메뉴 건너뛰기




Volumn 30, Issue 9, 2015, Pages 1561-1564

The Accuracy of a Mechanical Cup Alignment Guide in Total Hip Arthroplasty (THA) Through Direct Anterior and Posterior Approaches Measured with CT-Based Navigation

Author keywords

CT based navigation; Cup alignment; Mechanical cup alignment guide; Surgical approach; Surgical position; Total hip arthroplasty

Indexed keywords

ACCURACY; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DIRECT ANTERIOR APPROACH; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; MECHANICAL CUP ALIGNMENT GUIDE; MUSCULOSKELETAL PROCEDURE; PATIENT POSITIONING; POSTERIOR APPROACH; PREOPERATIVE PERIOD; SUPINE POSITION; SURGICAL TECHNIQUE; TOTAL HIP PROSTHESIS; ADULT; AGED; COMPUTER ASSISTED SURGERY; HIP PROSTHESIS; HIP REPLACEMENT; MIDDLE AGED; PROCEDURES; REPRODUCIBILITY; VERY ELDERLY;

EID: 84941024973     PISSN: 08835403     EISSN: 15328406     Source Type: Journal    
DOI: 10.1016/j.arth.2015.04.011     Document Type: Article
Times cited : (28)

References (19)
  • 1
    • 20444399895 scopus 로고    scopus 로고
    • Impingement in total hip arthroplasty a study of retrieved acetabular components
    • Shon W.Y., Baldini T., Peterson M.G., et al. Impingement in total hip arthroplasty a study of retrieved acetabular components. J Arthroplasty 2005, 20:427.
    • (2005) J Arthroplasty , vol.20 , pp. 427
    • Shon, W.Y.1    Baldini, T.2    Peterson, M.G.3
  • 2
    • 57649088878 scopus 로고    scopus 로고
    • Effect of reduced diameter neck stem on incidence of radiographic cup loosening and revisions in Charnley low-frictional torque arthroplasty
    • Wroblewski B.M., Siney P.D., Fleming P.A. Effect of reduced diameter neck stem on incidence of radiographic cup loosening and revisions in Charnley low-frictional torque arthroplasty. J Arthroplasty 2009, 24:10.
    • (2009) J Arthroplasty , vol.24 , pp. 10
    • Wroblewski, B.M.1    Siney, P.D.2    Fleming, P.A.3
  • 3
    • 1242319991 scopus 로고    scopus 로고
    • Influence of component position on dislocation: computed tomographic evaluation in a consecutive series of total hip arthroplasty
    • Nishii T., Sugano N., Miki H., et al. Influence of component position on dislocation: computed tomographic evaluation in a consecutive series of total hip arthroplasty. J Arthroplasty 2004, 19:162.
    • (2004) J Arthroplasty , vol.19 , pp. 162
    • Nishii, T.1    Sugano, N.2    Miki, H.3
  • 4
    • 34249805397 scopus 로고    scopus 로고
    • Mid-term results of cementless total hip arthroplasty using a ceramic-on-ceramic bearing with and without computer navigation
    • Sugano N., Nishii T., Miki H., et al. Mid-term results of cementless total hip arthroplasty using a ceramic-on-ceramic bearing with and without computer navigation. J Bone Joint Surg Br 2007, 89:455.
    • (2007) J Bone Joint Surg Br , vol.89 , pp. 455
    • Sugano, N.1    Nishii, T.2    Miki, H.3
  • 5
    • 84859911613 scopus 로고    scopus 로고
    • Does CT-based navigation improve the long-term survival in ceramic-on-ceramic THA?
    • Sugano N., Takao M., Sakai T., et al. Does CT-based navigation improve the long-term survival in ceramic-on-ceramic THA?. Clin Orthop Relat Res 2012, 27:736.
    • (2012) Clin Orthop Relat Res , vol.27 , pp. 736
    • Sugano, N.1    Takao, M.2    Sakai, T.3
  • 6
    • 4444305327 scopus 로고    scopus 로고
    • Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement
    • Jolles B.M., Genoud P., Hoffmeyer P. Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement. Clin Orthop Relat Res 2004, 426:174.
    • (2004) Clin Orthop Relat Res , vol.426 , pp. 174
    • Jolles, B.M.1    Genoud, P.2    Hoffmeyer, P.3
  • 7
    • 34250626073 scopus 로고    scopus 로고
    • Poor accuracy of freehand cup positioning during total hip arthroplasty
    • Bosker B.H., Verheyen C.C.P.M., Horstmann W.G., et al. Poor accuracy of freehand cup positioning during total hip arthroplasty. Arch Orthop Trauma Surg 2007, 127:375.
    • (2007) Arch Orthop Trauma Surg , vol.127 , pp. 375
    • Bosker, B.H.1    Verheyen, C.C.P.M.2    Horstmann, W.G.3
  • 8
    • 78951483217 scopus 로고    scopus 로고
    • The John Charnley Award. Risk factors for cup malpositioning quality improvement through a joint registry at a tertiary hospital
    • Collanan M.C., Jarrett B., Bragdon C.R., et al. The John Charnley Award. Risk factors for cup malpositioning quality improvement through a joint registry at a tertiary hospital. Clin Orthop Relat Res 2011, 469:319.
    • (2011) Clin Orthop Relat Res , vol.469 , pp. 319
    • Collanan, M.C.1    Jarrett, B.2    Bragdon, C.R.3
  • 9
    • 84855540752 scopus 로고    scopus 로고
    • Effect of pelvic obliquity on the orientation of the acetabular component in total hip arthroplasty
    • Zhou X., Wang Q., Zhang X., et al. Effect of pelvic obliquity on the orientation of the acetabular component in total hip arthroplasty. J Arthroplasty 2012, 27:299.
    • (2012) J Arthroplasty , vol.27 , pp. 299
    • Zhou, X.1    Wang, Q.2    Zhang, X.3
  • 10
    • 0033965848 scopus 로고    scopus 로고
    • Primary total hip arthroplasty in patients with ankylosing spondylitis
    • Tang W.M., Chiu K.Y. Primary total hip arthroplasty in patients with ankylosing spondylitis. J Arthroplasty 2000, 15:52.
    • (2000) J Arthroplasty , vol.15 , pp. 52
    • Tang, W.M.1    Chiu, K.Y.2
  • 11
    • 0036220612 scopus 로고    scopus 로고
    • Comparison of a mechanical acetabular alignment guide with computer placement of the socket
    • DiGioia A.M., Jaramaz B., Plakseychuk A.Y., et al. Comparison of a mechanical acetabular alignment guide with computer placement of the socket. J Arthroplasty 2002, 17:359.
    • (2002) J Arthroplasty , vol.17 , pp. 359
    • DiGioia, A.M.1    Jaramaz, B.2    Plakseychuk, A.Y.3
  • 12
    • 73349131084 scopus 로고    scopus 로고
    • Enhanced early outcome with the anterior supine intermuscular approach in primary total hip arthroplasty
    • Bernard K.R., Lombardi A.V., Seng B.E., et al. Enhanced early outcome with the anterior supine intermuscular approach in primary total hip arthroplasty. J Bone Joint Surg Am 2009, 91:107.
    • (2009) J Bone Joint Surg Am , vol.91 , pp. 107
    • Bernard, K.R.1    Lombardi, A.V.2    Seng, B.E.3
  • 13
    • 84865376463 scopus 로고    scopus 로고
    • A fluoroscopic grid in supine total hip arthroplasty. Improving cup positioning, limb length, and hip offset
    • Gililland J.M., Anderson L.A., Boffeli S.L., et al. A fluoroscopic grid in supine total hip arthroplasty. Improving cup positioning, limb length, and hip offset. J Arthroplasty 2012, 27:111.
    • (2012) J Arthroplasty , vol.27 , pp. 111
    • Gililland, J.M.1    Anderson, L.A.2    Boffeli, S.L.3
  • 14
    • 67650745609 scopus 로고    scopus 로고
    • A clinical comparative study of the direct Anterior with mini-posterior approach
    • Nakata K., Nishikawa M., Yamamoto K., et al. A clinical comparative study of the direct Anterior with mini-posterior approach. J Arthroplasty 2009, 24:698.
    • (2009) J Arthroplasty , vol.24 , pp. 698
    • Nakata, K.1    Nishikawa, M.2    Yamamoto, K.3
  • 15
    • 0017859205 scopus 로고
    • Dislocations after total hip-replacement arthroplasties
    • Lewinnek G.E., Lewis J.L., Tarr R., et al. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 1978, 60:217.
    • (1978) J Bone Joint Surg Am , vol.60 , pp. 217
    • Lewinnek, G.E.1    Lewis, J.L.2    Tarr, R.3
  • 16
    • 67649415127 scopus 로고    scopus 로고
    • Comparison of mini-incision total hip arthroplasty through an anterior approach and a posterior approach using navigation
    • Sugano N., Takao M., Sakai T., et al. Comparison of mini-incision total hip arthroplasty through an anterior approach and a posterior approach using navigation. Orthop Clin North Am 2009, 40:365.
    • (2009) Orthop Clin North Am , vol.40 , pp. 365
    • Sugano, N.1    Takao, M.2    Sakai, T.3
  • 17
    • 34848905651 scopus 로고    scopus 로고
    • Anatomic hip range of motion after implantation during total hip arthroplasty as measured by a navigation system
    • Miki H., Yamanashi W., Nishii T., et al. Anatomic hip range of motion after implantation during total hip arthroplasty as measured by a navigation system. J Arthroplasty 2007, 22(7):946.
    • (2007) J Arthroplasty , vol.22 , Issue.7 , pp. 946
    • Miki, H.1    Yamanashi, W.2    Nishii, T.3
  • 18
    • 0035708295 scopus 로고    scopus 로고
    • Accuracy evaluation of surface-based registration method in a computer navigation system for hip surgery performed through a posterolateral approach
    • Sugano N., Sasama T., Sato Y., et al. Accuracy evaluation of surface-based registration method in a computer navigation system for hip surgery performed through a posterolateral approach. Comput Aided Surg 2001, 6:195.
    • (2001) Comput Aided Surg , vol.6 , pp. 195
    • Sugano, N.1    Sasama, T.2    Sato, Y.3
  • 19
    • 0027479381 scopus 로고
    • The definition and measurement of acetabular orientation
    • Murray D.W. The definition and measurement of acetabular orientation. J Bone Joint Surg Br 1993, 75:228.
    • (1993) J Bone Joint Surg Br , vol.75 , pp. 228
    • Murray, D.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.