Volumn 41, Issue 3, 1999, Pages 269-276

Comparison of esophageal Doppler monitor generated minute distance and cardiac output in a porcine model of ventricular fibrillation

Author keywords

Aorta; Cardiac output; Cardiopulmonary resuscitation; Pulmonary artery catheter

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; AORTA FLOW; ARTICLE; BLOOD FLOW VELOCITY; BLOOD VESSEL DIAMETER; CORRELATION FUNCTION; DOPPLER ECHOGRAPHY; EQUIPMENT; FLUORESCENCE ANALYSIS; HEART ARREST; HEART OUTPUT; HEART VENTRICLE FIBRILLATION; NONHUMAN; PRIORITY JOURNAL; RESUSCITATION; SWINE; TISSUE PERFUSION; ULTRASOUND TRANSDUCER;

EID: 0032885401     PISSN: 03009572     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0300-9572(99)00053-2     Document Type: Article
Times cited : (7)

References (31)
  • 1
    • 0022545231 scopus 로고
    • Continuous non-invasive monitoring of cardiac output with the esophageal Doppler ultrasound during cardiac surgery
    • Mark N., Steinbrook R., Gugino L. et al. Continuous non-invasive monitoring of cardiac output with the esophageal Doppler ultrasound during cardiac surgery. Anesth. Analg. 65:1986;1013-1020.
    • (1986) Anesth. Analg. , vol.65 , pp. 1013-1020
    • Mark, N.1    Steinbrook, R.2    Gugino, L.3
  • 2
    • 0024394464 scopus 로고
    • Continuous hemodynamic monitoring by esophageal Doppler
    • Singer M., Clarke J., Bennett O. Continuous hemodynamic monitoring by esophageal Doppler. Crit. Care Med. 17:1989;447-452.
    • (1989) Crit. Care Med. , vol.17 , pp. 447-452
    • Singer, M.1    Clarke, J.2    Bennett, O.3
  • 3
    • 0342380739 scopus 로고
    • Cardiac output measurement by four methods in intensive care units: Interest of oesophageal Doppler device
    • Abst
    • Valtier B, Mottin D, Nolland B, Molis T, Payen D. Cardiac output measurement by four methods in intensive care units: interest of oesophageal Doppler device. Am Rev Resp Dis 1992;145:A781 (Abst).
    • (1992) Am Rev Resp Dis , vol.145
    • Valtier, B.1    Mottin, D.2    Nolland, B.3    Molis, T.4    Payen, D.5
  • 4
    • 0025947060 scopus 로고
    • Continuous hemodynamic monitoring by esophageal Doppler
    • Singer M., Clarke J., Bennett E.D. Continuous hemodynamic monitoring by esophageal Doppler. Crit. Care Med. 19:1991;1132-1137.
    • (1991) Crit. Care Med. , vol.19 , pp. 1132-1137
    • Singer, M.1    Clarke, J.2    Bennett, E.D.3
  • 5
    • 0024419202 scopus 로고
    • Non-invasive measurements of cardiac output during surgery using a new continuous - Wave Doppler esophageal probe
    • Kumar A., Minagoe S., Thangathurai D. et al. Non-invasive measurements of cardiac output during surgery using a new continuous - wave Doppler esophageal probe. Am. J. Cardiol. 64:1989;793-798.
    • (1989) Am. J. Cardiol. , vol.64 , pp. 793-798
    • Kumar, A.1    Minagoe, S.2    Thangathurai, D.3
  • 6
    • 0024477816 scopus 로고
    • Optimization of positive end-expiratory pressure for maximal delivery of oxygen to tissues by using oesophageal Doppler ultrasonography
    • Singer M., Bennett D. Optimization of positive end-expiratory pressure for maximal delivery of oxygen to tissues by using oesophageal Doppler ultrasonography. Br. Med. J. 298:1989;1350-1353.
    • (1989) Br. Med. J. , vol.298 , pp. 1350-1353
    • Singer, M.1    Bennett, D.2
  • 7
    • 0013614946 scopus 로고
    • Comparison of simultaneous intraoperative measurements of cardiac output by thermodilution, esophageal Doppler and electrical impedance in anesthetized patients
    • 1
    • Siegel LC, Shafer SL, Martinez GM et al. Comparison of simultaneous intraoperative measurements of cardiac output by thermodilution, esophageal Doppler and electrical impedance in anesthetized patients. Anesthesiology 1987;V67:A18[1].
    • (1987) Anesthesiology , vol.V67
    • Siegel, L.C.1    Shafer, S.L.2    Martinez, G.M.3
  • 8
    • 0025947060 scopus 로고
    • Non-invasive optimization of left ventricular filling by esophageal Doppler
    • Singer M., Bennett D. Non-invasive optimization of left ventricular filling by esophageal Doppler. Crit. Care Med. 19:1991;1132-1137.
    • (1991) Crit. Care Med. , vol.19 , pp. 1132-1137
    • Singer, M.1    Bennett, D.2
  • 9
    • 0345335948 scopus 로고
    • The role of the oesophageal Doppler in prevention of postoperative complications
    • Webb A.R. The role of the oesophageal Doppler in prevention of postoperative complications. Int. Proc. J. 1(1):1994;10-21.
    • (1994) Int. Proc. J. , vol.1 , Issue.1 , pp. 10-21
    • Webb, A.R.1
  • 10
    • 0026681877 scopus 로고
    • Non-invasive cardiac output measurement: Troubled technologies and troubled studies
    • Siegel L.C., Pearl R.G. Non-invasive cardiac output measurement: troubled technologies and troubled studies. Anesth. Analg. 74:1992;790-792.
    • (1992) Anesth. Analg. , vol.74 , pp. 790-792
    • Siegel, L.C.1    Pearl, R.G.2
  • 11
    • 0025898747 scopus 로고    scopus 로고
    • Comparison of changes in transit time ultrasound, esophageal Doppler, and thermodilution cardiac output after changes in preload, afterload and contractility in pigs
    • Wong DH, Watson T, Gorden I et al. Comparison of changes in transit time ultrasound, esophageal Doppler, and thermodilution cardiac output after changes in preload, afterload and contractility in pigs. Anesth Analg 72(5):584-588.
    • Anesth Analg , vol.72 , Issue.5 , pp. 584-588
    • Wong, D.H.1    Watson, T.2    Gorden, I.3
  • 12
    • 0031871297 scopus 로고    scopus 로고
    • Non-invasive monitoring of cardiac output in critically ill patients using transesophageal Doppler
    • Valiter B., Cholley B.P., Belot J.P. et al. Non-invasive monitoring of cardiac output in critically ill patients using transesophageal Doppler. Am. J. Resp. Crit. Care Med. 158(1):1998;77-83.
    • (1998) Am. J. Resp. Crit. Care Med. , vol.158 , Issue.1 , pp. 77-83
    • Valiter, B.1    Cholley, B.P.2    Belot, J.P.3
  • 13
    • 0030879480 scopus 로고    scopus 로고
    • The perioperative use of the esophageal Doppler monitor in patients undergoing coronary artery vascularization. A comparison with the continuous cardiac output monitor
    • Krishnamurthy B., McMarray T.J., McClean E. The perioperative use of the esophageal Doppler monitor in patients undergoing coronary artery vascularization. A comparison with the continuous cardiac output monitor. Anesthesia. 52(7):1997;624-629.
    • (1997) Anesthesia , vol.52 , Issue.7 , pp. 624-629
    • Krishnamurthy, B.1    McMarray, T.J.2    McClean, E.3
  • 14
    • 0029928910 scopus 로고    scopus 로고
    • A comparison of the use of transesophageal Doppler and thermodilution techniques for cardiac output determination
    • Keyl C., Rodig G., Lemberger P. et al. A comparison of the use of transesophageal Doppler and thermodilution techniques for cardiac output determination. Eur. J. Anesthesiol. 13(2):1996;136-142.
    • (1996) Eur. J. Anesthesiol. , vol.13 , Issue.2 , pp. 136-142
    • Keyl, C.1    Rodig, G.2    Lemberger, P.3
  • 15
    • 0027377406 scopus 로고
    • Reliability of a new generation transesophageal Doppler device for cardiac output monitoring
    • Schmid E.R., Spahn D.R., Tornic M. Reliability of a new generation transesophageal Doppler device for cardiac output monitoring. Anesth. Analg. 77(5):1993;971-979.
    • (1993) Anesth. Analg. , vol.77 , Issue.5 , pp. 971-979
    • Schmid, E.R.1    Spahn, D.R.2    Tornic, M.3
  • 16
    • 0031946626 scopus 로고    scopus 로고
    • Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients
    • LeFrant J.Y., Brucile P., Aya A.G. et al. Training is required to improve the reliability of esophageal Doppler to measure cardiac output in critically ill patients. Intensive Care Med. 24(4):1998;347-352.
    • (1998) Intensive Care Med. , vol.24 , Issue.4 , pp. 347-352
    • Lefrant, J.Y.1    Brucile, P.2    Aya, A.G.3
  • 17
    • 0022476656 scopus 로고
    • Impaired left ventricular function in acute myocardial infarction assessed by doppler measurement of ascending aortic blood velocity and maximum acceleration
    • Mehta N., Bennett D. Impaired left ventricular function in acute myocardial infarction assessed by doppler measurement of ascending aortic blood velocity and maximum acceleration. Am. J. Cardiol. 57:1986;1052-1058.
    • (1986) Am. J. Cardiol. , vol.57 , pp. 1052-1058
    • Mehta, N.1    Bennett, D.2
  • 18
    • 0025166460 scopus 로고
    • Non-invasive versus invasive assessment of cardiac output after cardiac surgery: Clinical validation
    • Spahn D.R., Schmid E.R., Tornic M. et al. Non-invasive versus invasive assessment of cardiac output after cardiac surgery: clinical validation. J. Cardiothorac. Anesth. 4(1):1990;46-59.
    • (1990) J. Cardiothorac. Anesth. , vol.4 , Issue.1 , pp. 46-59
    • Spahn, D.R.1    Schmid, E.R.2    Tornic, M.3
  • 19
    • 0026771006 scopus 로고
    • Clinical evaluation of transtracheal Doppler for continuous cardiac output estimation
    • Hausen B., Schafers H.J., Rohde R. et al. Clinical evaluation of transtracheal Doppler for continuous cardiac output estimation. Anesth. Analg. 74:1992;800-804.
    • (1992) Anesth. Analg. , vol.74 , pp. 800-804
    • Hausen, B.1    Schafers, H.J.2    Rohde, R.3
  • 20
    • 33748490825 scopus 로고
    • Ascending aortic blood flow velocity and acceleration using Doppler ultrasound in the assessment of left ventricular function
    • Bennett E.D., Barclay S.A., Davis A.L., Manering D., Mehta N. Ascending aortic blood flow velocity and acceleration using Doppler ultrasound in the assessment of left ventricular function. Cardiovasc. Res. 18:1984;632-638.
    • (1984) Cardiovasc. Res. , vol.18 , pp. 632-638
    • Bennett, E.D.1    Barclay, S.A.2    Davis, A.L.3    Manering, D.4    Mehta, N.5
  • 21
    • 0026768057 scopus 로고
    • Doppler cardiac output and left ventricular performance after cardiac surgery
    • Fratacci M., Payen D., Beloucif S., Laborde F. Doppler cardiac output and left ventricular performance after cardiac surgery. Chest. 102:1992;380-386.
    • (1992) Chest , vol.102 , pp. 380-386
    • Fratacci, M.1    Payen, D.2    Beloucif, S.3    Laborde, F.4
  • 22
    • 0023444282 scopus 로고
    • Pulsed Doppler ascending aortic, carotid, brachial, and femoral artery blood flows during caudal anesthesia in infants
    • Payen D., Ecoffey C., Carli P., Dubousset A. Pulsed Doppler ascending aortic, carotid, brachial, and femoral artery blood flows during caudal anesthesia in infants. Anesthesiology. 67:1987;681-687.
    • (1987) Anesthesiology , vol.67 , pp. 681-687
    • Payen, D.1    Ecoffey, C.2    Carli, P.3    Dubousset, A.4
  • 23
    • 0020655476 scopus 로고
    • The use of Doppler flow velocity measurement to assess the hemodynamic response to vasodilators in patients with heart failure
    • Elkayam U., Gardin J.M., Berkley R., Hughes W. The use of Doppler flow velocity measurement to assess the hemodynamic response to vasodilators in patients with heart failure. Circulation. 67:1983;377-383.
    • (1983) Circulation , vol.67 , pp. 377-383
    • Elkayam, U.1    Gardin, J.M.2    Berkley, R.3    Hughes, W.4
  • 24
    • 0021261809 scopus 로고
    • Non-invasive measurement of cardiac output by continuous-wave Doppler echocardiography: Initial experience and review of literature
    • Nishimura R., Callahan M., Schaff H., Tajik J., Miller F. Non-invasive measurement of cardiac output by continuous-wave Doppler echocardiography: initial experience and review of literature. Mayo Clin. Proc. 59:1984;484-489.
    • (1984) Mayo Clin. Proc. , vol.59 , pp. 484-489
    • Nishimura, R.1    Callahan, M.2    Schaff, H.3    Tajik, J.4    Miller, F.5
  • 25
    • 0023215903 scopus 로고
    • Transesophageal Doppler scanning versus thermodilution during general anesthesia. An initial comparison of cardiac output techniques
    • Freund P.R. Transesophageal Doppler scanning versus thermodilution during general anesthesia. An initial comparison of cardiac output techniques. Am. J. Surg. 153(5):1987;490-494.
    • (1987) Am. J. Surg. , vol.153 , Issue.5 , pp. 490-494
    • Freund, P.R.1
  • 26
    • 0025833943 scopus 로고
    • Transesophageal Doppler cardiac output monitoring; Performance during aortic reconstructive surgery
    • Perrino A.C. Jr., Fleming J., LaMantia K.R. Transesophageal Doppler cardiac output monitoring; performance during aortic reconstructive surgery. Anesth. Analg. 73(6):1991;705-710.
    • (1991) Anesth. Analg. , vol.73 , Issue.6 , pp. 705-710
    • Perrino A.C., Jr.1    Fleming, J.2    Lamantia, K.R.3
  • 27
    • 0025697265 scopus 로고
    • Transesophageal Doppler ultrasonography; Evidence for improved cardiac output monitoring
    • Perrino A.C. Jr., Fleming J., LaMantia K.R. Transesophageal Doppler ultrasonography; evidence for improved cardiac output monitoring. Anesth. Analg. 71(6):1990;651-657.
    • (1990) Anesth. Analg. , vol.71 , Issue.6 , pp. 651-657
    • Perrino A.C., Jr.1    Fleming, J.2    Lamantia, K.R.3
  • 28
    • 0020539186 scopus 로고
    • Aortic blood velocity measurement in healthy adults using a simple ultrasound technique
    • Mowat D.H.R., Haites N., Rawles J.M. Aortic blood velocity measurement in healthy adults using a simple ultrasound technique. Cardiovasc. Res. 17:1983;75-80.
    • (1983) Cardiovasc. Res. , vol.17 , pp. 75-80
    • Mowat, D.H.R.1    Haites, N.2    Rawles, J.M.3
  • 29
    • 0028968403 scopus 로고
    • Multiplane transesophageal echocardiographic Doppler imaging accurately determines cardiac output measurements in critically ill patients
    • Feinberg M.S., Hoplins W.E., Davila-Roman V.G. et al. Multiplane transesophageal echocardiographic Doppler imaging accurately determines cardiac output measurements in critically ill patients. Chest. 107(3):1995;769-773.
    • (1995) Chest , vol.107 , Issue.3 , pp. 769-773
    • Feinberg, M.S.1    Hoplins, W.E.2    Davila-Roman, V.G.3
  • 30
    • 0031135851 scopus 로고    scopus 로고
    • New semiautomated Doppler method for quantification of volumetric flow: Intraoperative validation with multiplane transesophageal Doppler imaging
    • Kim W.Y., Poulsen J.K., Terp K. et al. New semiautomated Doppler method for quantification of volumetric flow: intraoperative validation with multiplane transesophageal Doppler imaging. J. Am. Soc. Echocardiogr. 10(4):1997;330-336.
    • (1997) J. Am. Soc. Echocardiogr. , vol.10 , Issue.4 , pp. 330-336
    • Kim, W.Y.1    Poulsen, J.K.2    Terp, K.3
  • 31
    • 24444469710 scopus 로고    scopus 로고
    • Use of transoesophageal Doppler (TOD) to derive cardiac output measurements in ventilated children
    • no. 82
    • Tibby SM, Hatherill M et al. Use of transoesophageal Doppler (TOD) to derive cardiac output measurements in ventilated children. Crit Care Med 1998; 26, no.1 (suppl): A62, no. 82.
    • (1998) Crit Care Med , vol.26 , Issue.1 SUPPL.
    • Tibby, S.M.1    Hatherill, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.