Quality Assurance in Bone Densitometry

Author keywords

Absorptiometry, photon; Health care; Osteoporosis; Quality assurance; Quality control; Radiation dosage; Radiation protection

Indexed keywords


EID: 84940270704     PISSN: None     EISSN: 21674825     Source Type: Journal    
DOI: 10.1007/s40134-013-0033-9     Document Type: Review
Times cited : (5)

References (28)
  • 1
    • 84885000875 scopus 로고    scopus 로고
    • Public health impact of osteoporosis
    • Cauley JA. Public health impact of osteoporosis. J Gerontol A. 2013;68:1243–51.
    • (2013) J Gerontol A , vol.68 , pp. 1243-1251
    • Cauley, J.A.1
  • 2
    • 85062745514 scopus 로고    scopus 로고
    • World Health Organization. Assessment of osteoporosis at the primary health care level. Summary Report of a WHO Scientific Group. Accessed 2007.
    • World Health Organization. Assessment of osteoporosis at the primary health care level. Summary Report of a WHO Scientific Group. www.who.int/chp/topics/rheumatic/en/index.html. Accessed 2007.
  • 3
    • 33750209491 scopus 로고    scopus 로고
    • An estimate of the worldwide prevalence and disability associated with osteoporotic fractures
    • COI: 1:STN:280:DC%2BD28nitVSksQ%3D%3D, PID: 16983459
    • Johnell O, Kanis JA. An estimate of the worldwide prevalence and disability associated with osteoporotic fractures. Osteoporos Int. 2006;17:1726–33.
    • (2006) Osteoporos Int , vol.17 , pp. 1726-1733
    • Johnell, O.1    Kanis, J.A.2
  • 4
    • 0030791669 scopus 로고    scopus 로고
    • World-wide projections for hip fracture
    • COI: 1:STN:280:DyaK1c%2Fos1Kgtg%3D%3D, PID: 9425497
    • Gullberg B, Johnell O, Kanis JA. World-wide projections for hip fracture. Osteoporos Int. 1997;7:407–13.
    • (1997) Osteoporos Int , vol.7 , pp. 407-413
    • Gullberg, B.1    Johnell, O.2    Kanis, J.A.3
  • 5
    • 85062750714 scopus 로고    scopus 로고
    • International Osteoporosis Foundation. Accessed 2006.
    • International Osteoporosis Foundation. http://www.iofbonehealth.org/epidemiology. Accessed 2006.
  • 6
    • 0037129560 scopus 로고    scopus 로고
    • Epidemiology and outcomes of osteoporotic fractures
    • PID: 12049882
    • Cummings SR, Melton LJ. Epidemiology and outcomes of osteoporotic fractures. Lancet. 2002;359:1761–7.
    • (2002) Lancet , vol.359 , pp. 1761-1767
    • Cummings, S.R.1    Melton, L.J.2
  • 7
    • 84861324346 scopus 로고    scopus 로고
    • Osteoporosis imaging: state of the art and advanced imaging
    • PID: 22438439
    • Link TM. Osteoporosis imaging: state of the art and advanced imaging. Radiology. 2012;263:3–17.
    • (2012) Radiology , vol.263 , pp. 3-17
    • Link, T.M.1
  • 9
    • 57149116730 scopus 로고    scopus 로고
    • Common mistakes in the clinical use of bone mineral density testing
    • PID: 18936788
    • Lewiecki EM, Lane NE. Common mistakes in the clinical use of bone mineral density testing. Nat Clin Pract Rheumatol. 2008;4:667–74.
    • (2008) Nat Clin Pract Rheumatol , vol.4 , pp. 667-674
    • Lewiecki, E.M.1    Lane, N.E.2
  • 11
    • 84873712267 scopus 로고    scopus 로고
    • ∙∙ Guglielmi G, Damilakis J, Solomou G, Bazzocchi A. Quality assurance of imaging techniques used in the clinical management of osteoporosis. Radiol Med 2012;117:1347–54. This review is about the quality assurance procedures for densitometric and imaging techniques commonly used to diagnose and manage osteoporosis.
    • ∙∙ Guglielmi G, Damilakis J, Solomou G, Bazzocchi A. Quality assurance of imaging techniques used in the clinical management of osteoporosis. Radiol Med 2012;117:1347–54. This review is about the quality assurance procedures for densitometric and imaging techniques commonly used to diagnose and manage osteoporosis.
  • 12
    • 77957877373 scopus 로고    scopus 로고
    • ∙ Damilakis J, Adams JE, Guglielmi G, Link TM. Radiation exposure in X-ray-based imaging techniques used in osteoporosis. Eur Radiol. 2010;20:2707–14. This study provides information about the radiation exposure and radiation safety associated with the most commonly used X-ray-based imaging techniques in osteopososis.
    • ∙ Damilakis J, Adams JE, Guglielmi G, Link TM. Radiation exposure in X-ray-based imaging techniques used in osteoporosis. Eur Radiol. 2010;20:2707–14. This study provides information about the radiation exposure and radiation safety associated with the most commonly used X-ray-based imaging techniques in osteopososis.
  • 13
    • 85062746306 scopus 로고    scopus 로고
    • Clinical use of bone densitometry
    • Marcus R, Feldman D, Kelsey J, (eds), Academic Press, San Diego: chapter 59
    • Faulkner KG. Clinical use of bone densitometry. In: Marcus R, Feldman D, Kelsey J, editors. Osteoporosis, Two-Volume Set. 2nd ed. San Diego: Academic Press; 2001 chapter 59.
    • (2001) Osteoporosis, Two-Volume Set
    • Faulkner, K.G.1
  • 14
    • 41849114937 scopus 로고    scopus 로고
    • How important are BMD accuracy errors for the clinical interpretation of DXA scans?
    • PID: 18052754
    • Blake GM, Fogelman I. How important are BMD accuracy errors for the clinical interpretation of DXA scans? J Bone Miner Res. 2008;23:457–62.
    • (2008) J Bone Miner Res , vol.23 , pp. 457-462
    • Blake, G.M.1    Fogelman, I.2
  • 15
    • 77958475662 scopus 로고    scopus 로고
    • ∙ Hind K, Oldroyd B, Truscott JG. In vivo precision of the GE Lunar iDXA densitometer for the measurement of total-body, lumbar spine, and femoral bone mineral density in adults. J Clin Densitom. 2010;13:413–7. This study provides the precision for bone measurements acquired using the most recent DXA technology (Lunar iDXA) and the previous ones (Lunar Expert, Lunar Prodigy and Hologic).
    • ∙ Hind K, Oldroyd B, Truscott JG. In vivo precision of the GE Lunar iDXA densitometer for the measurement of total-body, lumbar spine, and femoral bone mineral density in adults. J Clin Densitom. 2010;13:413–7. This study provides the precision for bone measurements acquired using the most recent DXA technology (Lunar iDXA) and the previous ones (Lunar Expert, Lunar Prodigy and Hologic).
  • 16
    • 33644878009 scopus 로고    scopus 로고
    • Lentle BC: precision assessment and radiation safety for dual-energy X-ray absorptiometry: position paper of the International Society for Clinical Densitometry
    • PID: 16311420
    • Baim S, Wilson CR, Lewiecki EM, Luckey MM, Downs RW Jr. Lentle BC: precision assessment and radiation safety for dual-energy X-ray absorptiometry: position paper of the International Society for Clinical Densitometry. J Clin Densitom. 2005;8:371–8.
    • (2005) J Clin Densitom , vol.8 , pp. 371-378
    • Baim, S.1    Wilson, C.R.2    Lewiecki, E.M.3    Luckey, M.M.4    Downs, R.W.5
  • 17
    • 33749163080 scopus 로고    scopus 로고
    • Minimum sample size requirements for bone density precision assessment produce inconsistency in clinical monitoring
    • COI: 1:STN:280:DC%2BD28rotlagsQ%3D%3D, PID: 16900302
    • Leslie WD, Moayyeri A. Minimum sample size requirements for bone density precision assessment produce inconsistency in clinical monitoring. Osteoporos Int. 2006;17:1673–80.
    • (2006) Osteoporos Int , vol.17 , pp. 1673-1680
    • Leslie, W.D.1    Moayyeri, A.2
  • 18
    • 85062750260 scopus 로고    scopus 로고
    • ∙∙ International Society for Clinical Densitometry: 2013 ISCD Official Positions. Accessed 2013. The new official positions of the ISCD as updated in 2013 about phantom scanning, precision assessment and cross-calibration of DXA machines.
    • ∙∙ International Society for Clinical Densitometry: 2013 ISCD Official Positions. http://www.iscd.org/official-positions/2013-iscd-official-positions-adult/. Accessed 2013. The new official positions of the ISCD as updated in 2013 about phantom scanning, precision assessment and cross-calibration of DXA machines.
  • 19
    • 17144463967 scopus 로고
    • Standardization of measurements for assessing BMD by DXA
    • COI: 1:CAS:528:DyaK2MXps1aqsrg%3D, PID: 8581882
    • Steiger P. Standardization of measurements for assessing BMD by DXA. Calcif Tissue Int. 1995;57:469.
    • (1995) Calcif Tissue Int , vol.57 , pp. 469
    • Steiger, P.1
  • 20
    • 0031201603 scopus 로고    scopus 로고
    • Standardization of femur BMD
    • COI: 1:STN:280:DyaK2svgtleqtw%3D%3D, PID: 9258764
    • Hanson J. Standardization of femur BMD. J Bone Miner Res. 1997;12:1316–7.
    • (1997) J Bone Miner Res , vol.12 , pp. 1316-1317
    • Hanson, J.1
  • 21
    • 84864318068 scopus 로고    scopus 로고
    • Clinical observations in total body DXA: technical aspects of positioning and analysis
    • PID: 22321660
    • Libber J, Binkley N, Krueger D. Clinical observations in total body DXA: technical aspects of positioning and analysis. J Clin Densitom. 2012;15:282–9.
    • (2012) J Clin Densitom , vol.15 , pp. 282-289
    • Libber, J.1    Binkley, N.2    Krueger, D.3
  • 22
    • 84555187574 scopus 로고    scopus 로고
    • Simulated increases in body fat and errors in bone mineral density measurements by DXA and QCT
    • PID: 21915902
    • Yu EW, Thomas BJ, Brown JK, Finkelstein JS. Simulated increases in body fat and errors in bone mineral density measurements by DXA and QCT. J Bone Miner Res. 2012;27:119–24.
    • (2012) J Bone Miner Res , vol.27 , pp. 119-124
    • Yu, E.W.1    Thomas, B.J.2    Brown, J.K.3    Finkelstein, J.S.4
  • 23
    • 33749348458 scopus 로고    scopus 로고
    • Comparison of effective dose to children and adults from dual X-ray absorptiometry examinations
    • PID: 16376161
    • Blake GM, Naeem M, Boutros M. Comparison of effective dose to children and adults from dual X-ray absorptiometry examinations. Bone. 2006;38:935–42.
    • (2006) Bone , vol.38 , pp. 935-942
    • Blake, G.M.1    Naeem, M.2    Boutros, M.3
  • 24
    • 84655167641 scopus 로고    scopus 로고
    • The impact of recent technological advances on the trueness and precision of DXA to assess body composition
    • Toombs RJ, Ducher G, Shepherd JA, De Souza MJ. The impact of recent technological advances on the trueness and precision of DXA to assess body composition. Obesity (Silver Spring). 2012;20:30–9.
    • (2012) Obesity (Silver Spring) , vol.20 , pp. 30-39
    • Toombs, R.J.1    Ducher, G.2    Shepherd, J.A.3    De Souza, M.J.4
  • 25
    • 40949104442 scopus 로고    scopus 로고
    • ICRP publication 103
    • The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP. 2007;37:1–332.
    • (2007) Ann ICRP , vol.37 , pp. 1-332
  • 27
    • 33645223911 scopus 로고    scopus 로고
    • Commissioning and quality assurance protocol for dual energy X-ray absorptiometry (DEXA) systems
    • COI: 1:STN:280:DC%2BD287kvFCrsg%3D%3D
    • Sheahan NF, Dowling A, O’Reilly G, Malone JF. Commissioning and quality assurance protocol for dual energy X-ray absorptiometry (DEXA) systems. Radiat Prot Dosim. 2005;117:288–90.
    • (2005) Radiat Prot Dosim , vol.117 , pp. 288-290
    • Sheahan, N.F.1    Dowling, A.2    O’Reilly, G.3    Malone, J.F.4
  • 28
    • 85062745106 scopus 로고    scopus 로고
    • Radiation Protection of Patients. Staff Radiation Protection DXA. Accessed 2001.
    • Radiation Protection of Patients. Staff Radiation Protection DXA. https://rpop.iaea.org/RPOP/RPoP/Content/index.htm. Accessed 2001.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.