메뉴 건너뛰기




Volumn 29, Issue 10, 2015, Pages e408-e413

Dorsal screw penetration with the use of volar plating of distal radius fractures: How can you best detect?

Author keywords

Cadaver study; Complication; Distal radius fracture; Extensor tendon rupture; Radiographic evaluation

Indexed keywords

ADULT; AGED; ARTICLE; BODY POSITION; BODY POSTURE; BONE DENSITY; BONE PLATE; CADAVER; CONTROLLED STUDY; DORSAL CORTEX SCREW PENETRATION; DORSAL TANGENTIAL VIEW; FLUOROSCOPY; FOREARM; HUMAN; HUMAN TISSUE; LOCKING SCREW; ORTHOPEDIC SURGEON; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; RADIUS FRACTURE; VERY ELDERLY; VOLAR PLATE FIXATION; BONE SCREW; COMPUTER ASSISTED SURGERY; DEVICES; FEMALE; IMAGE ENHANCEMENT; MALE; MIDDLE AGED; OSTEOSYNTHESIS; PATIENT POSITIONING; PROCEDURES; RADIOGRAPHY; RADIUS FRACTURES; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; WRIST INJURIES;

EID: 84942125089     PISSN: 08905339     EISSN: 15312291     Source Type: Journal    
DOI: 10.1097/BOT.0000000000000361     Document Type: Article
Times cited : (22)

References (27)
  • 1
    • 0034097721 scopus 로고    scopus 로고
    • Fractures of the distal radius treated by internal fixation and early function. A prospective study of 73 consecutive patients
    • Jakob M, Rikli DA, Regazzoni P. Fractures of the distal radius treated by internal fixation and early function. A prospective study of 73 consecutive patients. J Bone Joint Surg Br. 2000;82:340-344.
    • (2000) J Bone Joint Surg Br. , vol.82 , pp. 340-344
    • Jakob, M.1    Rikli, D.A.2    Regazzoni, P.3
  • 2
    • 0034536828 scopus 로고    scopus 로고
    • Open reduction and internal fixation of intra articular and unstable fractures of the distal radius using the AO distal radius plate
    • Campbell DA. Open reduction and internal fixation of intra articular and unstable fractures of the distal radius using the AO distal radius plate. J Hand Surg Br. 2000;25:528-534.
    • (2000) J Hand Surg Br. , vol.25 , pp. 528-534
    • Campbell, D.A.1
  • 3
    • 0038722227 scopus 로고    scopus 로고
    • Dorsal plating for displaced intraarticular fractures of the distal radius
    • Herron M, Faraj A, Craigen MA. Dorsal plating for displaced intraarticular fractures of the distal radius. Injury. 2003;34:497-502.
    • (2003) Injury , vol.34 , pp. 497-502
    • Herron, M.1    Faraj, A.2    Craigen, M.A.3
  • 4
    • 84903876790 scopus 로고    scopus 로고
    • Extensor pollicis longus tendon ruptures after the use of volar locking plates for distal radius fractures
    • Zenke Y, Sakai A, Oshige T, et al. Extensor pollicis longus tendon ruptures after the use of volar locking plates for distal radius fractures. Hand Surg. 2013;18:169-173.
    • (2013) Hand Surg. , vol.18 , pp. 169-173
    • Zenke, Y.1    Sakai, A.2    Oshige, T.3
  • 5
    • 79952393753 scopus 로고    scopus 로고
    • Minimising the risk of extensor pollicis longus rupture following volar plate fixation of distal radius fractures: A cadaveric study
    • Perry DC, Machin DM, Casaletto JA, et al. Minimising the risk of extensor pollicis longus rupture following volar plate fixation of distal radius fractures: a cadaveric study. Ann R Coll Surg Engl. 2011; 93:57-60.
    • (2011) Ann R Coll Surg Engl. , vol.93 , pp. 57-60
    • Perry, D.C.1    MacHin, D.M.2    Casaletto, J.A.3
  • 6
    • 0027216787 scopus 로고
    • Extensor pollicis longus rupture at the tip of a prominent fixation screw: Report of three cases
    • Failla JM, Koniuch MP, Moed BR. Extensor pollicis longus rupture at the tip of a prominent fixation screw: report of three cases. J Hand Surg Am. 1993;18:648-651.
    • (1993) J Hand Surg Am. , vol.18 , pp. 648-651
    • Failla, J.M.1    Koniuch, M.P.2    Moed, B.R.3
  • 7
    • 33749446244 scopus 로고    scopus 로고
    • Two potential causes of EPL rupture after distal radius volar plate fixation
    • Benson EC, DeCarvalho A, Mikola EA, et al. Two potential causes of EPL rupture after distal radius volar plate fixation. Clin Orthop Relat Res. 2006;451:218-222.
    • (2006) Clin Orthop Relat Res. , vol.451 , pp. 218-222
    • Benson, E.C.1    DeCarvalho, A.2    Mikola, E.A.3
  • 8
    • 0036130725 scopus 로고    scopus 로고
    • Volar fixation for dorsally displaced fractures of the distal radius: A preliminary report
    • Orbay JL, Fernandez DL. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am. 2002;27:205-215.
    • (2002) J Hand Surg Am. , vol.27 , pp. 205-215
    • Orbay, J.L.1    Fernandez, D.L.2
  • 9
    • 33644649770 scopus 로고    scopus 로고
    • Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius
    • Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am. 2006;31:359-365.
    • (2006) J Hand Surg Am. , vol.31 , pp. 359-365
    • Rozental, T.D.1    Blazar, P.E.2
  • 10
    • 11144271510 scopus 로고    scopus 로고
    • Sonography of a rupture of the tendon of the extensor pollicis longus muscle: Initial clinical experience and correlation with findings at cadaveric dissection
    • De Maeseneer M, Marcelis S, Osteaux M, et al. Sonography of a rupture of the tendon of the extensor pollicis longus muscle: initial clinical experience and correlation with findings at cadaveric dissection. AJR Am J Roentgenol. 2005;184:175-179.
    • (2005) AJR Am J Roentgenol. , vol.184 , pp. 175-179
    • De Maeseneer, M.1    Marcelis, S.2    Osteaux, M.3
  • 11
    • 0032460038 scopus 로고    scopus 로고
    • Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: A brief report
    • Kambouroglou GK, Axelrod TS. Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: a brief report. J Hand Surg Am. 1998;23:737-741.
    • (1998) J Hand Surg Am. , vol.23 , pp. 737-741
    • Kambouroglou, G.K.1    Axelrod, T.S.2
  • 12
    • 0030928604 scopus 로고    scopus 로고
    • Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures
    • Ring D, Jupiter JB, Brennwald J, et al. Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg Am. 1997;22:777-784.
    • (1997) J Hand Surg Am. , vol.22 , pp. 777-784
    • Ring, D.1    Jupiter, J.B.2    Brennwald, J.3
  • 13
    • 0034302091 scopus 로고    scopus 로고
    • Extensor tendon rupture secondary to the AO/ASIF titanium distal radius plate without associated plate failure: A case report
    • Lowry KJ, Gainor BJ, Hoskins JS. Extensor tendon rupture secondary to the AO/ASIF titanium distal radius plate without associated plate failure: a case report. Am J Orthop (Belle Mead NJ). 2000;29: 789-791.
    • (2000) Am J Orthop (Belle Mead NJ) , vol.29 , pp. 789-791
    • Lowry, K.J.1    Gainor, B.J.2    Hoskins, J.S.3
  • 14
    • 33845734224 scopus 로고    scopus 로고
    • Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures
    • Al-Rashid M, Theivendran K, Craigen MA. Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures. J Bone Joint Surg Br. 2006;88: 1610-1612.
    • (2006) J Bone Joint Surg Br. , vol.88 , pp. 1610-1612
    • Al-Rashid, M.1    Theivendran, K.2    Craigen, M.A.3
  • 15
    • 34248229716 scopus 로고    scopus 로고
    • Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate
    • Arora R, Lutz M, Hennerbichler A, et al. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma. 2007;21:316-322.
    • (2007) J Orthop Trauma , vol.21 , pp. 316-322
    • Arora, R.1    Lutz, M.2    Hennerbichler, A.3
  • 16
    • 7444263390 scopus 로고    scopus 로고
    • The 45 degrees pronated oblique view for volar fixed-angle plating of distal radius fractures
    • Smith DW, Henry MH. The 45 degrees pronated oblique view for volar fixed-angle plating of distal radius fractures. J Hand Surg Am. 2004;29: 703-706.
    • (2004) J Hand Surg Am. , vol.29 , pp. 703-706
    • Smith, D.W.1    Henry, M.H.2
  • 17
    • 58749103204 scopus 로고    scopus 로고
    • Use of fluoroscopy in determining screw overshoot in the dorsal distal radius: A cadaveric study
    • Thomas AD, Greenberg JA. Use of fluoroscopy in determining screw overshoot in the dorsal distal radius: a cadaveric study. J Hand Surg Am. 2009;34:258-261.
    • (2009) J Hand Surg Am. , vol.34 , pp. 258-261
    • Thomas, A.D.1    Greenberg, J.A.2
  • 18
    • 80053562284 scopus 로고    scopus 로고
    • The dorsal horizon view: Detecting screw protrusion at the distal radius
    • Joseph SJ, Harvey JN. The dorsal horizon view: detecting screw protrusion at the distal radius. J Hand Surg Am. 2011;36: 1691-1693.
    • (2011) J Hand Surg Am. , vol.36 , pp. 1691-1693
    • Joseph, S.J.1    Harvey, J.N.2
  • 19
    • 84860315693 scopus 로고    scopus 로고
    • Comparison of 4 fluoroscopic views for dorsal cortex screw penetration after volar plating of the distal radius
    • Ozer K, Wolf JM, Watkins B, et al. Comparison of 4 fluoroscopic views for dorsal cortex screw penetration after volar plating of the distal radius. J Hand Surg Am. 2012;37:963-967.
    • (2012) J Hand Surg Am. , vol.37 , pp. 963-967
    • Ozer, K.1    Wolf, J.M.2    Watkins, B.3
  • 20
    • 34547581677 scopus 로고    scopus 로고
    • Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: A cadaveric study
    • Maschke SD, Evans PJ, Schub D, et al. Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study. Hand (N Y). 2007;2:144-150.
    • (2007) Hand (N Y) , vol.2 , pp. 144-150
    • Maschke, S.D.1    Evans, P.J.2    Schub, D.3
  • 21
    • 84865744612 scopus 로고    scopus 로고
    • Volar plating for distal radius fractures-do not trust the image intensifier when judging distal subchondral screw length
    • Park DH, Goldie BS. Volar plating for distal radius fractures-do not trust the image intensifier when judging distal subchondral screw length. Tech Hand Up Extrem Surg. 2012;16:169-172.
    • (2012) Tech Hand Up Extrem Surg. , vol.16 , pp. 169-172
    • Park, D.H.1    Goldie, B.S.2
  • 22
    • 70449853877 scopus 로고    scopus 로고
    • Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis
    • Pichler W, Windisch G, Schaffler G, et al. Computer tomography aided 3D analysis of the distal dorsal radius surface and the effects on volar plate osteosynthesis. J Hand Surg Eur Vol. 2009;34:598-602.
    • (2009) J Hand Surg Eur Vol. , vol.34 , pp. 598-602
    • Pichler, W.1    Windisch, G.2    Schaffler, G.3
  • 23
    • 79955874759 scopus 로고    scopus 로고
    • Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating
    • Ozer K, Toker S. Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating. Hand (N Y). 2011;6:190-193.
    • (2011) Hand (N Y) , vol.6 , pp. 190-193
    • Ozer, K.1    Toker, S.2
  • 24
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159-174.
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 25
    • 22544478434 scopus 로고    scopus 로고
    • Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates
    • Musgrave DS, Idler RS. Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates. J Hand Surg Am. 2005;30:743-749.
    • (2005) J Hand Surg Am. , vol.30 , pp. 743-749
    • Musgrave, D.S.1    Idler, R.S.2
  • 26
    • 84857794955 scopus 로고    scopus 로고
    • The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates
    • Wall LB, Brodt MD, Silva MJ, et al. The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates. J Hand Surg Am. 2012;37:446-453.
    • (2012) J Hand Surg Am. , vol.37 , pp. 446-453
    • Wall, L.B.1    Brodt, M.D.2    Silva, M.J.3
  • 27
    • 84859260600 scopus 로고    scopus 로고
    • A biomechanical comparison of volar locked plating of intra-articular distal radius fractures: Use of 4 versus 7 screws for distal fixation
    • Moss DP, Means KR Jr, Parks BG, et al. A biomechanical comparison of volar locked plating of intra-articular distal radius fractures: use of 4 versus 7 screws for distal fixation. J Hand Surg Am. 2011;36:1907-1911.
    • (2011) J Hand Surg Am. , vol.36 , pp. 1907-1911
    • Moss, D.P.1    Means, K.R.2    Parks, B.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.