In vivo precision of the GE Lunar iDXA densitometer for the measurement of total-body, lumbar spine, and femoral bone mineral density in adults

Author keywords

BMD; Dual energy X ray absorptiometry; IDXA; Precision

Indexed keywords

ACCURACY; ADULT; ARTICLE; BODY MASS; BODY SIZE; BONE DENSITOMETRY; BONE DENSITY; DUAL ENERGY X RAY ABSORPTIOMETRY; FEMALE; FEMUR; FEMUR NECK; HIP; HUMAN; LINEAR REGRESSION ANALYSIS; LUMBAR SPINE; MALE; MEASUREMENT; MEDICAL INSTRUMENTATION; PRIORITY JOURNAL; REPRODUCIBILITY;

EID: 77958475662     PISSN: 10946950     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jocd.2010.06.002     Document Type: Article
Times cited : (59)

References (15)
  • 1
    • 0038280029 scopus 로고    scopus 로고
    • Need for precision studies at individual institutions and assessment of size of regions of interest on serial DXA scans
    • Morgan S.L., Abercrombie W., Lee J.Y. Need for precision studies at individual institutions and assessment of size of regions of interest on serial DXA scans. J Clin Densitom 2003, 6(2):97-101.
    • (2003) J Clin Densitom , vol.6 , Issue.2 , pp. 97-101
    • Morgan, S.L.1    Abercrombie, W.2    Lee, J.Y.3
  • 2
    • 42649112056 scopus 로고    scopus 로고
    • Official positions of the International Society for Clinical Densitometry and executive summary of the 2007 position development conference
    • Baim S., Blinkley N., Bilezikian L., et al. Official positions of the International Society for Clinical Densitometry and executive summary of the 2007 position development conference. J Clin Densitom 2008, 11(1):75-91.
    • (2008) J Clin Densitom , vol.11 , Issue.1 , pp. 75-91
    • Baim, S.1    Blinkley, N.2    Bilezikian, L.3
  • 3
    • 51749114236 scopus 로고    scopus 로고
    • Differences in precision in bone mineral density measured by SXA and DXA: the NOREPOS study
    • Forsen L., Berntsen G.K., Meyer H.E., et al. Differences in precision in bone mineral density measured by SXA and DXA: the NOREPOS study. Eur J Epidemiol 2008, 23(9):615-624.
    • (2008) Eur J Epidemiol , vol.23 , Issue.9 , pp. 615-624
    • Forsen, L.1    Berntsen, G.K.2    Meyer, H.E.3
  • 4
    • 34247596791 scopus 로고    scopus 로고
    • Comparisons of BMD precision for Prodigy and Delphi spine and femur scans
    • Shepherd J.A., Fan B., Lu Y., et al. Comparisons of BMD precision for Prodigy and Delphi spine and femur scans. Osteoporos Int 2006, 179:1305-1308.
    • (2006) Osteoporos Int , vol.179 , pp. 1305-1308
    • Shepherd, J.A.1    Fan, B.2    Lu, Y.3
  • 5
    • 53549129219 scopus 로고    scopus 로고
    • Improved precision with Hologic Apex software
    • Fan B., Lewiecki E.M., Sherman L. Improved precision with Hologic Apex software. Osteoporos Int 2008, 19(11):1597-1602.
    • (2008) Osteoporos Int , vol.19 , Issue.11 , pp. 1597-1602
    • Fan, B.1    Lewiecki, E.M.2    Sherman, L.3
  • 6
    • 33749163080 scopus 로고    scopus 로고
    • Minimum sample size requirements for bone density precision assessment produce inconsistency in clinical monitoring
    • Leslie W.D., Moayyeri A. Minimum sample size requirements for bone density precision assessment produce inconsistency in clinical monitoring. Osteoporos Int 2006, 17(11):1673-1680.
    • (2006) Osteoporos Int , vol.17 , Issue.11 , pp. 1673-1680
    • Leslie, W.D.1    Moayyeri, A.2
  • 7
    • 33644878009 scopus 로고    scopus 로고
    • Precision assessment and radiation safety for DXA: position paper of the International Society for Clinical Densitometry
    • Baim S., Wilson C.R., Lewiecki E.M., et al. Precision assessment and radiation safety for DXA: position paper of the International Society for Clinical Densitometry. J Clin Densitom 2005, 8(4):371-378.
    • (2005) J Clin Densitom , vol.8 , Issue.4 , pp. 371-378
    • Baim, S.1    Wilson, C.R.2    Lewiecki, E.M.3
  • 8
    • 0029112340 scopus 로고
    • Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques
    • Gluer C.C., Blake G., Lu Y., et al. Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques. Osteoporos Int 1995, 5:262-270.
    • (1995) Osteoporos Int , vol.5 , pp. 262-270
    • Gluer, C.C.1    Blake, G.2    Lu, Y.3
  • 9
    • 29044437090 scopus 로고    scopus 로고
    • Reproducibility of bone mineral density measurements using dual energy X-ray absorptiometry in daily clinical practice
    • El Maghraoui, Do Santos Zounon A.A., Jroundi I., et al. Reproducibility of bone mineral density measurements using dual energy X-ray absorptiometry in daily clinical practice. Osteoporos Int 2005, 16(12):1742-1748.
    • (2005) Osteoporos Int , vol.16 , Issue.12 , pp. 1742-1748
    • El Maghraoui1    Do Santos Zounon, A.A.2    Jroundi, I.3
  • 10
    • 0043025553 scopus 로고    scopus 로고
    • Cross calibration of GE/Lunar pencil and fan beam dual energy densitometers-bone mineral density and body composition studies
    • Oldroyd B., Smith A.H., Truscott J.G. Cross calibration of GE/Lunar pencil and fan beam dual energy densitometers-bone mineral density and body composition studies. Eur J Clin Nutr 2003, 57:977-987.
    • (2003) Eur J Clin Nutr , vol.57 , pp. 977-987
    • Oldroyd, B.1    Smith, A.H.2    Truscott, J.G.3
  • 11
    • 34848899539 scopus 로고    scopus 로고
    • Precision and accuracy of measuring changes in bone mineral density by dual energy X-ray absorptiometry
    • Tothill P., Hannan W.J. Precision and accuracy of measuring changes in bone mineral density by dual energy X-ray absorptiometry. Osteoporos Int 2007, 18(11):1515-1523.
    • (2007) Osteoporos Int , vol.18 , Issue.11 , pp. 1515-1523
    • Tothill, P.1    Hannan, W.J.2
  • 12
    • 77958460611 scopus 로고    scopus 로고
    • Comparison of total body parameters as measured using GE Healthcare Lunar Prodigy and Lunar iDXA densitometers
    • Krueger D.M., Checovich N., Vallarta-Ast D., et al. Comparison of total body parameters as measured using GE Healthcare Lunar Prodigy and Lunar iDXA densitometers. J Bone Mineral Res 2006, 21:SS225.
    • (2006) J Bone Mineral Res , vol.21
    • Krueger, D.M.1    Checovich, N.2    Vallarta-Ast, D.3
  • 13
    • 77958453673 scopus 로고    scopus 로고
    • Body composition precision with the Lunar iDXA. ISCD Meeting, FL, USA, March.
    • Rezzi S, Ginty F, Beaumont A, et al. 2009 Body composition precision with the Lunar iDXA. ISCD Meeting, FL, USA, March.
    • (2009)
    • Rezzi, S.1    Ginty, F.2    Beaumont, A.3
  • 14
    • 0033963011 scopus 로고    scopus 로고
    • Long term precision of DXA scanning assessed over seven years in forty postmenopausal women
    • Patel R., Blake G.M., Rymer J., et al. Long term precision of DXA scanning assessed over seven years in forty postmenopausal women. Osteoporos Int 2000, 11(1):68-75.
    • (2000) Osteoporos Int , vol.11 , Issue.1 , pp. 68-75
    • Patel, R.1    Blake, G.M.2    Rymer, J.3
  • 15
    • 38549089609 scopus 로고    scopus 로고
    • Factors affecting short term bone density precision assessment and the effect on patient monitoring
    • Leslie W.D. Factors affecting short term bone density precision assessment and the effect on patient monitoring. J Bone Mineral Res 2008, 23(2):199-204.
    • (2008) J Bone Mineral Res , vol.23 , Issue.2 , pp. 199-204
    • Leslie, W.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.