메뉴 건너뛰기




Volumn 41, Issue 5, 2015, Pages 469-480

Clinician-performed ultrasound in hemodynamic and cardiac assessment: a synopsis of current indications and limitations

Author keywords

Echocardiography; Hemodynamic assessment; Inferior vena cava collapsibility index (IVC CI); Intravascular volume estimation; Point of care testing; Ultrasound

Indexed keywords

CLINICAL MEDICINE; ECHOGRAPHY; ELECTROCARDIOGRAPHY; ESOPHAGUS; HEART DISEASE; HEMODYNAMICS; HUMAN; INFERIOR CAVA VEIN; INTERVENTIONAL ULTRASONOGRAPHY; PATHOPHYSIOLOGY; PHYSIOLOGY; POINT OF CARE SYSTEM; PROCEDURES;

EID: 84943354150     PISSN: 18639933     EISSN: 16153146     Source Type: Journal    
DOI: 10.1007/s00068-014-0492-6     Document Type: Review
Times cited : (18)

References (122)
  • 1
    • 38449087991 scopus 로고    scopus 로고
    • Intensivist bedside ultrasound (INBU) for volume assessment in the intensive care unit: a pilot study
    • PID: 18073592, (discussion 500–2)
    • Carr BG, et al. Intensivist bedside ultrasound (INBU) for volume assessment in the intensive care unit: a pilot study. J Trauma. 2007;63(3):495–500 (discussion 500–2).
    • (2007) J Trauma , vol.63 , Issue.3 , pp. 495-500
    • Carr, B.G.1
  • 2
    • 84943350224 scopus 로고    scopus 로고
    • Two methods of hemodynamic and volume status assessment in critically ill patients: a study of disagreement
    • Eiferman DS, et al. Two methods of hemodynamic and volume status assessment in critically ill patients: a study of disagreement. J Intensive Care Med. 2014.
    • (2014) J Intensive Care Med
    • Eiferman, D.S.1
  • 3
    • 0014555550 scopus 로고
    • Evaluation of thoracic impedance plethysmography as an indicator of stroke volume in man
    • COI: 1:STN:280:DyaF1M3nsFSrtQ%3D%3D, PID: 4240999
    • Bache RJ, Harley A, Greenfield JC Jr. Evaluation of thoracic impedance plethysmography as an indicator of stroke volume in man. Am J Med Sci. 1969;258(2):100–13.
    • (1969) Am J Med Sci , vol.258 , Issue.2 , pp. 100-113
    • Bache, R.J.1    Harley, A.2    Greenfield, J.C.3
  • 4
    • 73649094401 scopus 로고    scopus 로고
    • Complications associated with pulmonary artery catheters: a comprehensive clinical review
    • COI: 1:STN:280:DC%2BC3c7nsVWrtw%3D%3D, PID: 20218415
    • Evans DC, et al. Complications associated with pulmonary artery catheters: a comprehensive clinical review. Scand J Surg. 2009;98(4):199–208.
    • (2009) Scand J Surg , vol.98 , Issue.4 , pp. 199-208
    • Evans, D.C.1
  • 5
    • 84855817728 scopus 로고    scopus 로고
    • Clinical review: update on hemodynamic monitoring—a consensus of 16
    • PID: 21884645
    • Vincent JL, et al. Clinical review: update on hemodynamic monitoring—a consensus of 16. Crit Care. 2011;15(4):229.
    • (2011) Crit Care , vol.15 , Issue.4 , pp. 229
    • Vincent, J.L.1
  • 6
    • 84897067499 scopus 로고    scopus 로고
    • Prospective evaluation of intravascular volume status in critically ill patients: does inferior vena cava collapsibility correlate with central venous pressure?
    • PID: 24662857, (discussion 963–4)
    • Stawicki SP, et al. Prospective evaluation of intravascular volume status in critically ill patients: does inferior vena cava collapsibility correlate with central venous pressure? J Trauma Acute Care Surg. 2014;76(4):956–63 (discussion 963–4).
    • (2014) J Trauma Acute Care Surg , vol.76 , Issue.4 , pp. 956-963
    • Stawicki, S.P.1
  • 7
    • 67349286164 scopus 로고    scopus 로고
    • Intensivist use of hand-carried ultrasonography to measure IVC collapsibility in estimating intravascular volume status: correlations with CVP
    • PID: 19651063
    • Stawicki SP, et al. Intensivist use of hand-carried ultrasonography to measure IVC collapsibility in estimating intravascular volume status: correlations with CVP. J Am Coll Surg. 2009;209(1):55–61.
    • (2009) J Am Coll Surg , vol.209 , Issue.1 , pp. 55-61
    • Stawicki, S.P.1
  • 8
    • 36048929960 scopus 로고    scopus 로고
    • Exploring measurement biases associated with esophageal Doppler monitoring in critically ill patients in intensive care unit
    • PID: 19727365
    • Stawicki PS, Braslow B, Gracias VH. Exploring measurement biases associated with esophageal Doppler monitoring in critically ill patients in intensive care unit. Ann Thorac Med. 2007;2(4):148–53.
    • (2007) Ann Thorac Med , vol.2 , Issue.4 , pp. 148-153
    • Stawicki, P.S.1    Braslow, B.2    Gracias, V.H.3
  • 9
    • 33746569667 scopus 로고    scopus 로고
    • Hemodynamic monitoring of organ donors: a novel use of the esophageal echo-Doppler probe
    • PID: 16808202
    • Cipolla J, Stawicki S, Spatz D. Hemodynamic monitoring of organ donors: a novel use of the esophageal echo-Doppler probe. Am Surg. 2006;72(6):500–4.
    • (2006) Am Surg , vol.72 , Issue.6 , pp. 500-504
    • Cipolla, J.1    Stawicki, S.2    Spatz, D.3
  • 10
    • 27844463495 scopus 로고    scopus 로고
    • Use of non-invasive esophageal echo-Doppler system in the ICU: a practical experience
    • PID: 16294103
    • Stawicki SP, et al. Use of non-invasive esophageal echo-Doppler system in the ICU: a practical experience. J Trauma. 2005;59(2):506–7.
    • (2005) J Trauma , vol.59 , Issue.2 , pp. 506-507
    • Stawicki, S.P.1
  • 11
    • 44349104862 scopus 로고    scopus 로고
    • Transthoracic echocardiography for suspected pulmonary embolism in the intensive care unit: unjustly underused or rightfully ignored?
    • PID: 18361466
    • Stawicki SP, et al. Transthoracic echocardiography for suspected pulmonary embolism in the intensive care unit: unjustly underused or rightfully ignored? J Clin Ultrasound. 2008;36(5):291–302.
    • (2008) J Clin Ultrasound , vol.36 , Issue.5 , pp. 291-302
    • Stawicki, S.P.1
  • 12
    • 37249011851 scopus 로고    scopus 로고
    • Transthoracic echocardiography for pulmonary embolism in the ICU: finding the “right” findings
    • PID: 18155567
    • Stawicki SP, et al. Transthoracic echocardiography for pulmonary embolism in the ICU: finding the “right” findings. J Am Coll Surg. 2008;206(1):42–7.
    • (2008) J Am Coll Surg , vol.206 , Issue.1 , pp. 42-47
    • Stawicki, S.P.1
  • 13
    • 77953109768 scopus 로고    scopus 로고
    • Focused transthoracic echocardiography
    • PID: 20463434
    • Khasawneh FA, Smalligan RD. Focused transthoracic echocardiography. Postgrad Med. 2010;122(3):230–7.
    • (2010) Postgrad Med , vol.122 , Issue.3 , pp. 230-237
    • Khasawneh, F.A.1    Smalligan, R.D.2
  • 14
    • 84873413929 scopus 로고    scopus 로고
    • Ultrasound-assisted musculoskeletal procedures: a practical overview of current literature
    • PID: 22474637
    • Royall NA, et al. Ultrasound-assisted musculoskeletal procedures: a practical overview of current literature. World J Orthop. 2011;2(7):57–66.
    • (2011) World J Orthop , vol.2 , Issue.7 , pp. 57-66
    • Royall, N.A.1
  • 15
    • 84885486018 scopus 로고    scopus 로고
    • Evidence tables: inferior vena cava collapsibility index (IVC-CI). OPUS 12
    • Stawicki SP, Bahner DP. Evidence tables: inferior vena cava collapsibility index (IVC-CI). OPUS 12. Scientist. 2012;6(1):3–5.
    • (2012) Scientist , vol.6 , Issue.1 , pp. 3-5
    • Stawicki, S.P.1    Bahner, D.P.2
  • 16
    • 79951960871 scopus 로고    scopus 로고
    • Point-of-care ultrasonography
    • COI: 1:CAS:528:DC%2BC3MXis1ymsbs%3D, PID: 21345104
    • Moore CL, Copel JA. Point-of-care ultrasonography. N Engl J Med. 2011;364(8):749–57.
    • (2011) N Engl J Med , vol.364 , Issue.8 , pp. 749-757
    • Moore, C.L.1    Copel, J.A.2
  • 17
    • 84856727734 scopus 로고    scopus 로고
    • I-AIM: a novel model for teaching and performing focused sonography
    • PID: 22298874
    • Bahner DP, Hughes D, Royall NA. I-AIM: a novel model for teaching and performing focused sonography. J Ultrasound Med. 2012;31(2):295–300.
    • (2012) J Ultrasound Med , vol.31 , Issue.2 , pp. 295-300
    • Bahner, D.P.1    Hughes, D.2    Royall, N.A.3
  • 18
    • 84897102474 scopus 로고    scopus 로고
    • What’s new in critical illness and injury science? The challenge of verifying tracheal airway placement: solving the puzzle one piece at a time
    • PID: 23961453
    • Bahner DP, et al. What’s new in critical illness and injury science? The challenge of verifying tracheal airway placement: solving the puzzle one piece at a time. Int J Crit Illn Inj Sci. 2013;3(2):105–7.
    • (2013) Int J Crit Illn Inj Sci , vol.3 , Issue.2 , pp. 105-107
    • Bahner, D.P.1
  • 19
    • 0035117111 scopus 로고    scopus 로고
    • Real-time sonography for screening of gallbladder dysfunction in children with type 1 diabetes mellitus
    • COI: 1:STN:280:DC%2BD3M3jtlGitg%3D%3D, PID: 11220707
    • Arslanoglu I, et al. Real-time sonography for screening of gallbladder dysfunction in children with type 1 diabetes mellitus. J Pediatr Endocrinol Metab. 2001;14(1):61–9.
    • (2001) J Pediatr Endocrinol Metab , vol.14 , Issue.1 , pp. 61-69
    • Arslanoglu, I.1
  • 20
    • 18144391528 scopus 로고    scopus 로고
    • Sonography as the primary screening method in evaluating blunt abdominal trauma
    • PID: 15856519
    • Bakker J, et al. Sonography as the primary screening method in evaluating blunt abdominal trauma. J Clin Ultrasound. 2005;33(4):155–63.
    • (2005) J Clin Ultrasound , vol.33 , Issue.4 , pp. 155-163
    • Bakker, J.1
  • 21
    • 0028295776 scopus 로고
    • Value of high resolution sonography in breast cancer screening
    • COI: 1:STN:280:DyaK2c3hvVOjtw%3D%3D, PID: 8165458
    • Madjar H, et al. Value of high resolution sonography in breast cancer screening. Ultraschall Med. 1994;15(1):20–3.
    • (1994) Ultraschall Med , vol.15 , Issue.1 , pp. 20-23
    • Madjar, H.1
  • 22
    • 82455188566 scopus 로고    scopus 로고
    • Screening for carpal tunnel syndrome using sonography
    • PID: 22124001
    • Roll SC, et al. Screening for carpal tunnel syndrome using sonography. J Ultrasound Med. 2011;30(12):1657–67.
    • (2011) J Ultrasound Med , vol.30 , Issue.12 , pp. 1657-1667
    • Roll, S.C.1
  • 23
    • 78449282979 scopus 로고    scopus 로고
    • Supplementary screening sonography in mammographically dense breast: pros and cons
    • PID: 21076583
    • Youk JH, Kim EK. Supplementary screening sonography in mammographically dense breast: pros and cons. Korean J Radiol. 2010;11(6):589–93.
    • (2010) Korean J Radiol , vol.11 , Issue.6 , pp. 589-593
    • Youk, J.H.1    Kim, E.K.2
  • 24
    • 0033022369 scopus 로고    scopus 로고
    • Ultrasound-guided central venous access
    • COI: 1:STN:280:DyaK1MzivVamsA%3D%3D, PID: 10401825, (discussion 741)
    • Fry WR, Clagett GC, O’Rourke PT. Ultrasound-guided central venous access. Arch Surg. 1999;134(7):738–40 (discussion 741).
    • (1999) Arch Surg , vol.134 , Issue.7 , pp. 738-740
    • Fry, W.R.1    Clagett, G.C.2    O’Rourke, P.T.3
  • 25
    • 0026081988 scopus 로고
    • An ultrasound method for safe and rapid central venous access
    • COI: 1:STN:280:DyaK3M7isFChsA%3D%3D, PID: 1992315
    • Denys BG, et al. An ultrasound method for safe and rapid central venous access. N Engl J Med. 1991;324(8):566.
    • (1991) N Engl J Med , vol.324 , Issue.8 , pp. 566
    • Denys, B.G.1
  • 26
    • 84880532489 scopus 로고    scopus 로고
    • Portable ultrasonography in mass casualty incidents: the CAVEAT examination
    • PID: 22474622
    • Stawicki SP, et al. Portable ultrasonography in mass casualty incidents: the CAVEAT examination. World J Orthop. 2010;1(1):10–9.
    • (2010) World J Orthop , vol.1 , Issue.1 , pp. 10-19
    • Stawicki, S.P.1
  • 27
    • 52149104317 scopus 로고    scopus 로고
    • FAST scan: ultrasound’s role in trauma
    • PID: 18487465
    • Cunningham AR. FAST scan: ultrasound’s role in trauma. Radiol Technol. 2008;79(5):455–8.
    • (2008) Radiol Technol , vol.79 , Issue.5 , pp. 455-458
    • Cunningham, A.R.1
  • 28
    • 62749089612 scopus 로고    scopus 로고
    • Evidence-based emergency medicine/systematic review abstract. The FAST scan: are we improving care of the trauma patient?
    • PID: 17328105
    • Vance S. Evidence-based emergency medicine/systematic review abstract. The FAST scan: are we improving care of the trauma patient? Ann Emerg Med. 2007;49(3):364–6.
    • (2007) Ann Emerg Med , vol.49 , Issue.3 , pp. 364-366
    • Vance, S.1
  • 30
    • 84899911053 scopus 로고    scopus 로고
    • Lung ultrasound for the diagnosis of pneumonia in adults: a systematic review and meta-analysis
    • PID: 24758612
    • Chavez MA, et al. Lung ultrasound for the diagnosis of pneumonia in adults: a systematic review and meta-analysis. Respir Res. 2014;15:50.
    • (2014) Respir Res , vol.15 , pp. 50
    • Chavez, M.A.1
  • 31
    • 4544298817 scopus 로고    scopus 로고
    • Hand-carried ultrasound improves the bedside cardiovascular examination
    • PID: 15364744
    • Kobal SL, Atar S, Siegel RJ. Hand-carried ultrasound improves the bedside cardiovascular examination. Chest. 2004;126(3):693–701.
    • (2004) Chest , vol.126 , Issue.3 , pp. 693-701
    • Kobal, S.L.1    Atar, S.2    Siegel, R.J.3
  • 32
    • 0030746220 scopus 로고    scopus 로고
    • Emergency obstetric and gynecologic ultrasound
    • COI: 1:STN:280:DyaK2szlvFOitA%3D%3D, PID: 9216632
    • Estroff JA. Emergency obstetric and gynecologic ultrasound. Radiol Clin North Am. 1997;35(4):921–57.
    • (1997) Radiol Clin North Am , vol.35 , Issue.4 , pp. 921-957
    • Estroff, J.A.1
  • 33
    • 0024450286 scopus 로고
    • Transvaginal sonography as a screening method for ovarian cancer
    • COI: 1:STN:280:DyaL1MzlslKgug%3D%3D, PID: 2670695
    • Higgins RV, et al. Transvaginal sonography as a screening method for ovarian cancer. Gynecol Oncol. 1989;34(3):402–6.
    • (1989) Gynecol Oncol , vol.34 , Issue.3 , pp. 402-406
    • Higgins, R.V.1
  • 34
    • 84897799072 scopus 로고    scopus 로고
    • Prospective advancements in ultrasound imaging
    • PID: 24614441
    • McGuire J, Wood BD. Prospective advancements in ultrasound imaging. Radiol Technol. 2014;85(4):463–6.
    • (2014) Radiol Technol , vol.85 , Issue.4 , pp. 463-466
    • McGuire, J.1    Wood, B.D.2
  • 35
    • 78651445215 scopus 로고    scopus 로고
    • High intensity focused ultrasound in clinical tumor ablation
    • PID: 21603311
    • Zhou YF. High intensity focused ultrasound in clinical tumor ablation. World J Clin Oncol. 2011;2(1):8–27.
    • (2011) World J Clin Oncol , vol.2 , Issue.1 , pp. 8-27
    • Zhou, Y.F.1
  • 36
    • 33947184832 scopus 로고    scopus 로고
    • Hemorrhage control using high intensity focused ultrasound
    • PID: 17578344
    • Vaezy S, Zderic V. Hemorrhage control using high intensity focused ultrasound. Int J Hyperthermia. 2007;23(2):203–11.
    • (2007) Int J Hyperthermia , vol.23 , Issue.2 , pp. 203-211
    • Vaezy, S.1    Zderic, V.2
  • 37
    • 5344277479 scopus 로고    scopus 로고
    • Low-intensity transosseous ultrasound accelerates osteotomy healing in a sheep fracture model
    • PID: 15466739
    • Hantes ME, et al. Low-intensity transosseous ultrasound accelerates osteotomy healing in a sheep fracture model. J Bone Joint Surg Am. 2004;86-A(10):2275–82.
    • (2004) J Bone Joint Surg Am , vol.86-A , Issue.10 , pp. 2275-2282
    • Hantes, M.E.1
  • 38
    • 85133615529 scopus 로고    scopus 로고
    • Fracture healing using low-intensity pulsed ultrasound
    • PID: 12160117, (author reply 128)
    • McAlinden MM. Fracture healing using low-intensity pulsed ultrasound. CMAJ. 2002;167(2):128 (author reply 128).
    • (2002) CMAJ , vol.167 , Issue.2 , pp. 128
    • McAlinden, M.M.1
  • 39
    • 53749084146 scopus 로고    scopus 로고
    • Expedited wound healing with noncontact, low-frequency ultrasound therapy in chronic wounds: a retrospective analysis
    • PID: 18769168
    • Kavros SJ, et al. Expedited wound healing with noncontact, low-frequency ultrasound therapy in chronic wounds: a retrospective analysis. Adv Skin Wound Care. 2008;21(9):416–23.
    • (2008) Adv Skin Wound Care , vol.21 , Issue.9 , pp. 416-423
    • Kavros, S.J.1
  • 40
    • 84943350348 scopus 로고    scopus 로고
    • Inferior vena cava diameters and collapsibility index changes reveal early volume depletion in a healthy donor model
    • Pasquero P, et al. Inferior vena cava diameters and collapsibility index changes reveal early volume depletion in a healthy donor model. Crit Ultrasound J. 2012;4(Suppl 1):A29.
    • (2012) Crit Ultrasound J , vol.4 , pp. A29
    • Pasquero, P.1
  • 41
    • 84876902375 scopus 로고    scopus 로고
    • Inferior vena cava diameter and collapsibility index: a practical non-invasive evaluation of intravascular fluid volume in critically-ill patients
    • PID: 23682518
    • Thanakitcharu P, Charoenwut M, Siriwiwatanakul N. Inferior vena cava diameter and collapsibility index: a practical non-invasive evaluation of intravascular fluid volume in critically-ill patients. J Med Assoc Thai. 2013;96(Suppl 3):S14–22.
    • (2013) J Med Assoc Thai , vol.96 , pp. S14-S22
    • Thanakitcharu, P.1    Charoenwut, M.2    Siriwiwatanakul, N.3
  • 42
    • 42649125592 scopus 로고    scopus 로고
    • Functional hemodynamic monitoring and dynamic indices of fluid responsiveness
    • COI: 1:STN:280:DC%2BD1c7pt1Cmsg%3D%3D, PID: 18212731
    • Cavallaro F, Sandroni C, Antonelli M. Functional hemodynamic monitoring and dynamic indices of fluid responsiveness. Minerva Anestesiol. 2008;74(4):123–35.
    • (2008) Minerva Anestesiol , vol.74 , Issue.4 , pp. 123-135
    • Cavallaro, F.1    Sandroni, C.2    Antonelli, M.3
  • 43
    • 84884675284 scopus 로고    scopus 로고
    • Sonographic evaluation of intravascular volume status in the surgical intensive care unit: a prospective comparison of subclavian vein and inferior vena cava collapsibility index
    • PID: 23764308
    • Kent A, et al. Sonographic evaluation of intravascular volume status in the surgical intensive care unit: a prospective comparison of subclavian vein and inferior vena cava collapsibility index. J Surg Res. 2013;184(1):561–6.
    • (2013) J Surg Res , vol.184 , Issue.1 , pp. 561-566
    • Kent, A.1
  • 44
    • 80052756032 scopus 로고    scopus 로고
    • Ultrasound does not detect early blood loss in healthy volunteers donating blood
    • PID: 21421294
    • Resnick J, et al. Ultrasound does not detect early blood loss in healthy volunteers donating blood. J Emerg Med. 2011;41(3):270–5.
    • (2011) J Emerg Med , vol.41 , Issue.3 , pp. 270-275
    • Resnick, J.1
  • 45
    • 70449631735 scopus 로고    scopus 로고
    • Diagnostic accuracy of a simple ultrasound measurement to estimate central venous pressure in spontaneously breathing, critically ill patients
    • PID: 19670356
    • Keller AS, et al. Diagnostic accuracy of a simple ultrasound measurement to estimate central venous pressure in spontaneously breathing, critically ill patients. J Hosp Med. 2009;4(6):350–5.
    • (2009) J Hosp Med , vol.4 , Issue.6 , pp. 350-355
    • Keller, A.S.1
  • 46
    • 84862911614 scopus 로고    scopus 로고
    • Correlation of internal jugular vein/common carotid artery ratio to central venous pressure: a pilot study in pediatric burn patients
    • PID: 22240508
    • Bailey JK, et al. Correlation of internal jugular vein/common carotid artery ratio to central venous pressure: a pilot study in pediatric burn patients. J Burn Care Res. 2012;33(1):89–92.
    • (2012) J Burn Care Res , vol.33 , Issue.1 , pp. 89-92
    • Bailey, J.K.1
  • 47
    • 78651413703 scopus 로고    scopus 로고
    • Ultrasound accurately reflects the jugular venous examination but underestimates central venous pressure
    • PID: 20798190
    • Deol GR, et al. Ultrasound accurately reflects the jugular venous examination but underestimates central venous pressure. Chest. 2011;139(1):95–100.
    • (2011) Chest , vol.139 , Issue.1 , pp. 95-100
    • Deol, G.R.1
  • 48
    • 77952543391 scopus 로고    scopus 로고
    • Inferior vena cava diameter correlates with invasive hemodynamic measures in mechanically ventilated intensive care unit patients with sepsis
    • PID: 18385005
    • Schefold JC, et al. Inferior vena cava diameter correlates with invasive hemodynamic measures in mechanically ventilated intensive care unit patients with sepsis. J Emerg Med. 2010;38(5):632–7.
    • (2010) J Emerg Med , vol.38 , Issue.5 , pp. 632-637
    • Schefold, J.C.1
  • 49
    • 20244370575 scopus 로고    scopus 로고
    • Feasibility and potential clinical utility of goal-directed transthoracic echocardiography performed by noncardiologist intensivists using a small hand-carried device (SonoHeart) in critically ill patients
    • PID: 15868520
    • Manasia AR, et al. Feasibility and potential clinical utility of goal-directed transthoracic echocardiography performed by noncardiologist intensivists using a small hand-carried device (SonoHeart) in critically ill patients. J Cardiothorac Vasc Anesth. 2005;19(2):155–9.
    • (2005) J Cardiothorac Vasc Anesth , vol.19 , Issue.2 , pp. 155-159
    • Manasia, A.R.1
  • 50
    • 67650317474 scopus 로고    scopus 로고
    • Accuracy of cardiac function and volume status estimates using the bedside echocardiographic assessment in trauma/critical care
    • PID: 18784562
    • Gunst M, et al. Accuracy of cardiac function and volume status estimates using the bedside echocardiographic assessment in trauma/critical care. J Trauma. 2008;65(3):509–16.
    • (2008) J Trauma , vol.65 , Issue.3 , pp. 509-516
    • Gunst, M.1
  • 51
    • 49749099240 scopus 로고    scopus 로고
    • Bedside echocardiographic assessment for trauma/critical care: the BEAT exam
    • PID: 18722929
    • Gunst M, et al. Bedside echocardiographic assessment for trauma/critical care: the BEAT exam. J Am Coll Surg. 2008;207(3):e1–3.
    • (2008) J Am Coll Surg , vol.207 , Issue.3 , pp. e1-e3
    • Gunst, M.1
  • 52
    • 84893043306 scopus 로고    scopus 로고
    • Intensivist use of hand-carried ultrasound to measure E/E’ and IVC collapsibility in estimating volume status: correlations with pulmonary artery and central venous pressures
    • Stawicki SP, et al. Intensivist use of hand-carried ultrasound to measure E/E’ and IVC collapsibility in estimating volume status: correlations with pulmonary artery and central venous pressures. South Med J. 2008;101:861.
    • (2008) South Med J , vol.101 , pp. 861
    • Stawicki, S.P.1
  • 53
    • 66649121675 scopus 로고    scopus 로고
    • Assessment of left ventricular function by intensivists using hand-held echocardiography
    • PID: 19225055
    • Melamed R, et al. Assessment of left ventricular function by intensivists using hand-held echocardiography. Chest. 2009;135(6):1416–20.
    • (2009) Chest , vol.135 , Issue.6 , pp. 1416-1420
    • Melamed, R.1
  • 54
    • 0036112315 scopus 로고    scopus 로고
    • Utility of esophageal Doppler as a minimally invasive hemodynamic monitor: a review
    • PID: 11927480
    • Laupland KB, Bands CJ. Utility of esophageal Doppler as a minimally invasive hemodynamic monitor: a review. Can J Anaesth. 2002;49(4):393–401.
    • (2002) Can J Anaesth , vol.49 , Issue.4 , pp. 393-401
    • Laupland, K.B.1    Bands, C.J.2
  • 55
    • 0032814699 scopus 로고    scopus 로고
    • The clinical use of an esophageal Doppler monitor for hemodynamic monitoring in sepsis
    • COI: 1:STN:280:DC%2BD3s%2FlslemsA%3D%3D, PID: 12568174
    • Eachempati SR, et al. The clinical use of an esophageal Doppler monitor for hemodynamic monitoring in sepsis. J Clin Monit Comput. 1999;15(3–4):223–5.
    • (1999) J Clin Monit Comput , vol.15 , Issue.3-4 , pp. 223-225
    • Eachempati, S.R.1
  • 56
    • 0034303914 scopus 로고    scopus 로고
    • Newer trends in monitoring: the esophageal Doppler monitor
    • COI: 1:STN:280:DC%2BD38%2FjtlOlsw%3D%3D, PID: 11759127
    • Kauffman KE. Newer trends in monitoring: the esophageal Doppler monitor. AANA J. 2000;68(5):421–8.
    • (2000) AANA J , vol.68 , Issue.5 , pp. 421-428
    • Kauffman, K.E.1
  • 57
    • 0346048992 scopus 로고    scopus 로고
    • Placement of the esophageal Doppler ultrasound monitor probe in awake patients
    • COI: 1:STN:280:DC%2BD3M7lsF2isQ%3D%3D, PID: 11157636
    • Atlas G, Mort T. Placement of the esophageal Doppler ultrasound monitor probe in awake patients. Chest. 2001;119(1):319.
    • (2001) Chest , vol.119 , Issue.1 , pp. 319
    • Atlas, G.1    Mort, T.2
  • 58
    • 0032885401 scopus 로고    scopus 로고
    • Comparison of esophageal Doppler monitor generated minute distance and cardiac output in a porcine model of ventricular fibrillation
    • COI: 1:STN:280:DyaK1MvjsFGksg%3D%3D, PID: 10507713
    • Lichtenberger M, et al. Comparison of esophageal Doppler monitor generated minute distance and cardiac output in a porcine model of ventricular fibrillation. Resuscitation. 1999;41(3):269–76.
    • (1999) Resuscitation , vol.41 , Issue.3 , pp. 269-276
    • Lichtenberger, M.1
  • 59
    • 0033939067 scopus 로고    scopus 로고
    • Esophageal Doppler monitor determinations of cardiac output and preload during cardiac operations
    • COI: 1:STN:280:DC%2BD3czkvFSisA%3D%3D, PID: 10892923
    • DiCorte CJ, et al. Esophageal Doppler monitor determinations of cardiac output and preload during cardiac operations. Ann Thorac Surg. 2000;69(6):1782–6.
    • (2000) Ann Thorac Surg , vol.69 , Issue.6 , pp. 1782-1786
    • DiCorte, C.J.1
  • 60
    • 0242556407 scopus 로고    scopus 로고
    • Change in stroke volume in response to fluid challenge: assessment using esophageal Doppler
    • PID: 12684746
    • Roeck M, et al. Change in stroke volume in response to fluid challenge: assessment using esophageal Doppler. Intensive Care Med. 2003;29(10):1729–35.
    • (2003) Intensive Care Med , vol.29 , Issue.10 , pp. 1729-1735
    • Roeck, M.1
  • 61
    • 80052429884 scopus 로고    scopus 로고
    • Use of transesophageal Doppler as a sole cardiac output monitor for reperfusion hemodynamic changes during living donor liver transplantation: an observational study
    • COI: 1:STN:280:DC%2BC3Mfnt1Gisw%3D%3D, PID: 21957404
    • Hussien M, et al. Use of transesophageal Doppler as a sole cardiac output monitor for reperfusion hemodynamic changes during living donor liver transplantation: an observational study. Saudi J Anaesth. 2011;5(3):264–9.
    • (2011) Saudi J Anaesth , vol.5 , Issue.3 , pp. 264-269
    • Hussien, M.1
  • 62
    • 33644972521 scopus 로고    scopus 로고
    • Esophageal Doppler monitoring during organ donor resuscitation: new benefits of existing technology
    • PID: 16477813
    • Stawicki SP, et al. Esophageal Doppler monitoring during organ donor resuscitation: new benefits of existing technology. Prog Transplant. 2005;15(4):320.
    • (2005) Prog Transplant , vol.15 , Issue.4 , pp. 320
    • Stawicki, S.P.1
  • 63
    • 67849110105 scopus 로고    scopus 로고
    • Perioperative hemodynamic monitoring with transesophageal Doppler technology
    • PID: 19608800
    • Schober P, Loer SA, Schwarte LA. Perioperative hemodynamic monitoring with transesophageal Doppler technology. Anesth Analg. 2009;109(2):340–53.
    • (2009) Anesth Analg , vol.109 , Issue.2 , pp. 340-353
    • Schober, P.1    Loer, S.A.2    Schwarte, L.A.3
  • 64
    • 33746291642 scopus 로고    scopus 로고
    • Hand-held echocardiography: its use and usefulness
    • PID: 16087257
    • Mondillo S, et al. Hand-held echocardiography: its use and usefulness. Int J Cardiol. 2006;111(1):1–5.
    • (2006) Int J Cardiol , vol.111 , Issue.1 , pp. 1-5
    • Mondillo, S.1
  • 65
    • 84943353059 scopus 로고    scopus 로고
    • August 15, 2014)
    • ImaCor, Inc. The hTEE approach. 2014 (cited 2014 August 15, 2014). Available from: http://imacorinc.com/htee/the-htee-approach.html.
    • (2014) Available from:
    • ImaCor, I.1
  • 66
    • 84878393268 scopus 로고    scopus 로고
    • Echo didactics: a comparison of basic transthoracic and transesophageal echocardiography views in the perioperative setting
    • PID: 23558842
    • Shillcutt SK, Bick JS. Echo didactics: a comparison of basic transthoracic and transesophageal echocardiography views in the perioperative setting. Anesth Analg. 2013;116(6):1231–6.
    • (2013) Anesth Analg , vol.116 , Issue.6 , pp. 1231-1236
    • Shillcutt, S.K.1    Bick, J.S.2
  • 67
    • 0018956627 scopus 로고
    • Clinical value and limitations of echocardiography. Its use in the study of patients with infectious endocarditis
    • COI: 1:STN:280:DyaL3c3ktFWisg%3D%3D, PID: 6994670
    • Mintz GS, Kotler MN. Clinical value and limitations of echocardiography. Its use in the study of patients with infectious endocarditis. Arch Intern Med. 1980;140(8):1022–7.
    • (1980) Arch Intern Med , vol.140 , Issue.8 , pp. 1022-1027
    • Mintz, G.S.1    Kotler, M.N.2
  • 68
    • 0019328359 scopus 로고
    • Value and limitations of two dimensional echocardiography in assessment of cardiomyopathy
    • COI: 1:STN:280:DyaL3M7gs1Giuw%3D%3D, PID: 6450529
    • DeMaria AN, et al. Value and limitations of two dimensional echocardiography in assessment of cardiomyopathy. Am J Cardiol. 1980;46(7):1224–31.
    • (1980) Am J Cardiol , vol.46 , Issue.7 , pp. 1224-1231
    • DeMaria, A.N.1
  • 69
    • 0021084098 scopus 로고
    • Value and limitations of contrast echocardiography in cardiac diagnosis
    • COI: 1:STN:280:DyaL3s3osFSmsg%3D%3D, PID: 6411339
    • DeMaria AN, et al. Value and limitations of contrast echocardiography in cardiac diagnosis. Cardiovasc Clin. 1983;13(3):167–79.
    • (1983) Cardiovasc Clin , vol.13 , Issue.3 , pp. 167-179
    • DeMaria, A.N.1
  • 70
    • 84874680776 scopus 로고    scopus 로고
    • Transoesophageal echocardiography related complications
    • COI: 1:STN:280:DC%2BC3cnotVKmsA%3D%3D, PID: 20640107
    • Mathur SK, Singh P. Transoesophageal echocardiography related complications. Indian J Anaesth. 2009;53(5):567–74.
    • (2009) Indian J Anaesth , vol.53 , Issue.5 , pp. 567-574
    • Mathur, S.K.1    Singh, P.2
  • 71
    • 33745697192 scopus 로고    scopus 로고
    • Transoesophageal echocardiography (TOE) in the operating room
    • COI: 1:STN:280:DC%2BD28zlsVyktg%3D%3D, PID: 16740605
    • Kneeshaw JD. Transoesophageal echocardiography (TOE) in the operating room. Br J Anaesth. 2006;97(1):77–84.
    • (2006) Br J Anaesth , vol.97 , Issue.1 , pp. 77-84
    • Kneeshaw, J.D.1
  • 72
    • 84907018181 scopus 로고    scopus 로고
    • Perioperative use of the imacor hemodynamic transesophageal echocardiography probe in cardiac surgery patients—initial experience
    • PID: 25010912
    • Sarosiek K, et al. Perioperative use of the imacor hemodynamic transesophageal echocardiography probe in cardiac surgery patients—initial experience. ASAIO J. 2014;60:553–8.
    • (2014) ASAIO J , vol.60 , pp. 553-558
    • Sarosiek, K.1
  • 73
    • 0041784903 scopus 로고    scopus 로고
    • ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography: summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASE Committee to Update the 1997 Guidelines for the Clinical Application of Echocardiography)
    • PID: 12952829
    • Cheitlin MD, et al. ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography: summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASE Committee to Update the 1997 Guidelines for the Clinical Application of Echocardiography). Circulation. 2003;108(9):1146–62.
    • (2003) Circulation , vol.108 , Issue.9 , pp. 1146-1162
    • Cheitlin, M.D.1
  • 74
    • 84903596832 scopus 로고    scopus 로고
    • Hemodynamic assessment in the contemporary intensive care unit: a review of circulatory monitoring devices
    • PID: 24996604
    • Kenaan M, Gajera M, Goonewardena SN. Hemodynamic assessment in the contemporary intensive care unit: a review of circulatory monitoring devices. Crit Care Clin. 2014;30(3):413–45.
    • (2014) Crit Care Clin , vol.30 , Issue.3 , pp. 413-445
    • Kenaan, M.1    Gajera, M.2    Goonewardena, S.N.3
  • 75
    • 8744306052 scopus 로고    scopus 로고
    • Transthoracic echocardiography to identify or exclude cardiac cause of shock
    • PID: 15539732
    • Joseph MX, et al. Transthoracic echocardiography to identify or exclude cardiac cause of shock. Chest. 2004;126(5):1592–7.
    • (2004) Chest , vol.126 , Issue.5 , pp. 1592-1597
    • Joseph, M.X.1
  • 76
    • 0037111275 scopus 로고    scopus 로고
    • Echo-Doppler demonstration of acute cor pulmonale at the bedside in the medical intensive care unit
    • PID: 12421740
    • Vieillard-Baron A, et al. Echo-Doppler demonstration of acute cor pulmonale at the bedside in the medical intensive care unit. Am J Respir Crit Care Med. 2002;166(10):1310–9.
    • (2002) Am J Respir Crit Care Med , vol.166 , Issue.10 , pp. 1310-1319
    • Vieillard-Baron, A.1
  • 77
    • 84893152004 scopus 로고    scopus 로고
    • Incidental findings on intensivist bedside ultrasonographic (INBU) examinations: why should we care? OPUS 12
    • Stawicki SP, et al. Incidental findings on intensivist bedside ultrasonographic (INBU) examinations: why should we care? OPUS 12. Scientist. 2008;2(3):11–4.
    • (2008) Scientist , vol.2 , Issue.3 , pp. 11-14
    • Stawicki, S.P.1
  • 78
    • 0036250831 scopus 로고    scopus 로고
    • Transesophageal echocardiography in critically ill patients
    • PID: 12006793
    • Colreavy FB, et al. Transesophageal echocardiography in critically ill patients. Crit Care Med. 2002;30(5):989–96.
    • (2002) Crit Care Med , vol.30 , Issue.5 , pp. 989-996
    • Colreavy, F.B.1
  • 79
    • 29844447114 scopus 로고    scopus 로고
    • Echocardiography in the critically ill: current and potential roles
    • COI: 1:STN:280:DC%2BD287ksVSitQ%3D%3D, PID: 16292626
    • Price S, et al. Echocardiography in the critically ill: current and potential roles. Intensive Care Med. 2006;32(1):48–59.
    • (2006) Intensive Care Med , vol.32 , Issue.1 , pp. 48-59
    • Price, S.1
  • 80
    • 0024560627 scopus 로고
    • Echocardiography in diagnosis of aortic dissection
    • COI: 1:STN:280:DyaL1M7kt1ymtQ%3D%3D, PID: 2563839
    • Erbel R, et al. Echocardiography in diagnosis of aortic dissection. Lancet. 1989;1(8636):457–61.
    • (1989) Lancet , vol.1 , Issue.8636 , pp. 457-461
    • Erbel, R.1
  • 81
    • 0027397484 scopus 로고
    • The diagnosis of thoracic aortic dissection by noninvasive imaging procedures
    • COI: 1:STN:280:DyaK3s%2Fps1Sjsg%3D%3D, PID: 8416265
    • Nienaber CA, et al. The diagnosis of thoracic aortic dissection by noninvasive imaging procedures. N Engl J Med. 1993;328(1):1–9.
    • (1993) N Engl J Med , vol.328 , Issue.1 , pp. 1-9
    • Nienaber, C.A.1
  • 82
    • 78049416788 scopus 로고    scopus 로고
    • Safety of transesophageal echocardiography
    • PID: 20864313, (quiz 1220-1)
    • Hilberath JN, et al. Safety of transesophageal echocardiography. J Am Soc Echocardiogr. 2010;23(11):1115–27 (quiz 1220-1).
    • (2010) J Am Soc Echocardiogr , vol.23 , Issue.11 , pp. 1115-1127
    • Hilberath, J.N.1
  • 83
    • 84855324739 scopus 로고    scopus 로고
    • Use of a miniaturized transesophageal echocardiographic probe in the intensive care unit for diagnosis and treatment of a hemodynamically unstable patient after aortic valve replacement
    • PID: 21441039
    • Wagner CE, et al. Use of a miniaturized transesophageal echocardiographic probe in the intensive care unit for diagnosis and treatment of a hemodynamically unstable patient after aortic valve replacement. J Cardiothorac Vasc Anesth. 2012;26(1):95–7.
    • (2012) J Cardiothorac Vasc Anesth , vol.26 , Issue.1 , pp. 95-97
    • Wagner, C.E.1
  • 84
    • 78650506026 scopus 로고    scopus 로고
    • First experience with microprobe transoesophageal echocardiography in non-sedated adults undergoing atrial fibrillation ablation: feasibility study and comparison with intracardiac echocardiography
    • PID: 20880953
    • Stec S, et al. First experience with microprobe transoesophageal echocardiography in non-sedated adults undergoing atrial fibrillation ablation: feasibility study and comparison with intracardiac echocardiography. Europace. 2011;13(1):51–6.
    • (2011) Europace , vol.13 , Issue.1 , pp. 51-56
    • Stec, S.1
  • 85
    • 84884211325 scopus 로고    scopus 로고
    • A pilot study on safety and clinical utility of a single-use 72-h indwelling transesophageal echocardiography probe
    • PID: 23287876
    • Vieillard-Baron A, et al. A pilot study on safety and clinical utility of a single-use 72-h indwelling transesophageal echocardiography probe. Intensive Care Med. 2013;39(4):629–35.
    • (2013) Intensive Care Med , vol.39 , Issue.4 , pp. 629-635
    • Vieillard-Baron, A.1
  • 86
    • 84884680208 scopus 로고    scopus 로고
    • Appropriate use and clinical impact of transthoracic echocardiography
    • PID: 23877630
    • Matulevicius SA, et al. Appropriate use and clinical impact of transthoracic echocardiography. JAMA Intern Med. 2013;173(17):1600–7.
    • (2013) JAMA Intern Med , vol.173 , Issue.17 , pp. 1600-1607
    • Matulevicius, S.A.1
  • 87
    • 84870556070 scopus 로고    scopus 로고
    • Applicability, limitations and downstream impact of echocardiography utilization based on the appropriateness use criteria for transthoracic and transesophageal echocardiography
    • PID: 22231468
    • Alqarqaz M, et al. Applicability, limitations and downstream impact of echocardiography utilization based on the appropriateness use criteria for transthoracic and transesophageal echocardiography. Int J Cardiovasc Imaging. 2012;28(8):1951–8.
    • (2012) Int J Cardiovasc Imaging , vol.28 , Issue.8 , pp. 1951-1958
    • Alqarqaz, M.1
  • 88
    • 34347392098 scopus 로고    scopus 로고
    • ACCF/ASE/ACEP/ASNC/SCAI/SCCT/SCMR 2007 appropriateness criteria for transthoracic and transesophageal echocardiography: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American Society of Echocardiography, American College of Emergency Physicians, American Society of Nuclear Cardiology, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, and the Society for Cardiovascular Magnetic Resonance. Endorsed by the American College of Chest Physicians and the Society of Critical Care Medicine
    • PID: 17617305
    • Douglas PS, et al. ACCF/ASE/ACEP/ASNC/SCAI/SCCT/SCMR 2007 appropriateness criteria for transthoracic and transesophageal echocardiography: a report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American Society of Echocardiography, American College of Emergency Physicians, American Society of Nuclear Cardiology, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, and the Society for Cardiovascular Magnetic Resonance. Endorsed by the American College of Chest Physicians and the Society of Critical Care Medicine. J Am Soc Echocardiogr. 2007;20(7):787–805.
    • (2007) J Am Soc Echocardiogr , vol.20 , Issue.7 , pp. 787-805
    • Douglas, P.S.1
  • 89
    • 79951982272 scopus 로고    scopus 로고
    • ACCF/ASE/AHA/ASNC/HFSA/HRS/SCAI/SCCM/SCCT/SCMR 2011 Appropriate Use Criteria for Echocardiography. A Report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, American Society of Echocardiography, American Heart Association, American Society of Nuclear Cardiology, Heart Failure Society of America, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Critical Care Medicine, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance American College of Chest Physicians
    • American College of Cardiology Foundation Appropriate Use Criteria Task Force et al. ACCF/ASE/AHA/ASNC/HFSA/HRS/SCAI/SCCM/SCCT/SCMR 2011 Appropriate Use Criteria for Echocardiography. A Report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, American Society of Echocardiography, American Heart Association, American Society of Nuclear Cardiology, Heart Failure Society of America, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Critical Care Medicine, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance American College of Chest Physicians. J Am Soc Echocardiogr. 2011;24(3):229–67.
    • (2011) J Am Soc Echocardiogr , vol.24 , Issue.3 , pp. 229-267
    • American College of Cardiology Foundation Appropriate Use Criteria Task Force et al1
  • 90
    • 84859733231 scopus 로고    scopus 로고
    • Ultrasound? Fetal monitoring? Spectrometer? There’s an app for that!: biomedical smart phone apps are taking healthcare by storm
    • PID: 22481741
    • Mertz L. Ultrasound? Fetal monitoring? Spectrometer? There’s an app for that!: biomedical smart phone apps are taking healthcare by storm. IEEE Pulse. 2012;3(2):16–21.
    • (2012) IEEE Pulse , vol.3 , Issue.2 , pp. 16-21
    • Mertz, L.1
  • 91
    • 84894335043 scopus 로고    scopus 로고
    • Toward image analysis and decision support for ultrasound technology
    • PID: 23920862
    • Crofts G, Padman R, Maharaja N. Toward image analysis and decision support for ultrasound technology. Stud Health Technol Inform. 2013;192:1088.
    • (2013) Stud Health Technol Inform , vol.192 , pp. 1088
    • Crofts, G.1    Padman, R.2    Maharaja, N.3
  • 92
    • 0026458193 scopus 로고
    • Role of echo/Doppler in the diagnosis of pulmonary embolism
    • COI: 1:STN:280:DC%2BD3cvjsFWrtQ%3D%3D, PID: 10969623
    • Torbicki A, Tramarin R, Morpurgo M. Role of echo/Doppler in the diagnosis of pulmonary embolism. Clin Cardiol. 1992;15(11):805–10.
    • (1992) Clin Cardiol , vol.15 , Issue.11 , pp. 805-810
    • Torbicki, A.1    Tramarin, R.2    Morpurgo, M.3
  • 93
    • 84876762701 scopus 로고    scopus 로고
    • Echo rounds: McConnell’s sign in acute pulmonary embolism
    • PID: 23492961
    • Lau G, Ther G, Swanevelder J. Echo rounds: McConnell’s sign in acute pulmonary embolism. Anesth Analg. 2013;116(5):982–5.
    • (2013) Anesth Analg , vol.116 , Issue.5 , pp. 982-985
    • Lau, G.1    Ther, G.2    Swanevelder, J.3
  • 94
    • 0030586835 scopus 로고    scopus 로고
    • Regional right ventricular dysfunction detected by echocardiography in acute pulmonary embolism
    • COI: 1:STN:280:DyaK28zlvFCisg%3D%3D, PID: 8752195
    • McConnell MV, et al. Regional right ventricular dysfunction detected by echocardiography in acute pulmonary embolism. Am J Cardiol. 1996;78(4):469–73.
    • (1996) Am J Cardiol , vol.78 , Issue.4 , pp. 469-473
    • McConnell, M.V.1
  • 95
    • 12344331253 scopus 로고    scopus 로고
    • Regional right ventricular dysfunction in acute pulmonary embolism and right ventricular infarction
    • PID: 15664548
    • Casazza F, et al. Regional right ventricular dysfunction in acute pulmonary embolism and right ventricular infarction. Eur J Echocardiogr. 2005;6(1):11–4.
    • (2005) Eur J Echocardiogr , vol.6 , Issue.1 , pp. 11-14
    • Casazza, F.1
  • 96
    • 84927664575 scopus 로고    scopus 로고
    • Echocardiographic findings in pulmonary embolism: an important guide for the management of the patient
    • Cohen R, et al. Echocardiographic findings in pulmonary embolism: an important guide for the management of the patient. World J Cardiovasc Dis. 2012;2:161–4.
    • (2012) World J Cardiovasc Dis , vol.2 , pp. 161-164
    • Cohen, R.1
  • 97
    • 0030861593 scopus 로고    scopus 로고
    • Noninvasive diagnosis of suspected severe pulmonary embolism: transesophageal echocardiography vs spiral CT
    • COI: 1:STN:280:DyaK2svlvFyntA%3D%3D, PID: 9315806
    • Pruszczyk P, et al. Noninvasive diagnosis of suspected severe pulmonary embolism: transesophageal echocardiography vs spiral CT. Chest. 1997;112(3):722–8.
    • (1997) Chest , vol.112 , Issue.3 , pp. 722-728
    • Pruszczyk, P.1
  • 98
    • 0030014825 scopus 로고    scopus 로고
    • Use of transthoracic Doppler echocardiography combined with clinical and electrocardiographic data to predict acute pulmonary embolism
    • COI: 1:STN:280:DyaK28zks1Oqsw%3D%3D, PID: 8737110
    • Nazeyrollas P, et al. Use of transthoracic Doppler echocardiography combined with clinical and electrocardiographic data to predict acute pulmonary embolism. Eur Heart J. 1996;17(5):779–86.
    • (1996) Eur Heart J , vol.17 , Issue.5 , pp. 779-786
    • Nazeyrollas, P.1
  • 99
    • 84891680749 scopus 로고    scopus 로고
    • Poor positive predictive value of McConnell’s sign on transthoracic echocardiography for the diagnosis of acute pulmonary embolism
    • Vaid U, et al. Poor positive predictive value of McConnell’s sign on transthoracic echocardiography for the diagnosis of acute pulmonary embolism. Hosp Pract (1995). 2013;41(3):23–7.
    • (2013) Hosp Pract (1995) , vol.41 , Issue.3 , pp. 23-27
    • Vaid, U.1
  • 101
    • 62049083892 scopus 로고    scopus 로고
    • Single center experience with application of the ALARA concept to serial imaging studies after blunt renal trauma in children—is ultrasound enough?
    • PID: 19233392, (discussion 1840)
    • Eeg KR, et al. Single center experience with application of the ALARA concept to serial imaging studies after blunt renal trauma in children—is ultrasound enough? J Urol. 2009;181(4):1834–40 (discussion 1840).
    • (2009) J Urol , vol.181 , Issue.4 , pp. 1834-1840
    • Eeg, K.R.1
  • 102
    • 33646071819 scopus 로고    scopus 로고
    • The mechanical index, ultrasound practices, and the ALARA principle
    • PID: 16567451, (author reply 561–2)
    • Toms DA. The mechanical index, ultrasound practices, and the ALARA principle. J Ultrasound Med. 2006;25(4):560–1 (author reply 561–2).
    • (2006) J Ultrasound Med , vol.25 , Issue.4 , pp. 560-561
    • Toms, D.A.1
  • 103
    • 84862799631 scopus 로고    scopus 로고
    • The impact of pre-operative focused transthoracic echocardiography in emergency non-cardiac surgery patients with known or risk of cardiac disease
    • COI: 1:STN:280:DC%2BC38vpvFKrug%3D%3D, PID: 22452367
    • Canty DJ, et al. The impact of pre-operative focused transthoracic echocardiography in emergency non-cardiac surgery patients with known or risk of cardiac disease. Anaesthesia. 2012;67(7):714–20.
    • (2012) Anaesthesia , vol.67 , Issue.7 , pp. 714-720
    • Canty, D.J.1
  • 104
    • 0041334164 scopus 로고    scopus 로고
    • The sonographer practitioner: one piece to the radiologist shortage puzzle
    • PID: 14510256
    • Lockhart ME, et al. The sonographer practitioner: one piece to the radiologist shortage puzzle. J Ultrasound Med. 2003;22(9):861–4.
    • (2003) J Ultrasound Med , vol.22 , Issue.9 , pp. 861-864
    • Lockhart, M.E.1
  • 105
    • 33646552032 scopus 로고    scopus 로고
    • Understanding sonographer burnout
    • Walvoord KH. Understanding sonographer burnout. J Diagn Med Sonogr. 2006;22:200–5.
    • (2006) J Diagn Med Sonogr , vol.22 , pp. 200-205
    • Walvoord, K.H.1
  • 106
    • 34548650249 scopus 로고    scopus 로고
    • Sonographic training program at a district hospital in a developing country: work in progress
    • PID: 17715076
    • Ferraioli G, Meloni MF. Sonographic training program at a district hospital in a developing country: work in progress. AJR Am J Roentgenol. 2007;189(3):W119–22.
    • (2007) AJR Am J Roentgenol , vol.189 , Issue.3 , pp. W119-W122
    • Ferraioli, G.1    Meloni, M.F.2
  • 107
    • 84943359006 scopus 로고    scopus 로고
    • the sonographer shortage: a misguided debate or the real deal?
    • Witt S. the sonographer shortage: a misguided debate or the real deal? J Am Soc Echocardiogr. 2005;18:A25–6.
    • (2005) J Am Soc Echocardiogr , vol.18 , pp. A25-A26
    • Witt, S.1
  • 108
    • 13444305239 scopus 로고    scopus 로고
    • Hand-held miniaturized cardiac ultrasound instruments for rapid and effective bedside diagnosis and patient screening
    • PID: 15660539
    • Scholten C, et al. Hand-held miniaturized cardiac ultrasound instruments for rapid and effective bedside diagnosis and patient screening. J Eval Clin Pract. 2005;11(1):67–72.
    • (2005) J Eval Clin Pract , vol.11 , Issue.1 , pp. 67-72
    • Scholten, C.1
  • 109
    • 84867845784 scopus 로고    scopus 로고
    • Teaching TEE for use in the operating room: where are things now…and where are we going?
    • PID: 22625218
    • Adams MS. Teaching TEE for use in the operating room: where are things now…and where are we going? J Am Soc Echocardiogr. 2012;25(6):17A–8A.
    • (2012) J Am Soc Echocardiogr , vol.25 , Issue.6 , pp. 17A-18A
    • Adams, M.S.1
  • 110
    • 84942242739 scopus 로고    scopus 로고
    • Diagnostic performance of emergency transthoracic focus cardiac ultrasound in suspected acute type A aortic dissection
    • PID: 24871637
    • Nazerian P, et al. Diagnostic performance of emergency transthoracic focus cardiac ultrasound in suspected acute type A aortic dissection. Intern Emerg Med. 2014;9:665–70.
    • (2014) Intern Emerg Med , vol.9 , pp. 665-670
    • Nazerian, P.1
  • 111
    • 78349265344 scopus 로고    scopus 로고
    • Bedside transthoracic sonography in suspected pulmonary embolism: a new tool for emergency physicians
    • PID: 20836767
    • Hoffmann B, Gullett JP. Bedside transthoracic sonography in suspected pulmonary embolism: a new tool for emergency physicians. Acad Emerg Med. 2010;17(9):e88–93.
    • (2010) Acad Emerg Med , vol.17 , Issue.9 , pp. e88-e93
    • Hoffmann, B.1    Gullett, J.P.2
  • 112
    • 84902252701 scopus 로고    scopus 로고
    • M., R. American College of, and U. Society of Radiologists in, AIUM practice guideline for the performance of peripheral arterial ultrasound examinations using color and spectral doppler imaging
    • American Institute of Ultrasound in. M., R. American College of, and U. Society of Radiologists in, AIUM practice guideline for the performance of peripheral arterial ultrasound examinations using color and spectral doppler imaging. J Ultrasound Med. 2014;33(6):1111–21.
    • (2014) J Ultrasound Med , vol.33 , Issue.6 , pp. 1111-1121
    • American Institute of Ultrasound in1
  • 113
    • 84887224808 scopus 로고    scopus 로고
    • Comparison between angiographic and arterial duplex ultrasound assessment of tibial arteries in patients with peripheral arterial disease: on behalf of the Joint Endovascular and Non-Invasive Assessment of LImb Perfusion (JENALI) Group
    • PID: 24184896
    • Mustapha JA, et al. Comparison between angiographic and arterial duplex ultrasound assessment of tibial arteries in patients with peripheral arterial disease: on behalf of the Joint Endovascular and Non-Invasive Assessment of LImb Perfusion (JENALI) Group. J Invasive Cardiol. 2013;25(11):606–11.
    • (2013) J Invasive Cardiol , vol.25 , Issue.11 , pp. 606-611
    • Mustapha, J.A.1
  • 114
    • 84891867280 scopus 로고    scopus 로고
    • Ultrasound-guided peripheral venous access: a systematic review of randomized-controlled trials
    • PID: 23880981
    • Liu YT, Alsaawi A, Bjornsson HM. Ultrasound-guided peripheral venous access: a systematic review of randomized-controlled trials. Eur J Emerg Med. 2014;21(1):18–23.
    • (2014) Eur J Emerg Med , vol.21 , Issue.1 , pp. 18-23
    • Liu, Y.T.1    Alsaawi, A.2    Bjornsson, H.M.3
  • 115
    • 33846957666 scopus 로고    scopus 로고
    • Lower extremity arterial thrombosis following sonographically guided thrombin injection of a femoral pseudoaneurysm
    • PID: 16960880
    • Stawicki SP, Hoey BA. Lower extremity arterial thrombosis following sonographically guided thrombin injection of a femoral pseudoaneurysm. J Clin Ultrasound. 2007;35(2):88–93.
    • (2007) J Clin Ultrasound , vol.35 , Issue.2 , pp. 88-93
    • Stawicki, S.P.1    Hoey, B.A.2
  • 116
    • 49649111926 scopus 로고    scopus 로고
    • Vena cava filters: a synopsis of complications and related topics
    • COI: 1:STN:280:DC%2BD1cvjs12rsg%3D%3D, PID: 18609524
    • Stawicki SP, et al. Vena cava filters: a synopsis of complications and related topics. J Vasc Access. 2008;9(2):102–10.
    • (2008) J Vasc Access , vol.9 , Issue.2 , pp. 102-110
    • Stawicki, S.P.1
  • 117
    • 80051508758 scopus 로고    scopus 로고
    • Accidental carotid artery cannulation detected by bedside ultrasound
    • PID: 21691480
    • Chiles K, Nagdev A. Accidental carotid artery cannulation detected by bedside ultrasound. West J Emerg Med. 2011;12(1):100–1.
    • (2011) West J Emerg Med , vol.12 , Issue.1 , pp. 100-101
    • Chiles, K.1    Nagdev, A.2
  • 118
    • 0015952472 scopus 로고
    • Doppler sonography: a bedside noninvasive method for assessment of carotid artery disease
    • COI: 1:STN:280:DyaE2c%2Fpt12gsg%3D%3D, PID: 4812092
    • Hyman BN. Doppler sonography: a bedside noninvasive method for assessment of carotid artery disease. Am J Ophthalmol. 1974;77(2):227–31.
    • (1974) Am J Ophthalmol , vol.77 , Issue.2 , pp. 227-231
    • Hyman, B.N.1
  • 119
    • 0034811214 scopus 로고    scopus 로고
    • Screening for acute DVT: optimal utilization of the vascular diagnostic laboratory
    • COI: 1:STN:280:DC%2BD3Mrhtlemtw%3D%3D, PID: 11561282
    • Zierler BK. Screening for acute DVT: optimal utilization of the vascular diagnostic laboratory. Semin Vasc Surg. 2001;14(3):206–14.
    • (2001) Semin Vasc Surg , vol.14 , Issue.3 , pp. 206-214
    • Zierler, B.K.1
  • 120
    • 33847188122 scopus 로고    scopus 로고
    • Duplex ultrasound in the emergency department for the diagnostic management of clinically suspected deep vein thrombosis
    • PID: 17264203
    • Magazzini S, et al. Duplex ultrasound in the emergency department for the diagnostic management of clinically suspected deep vein thrombosis. Acad Emerg Med. 2007;14(3):216–20.
    • (2007) Acad Emerg Med , vol.14 , Issue.3 , pp. 216-220
    • Magazzini, S.1
  • 121
    • 0025102102 scopus 로고
    • Noninvasive estimation of right atrial pressures from the inspiratory collapse of the inferior vena cava
    • COI: 1:STN:280:DyaK3czltVKksw%3D%3D, PID: 2386120
    • Kircher BJ, Himelman RB, Schiller NB. Noninvasive estimation of right atrial pressures from the inspiratory collapse of the inferior vena cava. Am J Cardiol. 1990;66:493–6.
    • (1990) Am J Cardiol , vol.66 , pp. 493-496
    • Kircher, B.J.1    Himelman, R.B.2    Schiller, N.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.