메뉴 건너뛰기




Volumn 69, Issue 10, 2015, Pages 1109-1112

Changes in muscle and fat mass with haemodialysis detected by multi-frequency bioelectrical impedance analysis

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; BODY COMPOSITION; BODY FAT; BODY WATER; CLINICAL ASSESSMENT TOOL; CONTROLLED STUDY; EXTRACELLULAR FLUID; FAT MASS; FEMALE; HEMODIALYSIS; HUMAN; LEAN BODY WEIGHT; MAJOR CLINICAL STUDY; MALE; MULTI FREQUENCY BIOELECTRICAL IMPEDANCE ANALYSIS; MUSCLE MASS; NUTRITIONAL STATUS; OUTCOME ASSESSMENT; OUTPATIENT CARE; REPRODUCIBILITY; SKELETAL MUSCLE; WEIGHT CHANGE; ADIPOSE TISSUE; AGED; ANTHROPOMETRY; BODY WEIGHT; IMPEDANCE; METABOLIC DISORDER; METABOLISM; MIDDLE AGED; PROCEDURES; RENAL REPLACEMENT THERAPY; VALIDATION STUDY; VERY ELDERLY; YOUNG ADULT;

EID: 84943650440     PISSN: 09543007     EISSN: 14765640     Source Type: Journal    
DOI: 10.1038/ejcn.2015.90     Document Type: Article
Times cited : (57)

References (24)
  • 1
    • 84907597437 scopus 로고    scopus 로고
    • The role of bioimpedance and biomarkers in helping to aid clinical decision-making of volume assessments in dialysis patients
    • Davies SJ, Davenport A. The role of bioimpedance and biomarkers in helping to aid clinical decision-making of volume assessments in dialysis patients. Kidney Int 2014; 86: 489-496.
    • (2014) Kidney Int , vol.86 , pp. 489-496
    • Davies, S.J.1    Davenport, A.2
  • 2
    • 0036113534 scopus 로고    scopus 로고
    • A new technique for establishing dry weight in haemodialysis patients via whole body bioimpedance
    • Chamney PW, Krämer M, Rode C, Kleinekofort W, Wizemann V. A new technique for establishing dry weight in haemodialysis patients via whole body bioimpedance. Kidney Int 2002; 61: 2250-2258.
    • (2002) Kidney Int , vol.61 , pp. 2250-2258
    • Chamney, P.W.1    Krämer, M.2    Rode, C.3    Kleinekofort, W.4    Wizemann, V.5
  • 3
    • 84885516487 scopus 로고    scopus 로고
    • The effects of racial differences on body composition and total body water measured by multifrequency bioelectrical impedance analysis influence delivered Kt/V dialysis dosing
    • Kumar S, Khosravi M, Massart A, Potluri M, Davenport A. The effects of racial differences on body composition and total body water measured by multifrequency bioelectrical impedance analysis influence delivered Kt/V dialysis dosing. Nephron Clin Pract 2013; 124: 60-66.
    • (2013) Nephron Clin Pract , vol.124 , pp. 60-66
    • Kumar, S.1    Khosravi, M.2    Massart, A.3    Potluri, M.4    Davenport, A.5
  • 4
    • 80053906168 scopus 로고    scopus 로고
    • The effect of racial origin on total body water volume in peritoneal dialysis patients
    • Davenport A, Hussain Sayed R, Fan S. The effect of racial origin on total body water volume in peritoneal dialysis patients. Clin J Am Soc Nephrol 2011; 6: 2492-2498.
    • (2011) Clin J Am Soc Nephrol , vol.6 , pp. 2492-2498
    • Davenport, A.1    Hussain Sayed, R.2    Fan, S.3
  • 5
    • 84897377374 scopus 로고    scopus 로고
    • Comparison of fluid volume estimates in chronic haemodialysis patients by bioimpedance, direct isotopic, and dilution methods
    • Raimann JG, Zhu F, Wang J, Thijssen S, Kuhlmann MK, Kotanko P et al. Comparison of fluid volume estimates in chronic haemodialysis patients by bioimpedance, direct isotopic, and dilution methods. Kidney Int 2014; 85: 898-908.
    • (2014) Kidney Int , vol.85 , pp. 898-908
    • Raimann, J.G.1    Zhu, F.2    Wang, J.3    Thijssen, S.4    Kuhlmann, M.K.5    Kotanko, P.6
  • 6
    • 8744237041 scopus 로고    scopus 로고
    • Bioelectrical impedance analysis-part II: Utilization in clinical practice
    • Composition of the ESPEN Working Group
    • Kyle UG, Bosaeus I, De Lorenzo AD, Deurenberg P, Elia M, Gómez JM et al. Composition of the ESPEN Working Group. Bioelectrical impedance analysis-part II: utilization in clinical practice. Clin Nutr 2004; 23: 1430-1453.
    • (2004) Clin Nutr , vol.23 , pp. 1430-1453
    • Kyle, U.G.1    Bosaeus, I.2    De Lorenzo, A.D.3    Deurenberg, P.4    Elia, M.5    Gómez, J.M.6
  • 7
    • 79551510129 scopus 로고    scopus 로고
    • Assessment of body composition in peritoneal dialysis patients using bioelectrical impedance and dual-energy X-ray absorptiometry
    • Fürstenberg A, Davenport A. Assessment of body composition in peritoneal dialysis patients using bioelectrical impedance and dual-energy X-ray absorptiometry. Am J Nephrol 2011; 33: 150-156.
    • (2011) Am J Nephrol , vol.33 , pp. 150-156
    • Fürstenberg, A.1    Davenport, A.2
  • 8
    • 84873439859 scopus 로고    scopus 로고
    • Does peritoneal dialysate affect body composition assessments using multi-frequency bioimpedance in peritoneal dialysis patients
    • Davenport A. Does peritoneal dialysate affect body composition assessments using multi-frequency bioimpedance in peritoneal dialysis patients? Eur J Clin Nutr 2013; 67: 223-225.
    • (2013) Eur J Clin Nutr , vol.67 , pp. 223-225
    • Davenport, A.1
  • 9
  • 10
    • 77956089743 scopus 로고    scopus 로고
    • Do changes in relative blood volume monitoring correlate to haemodialysis-associated hypotension
    • Booth J, Pinney J, Davenport A. Do changes in relative blood volume monitoring correlate to haemodialysis-associated hypotension? Nephron Clin Pract 2011; 117: c179-c183.
    • (2011) Nephron Clin Pract , vol.117 , pp. c179-c183
    • Booth, J.1    Pinney, J.2    Davenport, A.3
  • 11
    • 74049133996 scopus 로고    scopus 로고
    • Comparison of fluid status in patients treated by different modalities of peritoneal dialysis using multi-frequency bioimpedance
    • Davenport A, Willicombe M. Comparison of fluid status in patients treated by different modalities of peritoneal dialysis using multi-frequency bioimpedance. Int J Artif Organs 2009; 32: 779-786.
    • (2009) Int J Artif Organs , vol.32 , pp. 779-786
    • Davenport, A.1    Willicombe, M.2
  • 12
    • 78149298714 scopus 로고    scopus 로고
    • Dialyzers designed to increase internal filtration do not result in significantly increased platelet activation and thrombin generation
    • Vernon K, Peasegood J, Riddell A, Davenport A. Dialyzers designed to increase internal filtration do not result in significantly increased platelet activation and thrombin generation. Nephron Clin Pract 2011; 117: c403-c408.
    • (2011) Nephron Clin Pract , vol.117 , pp. c403-c408
    • Vernon, K.1    Peasegood, J.2    Riddell, A.3    Davenport, A.4
  • 13
    • 68349096347 scopus 로고    scopus 로고
    • Low-molecular-weight heparin as an alternative anticoagulant to unfractionated heparin for routine outpatient haemodialysis treatments
    • Davenport A. Low-molecular-weight heparin as an alternative anticoagulant to unfractionated heparin for routine outpatient haemodialysis treatments. Nephrology 2009; 14: 455-461.
    • (2009) Nephrology , vol.14 , pp. 455-461
    • Davenport, A.1
  • 14
    • 67649859229 scopus 로고    scopus 로고
    • Interdialytic weight gain in diabetic haemodialysis patients and diabetic control as assessed by glycated haemoglobin
    • Davenport A. Interdialytic weight gain in diabetic haemodialysis patients and diabetic control as assessed by glycated haemoglobin. Nephron Clin Pract 2009; 113: c33-c37.
    • (2009) Nephron Clin Pract , vol.113 , pp. c33-c37
    • Davenport, A.1
  • 15
    • 84863772082 scopus 로고    scopus 로고
    • Weight gains and increased blood pressure in outpatient haemodialysis patients due to change in acid dialysate concentrate supplier
    • Sandhu E, Crawford C, Davenport A. Weight gains and increased blood pressure in outpatient haemodialysis patients due to change in acid dialysate concentrate supplier. Int J Artif Organs 2012; 35: 642-647.
    • (2012) Int J Artif Organs , vol.35 , pp. 642-647
    • Sandhu, E.1    Crawford, C.2    Davenport, A.3
  • 16
    • 78650523951 scopus 로고    scopus 로고
    • Comparison of multifrequency bioelectrical impedance analysis and dual-energy X-ray absorptiometry assessments in outpatient haemodialysis patients
    • Fürstenberg A, Davenport A. Comparison of multifrequency bioelectrical impedance analysis and dual-energy X-ray absorptiometry assessments in outpatient haemodialysis patients. Am J Kidney Dis 2011; 57: 123-129.
    • (2011) Am J Kidney Dis , vol.57 , pp. 123-129
    • Fürstenberg, A.1    Davenport, A.2
  • 17
    • 84877862191 scopus 로고    scopus 로고
    • Comparison of bioimpedance and dual-energy X-ray absorptiometry for measurement of fat mass in haemodialysis patients
    • Molfino A, Don BR, Kaysen GA. Comparison of bioimpedance and dual-energy X-ray absorptiometry for measurement of fat mass in haemodialysis patients. Nephron Clin Pract 2012; 122: 127-133.
    • (2012) Nephron Clin Pract , vol.122 , pp. 127-133
    • Molfino, A.1    Don, B.R.2    Kaysen, G.A.3
  • 18
    • 84885353198 scopus 로고    scopus 로고
    • Nutritional status and overhydration: Can bioimpedance spectroscopy be useful in haemodialysis patients
    • Garagarza C, Joaõ-Matias P, Sousa-Guerreiro C, Amaral T, Aires I, Ferreira C et al. Nutritional status and overhydration: can bioimpedance spectroscopy be useful in haemodialysis patients? Nefrologia 2013; 33: 667-674.
    • (2013) Nefrologia , vol.33 , pp. 667-674
    • Garagarza, C.1    Joaõ-Matias, P.2    Sousa-Guerreiro, C.3    Amaral, T.4    Aires, I.5    Ferreira, C.6
  • 20
    • 0037357168 scopus 로고    scopus 로고
    • Influence of fluid status on techniques used to assess body composition in peritoneal dialysis patients
    • Konings CJ, Kooman JP, Schonck M, van Kreel B, Heidendal GA, Cheriex EC et al. Influence of fluid status on techniques used to assess body composition in peritoneal dialysis patients. Perit Dial Int 2003; 23: 184-190.
    • (2003) Perit Dial Int , vol.23 , pp. 184-190
    • Konings, C.J.1    Kooman, J.P.2    Schonck, M.3    Van Kreel, B.4    Heidendal, G.A.5    Cheriex, E.C.6
  • 21
    • 84868195124 scopus 로고    scopus 로고
    • Comparison of volume status in asymptomatic haemodialysis and peritoneal dialysis outpatients
    • Papakrivopoulou E, Booth J, Pinney J, Davenport A. Comparison of volume status in asymptomatic haemodialysis and peritoneal dialysis outpatients. Nephron Extra 2012; 2: 48-54.
    • (2012) Nephron Extra , vol.2 , pp. 48-54
    • Papakrivopoulou, E.1    Booth, J.2    Pinney, J.3    Davenport, A.4
  • 22
    • 78650663879 scopus 로고    scopus 로고
    • The effect of vascular access modality on changes in fluid content in the arms as determined by multifrequency bioimpedance
    • Booth J, Pinney J, Davenport A. The effect of vascular access modality on changes in fluid content in the arms as determined by multifrequency bioimpedance. Nephrol Dial Transplant 2011; 26: 227-231.
    • (2011) Nephrol Dial Transplant , vol.26 , pp. 227-231
    • Booth, J.1    Pinney, J.2    Davenport, A.3
  • 23
    • 84875657714 scopus 로고    scopus 로고
    • Changes in upper limb extracellular water content during hemodialysis measured by multi-frequency bioimpedance
    • Kumar S, Khosravi M, Massart A, Potluri M, Davenport A. Changes in upper limb extracellular water content during hemodialysis measured by multi-frequency bioimpedance. Int J Artif Organs 2013; 36: 203-207.
    • (2013) Int J Artif Organs , vol.36 , pp. 203-207
    • Kumar, S.1    Khosravi, M.2    Massart, A.3    Potluri, M.4    Davenport, A.5
  • 24
    • 84868159566 scopus 로고    scopus 로고
    • Quantifying acute changes in volume and nutritional status during haemodialysis using bioimpedance analysis
    • Chua HR, Xiang L, Chow PY, Xu H, Shen L, Lee E et al. Quantifying acute changes in volume and nutritional status during haemodialysis using bioimpedance analysis. Nephrology 2012; 17: 695-702.
    • (2012) Nephrology , vol.17 , pp. 695-702
    • Chua, H.R.1    Xiang, L.2    Chow, P.Y.3    Xu, H.4    Shen, L.5    Lee, E.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.