메뉴 건너뛰기




Volumn 26, Issue 1, 1992, Pages 7-25

Hypersensitivity reactions to titanium: Diagnosis and management

Author keywords

[No Author keywords available]

Indexed keywords

ALLOY; ALUMINUM; ATROPINE; BERYLLIUM; CADMIUM; CHROMIUM; COBALT; COPPER; CORTICOSTEROID; COSMETIC; HAFNIUM; IRON; MANGANESE; MOLYBDENUM; NICKEL; OXINIUM; PALLADIUM; PARYLENE; POLITEF; POLYMER; SILICONE; STRENGTH TO WEIGHT RATIO; SUNSCREEN; TITANIUM; TRACE ELEMENT; UNCLASSIFIED DRUG; VANADIUM; ZIRCONIUM OXIDE;

EID: 84944163170     PISSN: 01051873     EISSN: 16000536     Source Type: Journal    
DOI: 10.1097/DER.0000000000000091     Document Type: Article
Times cited : (47)

References (134)
  • 3
    • 84949128744 scopus 로고
    • The titanium alloys
    • Donachie MJ Jr. 2nd ed. Materials Park, OH: ASM International
    • Donachie MJ Jr. The titanium alloys. In: Donachie MJ Jr. Titanium: A Technical Guide. 2nd ed. Materials Park, OH: ASM International; 1988:5-11.
    • (1988) Titanium: A Technical Guide , pp. 5-11
    • Donachie, M.J.1
  • 4
    • 84949118328 scopus 로고    scopus 로고
    • Materials classification
    • Oshida Y, ed. 2nd ed. Oxford, UK: Elsevier Science Ltd
    • Oshida Y. Materials classification. In: Oshida Y, ed. Bioscience and Bioengineering of Titanium Materials. 2nd ed. Oxford, UK: Elsevier Science Ltd; 2013:9-34.
    • (2013) Bioscience and Bioengineering of Titanium Materials , pp. 9-34
    • Oshida, Y.1
  • 5
    • 80052099864 scopus 로고    scopus 로고
    • Titanium allergy or not? "Impurity" of titanium implant materials
    • Harloff T, Hönle W, Holzwarth U, et al. Titanium allergy or not? "Impurity" of titanium implant materials. Health 2010;2(4):306-310.
    • (2010) Health , vol.2 , Issue.4 , pp. 306-310
    • Harloff, T.1    Hönle, W.2    Holzwarth, U.3
  • 6
    • 84876288720 scopus 로고    scopus 로고
    • Hypersensitivity to titanium: A less explored area of research
    • Vijayaraghavan V, Sabane AV, Tejas K. Hypersensitivity to titanium: a less explored area of research. J Indian Prosthodont Soc 2012;12(4):201-207.
    • (2012) J Indian Prosthodont Soc , vol.12 , Issue.4 , pp. 201-207
    • Vijayaraghavan, V.1    Sabane, A.V.2    Tejas, K.3
  • 7
    • 0034887654 scopus 로고    scopus 로고
    • Metal sensitivity in patients with orthopedic implants
    • Hallab N. Metal sensitivity in patients with orthopedic implants. J Clin Rheumatol 2001;7(4):215-218.
    • (2001) J Clin Rheumatol , vol.7 , Issue.4 , pp. 215-218
    • Hallab, N.1
  • 8
    • 33646358485 scopus 로고    scopus 로고
    • Sensitivity to implant materials in patients undergoing total hip replacement
    • Granchi D, Cenni E, Trisolino G, et al. Sensitivity to implant materials in patients undergoing total hip replacement. J Biomed Mater Res Part B: Appl Biomater 2006;77B:257-264.
    • (2006) J Biomed Mater Res Part B: Appl Biomater , vol.77 B , pp. 257-264
    • Granchi, D.1    Cenni, E.2    Trisolino, G.3
  • 9
    • 84876214556 scopus 로고    scopus 로고
    • North American Contact Dermatitis Group patch test results: 2009 to 2010
    • Warshaw EM, Belsito DV, Taylor JS, et al. North American Contact Dermatitis Group patch test results: 2009 to 2010. Dermatitis 2013; 24:50-59.
    • (2013) Dermatitis , vol.24 , pp. 50-59
    • Warshaw, E.M.1    Belsito, D.V.2    Taylor, J.S.3
  • 10
    • 0035186093 scopus 로고    scopus 로고
    • Epidemiology of contact allergy in adults
    • Schäfer T, Bohler E, Ruhdorfer S, et al. Epidemiology of contact allergy in adults. Allergy 2001;56:1192-1196.
    • (2001) Allergy , vol.56 , pp. 1192-1196
    • Schäfer, T.1    Bohler, E.2    Ruhdorfer, S.3
  • 11
    • 84927760460 scopus 로고    scopus 로고
    • Body piercing and metal allergic contact sensitivity: North American Contact Dermatitis Group Data, 2007 to 2010
    • Warshaw EM, Kingsley-Loso JL, DeKoven JG, et al. Body piercing and metal allergic contact sensitivity: North American Contact Dermatitis Group Data, 2007 to 2010. Dermatitis. 2014;25:255-264.
    • (2014) Dermatitis , vol.25 , pp. 255-264
    • Warshaw, E.M.1    Kingsley-Loso, J.L.2    DeKoven, J.G.3
  • 12
    • 0026721297 scopus 로고
    • Clinical, immunological and bacteriological evaluation of adverse reactions to skin-penetrating titanium implants in the head and neck region
    • Holgers KM, Roupe G, Tjellstrom A, et al. Clinical, immunological and bacteriological evaluation of adverse reactions to skin-penetrating titanium implants in the head and neck region. Contact Dermatitis 1992;27:1-7.
    • (1992) Contact Dermatitis , vol.27 , pp. 1-7
    • Holgers, K.M.1    Roupe, G.2    Tjellstrom, A.3
  • 13
    • 43549083291 scopus 로고    scopus 로고
    • H1 type lymphocyte reactivity to metals in patients with total hip arthroplasty
    • H1 type lymphocyte reactivity to metals in patients with total hip arthroplasty. J Orthop Surg 2008;3:6.
    • (2008) J Orthop Surg , vol.3 , pp. 6
    • Hallab, N.J.1    Caicedo, M.2    Finnegan, A.3
  • 14
    • 0033816091 scopus 로고    scopus 로고
    • H1-type cytokine expression in the peri-implantar tissue
    • H1-type cytokine expression in the peri-implantar tissue. Allergy 2000;55:969-972.
    • (2000) Allergy , vol.55 , pp. 969-972
    • Thomas, P.1    Summer, B.2    Sander, C.A.3
  • 15
    • 77953640073 scopus 로고    scopus 로고
    • Nickel (Ni) allergic patients with complications to Ni containing joint replacement show preferential IL-17 type reactivity to Ni
    • Summer B, Paul C, Mazoochian F, et al. Nickel (Ni) allergic patients with complications to Ni containing joint replacement show preferential IL-17 type reactivity to Ni. Contact Dermatitis. 2010;63:15-22.
    • (2010) Contact Dermatitis , vol.63 , pp. 15-22
    • Summer, B.1    Paul, C.2    Mazoochian, F.3
  • 16
    • 84885176948 scopus 로고    scopus 로고
    • Systemic contact dermatitis and allergy to biomedical devices
    • Aquino M, Mucci T. Systemic contact dermatitis and allergy to biomedical devices. Curr Allergy Asthma Rep 2013;13:518-527.
    • (2013) Curr Allergy Asthma Rep , vol.13 , pp. 518-527
    • Aquino, M.1    Mucci, T.2
  • 17
    • 79955017566 scopus 로고    scopus 로고
    • Cutaneous and systemic hypersensitivity reactions to metallic implants
    • Basko-Plluska JL, Thyssen JP, Schalock PC. Cutaneous and systemic hypersensitivity reactions to metallic implants. Dermatitis 2011;22(2):65-79.
    • (2011) Dermatitis , vol.22 , Issue.2 , pp. 65-79
    • Basko-Plluska, J.L.1    Thyssen, J.P.2    Schalock, P.C.3
  • 18
    • 0029997499 scopus 로고    scopus 로고
    • Immune response to synthetic materials: Sensitization of patients receiving orthopaedic implants
    • Merritt K, Rodrigo JJ. Immune response to synthetic materials: sensitization of patients receiving orthopaedic implants. Clin Orthop Relat Res. 1996; 326:71-79.
    • (1996) Clin Orthop Relat Res , vol.326 , pp. 71-79
    • Merritt, K.1    Rodrigo, J.J.2
  • 20
    • 34249881862 scopus 로고    scopus 로고
    • The influence of corneocyte structure on the interpretation of permeation profiles of nanoparticles across skin
    • Pinheiro T, Pallon J, Alves LC, et al. The influence of corneocyte structure on the interpretation of permeation profiles of nanoparticles across skin. Nucl Instr Meth Phys Res B 2007;260(1):119-123.
    • (2007) Nucl Instr Meth Phys Res B , vol.260 , Issue.1 , pp. 119-123
    • Pinheiro, T.1    Pallon, J.2    Alves, L.C.3
  • 21
    • 70450247146 scopus 로고    scopus 로고
    • Metal is not inert: Role of metal ions released by biocorrosion in aseptic loosening - Current concepts
    • Cadosch D, Chan E, Gautschi OP, et al. Metal is not inert: role of metal ions released by biocorrosion in aseptic loosening - current concepts. J Biomed Mater Res 2009;91A:1252-1262.
    • (2009) J Biomed Mater Res , vol.91 A , pp. 1252-1262
    • Cadosch, D.1    Chan, E.2    Gautschi, O.P.3
  • 22
    • 51649121659 scopus 로고    scopus 로고
    • An electrochemical impedance investigation of the behavior of anodically oxidized titanium in human plasma and cognate fluids, relevant to dental applications
    • Bozinni B, Carlino P, Urzo LD, et al. An electrochemical impedance investigation of the behavior of anodically oxidized titanium in human plasma and cognate fluids, relevant to dental applications. J Mater Sci Mater Med 2008;19:3443-3453.
    • (2008) J Mater Sci Mater Med , vol.19 , pp. 3443-3453
    • Bozinni, B.1    Carlino, P.2    Urzo, L.D.3
  • 23
    • 3042663180 scopus 로고    scopus 로고
    • T lymphocyte-mediated immune responses to chemical haptens and metal ions: Implications for allergic and autoimmune disease
    • Martin SF. T lymphocyte-mediated immune responses to chemical haptens and metal ions: implications for allergic and autoimmune disease. Int Arch Allergy Immunol 2004;134:186-198.
    • (2004) Int Arch Allergy Immunol , vol.134 , pp. 186-198
    • Martin, S.F.1
  • 24
    • 0032932826 scopus 로고    scopus 로고
    • Formation of titanium(IV)-transferrin by reaction of human serum apotransferrin with titanium complexes
    • Messori L, Orioli P, Banholzer V, et al. Formation of titanium(IV)-transferrin by reaction of human serum apotransferrin with titanium complexes. FEBS Lett 1999;442:157-161.
    • (1999) FEBS Lett , vol.442 , pp. 157-161
    • Messori, L.1    Orioli, P.2    Banholzer, V.3
  • 25
    • 39549102641 scopus 로고    scopus 로고
    • Reconsideration of serum Ti(IV) transport: Albumin and transferrin trafficking of Ti(IV) and its complexes
    • Tinoco AD, Eames EV, Valentine AM. Reconsideration of serum Ti(IV) transport: albumin and transferrin trafficking of Ti(IV) and its complexes. J Am Chem Soc 2008;130:2262-2270.
    • (2008) J Am Chem Soc , vol.130 , pp. 2262-2270
    • Tinoco, A.D.1    Eames, E.V.2    Valentine, A.M.3
  • 26
    • 0034117155 scopus 로고    scopus 로고
    • Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement
    • Urban RM, Jacobs JJ, Tomlinson MJ, et al. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement. J Bone Joint Surg Am 2000;82:457-476.
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 457-476
    • Urban, R.M.1    Jacobs, J.J.2    Tomlinson, M.J.3
  • 27
    • 0026015477 scopus 로고
    • Sensitivity to titanium: A cause of implant failure?
    • Lalor PA, Revell PA, Gray AB, et al. Sensitivity to titanium: a cause of implant failure? J Bone Joint Surg Br 1991;73B:25-28.
    • (1991) J Bone Joint Surg Br , vol.73 B , pp. 25-28
    • Lalor, P.A.1    Revell, P.A.2    Gray, A.B.3
  • 28
    • 0024273585 scopus 로고
    • Titanium dioxide induced chemiluminescence of human polymorphonuclear leukocytes
    • Hedenborg M. Titanium dioxide induced chemiluminescence of human polymorphonuclear leukocytes. Int Arch Occup Environ Health 1988;61(1-2):1-6.
    • (1988) Int Arch Occup Environ Health , vol.61 , Issue.1-2 , pp. 1-6
    • Hedenborg, M.1
  • 29
    • 0036017274 scopus 로고    scopus 로고
    • Effects of Ti ions and particles on neutrophil function and morphology
    • Kumazawa R, Watari F, Takashi N, et al. Effects of Ti ions and particles on neutrophil function and morphology. Biomaterials 2002;23:3757-3764.
    • (2002) Biomaterials , vol.23 , pp. 3757-3764
    • Kumazawa, R.1    Watari, F.2    Takashi, N.3
  • 30
    • 0037209882 scopus 로고    scopus 로고
    • Immuno-inflammatory tissue reaction to stainless-steel and titanium plates used for internal fixation of long bones
    • Voggenreiter G, Leithing S, Brauer H, et al. Immuno-inflammatory tissue reaction to stainless-steel and titanium plates used for internal fixation of long bones. Biomaterials 2003;24:247-254.
    • (2003) Biomaterials , vol.24 , pp. 247-254
    • Voggenreiter, G.1    Leithing, S.2    Brauer, H.3
  • 31
    • 0035074458 scopus 로고    scopus 로고
    • Titanium particles stimulate bone resorption by inducing differentiation of murine osteoclasts
    • Bi Y, Van De Motter RR, Ragab AA, et al. Titanium particles stimulate bone resorption by inducing differentiation of murine osteoclasts. J Bone Joint Surg Am 2001;83:501-508.
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 501-508
    • Bi, Y.1    Van De Motter, R.R.2    Ragab, A.A.3
  • 32
    • 70349139323 scopus 로고    scopus 로고
    • Titanium IV ions induced human osteoclast differentiation and enhanced bone resorption in vitro
    • Cadosch D, Chan E, Gautschi OP, et al. Titanium IV ions induced human osteoclast differentiation and enhanced bone resorption in vitro. J Biomed Mater Res A 2009;91:29-36.
    • (2009) J Biomed Mater Res A , vol.91 , pp. 29-36
    • Cadosch, D.1    Chan, E.2    Gautschi, O.P.3
  • 33
    • 0029787081 scopus 로고    scopus 로고
    • Immuno-inflammatory responses in the tissue adjacent to titanium miniplates used in the treatment of mandibular fractures
    • Katou F, Andoh N, Motegi K, et al. Immuno-inflammatory responses in the tissue adjacent to titanium miniplates used in the treatment of mandibular fractures. J Craniomaxillofac Surg 1996;24(3):155-162.
    • (1996) J Craniomaxillofac Surg , vol.24 , Issue.3 , pp. 155-162
    • Katou, F.1    Andoh, N.2    Motegi, K.3
  • 34
    • 0036719501 scopus 로고    scopus 로고
    • A study of titanium release into body organs following the insertion of single threaded screw implants into the mandibles of sheep
    • Frisken KW, Dandie GW, Lugowski S, et al. A study of titanium release into body organs following the insertion of single threaded screw implants into the mandibles of sheep. Aust Dent J 2002;47(3):214-217.
    • (2002) Aust Dent J , vol.47 , Issue.3 , pp. 214-217
    • Frisken, K.W.1    Dandie, G.W.2    Lugowski, S.3
  • 35
    • 0027417781 scopus 로고
    • Ultrastructural findings in soft tissues adjacent to titanium plates used in jaw fracture treatment
    • Schliephake H, Lehmann H, Kunz U, et al. Ultrastructural findings in soft tissues adjacent to titanium plates used in jaw fracture treatment. Int J Oral Maxollofac Surg 1993;22:20-25.
    • (1993) Int J Oral Maxollofac Surg , vol.22 , pp. 20-25
    • Schliephake, H.1    Lehmann, H.2    Kunz, U.3
  • 36
    • 0035079773 scopus 로고    scopus 로고
    • Immunohistochemical characterization of the perivascular infiltrate cells in tissues adjacent to stainless steel implants compared with titanium implants
    • Thewes M, Kretschmer R, Gfesser M, et al. Immunohistochemical characterization of the perivascular infiltrate cells in tissues adjacent to stainless steel implants compared with titanium implants. Arch Orthop Trauma Surg 2001;121:223-226.
    • (2001) Arch Orthop Trauma Surg , vol.121 , pp. 223-226
    • Thewes, M.1    Kretschmer, R.2    Gfesser, M.3
  • 37
    • 0025886919 scopus 로고
    • Black staining around titanium alloy prostheses - An orthopaedic enigma
    • Scales JT. Black staining around titanium alloy prostheses - an orthopaedic enigma. J Bone Joint Surg Br 1991;73(4):534-536.
    • (1991) J Bone Joint Surg Br , vol.73 , Issue.4 , pp. 534-536
    • Scales, J.T.1
  • 38
    • 0025874154 scopus 로고
    • Metal wear and tissue response in failed titanium alloy total hip replacements
    • Witt JD, Swann M. Metal wear and tissue response in failed titanium alloy total hip replacements. J Bone Joint Surg Br 1991;73:559-563
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 559-563
    • Witt, J.D.1    Swann, M.2
  • 40
    • 0027322002 scopus 로고
    • Titanium lymph node pigmentation in the reconstruction plate system of a mandibular bone defect
    • Onodera K, Ooya K, Kawamura H. Titanium lymph node pigmentation in the reconstruction plate system of a mandibular bone defect. Oral Surg Oral Med Oral Pathol 1993;75:495-497.
    • (1993) Oral Surg Oral Med Oral Pathol , vol.75 , pp. 495-497
    • Onodera, K.1    Ooya, K.2    Kawamura, H.3
  • 41
    • 0028705691 scopus 로고
    • Titanium deposition in regional lymph nodes after insertion of titanium screw implants in maxillofacial region
    • Weingart D, Steinemann S, Schilli W, et al. Titanium deposition in regional lymph nodes after insertion of titanium screw implants in maxillofacial region. Int J Oral Maxillofac Surg 1994;23:450-452.
    • (1994) Int J Oral Maxillofac Surg , vol.23 , pp. 450-452
    • Weingart, D.1    Steinemann, S.2    Schilli, W.3
  • 42
    • 84949139657 scopus 로고
    • Accessed July 27, 2014
    • Foran JRH. Joint replacement [AAOS Web site]. 1995-2014. Available at: http://orthoinfo.aaos.org/menus/arthroplasty.cfm. Accessed July 27, 2014.
    • (1995) Joint Replacement
    • Foran, J.R.H.1
  • 43
    • 36048933313 scopus 로고    scopus 로고
    • The effect of mucine, IgA, urea, and lysozyme on the corrosion behavior of various non-precious dental alloys and pure titanium in artificial saliva
    • Bilhan H, Bilgin T, Cakir AF, et al. The effect of mucine, IgA, urea, and lysozyme on the corrosion behavior of various non-precious dental alloys and pure titanium in artificial saliva. J Biomater Appl 2007; 22:197-221.
    • (2007) J Biomater Appl , vol.22 , pp. 197-221
    • Bilhan, H.1    Bilgin, T.2    Cakir, A.F.3
  • 44
    • 0032923862 scopus 로고    scopus 로고
    • Metal release and excretion from cementless titanium alloy total knee replacements
    • Jacobs JJ, Silverton C, Hallab NJ, et al. Metal release and excretion from cementless titanium alloy total knee replacements. Clin Orthop Relat Res 1999;(358):173-180.
    • (1999) Clin Orthop Relat Res , Issue.358 , pp. 173-180
    • Jacobs, J.J.1    Silverton, C.2    Hallab, N.J.3
  • 45
    • 0026347807 scopus 로고
    • Release and excretion of metal in patients who have a total hip-replacement component made of titanium-base alloy
    • Jacobs JJ, Skipor MS, Black J, et al. Release and excretion of metal in patients who have a total hip-replacement component made of titanium-base alloy. J Bone Joint Surg 1991;73-A(10):1475-1486.
    • (1991) J Bone Joint Surg , vol.73-A , Issue.10 , pp. 1475-1486
    • Jacobs, J.J.1    Skipor, M.S.2    Black, J.3
  • 46
    • 0033761398 scopus 로고    scopus 로고
    • Serum titanium level for diagnosis of a failed, metal-backed patellar component
    • Leopold SS, Berger RA, Patterson L, et al. Serum titanium level for diagnosis of a failed, metal-backed patellar component. J Arthroplasty 2000;15:938-943.
    • (2000) J Arthroplasty , vol.15 , pp. 938-943
    • Leopold, S.S.1    Berger, R.A.2    Patterson, L.3
  • 47
    • 9644300933 scopus 로고    scopus 로고
    • Immune responses correlate with serum-metal in metal-on-metal hip arthroplasty
    • Hallab NJ, Anderson S, Caicedo M, et al. Immune responses correlate with serum-metal in metal-on-metal hip arthroplasty. J Arthroplasty 2004;19:88-93.
    • (2004) J Arthroplasty , vol.19 , pp. 88-93
    • Hallab, N.J.1    Anderson, S.2    Caicedo, M.3
  • 48
    • 84876234647 scopus 로고    scopus 로고
    • American Contact Dermatitis Society core allergen series
    • Schalock PC, Dunnick CA, Nedorost S, et al. American Contact Dermatitis Society core allergen series. Dermatitis 2013;24(1):7-9.
    • (2013) Dermatitis , vol.24 , Issue.1 , pp. 7-9
    • Schalock, P.C.1    Dunnick, C.A.2    Nedorost, S.3
  • 49
    • 84862221158 scopus 로고    scopus 로고
    • Current patch test results with the European baseline series and extensions to it from the 'European Surveillance System on Contact Allergy' network, 2007-2008
    • Uter W, Aberer W, Armario-Hita JC, et al. Current patch test results with the European baseline series and extensions to it from the 'European Surveillance System on Contact Allergy' network, 2007-2008. Contact Dermatitis 2012;67(1):9-19.
    • (2012) Contact Dermatitis , vol.67 , Issue.1 , pp. 9-19
    • Uter, W.1    Aberer, W.2    Armario-Hita, J.C.3
  • 50
    • 47249106421 scopus 로고    scopus 로고
    • Hypersensitivity reactions associated with endovascular devices
    • Honari G, Ellis SG, Wilkoff BL, et al. Hypersensitivity reactions associated with endovascular devices. Contact Dermatitis 2008;59:7-22.
    • (2008) Contact Dermatitis , vol.59 , pp. 7-22
    • Honari, G.1    Ellis, S.G.2    Wilkoff, B.L.3
  • 51
    • 49949104350 scopus 로고    scopus 로고
    • Retrospective evaluation of patch testing before or after metal device implantation
    • Reed KB, Davis MD, Nakamura K, et al. Retrospective evaluation of patch testing before or after metal device implantation. Arch Dermatol 2008;144(8):999-1007.
    • (2008) Arch Dermatol , vol.144 , Issue.8 , pp. 999-1007
    • Reed, K.B.1    Davis, M.D.2    Nakamura, K.3
  • 52
    • 82455164812 scopus 로고    scopus 로고
    • Patch testing with a large series of metal allergens: Findings from more than 1,000 patients in one decade at Mayo Clinic
    • Davis MDP, Wang MZ, Yiannias JA, et al. Patch testing with a large series of metal allergens: findings from more than 1,000 patients in one decade at Mayo Clinic. Dermatitis 2011;22(5):256-271.
    • (2011) Dermatitis , vol.22 , Issue.5 , pp. 256-271
    • Davis, M.D.P.1    Wang, M.Z.2    Yiannias, J.A.3
  • 53
    • 0031766437 scopus 로고    scopus 로고
    • Are allergic reactions to skin clips associated with delayed wound healing?
    • Lhotka CG, Szekeres T, Fritzer-Szekeres M, et al. Are allergic reactions to skin clips associated with delayed wound healing? Am J Surg 1998;176(4):320-323.
    • (1998) Am J Surg , vol.176 , Issue.4 , pp. 320-323
    • Lhotka, C.G.1    Szekeres, T.2    Fritzer-Szekeres, M.3
  • 54
    • 25644451995 scopus 로고    scopus 로고
    • The impact of metallic allergy on stent implantation: Metal allergy and recurrence of in-stent restenosis
    • IIjima R, Ikari Y, Amiya E, et al. The impact of metallic allergy on stent implantation: metal allergy and recurrence of in-stent restenosis. Int J Cardiol 2005;104:319-325.
    • (2005) Int J Cardiol , vol.104 , pp. 319-325
    • IIjima, R.1    Ikari, Y.2    Amiya, E.3
  • 55
    • 0000042447 scopus 로고    scopus 로고
    • A skin patch test for the diagnosis of titanium allergy
    • Okamura T, Morimoto M, Fukushima D, et al. A skin patch test for the diagnosis of titanium allergy. J Dent Res 1999;78(5):1135.
    • (1999) J Dent Res , vol.78 , Issue.5 , pp. 1135
    • Okamura, T.1    Morimoto, M.2    Fukushima, D.3
  • 56
    • 0027031864 scopus 로고
    • Allergy to components of total hip arthroplasty before and after surgery
    • Cancilleri F, DeGiorgis P, Verdoia C, et al. Allergy to components of total hip arthroplasty before and after surgery. Ital J Orthop Traumatol 1992;18(3):407-410.
    • (1992) Ital J Orthop Traumatol , vol.18 , Issue.3 , pp. 407-410
    • Cancilleri, F.1    DeGiorgis, P.2    Verdoia, C.3
  • 57
    • 38549138363 scopus 로고    scopus 로고
    • Sensitivity to implant materials in patients with total knee arthroplasties
    • Granchi D, Cenni E, Tigani D. Sensitivity to implant materials in patients with total knee arthroplasties. Biomaterials 2008;29:1494-1500.
    • (2008) Biomaterials , vol.29 , pp. 1494-1500
    • Granchi, D.1    Cenni, E.2    Tigani, D.3
  • 59
    • 79954461406 scopus 로고    scopus 로고
    • Metal sensitivity in patients with orthopaedic implants: A prospective study
    • Frigero E, Pigatto PD, Guzzi G, et al. Metal sensitivity in patients with orthopaedic implants: a prospective study. Contact Dermatitis 2011;64:273-279.
    • (2011) Contact Dermatitis , vol.64 , pp. 273-279
    • Frigero, E.1    Pigatto, P.D.2    Guzzi, G.3
  • 61
    • 34047211736 scopus 로고    scopus 로고
    • Hypersensitivity to titanium: Clinical and laboratory evidence
    • Müller K, Valentine-Thon E. Hypersensitivity to titanium: clinical and laboratory evidence. Neuroendocrinol Lett 2006;27(suppl 1):31-35.
    • (2006) Neuroendocrinol Lett , vol.27 , pp. 31-35
    • Müller, K.1    Valentine-Thon, E.2
  • 62
    • 84878694857 scopus 로고    scopus 로고
    • Prospective analysis of human leukocyte functional tests reveals metal sensitivity in patients with hip implant
    • Vermes C, Kuzsner J, Bárdos T, et al. Prospective analysis of human leukocyte functional tests reveals metal sensitivity in patients with hip implant. J Orthop Surg and Res 2013;8:12.
    • (2013) J Orthop Surg and Res , vol.8 , pp. 12
    • Vermes, C.1    Kuzsner, J.2    Bárdos, T.3
  • 63
    • 0016718479 scopus 로고
    • Incidence of metal sensitivity in patients with total joint replacements
    • Elves MW, Wilson JN, Scales JT, et al. Incidence of metal sensitivity in patients with total joint replacements. Br Med J 1975;4:376-378.
    • (1975) Br Med J , vol.4 , pp. 376-378
    • Elves, M.W.1    Wilson, J.N.2    Scales, J.T.3
  • 64
    • 0031904805 scopus 로고    scopus 로고
    • Sensitivity to metals in 40 patients with failed hip endoprosthesis
    • Milavec-Puretić V, Orlić D, Marusić A. Sensitivity to metals in 40 patients with failed hip endoprosthesis. Arch Orthop Trauma Surg 1998;117(6-7):383-386.
    • (1998) Arch Orthop Trauma Surg , vol.117 , Issue.6-7 , pp. 383-386
    • Milavec-Puretić, V.1    Orlić, D.2    Marusić, A.3
  • 66
    • 47149106401 scopus 로고    scopus 로고
    • Titanium allergy in dental implant patients: A clinical study on 1500 consecutive patients
    • Sicilia A, Cuesta S, Coma G, et al. Titanium allergy in dental implant patients: a clinical study on 1500 consecutive patients. Clin Oral Implants Res 2008;19(8):823-835.
    • (2008) Clin Oral Implants Res , vol.19 , Issue.8 , pp. 823-835
    • Sicilia, A.1    Cuesta, S.2    Coma, G.3
  • 68
    • 67650314648 scopus 로고    scopus 로고
    • Increased metal allergy in patients with failed metal-on-metal hip arthroplasty and peri-implant T-lymphocytic inflammation
    • Thomas P, Braathen LR, Dörig M. Increased metal allergy in patients with failed metal-on-metal hip arthroplasty and peri-implant T-lymphocytic inflammation. Allergy 2009;64(8):1157-1165.
    • (2009) Allergy , vol.64 , Issue.8 , pp. 1157-1165
    • Thomas, P.1    Braathen, L.R.2    Dörig, M.3
  • 69
    • 70049084721 scopus 로고    scopus 로고
    • Safety of nanosized particles in titanium dioxide- and zinc oxide-based sunscreens
    • Newman MD, Stotland M, Ellis JI. Safety of nanosized particles in titanium dioxide- and zinc oxide-based sunscreens. J Am Acad Dermatol 2009;61:685-692.
    • (2009) J Am Acad Dermatol , vol.61 , pp. 685-692
    • Newman, M.D.1    Stotland, M.2    Ellis, J.I.3
  • 70
    • 84874284386 scopus 로고    scopus 로고
    • Chromate or titanium allergy - The role of impurities?
    • Bernard S, Baeck M, Tennstedt D, et al. Chromate or titanium allergy - the role of impurities? Contact Dermatitis 2013;68(3):191-192.
    • (2013) Contact Dermatitis , vol.68 , Issue.3 , pp. 191-192
    • Bernard, S.1    Baeck, M.2    Tennstedt, D.3
  • 71
    • 0035857974 scopus 로고    scopus 로고
    • Allergy in coronary in-stent restenosis
    • Keane FM, Morris SD, Smith HR, et al. Allergy in coronary in-stent restenosis. Lancet 2001;357:1205-1206.
    • (2001) Lancet , vol.357 , pp. 1205-1206
    • Keane, F.M.1    Morris, S.D.2    Smith, H.R.3
  • 72
    • 0031706525 scopus 로고    scopus 로고
    • Titanium tetrachloride: An unusual agent with the potential to create severe burns
    • Paulsen SM, Nanney LB, Lynch JB. Titanium tetrachloride: an unusual agent with the potential to create severe burns. J Burn Care Rehabil 1998;19:377-381.
    • (1998) J Burn Care Rehabil , vol.19 , pp. 377-381
    • Paulsen, S.M.1    Nanney, L.B.2    Lynch, J.B.3
  • 73
    • 0344567653 scopus 로고
    • The toxicity of titanium tetrachloride
    • Lawson JJ. The toxicity of titanium tetrachloride. J Occup Med 1961;3:7-12.
    • (1961) J Occup Med , vol.3 , pp. 7-12
    • Lawson, J.J.1
  • 74
    • 0026650763 scopus 로고
    • Titanium tetrachloride burns to the eye
    • Chitkara DK, McNeela BJ. Titanium tetrachloride burns to the eye. Br J Ophthalmol 1992;76:380-382.
    • (1992) Br J Ophthalmol , vol.76 , pp. 380-382
    • Chitkara, D.K.1    McNeela, B.J.2
  • 76
    • 0032737023 scopus 로고    scopus 로고
    • Metal-specific lymphocytes: Biomarkers of sensitivity in man
    • Stejskal V, Danersund A, Lindvall A, et al. Metal-specific lymphocytes: biomarkers of sensitivity in man. Neuroendocrinol Lett 1999;20:289-298.
    • (1999) Neuroendocrinol Lett , vol.20 , pp. 289-298
    • Stejskal, V.1    Danersund, A.2    Lindvall, A.3
  • 77
    • 0037655988 scopus 로고    scopus 로고
    • Validity of MELISA® for metal sensitivity testing
    • Valentine-Thon E, Schiwara H-W. Validity of MELISA® for metal sensitivity testing. Neuroendocrinol Lett 2003;24(1/2):57-64.
    • (2003) Neuroendocrinol Lett , vol.24 , Issue.1-2 , pp. 57-64
    • Valentine-Thon, E.1    Schiwara, H.-W.2
  • 78
    • 0027987973 scopus 로고
    • MELISA - An in vitro tool for the study of metal allergy
    • Stejskal VDM, Cederbrant K, Lindvall A, et al. MELISA - an in vitro tool for the study of metal allergy. Toxicol In Vitro 1994;8:991-1000.
    • (1994) Toxicol in Vitro , vol.8 , pp. 991-1000
    • Stejskal, V.D.M.1    Cederbrant, K.2    Lindvall, A.3
  • 79
    • 0030723682 scopus 로고    scopus 로고
    • Human hapten-specific lymphocytes: Biomarkers of allergy in man
    • Stejskal V. Human hapten-specific lymphocytes: biomarkers of allergy in man. Drug Inform J 1997;31:1379-1382.
    • (1997) Drug Inform J , vol.31 , pp. 1379-1382
    • Stejskal, V.1
  • 80
    • 34047211957 scopus 로고    scopus 로고
    • LTT-MELISA® is clinically relevant for detecting and monitoring metal sensitivity
    • Valentine-Thon E, Müller K, Guzzi G, et al. LTT-MELISA® is clinically relevant for detecting and monitoring metal sensitivity. Neuroendocrinol Lett 2006;27(suppl 1):17-24.
    • (2006) Neuroendocrinol Lett , vol.27 , pp. 17-24
    • Valentine-Thon, E.1    Müller, K.2    Guzzi, G.3
  • 81
    • 0033814142 scopus 로고    scopus 로고
    • A triple assay technique for the evaluation of metal-induced delayed-type hypersensitivity responses in patients with or receiving total joint arthroplasty
    • Appl Biometer
    • Hallab NJ, Mikecz K, Joshua JJ. A triple assay technique for the evaluation of metal-induced delayed-type hypersensitivity responses in patients with or receiving total joint arthroplasty. Biomed Mater Res 2000; (Appl Biometer)53:480-489.
    • (2000) Biomed Mater Res , vol.53 , pp. 480-489
    • Hallab, N.J.1    Mikecz, K.2    Joshua, J.J.3
  • 82
    • 14244249263 scopus 로고    scopus 로고
    • Lymphocyte responses in patients with total hip arthroplasty
    • Hallab NJ, Anderson S, Stafford T, et al. Lymphocyte responses in patients with total hip arthroplasty. J Orthop Res 2005;23:384-391.
    • (2005) J Orthop Res , vol.23 , pp. 384-391
    • Hallab, N.J.1    Anderson, S.2    Stafford, T.3
  • 83
    • 84884840841 scopus 로고    scopus 로고
    • Allergy or tolerance: Reduced inflammatory cytokine response and concomitant IL-10 production of lymphocytes and monocytes in symptom-free titanium dental implant patients
    • Thomas P, Iglhaut G, Wollenberg A, et al. Allergy or tolerance: reduced inflammatory cytokine response and concomitant IL-10 production of lymphocytes and monocytes in symptom-free titanium dental implant patients. BioMed Res Int 2013;2013:539834
    • (2013) BioMed Res Int , vol.2013 , pp. 539834
    • Thomas, P.1    Iglhaut, G.2    Wollenberg, A.3
  • 84
    • 0022399777 scopus 로고
    • The lymphocytic transformation test (L.T.T.) in the evaluation of intolerance in prosthetic implants
    • Carando S, Cannas M, Rossi P, et al. The lymphocytic transformation test (L.T.T.) in the evaluation of intolerance in prosthetic implants. Ital J Orthop Traumatol 1985;11:475-481.
    • (1985) Ital J Orthop Traumatol , vol.11 , pp. 475-481
    • Carando, S.1    Cannas, M.2    Rossi, P.3
  • 85
    • 0031051717 scopus 로고    scopus 로고
    • In vitro lymphocyte proliferation as compared to patch test using gold, palladium and nickel
    • Cederbrant K, Hultman P, Marcusson JA, et al. In vitro lymphocyte proliferation as compared to patch test using gold, palladium and nickel. Int Arch Allergy Immunol 1997;112:212-217.
    • (1997) Int Arch Allergy Immunol , vol.112 , pp. 212-217
    • Cederbrant, K.1    Hultman, P.2    Marcusson, J.A.3
  • 86
    • 0019863795 scopus 로고
    • Metal sensitivity reactions to orthopedic implants
    • Mar
    • Merritt K, Brown SA. Metal sensitivity reactions to orthopedic implants. Int J Dermatol Mar 1981;20(2):89-94.
    • (1981) Int J Dermatol , vol.20 , Issue.2 , pp. 89-94
    • Merritt, K.1    Brown, S.A.2
  • 87
    • 0027267474 scopus 로고
    • Intradermal testing in the diagnosis of allergic contact dermatitis: A reappraisal
    • Herbst RA, Lauerma AI, Maibach HI. Intradermal testing in the diagnosis of allergic contact dermatitis: a reappraisal. Contact Dermatitis 1993; 29:1-5.
    • (1993) Contact Dermatitis , vol.29 , pp. 1-5
    • Herbst, R.A.1    Lauerma, A.I.2    Maibach, H.I.3
  • 88
    • 0019692275 scopus 로고
    • New simple early diagnostic methods using Omura's "bidigital O-ring dysfunction localization method" and acupuncture organ representation points, and their applications to the "drug & food compatibility test" for individual organs and to auricular diagnosis of internal organs-part I
    • Omura Y. New simple early diagnostic methods using Omura's "bidigital O-ring dysfunction localization method" and acupuncture organ representation points, and their applications to the "drug & food compatibility test" for individual organs and to auricular diagnosis of internal organs-part I. Acupunct Electrother Res 1981;6:239-254.
    • (1981) Acupunct Electrother Res , vol.6 , pp. 239-254
    • Omura, Y.1
  • 89
    • 0035234463 scopus 로고    scopus 로고
    • A case of allergic reaction to surgical metal clips inserted for postoperative boost irradiation in a patient undergoing breast-conserving therapy
    • Tamai K, Mitsumori M, Fujishiro S, et al. A case of allergic reaction to surgical metal clips inserted for postoperative boost irradiation in a patient undergoing breast-conserving therapy. Breast Cancer 2001;8(1):90-92.
    • (2001) Breast Cancer , vol.8 , Issue.1 , pp. 90-92
    • Tamai, K.1    Mitsumori, M.2    Fujishiro, S.3
  • 92
    • 0021960355 scopus 로고
    • Pacemaker contact sensitivity
    • Verbov J. Pacemaker contact sensitivity. Contact Dermatitis 1985;12(3):173.
    • (1985) Contact Dermatitis , vol.12 , Issue.3 , pp. 173
    • Verbov, J.1
  • 94
    • 0028346048 scopus 로고
    • Pacemaker contact sensitivity: Clinical recognition and management
    • Abdallah HI, Balsara RK, O'Riordan AC. Pacemaker contact sensitivity: clinical recognition and management. Ann Thorac Surg 1994;57(4):1017-1018.
    • (1994) Ann Thorac Surg , vol.57 , Issue.4 , pp. 1017-1018
    • Abdallah, H.I.1    Balsara, R.K.2    O'Riordan, A.C.3
  • 95
    • 0029585192 scopus 로고
    • Granulomatous dermatitis after implantation of a titanium-containing pacemaker
    • Viraben R, Boulinquez S, Alba C. Granulomatous dermatitis after implantation of a titanium-containing pacemaker. Contact Dermatitis 1995;33(6):437.
    • (1995) Contact Dermatitis , vol.33 , Issue.6 , pp. 437
    • Viraben, R.1    Boulinquez, S.2    Alba, C.3
  • 96
    • 33750689507 scopus 로고    scopus 로고
    • Pacemaker contact dermatitis: The effective use of a polytetrafluoroethylene sheet
    • Ishii K, Kodani E, Miyamoto S, et al. Pacemaker contact dermatitis: the effective use of a polytetrafluoroethylene sheet. Pacing Clin Electrophysiol 2006;29:1299-1302.
    • (2006) Pacing Clin Electrophysiol , vol.29 , pp. 1299-1302
    • Ishii, K.1    Kodani, E.2    Miyamoto, S.3
  • 97
    • 77951960387 scopus 로고    scopus 로고
    • Gold-coated pacemaker implantation after allergic reactions to pacemaker compounds
    • Syburra T, Schurr U, Rahn M, et al. Gold-coated pacemaker implantation after allergic reactions to pacemaker compounds. Europace 2010;12(5):749-750.
    • (2010) Europace , vol.12 , Issue.5 , pp. 749-750
    • Syburra, T.1    Schurr, U.2    Rahn, M.3
  • 98
    • 0025390282 scopus 로고
    • Tissue reaction involving an intraoral skin graft and CP titanium abutments: A clinical report
    • Mitchell DL, Synnott SA, VanDercreek JA. Tissue reaction involving an intraoral skin graft and CP titanium abutments: a clinical report. Int J Oral Maxillofac Implants 1990;5(1):79-84.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , Issue.1 , pp. 79-84
    • Mitchell, D.L.1    Synnott, S.A.2    VanDercreek, J.A.3
  • 99
    • 34247877576 scopus 로고    scopus 로고
    • Implant failure due to titanium hypersensitivity/allergy? Report of a case
    • du Preez LA, Bütow KW, Swart TJP. Implant failure due to titanium hypersensitivity/allergy? Report of a case. SADJ 2007;62(1):22-25.
    • (2007) SADJ , vol.62 , Issue.1 , pp. 22-25
    • Du Preez, L.A.1    Bütow, K.W.2    Swart, T.J.P.3
  • 100
    • 55249122493 scopus 로고    scopus 로고
    • Suspected association of an allergic reaction with titanium dental implants: A clinical report
    • Egusa H, Ko N, Shimazu T, et al. Suspected association of an allergic reaction with titanium dental implants: a clinical report. J Prosthet Dent 2008;100(5):344-347.
    • (2008) J Prosthet Dent , vol.100 , Issue.5 , pp. 344-347
    • Egusa, H.1    Ko, N.2    Shimazu, T.3
  • 101
    • 33748454877 scopus 로고    scopus 로고
    • Hypersensitivity to titanium osteosynthesis with impaired fracture healing, eczema, and T-cell hyperresponsiveness in vitro: Case report and review of the literature
    • Thomas P, Bandl WD, Maier S, et al. Hypersensitivity to titanium osteosynthesis with impaired fracture healing, eczema, and T-cell hyperresponsiveness in vitro: case report and review of the literature. Contact Dermatitis 2006;55:199-202.
    • (2006) Contact Dermatitis , vol.55 , pp. 199-202
    • Thomas, P.1    Bandl, W.D.2    Maier, S.3
  • 102
    • 81855216235 scopus 로고    scopus 로고
    • Revision of a tibial baseplate using a customized oxinium component in a case of suspected metal allergy: A case report
    • Opstal NV, Verheyden F. Revision of a tibial baseplate using a customized oxinium component in a case of suspected metal allergy: a case report. Acta Orthop Belg 2011;77:691-695.
    • (2011) Acta Orthop Belg , vol.77 , pp. 691-695
    • Opstal, N.V.1    Verheyden, F.2
  • 103
    • 84949139658 scopus 로고    scopus 로고
    • Hypersensitivity to suture anchors
    • Goto M, Gotoh M, Mitsui Y, et al. Hypersensitivity to suture anchors. Case Rep Orthop 2013;2013:932167.
    • (2013) Case Rep Orthop , vol.2013 , pp. 932167
    • Goto, M.1    Gotoh, M.2    Mitsui, Y.3
  • 104
    • 34548675584 scopus 로고    scopus 로고
    • Drug rash with eosinophilia and systemic symptoms (DRESS) syndrome: Suspected association with titanium bioprosthesis
    • Nawaz F, Wall BM. Drug rash with eosinophilia and systemic symptoms (DRESS) syndrome: suspected association with titanium bioprosthesis. Am J Med Sci 2007;334(3):215-218.
    • (2007) Am J Med Sci , vol.334 , Issue.3 , pp. 215-218
    • Nawaz, F.1    Wall, B.M.2
  • 105
    • 84865807352 scopus 로고    scopus 로고
    • Mortality after local allergic response to titanium cranioplasty
    • Hettige S, Norris JS. Mortality after local allergic response to titanium cranioplasty. Acta Neurochir 2012;154:1725-1726.
    • (2012) Acta Neurochir , vol.154 , pp. 1725-1726
    • Hettige, S.1    Norris, J.S.2
  • 106
    • 0022536922 scopus 로고
    • Granulomatous disease associated with pulmonary deposition of titanium
    • Redline S, Barna B, Tomashefski JF, et al. Granulomatous disease associated with pulmonary deposition of titanium. Br J Ind Med 1986; 43:652-656.
    • (1986) Br J Ind Med , vol.43 , pp. 652-656
    • Redline, S.1    Barna, B.2    Tomashefski, J.F.3
  • 107
    • 33748931429 scopus 로고    scopus 로고
    • Granulomatous reaction to titanium alloy: An unusual reaction to ear piercing
    • High WA, Ayers RA, Adams JR, et al. Granulomatous reaction to titanium alloy: an unusual reaction to ear piercing. J Am Acad Dermatol 2006;55(4):716-720.
    • (2006) J Am Acad Dermatol , vol.55 , Issue.4 , pp. 716-720
    • High, W.A.1    Ayers, R.A.2    Adams, J.R.3
  • 108
    • 84883238137 scopus 로고    scopus 로고
    • Severe allergic dermatitis after closure of foramen ovale with Amplatzer occlude
    • Belohlavek J, Belohlavkova S, Hlubocky J, et al. Severe allergic dermatitis after closure of foramen ovale with Amplatzer occlude. Ann Thorac Surg 2013;96:e57-e59.
    • (2013) Ann Thorac Surg , vol.96 , pp. e57-e59
    • Belohlavek, J.1    Belohlavkova, S.2    Hlubocky, J.3
  • 109
    • 79959210164 scopus 로고    scopus 로고
    • Titanium allergy: Could it affect dental implant integration?
    • Siddiqi A, Payne AG, DeSilva RK, et al. Titanium allergy: could it affect dental implant integration? Clin Oral Implants Res 2011;22(7):673-680.
    • (2011) Clin Oral Implants Res , vol.22 , Issue.7 , pp. 673-680
    • Siddiqi, A.1    Payne, A.G.2    DeSilva, R.K.3
  • 110
    • 0036367644 scopus 로고    scopus 로고
    • Implant failure with spontaneous rapid exfoliation: Case reports
    • Deas DE, Mikotowicz JJ, Mackey SA, et al. Implant failure with spontaneous rapid exfoliation: case reports. Implant Dent 2002;11(3):235-242.
    • (2002) Implant Dent , vol.11 , Issue.3 , pp. 235-242
    • Deas, D.E.1    Mikotowicz, J.J.2    Mackey, S.A.3
  • 111
    • 84891644642 scopus 로고    scopus 로고
    • Titanium hypersensitivity: A hidden threat for dental implants?
    • Bilhan H, Bural C, Geckili O. Titanium hypersensitivity: a hidden threat for dental implants? N Y State Dent J 2013;79(4):38-43.
    • (2013) N y State Dent J , vol.79 , Issue.4 , pp. 38-43
    • Bilhan, H.1    Bural, C.2    Geckili, O.3
  • 112
    • 84883377508 scopus 로고    scopus 로고
    • Allergy related to dental implant and its significance
    • Chaturvedi TP. Allergy related to dental implant and its significance. Clin Cosmet Invest Dent 2013;5:57-61
    • (2013) Clin Cosmet Invest Dent , vol.5 , pp. 57-61
    • Chaturvedi, T.P.1
  • 113
    • 0029047008 scopus 로고
    • Pulmonary alveolar proteinosis in a painter with elevated pulmonary concentrations of titanium
    • Keller CA, Frost A, Cagle PT, et al. Pulmonary alveolar proteinosis in a painter with elevated pulmonary concentrations of titanium. Chest 1995;108(1):277-280.
    • (1995) Chest , vol.108 , Issue.1 , pp. 277-280
    • Keller, C.A.1    Frost, A.2    Cagle, P.T.3
  • 114
    • 0038136756 scopus 로고    scopus 로고
    • Titanium particles identified by energy-dispersive x-ray microanalysis within the lungs of a painter at autopsy
    • Humble S, Tucker JA, Boudreaux C, et al. Titanium particles identified by energy-dispersive x-ray microanalysis within the lungs of a painter at autopsy. Ultrastruct Pathol 2003;27:127-129.
    • (2003) Ultrastruct Pathol , vol.27 , pp. 127-129
    • Humble, S.1    Tucker, J.A.2    Boudreaux, C.3
  • 115
    • 0018886397 scopus 로고
    • Sensitivity caused by internal exposure to nickel, chrome and cobalt
    • Tilsley DA, Rotstein H. Sensitivity caused by internal exposure to nickel, chrome and cobalt. Contact Dermatitis 1980;6:175-178.
    • (1980) Contact Dermatitis , vol.6 , pp. 175-178
    • Tilsley, D.A.1    Rotstein, H.2
  • 117
    • 0035083726 scopus 로고    scopus 로고
    • Allergic contact dermatitis caused by palladium on titanium spectacle frames
    • Suhonen R, Kanerva L. Allergic contact dermatitis caused by palladium on titanium spectacle frames. Contact Dermatitis 2001;44:257.
    • (2001) Contact Dermatitis , vol.44 , pp. 257
    • Suhonen, R.1    Kanerva, L.2
  • 118
    • 0034793604 scopus 로고    scopus 로고
    • Allergic contact dermatitis from "titanium" spectacle frames
    • Bircher AJ, Stern WB. Allergic contact dermatitis from "titanium" spectacle frames. Contact Dermatitis 2001;45:244-245.
    • (2001) Contact Dermatitis , vol.45 , pp. 244-245
    • Bircher, A.J.1    Stern, W.B.2
  • 119
    • 79961090764 scopus 로고    scopus 로고
    • Impaired wound-healing, local eczema, and chronic inflammation following titanium osteosynthesis in a nickel and cobalt-allergic patient
    • 1-5
    • Thomas P, Thomas M, Summer B, et al. Impaired wound-healing, local eczema, and chronic inflammation following titanium osteosynthesis in a nickel and cobalt-allergic patient. J Bone Joint Surg Am 2011;93:e61(1-5).
    • (2011) J Bone Joint Surg Am , vol.93 , pp. e61
    • Thomas, P.1    Thomas, M.2    Summer, B.3
  • 120
    • 84867007686 scopus 로고    scopus 로고
    • Allergic contact stomatitis caused by a titanium nitride-coated implant abutment: A clinical report
    • Lim H-P, Lee K-M, Koh Y-I, et al. Allergic contact stomatitis caused by a titanium nitride-coated implant abutment: a clinical report. J Prosthet Dent 2012;108:209-213.
    • (2012) J Prosthet Dent , vol.108 , pp. 209-213
    • Lim, H.-P.1    Lee, K.-M.2    Koh, Y.-I.3
  • 121
    • 84864575110 scopus 로고    scopus 로고
    • Pin site allergic contact dermatitis: An unusual complication of halo fixation
    • Coulter I, Lee M, Zakaria R, et al. Pin site allergic contact dermatitis: an unusual complication of halo fixation. Br J Neurosurg 2012;26(4):566-567.
    • (2012) Br J Neurosurg , vol.26 , Issue.4 , pp. 566-567
    • Coulter, I.1    Lee, M.2    Zakaria, R.3
  • 122
    • 77954695282 scopus 로고    scopus 로고
    • Full-mouth oral rehabilitation in a titanium allergy patient using zirconium oxide dental implants and zirconium oxide restorations: A case report from an ongoing clinical study
    • Oliva X, Oliva J, Oliva JD. Full-mouth oral rehabilitation in a titanium allergy patient using zirconium oxide dental implants and zirconium oxide restorations: a case report from an ongoing clinical study. Eur J Esthet Dent 2010;5(2):190-203.
    • (2010) Eur J Esthet Dent , vol.5 , Issue.2 , pp. 190-203
    • Oliva, X.1    Oliva, J.2    Oliva, J.D.3
  • 124
    • 84884125029 scopus 로고    scopus 로고
    • Safety of intra-articular celltherapy with culture-expanded stem cells in humans: A systematic literature review
    • Peeters CMM, Leijs MJC, Reijman M, et al. Safety of intra-articular celltherapy with culture-expanded stem cells in humans: a systematic literature review. Osteoarthritis Cartilage 2013;21:1465-1473.
    • (2013) Osteoarthritis Cartilage , vol.21 , pp. 1465-1473
    • Peeters, C.M.M.1    Leijs, M.J.C.2    Reijman, M.3
  • 125
    • 84949139659 scopus 로고    scopus 로고
    • [database online]. Bethesda, MD: National Institutes of Health National Library of Medicine; February 29, Updated daily. Accessed August 10, 2014
    • www.clinicaltrials.gov [database online]. Bethesda, MD: National Institutes of Health National Library of Medicine; February 29, 2000. Updated daily. Accessed August 10, 2014.
    • (2000)
  • 126
    • 72549118783 scopus 로고    scopus 로고
    • The association between metal allergy, total hip arthroplasty, and revision
    • Thyssen JP, Jakobsen SS, Engkilde K, et al. The association between metal allergy, total hip arthroplasty, and revision. Acta Orthop 2009;80:646-652.
    • (2009) Acta Orthop , vol.80 , pp. 646-652
    • Thyssen, J.P.1    Jakobsen, S.S.2    Engkilde, K.3
  • 127
    • 0035259085 scopus 로고    scopus 로고
    • Cutaneous metal sensitivity in patients with orthopaedic injuries
    • Swiontkowski MF, Agel J, Schwappach J, et al. Cutaneous metal sensitivity in patients with orthopaedic injuries. J Orthop Trauma 2001;15:86-89.
    • (2001) J Orthop Trauma , vol.15 , pp. 86-89
    • Swiontkowski, M.F.1    Agel, J.2    Schwappach, J.3
  • 128
    • 84881318896 scopus 로고    scopus 로고
    • The role of patch testing in the evaluation of orthopedic implant-related adverse effects: Current evidence does not support broad use
    • Crawford GH. The role of patch testing in the evaluation of orthopedic implant-related adverse effects: current evidence does not support broad use. Dermatitis 2013;24:99-103.
    • (2013) Dermatitis , vol.24 , pp. 99-103
    • Crawford, G.H.1
  • 129
    • 84888259433 scopus 로고    scopus 로고
    • Metal hypersensitivity reactions to implants: Opinions and practices of patch testing dermatologists
    • Schalock PC, Thyssen JP. Metal hypersensitivity reactions to implants: opinions and practices of patch testing dermatologists. Dermatitis 2013;24(6):313-320.
    • (2013) Dermatitis , vol.24 , Issue.6 , pp. 313-320
    • Schalock, P.C.1    Thyssen, J.P.2
  • 130
    • 38649085629 scopus 로고    scopus 로고
    • Orthopedic surgical implants and allergies: Joint statement by the implant allergy working group (AK 20) of the DGOOC (German Association of Orthopedics and Orthopedic Surgery), DKG (German Contact Dermatitis Research Group) and DGAKI (German Society for Allergology and Clinical Immunology)
    • Thomas P, Schuh A, Ring J, et al. Orthopedic surgical implants and allergies: joint statement by the implant allergy working group (AK 20) of the DGOOC (German Association of Orthopedics and Orthopedic Surgery), DKG (German Contact Dermatitis Research Group) and DGAKI (German Society for Allergology and Clinical Immunology). Orthopade 2008;37:75-88.
    • (2008) Orthopade , vol.37 , pp. 75-88
    • Thomas, P.1    Schuh, A.2    Ring, J.3
  • 131
    • 84928104087 scopus 로고    scopus 로고
    • Metal allergy screening prior to joint arthroplasty and its influence on implant choice: A Delphi consensus study amongst orthopaedic arthroplasty surgeons
    • Razak A, Ebinesan AD, Charalambous CP. Metal allergy screening prior to joint arthroplasty and its influence on implant choice: a Delphi consensus study amongst orthopaedic arthroplasty surgeons. Knee Surg Relat Res 2013;25(4):186-193.
    • (2013) Knee Surg Relat Res , vol.25 , Issue.4 , pp. 186-193
    • Razak, A.1    Ebinesan, A.D.2    Charalambous, C.P.3
  • 132
    • 79952408954 scopus 로고    scopus 로고
    • Pragmatic approach to the clinical work-up of patients with putative allergic disease to metallic orthopaedic implants before and after surgery
    • Thyssen JP, Menne T, Schalock PC, et al. Pragmatic approach to the clinical work-up of patients with putative allergic disease to metallic orthopaedic implants before and after surgery. Br J Dermatol 2011; 164:473-478.
    • (2011) Br J Dermatol , vol.164 , pp. 473-478
    • Thyssen, J.P.1    Menne, T.2    Schalock, P.C.3
  • 133
    • 83455258023 scopus 로고    scopus 로고
    • Hypersensitivity reactions to metallic implants-diagnostic algorithm and suggested patch test series for clinical use
    • Schalock PC, Menne T, Johansen JD, et al. Hypersensitivity reactions to metallic implants-diagnostic algorithm and suggested patch test series for clinical use. Contact Dermatitis 2011;66:4-19.
    • (2011) Contact Dermatitis , vol.66 , pp. 4-19
    • Schalock, P.C.1    Menne, T.2    Johansen, J.D.3
  • 134
    • 4444313276 scopus 로고    scopus 로고
    • Screening for symptomatic metal sensitivity: A prospective study of 92 patients undergoing total knee arthroplasty
    • Niki Y, Matsumoto H, Otani T, et al. Screening for symptomatic metal sensitivity: a prospective study of 92 patients undergoing total knee arthroplasty. Biomaterials 2005;26:1019-1026.
    • (2005) Biomaterials , vol.26 , pp. 1019-1026
    • Niki, Y.1    Matsumoto, H.2    Otani, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.