메뉴 건너뛰기




Volumn 96, Issue SUPPL.3, 2013, Pages 14-22

Inferior vena cava diameter and collapsibility index: A practical non-invasive evaluation of intravascular fluid volume in critically-III patients

Author keywords

Central venous pressure; Collapsibility index; Inferior vena cava diameter; Intravascular fluid volume; Ultrasonography

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; BLOOD PRESSURE MONITORING; CENTRAL VENOUS PRESSURE; COLLAPSIBILITY INDEX; CORRELATION ANALYSIS; CROSS-SECTIONAL STUDY; ECHOGRAPHY; FEMALE; HEMODYNAMICS; HUMAN; HYPERVOLEMIA; HYPOVOLEMIC SHOCK; INFERIOR CAVA VEIN; INTENSIVE CARE UNIT; MAJOR CLINICAL STUDY; MALE; MANOMETER; POSITIVE END EXPIRATORY PRESSURE; PROSPECTIVE STUDY; RATING SCALE; SEPSIS; VEIN DIAMETER;

EID: 84876902375     PISSN: 01252208     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (31)

References (28)
  • 1
    • 33847048638 scopus 로고    scopus 로고
    • Current practice of hemodynamic monitoring and vasopressor and inotropic therapy in post-operative cardiac surgery patients in Germany: Results from a postal survey
    • Kastrup M, Markewitz A, Spies C, Carl M, Erb J, Grosse J, et al. Current practice of hemodynamic monitoring and vasopressor and inotropic therapy in post-operative cardiac surgery patients in Germany: results from a postal survey. Acta Anaesthesiol Scand 2007; 51: 347-58.
    • (2007) Acta Anaesthesiol Scand , vol.51 , pp. 347-358
    • Kastrup, M.1    Markewitz, A.2    Spies, C.3    Carl, M.4    Erb, J.5    Grosse, J.6
  • 2
    • 34547901343 scopus 로고    scopus 로고
    • A survey of Canadian intensivists' resuscitation practices in early septic shock
    • McIntyre LA, Hebert PC, Fergusson D, Cook DJ, Aziz A. A survey of Canadian intensivists' resuscitation practices in early septic shock. Crit Care 2007; 11: R74.
    • (2007) Crit Care , vol.11
    • McIntyre, L.A.1    Hebert, P.C.2    Fergusson, D.3    Cook, D.J.4    Aziz, A.5
  • 3
    • 0036168422 scopus 로고    scopus 로고
    • Complications of central venous catheters: Internal jugular versus subclavian access-a systematic review
    • Ruesch S, Walder B, Tramer MR. Complications of central venous catheters: internal jugular versus subclavian access-a systematic review. Crit Care Med 2002; 30: 454-60.
    • (2002) Crit Care Med , vol.30 , pp. 454-460
    • Ruesch, S.1    Walder, B.2    Tramer, M.R.3
  • 4
    • 84876906180 scopus 로고    scopus 로고
    • Ultrasound guided volume assessment using inferior vena cava diameter
    • Lyon ML, Verma N. Ultrasound guided volume assessment using inferior vena cava diameter. Open Emerg Med J 2010; 3: 22-4.
    • (2010) Open Emerg Med J , vol.3 , pp. 22-24
    • Lyon, M.L.1    Verma, N.2
  • 5
    • 0018647564 scopus 로고
    • Ultrasonographic evaluation of ventilatory effect on inferior vena caval configuration
    • Natori H, Tamaki S, Kira S. Ultrasonographic evaluation of ventilatory effect on inferior vena caval configuration. Am Rev Respir Dis 1979; 120: 421-7.
    • (1979) Am Rev Respir Dis , vol.120 , pp. 421-427
    • Natori, H.1    Tamaki, S.2    Kira, S.3
  • 6
    • 38449087991 scopus 로고    scopus 로고
    • Intensivist bedside ultrasound (INBU) for volume assessment in the intensive care unit: A pilot study
    • Carr BG, Dean AJ, Everett WW, Ku BS, Mark DG, Okusanya O, et al. Intensivist bedside ultrasound (INBU) for volume assessment in the intensive care unit: a pilot study. J Trauma 2007; 63: 495-500.
    • (2007) J Trauma , vol.63 , pp. 495-500
    • Carr, B.G.1    Dean, A.J.2    Everett, W.W.3    Ku, B.S.4    Mark, D.G.5    Okusanya, O.6
  • 7
    • 20244370575 scopus 로고    scopus 로고
    • Feasibility and potential clinical utility of goal-directed transthoracic echocardiography performed by noncardiologist intensivists using a small handcarried device (SonoHeart) in critically ill patients
    • Manasia AR, Nagaraj HM, Kodali RB, Croft LB, Oropello JM, Kohli-Seth R, et al. Feasibility and potential clinical utility of goal-directed transthoracic echocardiography performed by noncardiologist intensivists using a small handcarried device (SonoHeart) in critically ill patients. J Cardiothorac Vasc Anesth 2005; 19: 155-9.
    • (2005) J Cardiothorac Vasc Anesth , vol.19 , pp. 155-159
    • Manasia, A.R.1    Nagaraj, H.M.2    Kodali, R.B.3    Croft, L.B.4    Oropello, J.M.5    Kohli-Seth, R.6
  • 8
    • 67349286164 scopus 로고    scopus 로고
    • Intensivist use of hand-carried ultrasonography to measure IVC collapsibility in estimating intravascular volume status: Correlations with CVP
    • Stawicki SP, Braslow BM, Panebianco NL, Kirkpatrick JN, Gracias VH, Hayden GE, et al. Intensivist use of hand-carried ultrasonography to measure IVC collapsibility in estimating intravascular volume status: correlations with CVP. J Am Coll Surg 2009; 209: 55-61.
    • (2009) J Am Coll Surg , vol.209 , pp. 55-61
    • Stawicki, S.P.1    Braslow, B.M.2    Panebianco, N.L.3    Kirkpatrick, J.N.4    Gracias, V.H.5    Hayden, G.E.6
  • 9
    • 12744265204 scopus 로고    scopus 로고
    • Sonographic measurement of the inferior vena cava as a marker of blood loss
    • Lyon M, Blaivas M, Brannam L. Sonographic measurement of the inferior vena cava as a marker of blood loss. Am J Emerg Med 2005; 23: 45-50.
    • (2005) Am J Emerg Med , vol.23 , pp. 45-50
    • Lyon, M.1    Blaivas, M.2    Brannam, L.3
  • 10
    • 0034965104 scopus 로고    scopus 로고
    • Inferior vena cava diameter: A useful method for estimation of fluid status in children on haemodialysis
    • Krause I, Birk E, Davidovits M, Cleper R, Blieden L, Pinhas L, et al. Inferior vena cava diameter: a useful method for estimation of fluid status in children on haemodialysis. Nephrol Dial Transplant 2001; 16: 1203-6.
    • (2001) Nephrol Dial Transplant , vol.16 , pp. 1203-1206
    • Krause, I.1    Birk, E.2    Davidovits, M.3    Cleper, R.4    Blieden, L.5    Pinhas, L.6
  • 11
    • 77952543391 scopus 로고    scopus 로고
    • Inferior vena cava diameter correlates with invasive hemodynamic measures in mechanically ventilated intensive care unit patients with sepsis
    • Schefold JC, Storm C, Bercker S, Pschowski R, Oppert M, Kruger A, et al. Inferior vena cava diameter correlates with invasive hemodynamic measures in mechanically ventilated intensive care unit patients with sepsis. J Emerg Med 2010; 38: 632-7.
    • (2010) J Emerg Med , vol.38 , pp. 632-637
    • Schefold, J.C.1    Storm, C.2    Bercker, S.3    Pschowski, R.4    Oppert, M.5    Kruger, A.6
  • 12
    • 0027352991 scopus 로고
    • Echocardiographic determination of valid zero reference levels in supine and lateral positions
    • Kee LL, Simonson JS, Stotts NA, Skov P, Schiller NB. Echocardiographic determination of valid zero reference levels in supine and lateral positions. Am J Crit Care 1993; 2: 72-80.
    • (1993) Am J Crit Care , vol.2 , pp. 72-80
    • Kee, L.L.1    Simonson, J.S.2    Stotts, N.A.3    Skov, P.4    Schiller, N.B.5
  • 13
    • 84876923431 scopus 로고    scopus 로고
    • What is the best way to fluid-resuscitate a patient with sepsis?
    • In: Deutschman CS, Neligan P, editors, Philadelphia: Saunders-Elsevier
    • Neligan PJ, Fanning N. What is the best way to fluid-resuscitate a patient with sepsis? In: Deutschman CS, Neligan P, editors. Evidencebased practice of critical care. Philadelphia: Saunders-Elsevier; 2010: 198-205.
    • (2010) Evidencebased Practice of Critical Care , pp. 198-205
    • Neligan, P.J.1    Fanning, N.2
  • 15
    • 33845360372 scopus 로고    scopus 로고
    • Central venous pressure monitoring
    • Dalrymple P. Central venous pressure monitoring. Anesth Intensive Care Med 2006; 7: 91-2.
    • (2006) Anesth Intensive Care Med , vol.7 , pp. 91-92
    • Dalrymple, P.1
  • 16
    • 12144287425 scopus 로고    scopus 로고
    • Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects
    • Kumar A, Anel R, Bunnell E, Habet K, Zanotti S, Marshall S, et al. Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med 2004; 32: 691-9.
    • (2004) Crit Care Med , vol.32 , pp. 691-699
    • Kumar, A.1    Anel, R.2    Bunnell, E.3    Habet, K.4    Zanotti, S.5    Marshall, S.6
  • 17
    • 47549096309 scopus 로고    scopus 로고
    • Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares
    • Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest 2008; 134: 172-8.
    • (2008) Chest , vol.134 , pp. 172-178
    • Marik, P.E.1    Baram, M.2    Vahid, B.3
  • 19
    • 18344363998 scopus 로고    scopus 로고
    • Let us use the pulmonary artery catheter correctly and only when we need it
    • Pinsky MR, Vincent JL. Let us use the pulmonary artery catheter correctly and only when we need it. Crit Care Med 2005; 33: 1119-22.
    • (2005) Crit Care Med , vol.33 , pp. 1119-1122
    • Pinsky, M.R.1    Vincent, J.L.2
  • 20
    • 33745081608 scopus 로고    scopus 로고
    • Comparison of two fluid-management strategies in acute lung injury. National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network
    • Wiedemann HP, Wheeler AP, Bernard GR, Thompson BT, Hayden D, deBoisblanc B, et al. Comparison of two fluid-management strategies in acute lung injury. National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network. N Engl J Med 2006; 354: 2564-75.
    • (2006) N Engl J Med , vol.354 , pp. 2564-2575
    • Wiedemann, H.P.1    Wheeler, A.P.2    Bernard, G.R.3    Thompson, B.T.4    Hayden, D.5    Deboisblanc, B.6
  • 21
    • 0035829842 scopus 로고    scopus 로고
    • Early goal-directed therapy in the treatment of severe sepsis and septic shock
    • Rivers E, Nguyen B, Havstad S, Ressler J, Muzzin A, Knoblich B, et al. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001; 345: 1368-77.
    • (2001) N Engl J Med , vol.345 , pp. 1368-1377
    • Rivers, E.1    Nguyen, B.2    Havstad, S.3    Ressler, J.4    Muzzin, A.5    Knoblich, B.6
  • 22
    • 33746713672 scopus 로고    scopus 로고
    • Management of severe sepsis and septic shock: Challenges and recommendations
    • ix
    • Gullo A, Bianco N, Berlot G. Management of severe sepsis and septic shock: challenges and recommendations. Crit Care Clin 2006; 22: 489-501, ix.
    • (2006) Crit Care Clin , vol.22 , pp. 489-501
    • Gullo, A.1    Bianco, N.2    Berlot, G.3
  • 23
    • 34247402616 scopus 로고    scopus 로고
    • Ultrasound imaging in vascular access
    • Maecken T, Grau T. Ultrasound imaging in vascular access. Crit Care Med 2007; 35 (5 Suppl): S178-85.
    • (2007) Crit Care Med , vol.35 , Issue.5 SUPPL. , pp. 178-185
    • Maecken, T.1    Grau, T.2
  • 24
    • 0025102102 scopus 로고
    • Noninvasive estimation of right atrial pressure from the inspiratory collapse of the inferior vena cava
    • Kircher BJ, Himelman RB, Schiller NB. Noninvasive estimation of right atrial pressure from the inspiratory collapse of the inferior vena cava. Am J Cardiol 1990; 66: 493-6.
    • (1990) Am J Cardiol , vol.66 , pp. 493-496
    • Kircher, B.J.1    Himelman, R.B.2    Schiller, N.B.3
  • 25
    • 76549132440 scopus 로고    scopus 로고
    • Emergency department bedside ultrasonographic measurement of the caval index for noninvasive determination of low central venous pressure
    • Nagdev AD, Merchant RC, Tirado-Gonzalez A, Sisson CA, Murphy MC. Emergency department bedside ultrasonographic measurement of the caval index for noninvasive determination of low central venous pressure. Ann Emerg Med 2010; 55: 290-5.
    • (2010) Ann Emerg Med , vol.55 , pp. 290-295
    • Nagdev, A.D.1    Merchant, R.C.2    Tirado-Gonzalez, A.3    Sisson, C.A.4    Murphy, M.C.5
  • 26
    • 77956574441 scopus 로고    scopus 로고
    • New echocardiographic parameters of fluid responsiveness in ventilated patients
    • Vieillard-Barlon A, Jardin F. New echocardiographic parameters of fluid responsiveness in ventilated patients. Intensive Care Emerg Med 2005; 12: 553-60.
    • (2005) Intensive Care Emerg Med , vol.12 , pp. 553-560
    • Vieillard-Barlon, A.1    Jardin, F.2
  • 27
    • 0024596160 scopus 로고
    • Two-dimensional echocardiographic evaluation of inferior vena cava, right ventricle, and left ventricle during positive-pressure ventilation with varying levels of positive endexpiratory pressure
    • Mitaka C, Nagura T, Sakanishi N, Tsunoda Y, Amaha K. Two-dimensional echocardiographic evaluation of inferior vena cava, right ventricle, and left ventricle during positive-pressure ventilation with varying levels of positive endexpiratory pressure. Crit Care Med 1989; 17: 205-210.
    • (1989) Crit Care Med , vol.17 , pp. 205-210
    • Mitaka, C.1    Nagura, T.2    Sakanishi, N.3    Tsunoda, Y.4    Amaha, K.5
  • 28
    • 0033958317 scopus 로고    scopus 로고
    • Variations in end-expiratory pressure during partial liquid ventilation: Impact on gas exchange, lung compliance, and end-expiratory lung volume
    • Manaligod JM, Bendel-Stenzel EM, Meyers PA, Bing DR, Connett JE, Mammel MC. Variations in end-expiratory pressure during partial liquid ventilation: impact on gas exchange, lung compliance, and end-expiratory lung volume. Chest 2000; 117: 184-90
    • (2000) Chest , vol.117 , pp. 184-190
    • Manaligod, J.M.1    Bendel-Stenzel, E.M.2    Meyers, P.A.3    Bing, D.R.4    Connett, J.E.5    Mammel, M.C.6