메뉴 건너뛰기




Volumn 27, Issue 5, 2012, Pages 736-741

Eleven- to 14-year Follow-up Results of Cementless Total Hip Arthroplasty Using a Third-generation Alumina Ceramic-on-ceramic Bearing

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BONE GROWTH; CEMENTLESS TOTAL HIP ARTHROPLASTY; CERAMIC PROSTHESIS; FEMALE; FOLLOW UP; FRACTURE FIXATION; HIP OSTEOARTHRITIS; HUMAN; MAJOR CLINICAL STUDY; MALE; MEDICAL RECORD REVIEW; OSTEOLYSIS; OUTCOME ASSESSMENT; RADIOGRAPHY; SURVIVAL; THIRD GENERATION ALUMINA CERAMIC ON CERAMIC BEARING; TOTAL HIP PROSTHESIS; TREATMENT OUTCOME;

EID: 84859911613     PISSN: 08835403     EISSN: 15328406     Source Type: Journal    
DOI: 10.1016/j.arth.2011.08.017     Document Type: Article
Times cited : (52)

References (39)
  • 2
    • 0023929687 scopus 로고
    • Mittelmeier ceramic total hip arthroplasty. A retrospective study
    • O'Leary J.F., Mallory T.H., Kraus T.J., et al. Mittelmeier ceramic total hip arthroplasty. A retrospective study. J Arthroplasty 1988, 3:87.
    • (1988) J Arthroplasty , vol.3 , pp. 87
    • O'Leary, J.F.1    Mallory, T.H.2    Kraus, T.J.3
  • 3
    • 0029851088 scopus 로고    scopus 로고
    • Total hip replacements using the ceramic Mittelmeier prosthesis
    • Huo M.H., Martin R.P., Zatorski L.E., et al. Total hip replacements using the ceramic Mittelmeier prosthesis. Clin Orthop 1996, 332:143.
    • (1996) Clin Orthop , vol.332 , pp. 143
    • Huo, M.H.1    Martin, R.P.2    Zatorski, L.E.3
  • 4
    • 0036056821 scopus 로고    scopus 로고
    • Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study
    • Hamadouche M., Boutin P., Daussange J., et al. Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am 2002, 84-A:69.
    • (2002) J Bone Joint Surg Am , pp. 69
    • Hamadouche, M.1    Boutin, P.2    Daussange, J.3
  • 5
    • 0033781822 scopus 로고    scopus 로고
    • Ceramic femoral head retrieval data
    • Willmann G. Ceramic femoral head retrieval data. Clin Orthop Relat Res 2000, 379:22.
    • (2000) Clin Orthop Relat Res , vol.379 , pp. 22
    • Willmann, G.1
  • 6
    • 0025295098 scopus 로고
    • Alumina-on-alumina hip replacement. Results and survivorship in young patients
    • Sedel L., Kerboull L., Christel P., et al. Alumina-on-alumina hip replacement. Results and survivorship in young patients. J Bone Joint Surg Br 1990, 72:658.
    • (1990) J Bone Joint Surg Br , vol.72 , pp. 658
    • Sedel, L.1    Kerboull, L.2    Christel, P.3
  • 7
    • 1642284142 scopus 로고    scopus 로고
    • Hybrid alumina total hip arthroplasty using a press-fit metal-backed socket in patients younger than 55 years. A six- to 11-year evaluation
    • Bizot P., Hannouche D., Nizard R., et al. Hybrid alumina total hip arthroplasty using a press-fit metal-backed socket in patients younger than 55 years. A six- to 11-year evaluation. J Bone Joint Surg Br 2004, 86:190.
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 190
    • Bizot, P.1    Hannouche, D.2    Nizard, R.3
  • 8
    • 33749452742 scopus 로고    scopus 로고
    • Custom made femoral components with blasted surface for congenital hip dysplasia
    • Sakai T., Sugano N., Ohzono K., et al. Custom made femoral components with blasted surface for congenital hip dysplasia. ClinOrthop 2006, 451:146.
    • (2006) ClinOrthop , vol.451 , pp. 146
    • Sakai, T.1    Sugano, N.2    Ohzono, K.3
  • 9
    • 0036195028 scopus 로고    scopus 로고
    • Femoral anteversion, femoral offset, and abductor lever arm after total hip arthroplasty using a modular femoral neck system
    • Sakai T., Sugano N., Ohzono K., et al. Femoral anteversion, femoral offset, and abductor lever arm after total hip arthroplasty using a modular femoral neck system. J OrthopSci 2002, 7:62.
    • (2002) J OrthopSci , vol.7 , pp. 62
    • Sakai, T.1    Sugano, N.2    Ohzono, K.3
  • 10
    • 0027479381 scopus 로고
    • The definition and measurement of acetabular orientation
    • Murray D.W. The definition and measurement of acetabular orientation. J Bone Joint Surg [Br] 1993, 75-B:228.
    • (1993) J Bone Joint Surg [Br] , pp. 228
    • Murray, D.W.1
  • 11
    • 77049159486 scopus 로고
    • Functional results of hip arthroplasty with acrylic prosthesis
    • Merle d'Aubigne R., Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg [Am] 1954, 36-A:451.
    • (1954) J Bone Joint Surg [Am] , pp. 451
    • Merle d'Aubigne, R.1    Postel, M.2
  • 12
    • 0025695691 scopus 로고
    • The case for porous-coated hip implants: the femoral side
    • Engh C.A., Glassman A.H., Suthers K.E. The case for porous-coated hip implants: the femoral side. ClinOrthop 1990, 261:63.
    • (1990) ClinOrthop , vol.261 , pp. 63
    • Engh, C.A.1    Glassman, A.H.2    Suthers, K.E.3
  • 13
    • 0023946442 scopus 로고
    • The uncemented porous-coated anatomic total hip prosthesis: two-year results of a prospective consecutive series
    • Callaghan J.J., Dysart S.H., Savory C.G. The uncemented porous-coated anatomic total hip prosthesis: two-year results of a prospective consecutive series. J Bone Joint Surg[Am] 1988, 70-A:337.
    • (1988) J Bone Joint Surg[Am] , pp. 337
    • Callaghan, J.J.1    Dysart, S.H.2    Savory, C.G.3
  • 14
    • 0018687995 scopus 로고
    • "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening
    • Gruen T.A., McNeice G.M., Amstutz H.C. "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Lin Orthop Relat Res 1979, 141:17.
    • (1979) Lin Orthop Relat Res , vol.141 , pp. 17
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 15
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacement
    • DeLee J.G., Charnley J. Radiological demarcation of cemented sockets in total hip replacement. ClinOrthop 1976, 121:20.
    • (1976) ClinOrthop , vol.121 , pp. 20
    • DeLee, J.G.1    Charnley, J.2
  • 16
    • 0028956936 scopus 로고
    • Patterns of osteolysis around total hip components inserted with and without cement
    • Zicat B., Engh C.A., Gokcen E. Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg Am 1995, 77:432.
    • (1995) J Bone Joint Surg Am , vol.77 , pp. 432
    • Zicat, B.1    Engh, C.A.2    Gokcen, E.3
  • 17
    • 0018236976 scopus 로고
    • Changes in the upper femur after low friction arthroplasty
    • Blacker G.J., Charnley J. Changes in the upper femur after low friction arthroplasty. ClinOrthopRelat Res 1978, 137:15.
    • (1978) ClinOrthopRelat Res , vol.137 , pp. 15
    • Blacker, G.J.1    Charnley, J.2
  • 18
    • 0017859205 scopus 로고
    • Dislocations after total hip-replacement arthroplasties
    • Lewinnek G.E., Lewis J.L., Tarr R., et al. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg[Am] 1978, 60-A:217.
    • (1978) J Bone Joint Surg[Am] , pp. 217
    • Lewinnek, G.E.1    Lewis, J.L.2    Tarr, R.3
  • 19
    • 34249805397 scopus 로고    scopus 로고
    • Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation
    • Sugano N., Nishii T., Miki H., et al. Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation. J Bone Joint Surg Br 2007, 89:455.
    • (2007) J Bone Joint Surg Br , vol.89 , pp. 455
    • Sugano, N.1    Nishii, T.2    Miki, H.3
  • 20
    • 34249933860 scopus 로고    scopus 로고
    • Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation
    • Walter W.L., O'Toole G.C., Walter W.K., et al. Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. J Arthroplasty 2007, 22:496.
    • (2007) J Arthroplasty , vol.22 , pp. 496
    • Walter, W.L.1    O'Toole, G.C.2    Walter, W.K.3
  • 21
    • 48949118899 scopus 로고    scopus 로고
    • The noisy ceramic hip: is component malpositioning the cause?
    • Restrepo C., Parvizi J., Kurtz S.M., et al. The noisy ceramic hip: is component malpositioning the cause?. J Arthroplasty 2008, 23:643.
    • (2008) J Arthroplasty , vol.23 , pp. 643
    • Restrepo, C.1    Parvizi, J.2    Kurtz, S.M.3
  • 22
    • 38949162593 scopus 로고    scopus 로고
    • A rare complication of ceramic-on-ceramic bearings in total hip arthroplasty
    • Rosneck J., Klika A., Barsoum W. A rare complication of ceramic-on-ceramic bearings in total hip arthroplasty. J Arthroplasty 2008, 23:311.
    • (2008) J Arthroplasty , vol.23 , pp. 311
    • Rosneck, J.1    Klika, A.2    Barsoum, W.3
  • 23
    • 33645658517 scopus 로고    scopus 로고
    • Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing
    • Park Y.S., Hwang S.K., Choy W.S., et al. Ceramic failure after total hip arthroplasty with an alumina-on-alumina bearing. J Bone Joint Surg Am 2006, 88:780.
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 780
    • Park, Y.S.1    Hwang, S.K.2    Choy, W.S.3
  • 24
    • 33846850269 scopus 로고    scopus 로고
    • Failure analysis of a ceramic bearing acetabular component
    • Poggie R.A., Turgeon T.R., Coutts R.D. Failure analysis of a ceramic bearing acetabular component. J Bone Joint Surg Am 2007, 89:367.
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 367
    • Poggie, R.A.1    Turgeon, T.R.2    Coutts, R.D.3
  • 25
    • 38949161946 scopus 로고    scopus 로고
    • Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty
    • Koo K.H., Ha Y.C., Jung W.H., et al. Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty. J Bone Joint Surg Am 2008, 90:329.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 329
    • Koo, K.H.1    Ha, Y.C.2    Jung, W.H.3
  • 26
    • 21844437667 scopus 로고    scopus 로고
    • Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study
    • D'Antonio J., Capello W., Manley M., et al. Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study. Clin Orthop Relat Res 2005, 436:164.
    • (2005) Clin Orthop Relat Res , vol.436 , pp. 164
    • D'Antonio, J.1    Capello, W.2    Manley, M.3
  • 27
    • 14644387578 scopus 로고    scopus 로고
    • Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study
    • Yoo J.J., Kim Y.M., Yoon K.S., et al. Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study. J Bone Joint Surg Am 2005, 87:530.
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 530
    • Yoo, J.J.1    Kim, Y.M.2    Yoon, K.S.3
  • 28
    • 33845411069 scopus 로고    scopus 로고
    • Two- to 9-year clinical results of alumina ceramic-on-ceramic THA
    • Murphy S.B., Ecker T.M., Tannast M. Two- to 9-year clinical results of alumina ceramic-on-ceramic THA. Clin Orthop Relat Res 2006, 453:97.
    • (2006) Clin Orthop Relat Res , vol.453 , pp. 97
    • Murphy, S.B.1    Ecker, T.M.2    Tannast, M.3
  • 29
    • 36849075129 scopus 로고    scopus 로고
    • Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty
    • Lusty P.J., Tai C.C., Sew-Hoy R.P., et al. Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty. J Bone Joint Surg Am 2007, 89:2676.
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 2676
    • Lusty, P.J.1    Tai, C.C.2    Sew-Hoy, R.P.3
  • 30
    • 44649167688 scopus 로고    scopus 로고
    • Cementless total hip arthroplasty with alumina bearings in patients younger than fifty with femoral head osteonecrosis
    • Baek S.H., Kim S.Y. Cementless total hip arthroplasty with alumina bearings in patients younger than fifty with femoral head osteonecrosis. J Bone Joint Surg Am 2008, 90:1314.
    • (2008) J Bone Joint Surg Am , vol.90 , pp. 1314
    • Baek, S.H.1    Kim, S.Y.2
  • 31
    • 33745961250 scopus 로고    scopus 로고
    • Cobalt-chromium head wear following revision hip arthroplasty performed after ceramic fracture-a case report
    • Hasegawa M., Sudo A., Uchida A. Cobalt-chromium head wear following revision hip arthroplasty performed after ceramic fracture-a case report. Acta Orthop 2006, 77:833.
    • (2006) Acta Orthop , vol.77 , pp. 833
    • Hasegawa, M.1    Sudo, A.2    Uchida, A.3
  • 32
    • 0031034439 scopus 로고    scopus 로고
    • Fracture of a ceramic femoral head after a revision operation. A case report
    • Pulliam I.T., Trousdale R.T. Fracture of a ceramic femoral head after a revision operation. A case report. J Bone Joint Surg Am 1997, 79:118.
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 118
    • Pulliam, I.T.1    Trousdale, R.T.2
  • 33
    • 77954650706 scopus 로고    scopus 로고
    • Early failure of a modular femoral neck total hip arthroplasty component: a case report
    • Wilson D.A., Dunbar M.J., Amirault J.D., et al. Early failure of a modular femoral neck total hip arthroplasty component: a case report. J Bone Joint Surg Am 2010, 92:1514.
    • (2010) J Bone Joint Surg Am , vol.92 , pp. 1514
    • Wilson, D.A.1    Dunbar, M.J.2    Amirault, J.D.3
  • 34
    • 77954647496 scopus 로고    scopus 로고
    • Fracture of a modular femoral neck after total hip arthroplasty: a case report
    • Wright G., Sporer S., Urban R., et al. Fracture of a modular femoral neck after total hip arthroplasty: a case report. J Bone Joint Surg Am 2010, 92:1518.
    • (2010) J Bone Joint Surg Am , vol.92 , pp. 1518
    • Wright, G.1    Sporer, S.2    Urban, R.3
  • 35
    • 77954654247 scopus 로고    scopus 로고
    • Corrosion-induced fracture of a double-modular hip prosthesis: a case report
    • Atwood S.A., Patten E.W., Bozic K.J., et al. Corrosion-induced fracture of a double-modular hip prosthesis: a case report. J Bone Joint Surg Am 2010, 92:1522.
    • (2010) J Bone Joint Surg Am , vol.92 , pp. 1522
    • Atwood, S.A.1    Patten, E.W.2    Bozic, K.J.3
  • 36
    • 77953157562 scopus 로고    scopus 로고
    • Modular femoral neck and head system works well in cementless THA for developmental dysplasia of the hip
    • Sakai T., Ohzono K., Nishii T., et al. Modular femoral neck and head system works well in cementless THA for developmental dysplasia of the hip. J Bone Joint Surg Br 2010, 92:770.
    • (2010) J Bone Joint Surg Br , vol.92 , pp. 770
    • Sakai, T.1    Ohzono, K.2    Nishii, T.3
  • 37
    • 0029044314 scopus 로고
    • Polyethylene sockets and alumina ceramic heads in cemented total hip arthroplasty. A ten-year study
    • [Erratum in: J Bone Joint Surg Br 1995 Nov;77(6):985]
    • Sugano N., Nishii T., Nakata K., et al. Polyethylene sockets and alumina ceramic heads in cemented total hip arthroplasty. A ten-year study. J Bone Joint Surg Br 1995, 77:548. [Erratum in: J Bone Joint Surg Br 1995 Nov;77(6):985].
    • (1995) J Bone Joint Surg Br , vol.77 , pp. 548
    • Sugano, N.1    Nishii, T.2    Nakata, K.3
  • 38
    • 0033038236 scopus 로고    scopus 로고
    • Cytotoxicity and macrophage cytokine release induced by ceramic and polyethylene particles in vitro
    • Catelas I., Petit A., Marchand R., et al. Cytotoxicity and macrophage cytokine release induced by ceramic and polyethylene particles in vitro. J Bone Joint Surg Br 1999, 81:516.
    • (1999) J Bone Joint Surg Br , vol.81 , pp. 516
    • Catelas, I.1    Petit, A.2    Marchand, R.3
  • 39
    • 0037290074 scopus 로고    scopus 로고
    • Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro
    • Germain M.A., Hatton A., Williams S., et al. Comparison of the cytotoxicity of clinically relevant cobalt-chromium and alumina ceramic wear particles in vitro. Biomaterials 2003, 24:469.
    • (2003) Biomaterials , vol.24 , pp. 469
    • Germain, M.A.1    Hatton, A.2    Williams, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.