메뉴 건너뛰기




Volumn 93, Issue 1, 2011, Pages 57-60

Minimising the risk of extensor pollicis longus Rupture following volar plate fixation of distal radius fractures: A cadaveric study

Author keywords

Complications; Distal radius fracture; Flexor pollicis longus (FPL); Tendon; Volar plate

Indexed keywords

ARTICLE; BONE SCREW; CADAVER; HUMAN; KIRSCHNER WIRE; METHODOLOGY; OSTEOSYNTHESIS; RADIUS FRACTURE; RISK FACTOR; RUPTURE; TENDON INJURY; VOLAR PLATE;

EID: 79952393753     PISSN: 00358843     EISSN: None     Source Type: Journal    
DOI: 10.1308/003588411X12851639107151     Document Type: Article
Times cited : (16)

References (16)
  • 1
    • 0030928604 scopus 로고    scopus 로고
    • Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures
    • DOI 10.1016/S0363-5023(97)80069-X
    • Ring D, Jupiter JB, Brennwald J, Büchler U, Hastings H. Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg 1997;22:777-84. (Pubitemid 27431185)
    • (1997) Journal of Hand Surgery , vol.22 , Issue.5 , pp. 777-784
    • Ring, D.1    Jupiter, J.B.2    Brennwald, J.3    Buchler, U.4
  • 2
    • 0025364276 scopus 로고
    • Open reduction and internal fixation of comminuted, intraarticular fractures of the distal radius
    • Axelrod TS, McMurtry RY. Open reduction and internal fixation of comminuted, intraarticular fractures of the distal radius. J Hand Surg 1990;15:1-11. (Pubitemid 20093908)
    • (1990) Journal of Hand Surgery , vol.15 , Issue.1 , pp. 1-11
    • Axelrod, T.S.1    McMurtry, R.Y.2
  • 3
    • 0141889322 scopus 로고    scopus 로고
    • Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius
    • Rozental TD, Beredjiklian PK, Bozentka DJ. Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius. J Bone Joint Surg Am 2003;85:1956-60. (Pubitemid 37259732)
    • (2003) Journal of Bone and Joint Surgery - Series A , vol.85 , Issue.10 , pp. 1956-1960
    • Rozental, T.D.1    Beredjiklian, P.K.2    Bozentka, D.J.3
  • 4
    • 0034097721 scopus 로고    scopus 로고
    • Fractures of the distal radius treated by internal fixation and early function
    • Jakob M, Rikli DA, Regazzoni P. Fractures of the distal radius treated by internal fixation and early function. A prospective study of 73 consecutive patients. J Bone Joint Surg Br 2000;82:340-4. (Pubitemid 30248912)
    • (2000) Journal of Bone and Joint Surgery - Series B , vol.82 , Issue.3 , pp. 340-344
    • Jakob, M.1    Rikli, D.A.2    Regazzoni, P.3
  • 5
    • 34249708441 scopus 로고    scopus 로고
    • Locking Plate Technology and Its Applications in Upper Extremity Fracture Care
    • DOI 10.1016/j.hcl.2007.02.004, PII S0749071207000145, Forearm Injuries
    • Larson AN, Rizzo M. Locking plate technology and its applications in upper extremity fracture care. Hand Clin 2007;23:269-78, vii. (Pubitemid 46843496)
    • (2007) Hand Clinics , vol.23 , Issue.2 , pp. 269-278
    • Noelle Larson, A.1    Rizzo, M.2
  • 6
    • 0036130725 scopus 로고    scopus 로고
    • Volar fixation for dorsally displaced fractures of the distal radius: A preliminary report
    • DOI 10.1053/jhsu.2002.32081
    • Orbay JL, Fernandez DL. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg 2002;27:205-15. (Pubitemid 34241185)
    • (2002) Journal of Hand Surgery , vol.27 , Issue.2 , pp. 205-215
    • Orbay, J.L.1    Fernandez, D.L.2
  • 7
    • 34248229716 scopus 로고    scopus 로고
    • Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate
    • DOI 10.1097/BOT.0b013e318059b993, PII 0000513120070500000005
    • Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 2007;21:316-22. (Pubitemid 46718027)
    • (2007) Journal of Orthopaedic Trauma , vol.21 , Issue.5 , pp. 316-322
    • Arora, R.1    Lutz, M.2    Hennerbichler, A.3    Krappinger, D.4    Espen, D.5    Gabl, M.6
  • 8
    • 33845734224 scopus 로고    scopus 로고
    • Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures
    • DOI 10.1302/0301-620X.88B12.17696
    • Al-Rashid M, Theivendran K, Craigen MAC. Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures. J Bone Joint Surg Br 2006;88:1610-2. (Pubitemid 44970689)
    • (2006) Journal of Bone and Joint Surgery - Series B , vol.88 , Issue.12 , pp. 1610-1612
    • Al-Rashid, M.1    Theivendran, K.2    Craigen, M.A.C.3
  • 10
    • 0038651175 scopus 로고    scopus 로고
    • Osteosynthesis of distal radial fractures with a volar locking screw plate system
    • Drobetz H, Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 2003;27:1-6. (Pubitemid 36692843)
    • (2003) International Orthopaedics , vol.27 , Issue.1 , pp. 1-6
    • Drobetz, H.1    Kutscha-Lissberg, E.2
  • 11
    • 0242336574 scopus 로고    scopus 로고
    • Fixation of distal radius fractures using AO titanium volar distal radius plate
    • Lee HC, Wong YS, Chan BK, Low CO. Fixation of distal radius fractures using AO titanium volar distal radius plate. Hand Surg 2003;8:7-15.
    • (2003) Hand Surg. , vol.8 , pp. 7-15
    • Lee, H.C.1    Wong, Y.S.2    Chan, B.K.3    Low, C.O.4
  • 13
    • 0024835736 scopus 로고
    • Rupture of extensor pollicis longus following fixation of a distal radius fracture
    • DOI 10.1016/0020-1383(89)90019-3
    • Wong-Chung J, Quinlan W. Rupture of extensor pollicis longus following fixation of a distal radius fracture. Injury 1989;20:375-6. (Pubitemid 20019351)
    • (1989) Injury , vol.20 , Issue.6 , pp. 375-376
    • Wong-Chung, J.1    Quinlan, W.2
  • 14
    • 0025216870 scopus 로고
    • Clinical and microangiographic studies on rupture of the E.P.L. tendon after distal radial fractures
    • Hirasawa Y, Katsumi Y, Akiyoshi T, Tamai K, Tokioka T. Clinical and microangiographic studies on rupture of the E. P. L. tendon after distal radial fractures. J Hand Surg 1990;15:51-7. (Pubitemid 20125498)
    • (1990) Journal of Hand Surgery , vol.15 B , Issue.1 , pp. 51-57
    • Hirasawa, Y.1    Katsumi, Y.2    Akiyoshi, T.3    Tamai, K.4    Tokioka, T.5
  • 15
    • 34547581677 scopus 로고    scopus 로고
    • Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: A cadaveric study
    • Maschke SD, Evans PJ, Schub D, Drake R, Lawton JN. Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study. Hand 2007;2:144-50.
    • (2007) Hand , vol.2 , pp. 144-150
    • Maschke, S.D.1    Evans, P.J.2    Schub, D.3    Drake, R.4    Lawton, J.N.5
  • 16
    • 66649094469 scopus 로고    scopus 로고
    • Perforation of the third extensor compartment by the drill bit during palmar plating of the distal radius
    • Pichler W, Grechenig W, Clement H, Windisch G, Tesch NP. Perforation of the third extensor compartment by the drill bit during palmar plating of the distal radius. J Hand Surg Eur 2009;34:333-5.
    • (2009) J. Hand Surg. Eur. , vol.34 , pp. 333-335
    • Pichler, W.1    Grechenig, W.2    Clement, H.3    Windisch, G.4    Tesch, N.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.