. 1107-1119
    • Weber, D.J.1    Rutala, W.A.2
  • 342
    • 75949105990 scopus 로고    scopus 로고
    • Guideline for disinfection and sterilization of prion-contaminated medical instruments
    • Rutala WA, Weber DJ Guideline for disinfection and sterilization of prion-contaminated medical instruments. Infect Control Hosp Epidemiol 2010, 31:107-117.
    • (2010) Infect Control Hosp Epidemiol , vol.31 , pp. 107-117
    • Rutala, W.A.1    Weber, D.J.2
  • 343
    • 78649930832 scopus 로고    scopus 로고
    • Disinfection and sterilization of prion-contaminated medical instruments
    • Belay ED, Schonberger LB, Brown P, et al. Disinfection and sterilization of prion-contaminated medical instruments. Infect Control Hosp Epidemiol 2010, 31:1304-1306.
    • (2010) Infect Control Hosp Epidemiol , vol.31 , pp. 1304-1306
    • Belay, E.D.1    Schonberger, L.B.2    Brown, P.3
  • 344
    • 78649973590 scopus 로고    scopus 로고
    • Disinfection and sterilization of prion-contaminated medical instruments: reply to Belay
    • Rutala WA, Weber DJ Disinfection and sterilization of prion-contaminated medical instruments: reply to Belay. Infect Control Hosp Epidemiol 2010, 31:1306-1307.
    • (2010) Infect Control Hosp Epidemiol , vol.31 , pp. 1306-1307
    • Rutala, W.A.1    Weber, D.J.2
  • 346
    • 79958739691 scopus 로고    scopus 로고
    • The role played by contaminated surfaces in the transmission of nosocomial pathogens
    • Otter JA The role played by contaminated surfaces in the transmission of nosocomial pathogens. Infect Control Hosp Epidemiol 2011, 32:687-699.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 687-699
    • Otter, J.A.1
  • 347
    • 34249300080 scopus 로고    scopus 로고
    • Environmental contamination makes an important contribution to hospital infection
    • Boyce JM Environmental contamination makes an important contribution to hospital infection. J Hosp Infect 2007, 65:50-54.
    • (2007) J Hosp Infect , vol.65 , pp. 50-54
    • Boyce, J.M.1
  • 348
    • 77952994819 scopus 로고    scopus 로고
    • Role of hospital surfaces in the transmission of emerging health care-associated pathogens: norovirus, Clostridium difficile, and Acinetobacter species
    • Weber DJ, Rutala WA, Miller MB, et al. Role of hospital surfaces in the transmission of emerging health care-associated pathogens: norovirus, Clostridium difficile, and Acinetobacter species. Am J Infect Control 2010, 38:S25-S33.
    • (2010) Am J Infect Control , vol.38 , pp. S25-S33
    • Weber, D.J.1    Rutala, W.A.2    Miller, M.B.3
  • 349
    • 79960716757 scopus 로고    scopus 로고
    • Are room decontamination units needed to prevent transmission of environmental pathogens?
    • Rutala WA, Weber DJ Are room decontamination units needed to prevent transmission of environmental pathogens?. Infect Control Hosp Epidemiol 2011, 32:743-747.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 743-747
    • Rutala, W.A.1    Weber, D.J.2
  • 350
    • 33749574575 scopus 로고    scopus 로고
    • Risk of acquiring antibiotic-resistant bacteria from prior room occupants
    • Huang SS, Datta R, Platt R Risk of acquiring antibiotic-resistant bacteria from prior room occupants. Arch Intern Med 2006, 166:1945-1951.
    • (2006) Arch Intern Med , vol.166 , pp. 1945-1951
    • Huang, S.S.1    Datta, R.2    Platt, R.3
  • 351
    • 79952411060 scopus 로고    scopus 로고
    • Evaluation of hospital room assignment and acquisition of Clostridium difficile infection
    • Shaughnessy MK, Micielli RL, DePestal DD, et al. Evaluation of hospital room assignment and acquisition of Clostridium difficile infection. Infect Control Hosp Epidemiol 2011, 32:201-206.
    • (2011) Infect Control Hosp Epidemiol , vol.32 , pp. 201-206
    • Shaughnessy, M.K.1    Micielli, R.L.2    DePestal, D.D.3
  • 352
    • 39449113970 scopus 로고    scopus 로고
    • Identifying opportunities to enhance environmental cleaning in 23 acute care hospitals
    • Healthcare Environmental Hygiene Study Group
    • Carling PC, Parry MF, Von Beheren SM Identifying opportunities to enhance environmental cleaning in 23 acute care hospitals. Infect Control Hosp Epidemiol 2008, 29:1-7. Healthcare Environmental Hygiene Study Group.
    • (2008) Infect Control Hosp Epidemiol , vol.29 , pp. 1-7
    • Carling, P.C.1    Parry, M.F.2    Von Beheren, S.M.3
  • 354
    • 50949120269 scopus 로고    scopus 로고
    • Impact of hydrogen peroxide vapor room decontamination on Clostridium difficile environmental contamination and transmission in a healthcare setting
    • Boyce JM, Havill NL, Otter JA, et al. Impact of hydrogen peroxide vapor room decontamination on Clostridium difficile environmental contamination and transmission in a healthcare setting. Infect Control Hosp Epidemiol 2008, 29:723-729.
    • (2008) Infect Control Hosp Epidemiol , vol.29 , pp. 723-729
    • Boyce, J.M.1    Havill, N.L.2    Otter, J.A.3
  • 355
    • 0024462026 scopus 로고
    • Management of infectious waste by United States hospitals
    • Rutala WA, Odette RL, Samsa GP Management of infectious waste by United States hospitals. JAMA 1989, 262:1635-1640.
    • (1989) JAMA , vol.262 , pp. 1635-1640
    • Rutala, W.A.1    Odette, R.L.2    Samsa, G.P.3
  • 356
    • 0020948631 scopus 로고
    • Management of infectious waste from hospitals
    • Rutala WA, Sarubbi FA Management of infectious waste from hospitals. Infect Control 1983, 4:198-204.
    • (1983) Infect Control , vol.4 , pp. 198-204
    • Rutala, W.A.1    Sarubbi, F.A.2
  • 357
    • 0025887357 scopus 로고
    • Infectious waste: mismatch between science and policy
    • Rutala WA, Weber DJ Infectious waste: mismatch between science and policy. N Engl J Med 1991, 325:578-582.
    • (1991) N Engl J Med , vol.325 , pp. 578-582
    • Rutala, W.A.1    Weber, D.J.2
  • 358
    • 0026436560 scopus 로고
    • SHEA position paper: Medical waste
    • Society for Hospital Epidemiology of America
    • Rutala WA, Mayhall CG SHEA position paper: Medical waste. Infect Control Hosp Epidemiol 1992, 13:38-48. Society for Hospital Epidemiology of America.
    • (1992) Infect Control Hosp Epidemiol , vol.13 , pp. 38-48
    • Rutala, W.A.1    Mayhall, C.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.