메뉴 건너뛰기




Volumn 122, Issue 3-4, 2012, Pages 127-133

Comparison of bioimpedance and dual-energy X-ray absorptiometry for measurement of fat mass in hemodialysis patients

Author keywords

Body composition; Extracellular water; Fat mass; Hemodialysis; Intracellular water

Indexed keywords

ADIPOSE TISSUE; ADULT; COMPARATIVE STUDY; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; HUMAN; IMPEDANCE PLETHYSMOGRAPHY; KIDNEY FAILURE, CHRONIC; MALE; MIDDLE AGED; OBESITY; PATHOPHYSIOLOGY; PHOTON ABSORPTIOMETRY; PROCEDURES; RENAL REPLACEMENT THERAPY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; TREATMENT OUTCOME;

EID: 84877862191     PISSN: None     EISSN: 16602110     Source Type: Journal    
DOI: 10.1159/000350817     Document Type: Article
Times cited : (22)

References (26)
  • 3
    • 84857032765 scopus 로고    scopus 로고
    • Effect of kidney failure and hemodialysis on protein and amino acid metabolism
    • Garibotto G, Bonanni A, Verzola D: Effect of kidney failure and hemodialysis on protein and amino acid metabolism. Curr Opin Clin Nutr Metab Care 2012; 15: 78-84
    • (2012) Curr Opin Clin Nutr Metab Care , vol.15 , pp. 78-84
    • Garibotto, G.1    Bonanni, A.2    Verzola, D.3
  • 4
    • 0025300470 scopus 로고
    • Nutritional assessment with body composition measurements by multiple isotope dilution
    • Shizgal HM: Nutritional assessment with body composition measurements by multiple isotope dilution. Infusionstherapie 1990; 17: 9-17
    • (1990) Infusionstherapie , vol.17 , pp. 9-17
    • Shizgal, H.M.1
  • 5
    • 0018373941 scopus 로고
    • A review of body composition studies with emphasis on total body water and fat
    • Sheng HP, Huggins RA: A review of body composition studies with emphasis on total body water and fat. Am J Clin Nutr 1979; 32: 630-647
    • (1979) Am J Clin Nutr , vol.32 , pp. 630-647
    • Sheng, H.P.1    Huggins, R.A.2
  • 6
    • 0002237630 scopus 로고    scopus 로고
    • Hydrometry
    • Roche AF, Heymsfield SB, Lohman TG (eds).Champaign, Human Kinetics
    • Schoeller DA: Hydrometry; in Roche AF, Heymsfield SB, Lohman TG (eds): Human Body Composition. Champaign, Human Kinetics, 1996, pp 25-44
    • (1996) Human Body Composition , pp. 25-44
    • Schoeller, D.A.1
  • 8
    • 17044442952 scopus 로고
    • Reference man and woman more fully characterized: Validations on the basis of body size, age, and race
    • Ellis KJ: Reference man and woman more fully characterized: validations on the basis of body size, age, and race. Biol Trace Elem Res 1990; 26-27: 385-400
    • (1990) Biol Trace Elem Res , vol.26-27 , pp. 385-400
    • Ellis, K.J.1
  • 10
    • 0029739472 scopus 로고    scopus 로고
    • Why bioelectrical impedance analysis should be used for estimating adiposity
    • Houtkooper LB, Lohman TG, Going SB, Howell WH: Why bioelectrical impedance analysis should be used for estimating adiposity. Am J Clin Nutr 1996; 64: 436-448
    • (1996) Am J Clin Nutr , vol.64 , pp. 436-448
    • Houtkooper, L.B.1    Lohman, T.G.2    Going, S.B.3    Howell, W.H.4
  • 11
    • 0029804636 scopus 로고    scopus 로고
    • Measurement of total body water by bioelectrical impedance in chronic renal failure
    • Woodrow G, Oldroyd B, Turney JH, Day JME, Smith MA: Measurement of total body water by bioelectrical impedance in chronic renal failure. Eur J Clin Nutr 1996; 50: 676-681
    • (1996) Eur J Clin Nutr , vol.50 , pp. 676-681
    • Woodrow, G.1    Oldroyd, B.2    Turney, J.H.3    Day, J.M.E.4    Smith, M.A.5
  • 12
    • 0026592162 scopus 로고
    • Total body water measured by bioelectrical impedance in patients after hemodialysis: Comparison with urea kinetics
    • Pastan S, Gassensmith C: Total body water measured by bioelectrical impedance in patients after hemodialysis: comparison with urea kinetics. ASAIO J 1992; 98:M186-M189
    • (1992) ASAIO J , vol.98 , pp. M186-M189
    • Pastan, S.1    Gassensmith, C.2
  • 16
    • 0028881307 scopus 로고
    • Comparision of bio-impedance spectroscopy and multi-frequency bioimpedance analysis for the assessment of extracellular and total body water in surgical patients
    • Hannan WJ, Cowen SJ, Plester CE, Fearon KCH, DeBeau A: Comparision of bio-impedance spectroscopy and multi-frequency bioimpedance analysis for the assessment of extracellular and total body water in surgical patients. Clin Sci 1995; 89: 651-658
    • (1995) Clin Sci , vol.89 , pp. 651-658
    • Hannan, W.J.1    Cowen, S.J.2    Plester, C.E.3    Fearon, K.C.H.4    Debeau, A.5
  • 17
    • 84864005096 scopus 로고    scopus 로고
    • Comparison of bioimpedance methods for estimating total body water and intracellular water changes during hemodialysis
    • Dou Y, Liu L, Cheng X, Cao L, Zuo L: Comparison of bioimpedance methods for estimating total body water and intracellular water changes during hemodialysis. Nephrol Dial Transplant 2011; 26: 3319-3324
    • (2011) Nephrol Dial Transplant , vol.26 , pp. 3319-3324
    • Dou, Y.1    Liu, L.2    Cheng, X.3    Cao, L.4    Zuo, L.5
  • 23
    • 16744363493 scopus 로고
    • Body water compartments with human aging using fat-free mass as the reference standard
    • Lesser GT, Markofsky J: Body water compartments with human aging using fat-free mass as the reference standard. Am J Physiol 1979; 236:R215-R220
    • (1979) Am J Physiol , vol.236 , pp. R215-R220
    • Lesser, G.T.1    Markofsky, J.2
  • 25


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.