메뉴 건너뛰기




Volumn 71, Issue , 2015, Pages 76-81

Comparison of the bioMérieux NucliSENS EasyQ HIV-1 v2.0-HIV-1 RNA quantification assay versus Abbott RealTime HIV-1 and Roche Cobas TaqMan HIV-1 v2.0 on current epidemic HIV-1 variants

Author keywords

Genetic diversity; HIV 1; HIV O; Quantification; Viral load

Indexed keywords

VIRUS RNA;

EID: 84941565912     PISSN: 13866532     EISSN: 18735967     Source Type: Journal    
DOI: 10.1016/j.jcv.2015.08.007     Document Type: Article
Times cited : (17)

References (22)
  • 1
    • 79952414942 scopus 로고    scopus 로고
    • Global trends in molecular epidemiology of HIV-1 during 2000-2007
    • Hemelaar J., Gouws E., Ghys P.D., Osmanov S. Global trends in molecular epidemiology of HIV-1 during 2000-2007. AIDS 2011, 25:679-689.
    • (2011) AIDS , vol.25 , pp. 679-689
    • Hemelaar, J.1    Gouws, E.2    Ghys, P.D.3    Osmanov, S.4
  • 4
    • 35348823156 scopus 로고    scopus 로고
    • Human immunodeficiency virus type 1 (HIV-1) plasma load discrepancies between the Roche COBAS AMPLICOR HIV-1 MONITOR Version 1. 5 and the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 assays
    • Damond F., Roquebert B., Benard A., Collin G., Miceli M., Yeni P., Brun-Vezinet F., Descamps D. Human immunodeficiency virus type 1 (HIV-1) plasma load discrepancies between the Roche COBAS AMPLICOR HIV-1 MONITOR Version 1. 5 and the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 assays. J. Clin. Microbiol. 2007, 45:3436-3438.
    • (2007) J. Clin. Microbiol. , vol.45 , pp. 3436-3438
    • Damond, F.1    Roquebert, B.2    Benard, A.3    Collin, G.4    Miceli, M.5    Yeni, P.6    Brun-Vezinet, F.7    Descamps, D.8
  • 6
    • 70449625248 scopus 로고    scopus 로고
    • Clinical and resistance consequences of misquantification of plasma and cerebrospinal fluid human immunodeficiency virus type 1 (HIV-1) RNA in samples from an HIV-1 subtype G-infected patient
    • Delaugerre C., Denis B., Peytavin G., Palmer P., Mourez T., Le Goff J., Molina J.M., Simon F. Clinical and resistance consequences of misquantification of plasma and cerebrospinal fluid human immunodeficiency virus type 1 (HIV-1) RNA in samples from an HIV-1 subtype G-infected patient. J. Clin. Microbiol. 2009, 47:3763-3764.
    • (2009) J. Clin. Microbiol. , vol.47 , pp. 3763-3764
    • Delaugerre, C.1    Denis, B.2    Peytavin, G.3    Palmer, P.4    Mourez, T.5    Le Goff, J.6    Molina, J.M.7    Simon, F.8
  • 7
    • 84879759758 scopus 로고    scopus 로고
    • Non-M variants of human immunodeficiency virus type 1
    • Mourez T., Simon F., Plantier J.C. Non-M variants of human immunodeficiency virus type 1. Clin. Microbiol. Rev. 2013, 26:448-461.
    • (2013) Clin. Microbiol. Rev. , vol.26 , pp. 448-461
    • Mourez, T.1    Simon, F.2    Plantier, J.C.3
  • 10
    • 84878829535 scopus 로고    scopus 로고
    • Comparison of the NucliSENS EasyQ HIV -1 v2. 0 with Abbott m2000rt RealTime HIV -1 assay for plasma RNA quantitation in different HIV -1 subtypes
    • Gomes P., Carvalho A.P., Diogo I., Goncalves F., Costa I., Cabanas J., Camacho R.J. Comparison of the NucliSENS EasyQ HIV -1 v2. 0 with Abbott m2000rt RealTime HIV -1 assay for plasma RNA quantitation in different HIV -1 subtypes. J. Virol. Methods 2013.
    • (2013) J. Virol. Methods
    • Gomes, P.1    Carvalho, A.P.2    Diogo, I.3    Goncalves, F.4    Costa, I.5    Cabanas, J.6    Camacho, R.J.7
  • 12
    • 83355166801 scopus 로고    scopus 로고
    • Comparison between the automated Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test version 2.0 assay and its version 1 and Nuclisens HIV-1 EasyQ version 2.0 assays when measuring diverse HIV-1 genotypes in China
    • Xu S., Song A., Nie J., Li X., Meng S., Zhang C., Wang Y. Comparison between the automated Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test version 2.0 assay and its version 1 and Nuclisens HIV-1 EasyQ version 2.0 assays when measuring diverse HIV-1 genotypes in China. J. Clin. Virol. 2012, 53:33-37.
    • (2012) J. Clin. Virol. , vol.53 , pp. 33-37
    • Xu, S.1    Song, A.2    Nie, J.3    Li, X.4    Meng, S.5    Zhang, C.6    Wang, Y.7
  • 17
    • 67650021214 scopus 로고    scopus 로고
    • Evaluation of the Abbott m2000 RealTime human immunodeficiency virus type 1 (HIV-1) assay for HIV load monitoring in South Africa compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 assays
    • Scott L.E., Noble L.D., Moloi J., Erasmus L., Venter W.D., Stevens W. Evaluation of the Abbott m2000 RealTime human immunodeficiency virus type 1 (HIV-1) assay for HIV load monitoring in South Africa compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 assays. J. Clin. Microbiol. 2009, 47:2209-2217.
    • (2009) J. Clin. Microbiol. , vol.47 , pp. 2209-2217
    • Scott, L.E.1    Noble, L.D.2    Moloi, J.3    Erasmus, L.4    Venter, W.D.5    Stevens, W.6
  • 18
    • 23744440598 scopus 로고    scopus 로고
    • Impact of human immunodeficiency virus type 1 (HIV-1) genetic diversity on performance of four commercial viral load assays: LCx HIV RNA Quantitative, AMPLICOR HIV-1 MONITOR v1. 5, VERSANT HIV-1 RNA 3. 0, and NucliSens HIV-1 QT
    • Swanson P., de Mendoza C., Joshi Y., Golden A., Hodinka R.L., Soriano V., Devare S.G., Hackett J. Impact of human immunodeficiency virus type 1 (HIV-1) genetic diversity on performance of four commercial viral load assays: LCx HIV RNA Quantitative, AMPLICOR HIV-1 MONITOR v1. 5, VERSANT HIV-1 RNA 3. 0, and NucliSens HIV-1 QT. J. Clin. Microbiol. 2005, 43:3860-3868.
    • (2005) J. Clin. Microbiol. , vol.43 , pp. 3860-3868
    • Swanson, P.1    de Mendoza, C.2    Joshi, Y.3    Golden, A.4    Hodinka, R.L.5    Soriano, V.6    Devare, S.G.7    Hackett, J.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.