메뉴 건너뛰기




Volumn 117, Issue 6-7, 1998, Pages 383-386

Sensitivity to metals in 40 patients with failed hip endoprosthesis

Author keywords

[No Author keywords available]

Indexed keywords

ALLERGEN; CHROMIUM; COBALT; METAL; NICKEL; STAINLESS STEEL;

EID: 0031904805     PISSN: 09368051     EISSN: None     Source Type: Journal    
DOI: 10.1007/s004020050272     Document Type: Article
Times cited : (53)

References (10)
  • 1
    • 0029809718 scopus 로고    scopus 로고
    • Metal on metal bearings in hip arthroplasty
    • Amstutz HC, Grigoris P (1996) Metal on metal bearings in hip arthroplasty. Clin Orthop 329S : 11-34
    • (1996) Clin Orthop , vol.329 S , pp. 11-34
    • Amstutz, H.C.1    Grigoris, P.2
  • 2
    • 0016820637 scopus 로고
    • Metal sensitivity in patients with joint replacement arthroplasties
    • Benson MKD, Goodwin PG, Brostoff J (1975) Metal sensitivity in patients with joint replacement arthroplasties. BMJ 4 : 374-375
    • (1975) BMJ , vol.4 , pp. 374-375
    • Benson, M.K.D.1    Goodwin, P.G.2    Brostoff, J.3
  • 4
    • 0018890809 scopus 로고
    • Metal sensitivity in patients with metal-to-plastic total hip arthroplasties
    • Carlsson AS, Magnusson B, Möller H (1980) Metal sensitivity in patients with metal-to-plastic total hip arthroplasties. Acta Orthop Scand 51 : 57-62
    • (1980) Acta Orthop Scand , vol.51 , pp. 57-62
    • Carlsson, A.S.1    Magnusson, B.2    Möller, H.3
  • 6
    • 0027263208 scopus 로고
    • Nickel sensitivity and the implantation of orthopaedic prostheses
    • Gawkrodger DJ (1993) Nickel sensitivity and the implantation of orthopaedic prostheses. Contact Dermatitis 28 : 257-259
    • (1993) Contact Dermatitis , vol.28 , pp. 257-259
    • Gawkrodger, D.J.1
  • 7
    • 0029814931 scopus 로고    scopus 로고
    • Distribution of cobalt chromium wear and corrosion products and biologic reaction
    • Merritt K, Brown SA (1996) Distribution of cobalt chromium wear and corrosion products and biologic reaction. Clin Orthop 329S : 233-243
    • (1996) Clin Orthop , vol.329 S , pp. 233-243
    • Merritt, K.1    Brown, S.A.2
  • 8
    • 0027993627 scopus 로고
    • Metal allergy in scoliotic patients treated by subcutaneous Harrington instrumentation
    • Milavec-Puretić V, Antičević D, Kovač V, Šmigovec E (1994) Metal allergy in scoliotic patients treated by subcutaneous Harrington instrumentation. Croatian Med J 35 : 108-110
    • (1994) Croatian Med J , vol.35 , pp. 108-110
    • Milavec-Puretić, V.1    Antičević, D.2    Kovač, V.3    Šmigovec, E.4
  • 9
    • 3042841894 scopus 로고
    • Assays for detection of complement-fixing immune complexes (Raji cells, conglutinin, and anti-C3 assay)
    • Rose NR, Friedman H (eds) American Society for Microbiology, New York
    • Theofilopoulos AN, Pereira AB, Eisenberg RA, Dixon FJ (1980) Assays for detection of complement-fixing immune complexes (Raji cells, conglutinin, and anti-C3 assay). In: Rose NR, Friedman H (eds) Manual of clinical immunology. American Society for Microbiology, New York, pp 186-189
    • (1980) Manual of Clinical Immunology , pp. 186-189
    • Theofilopoulos, A.N.1    Pereira, A.B.2    Eisenberg, R.A.3    Dixon, F.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.