메뉴 건너뛰기




Volumn 23, Issue 4, 2008, Pages 457-462

How important are BMD accuracy errors for the clinical interpretation of DXA scans?

Author keywords

[No Author keywords available]

Indexed keywords

ADIPOSE TISSUE; BODY MASS; BONE; BONE DENSITOMETRY; CLINICAL EFFECTIVENESS; DIAGNOSTIC ACCURACY; ENERGY; HUMAN; MEDICAL ERROR; PHOTON; PHYSICIAN; REVIEW; SOFT TISSUE; X RAY;

EID: 41849114937     PISSN: 08840431     EISSN: None     Source Type: Journal    
DOI: 10.1359/jbmr.071119     Document Type: Review
Times cited : (53)

References (35)
  • 2
    • 34250030054 scopus 로고    scopus 로고
    • DXA in vivo BMD methodology: An erroneous and misleading research and clinical gauge of bone mineral status, bone fragility and bone remodelling
    • Bolotin HH 2007 DXA in vivo BMD methodology: An erroneous and misleading research and clinical gauge of bone mineral status, bone fragility and bone remodelling. Bone 41:138-154.
    • (2007) Bone , vol.41 , pp. 138-154
    • Bolotin, H.H.1
  • 4
    • 0029112340 scopus 로고
    • Accurate assessment of precision errors: How to measure the reproducibility of bone densitometry techniques
    • Gluer CC, Blake G, Lu Y, Blunt BA, Jergas M, Genant HK 1995 Accurate assessment of precision errors: How to measure the reproducibility of bone densitometry techniques. Osteoporos Int 5:262-270.
    • (1995) Osteoporos Int , vol.5 , pp. 262-270
    • Gluer, C.C.1    Blake, G.2    Lu, Y.3    Blunt, B.A.4    Jergas, M.5    Genant, H.K.6
  • 5
    • 0029056614 scopus 로고
    • Impact of soft tissue on in vivo accuracy of bone mineral measurements in the spine, hip and forearm: A human cadaver study
    • Svendsen OL, Hassager C, Skodt V, Christiansen C 1995 Impact of soft tissue on in vivo accuracy of bone mineral measurements in the spine, hip and forearm: A human cadaver study. J Bone Miner Res 10:868-873.
    • (1995) J Bone Miner Res , vol.10 , pp. 868-873
    • Svendsen, O.L.1    Hassager, C.2    Skodt, V.3    Christiansen, C.4
  • 6
    • 0030053035 scopus 로고    scopus 로고
    • Accuracy and the influence of marrow fat on quantitative CT and dual-energy X-ray absorptiometry measurements of the femoral neck in vitro
    • Kuiper JW, van Kuijk C, Grashuis JL, Ederveen AG, Schutte HE 1996 Accuracy and the influence of marrow fat on quantitative CT and dual-energy X-ray absorptiometry measurements of the femoral neck in vitro. Osteoporos Int 6:25-30.
    • (1996) Osteoporos Int , vol.6 , pp. 25-30
    • Kuiper, J.W.1    van Kuijk, C.2    Grashuis, J.L.3    Ederveen, A.G.4    Schutte, H.E.5
  • 7
    • 33749188208 scopus 로고    scopus 로고
    • Available online at, Accessed January 24, 2008
    • International Society for Clinical Densitometry 2005 Official positions. Available online at www.iscd.org/Visitors/positions/OfficialPositionsText.cfm. Accessed January 24, 2008..
    • (2005) Official positions
  • 9
    • 84965635988 scopus 로고
    • Vertebral bone mineral measurement using dual photon absorptiometry and computed tomography
    • Eriksson S, Isberg B, Lindgren U 1988 Vertebral bone mineral measurement using dual photon absorptiometry and computed tomography. Acta Radiol 29:89-94.
    • (1988) Acta Radiol , vol.29 , pp. 89-94
    • Eriksson, S.1    Isberg, B.2    Lindgren, U.3
  • 11
    • 0025358771 scopus 로고
    • Accuracy of dual-energy radiographic of the lumbar spine: A cadaver study
    • Ho CP, Kim RW, Schaffler MB, Sartoris DJ 1990 Accuracy of dual-energy radiographic of the lumbar spine: A cadaver study. Radiology 176:171-173.
    • (1990) Radiology , vol.176 , pp. 171-173
    • Ho, C.P.1    Kim, R.W.2    Schaffler, M.B.3    Sartoris, D.J.4
  • 12
  • 13
    • 0023347847 scopus 로고
    • The effect of fat on bone mineral measurements in normal subjects with recommended values of bone, muscle and fat attenuation coefficients
    • Webber CE 1987 The effect of fat on bone mineral measurements in normal subjects with recommended values of bone, muscle and fat attenuation coefficients. Clin Phys Physiol Meas 8:143-158.
    • (1987) Clin Phys Physiol Meas , vol.8 , pp. 143-158
    • Webber, C.E.1
  • 14
    • 0024618398 scopus 로고
    • The error due to fat inhomogeneity in lumbar spine bone mineral measurements
    • Farrell TJ, Webber CE 1989 The error due to fat inhomogeneity in lumbar spine bone mineral measurements. Clin Phys Physiol Meas 10:57-64.
    • (1989) Clin Phys Physiol Meas , vol.10 , pp. 57-64
    • Farrell, T.J.1    Webber, C.E.2
  • 15
    • 41849132738 scopus 로고    scopus 로고
    • Tothill P, Pye DW, Teper J 1989 The influence of extraskeletal fat on the accuracy of dual photon absorptiometry of the spine. In: Ring EFJ, Evans WD, Dixon AS, eds. Osteoporosis and Bone Mineral Measurement. ISPM, York, UK, pp. 48-53.
    • Tothill P, Pye DW, Teper J 1989 The influence of extraskeletal fat on the accuracy of dual photon absorptiometry of the spine. In: Ring EFJ, Evans WD, Dixon AS, eds. Osteoporosis and Bone Mineral Measurement. ISPM, York, UK, pp. 48-53.
  • 16
    • 0026657493 scopus 로고
    • Errors due to non-uniform distribution of fat in dual x-ray absorptiometry of the lumbar spine
    • Tothill P, Pye DW 1992 Errors due to non-uniform distribution of fat in dual x-ray absorptiometry of the lumbar spine. Br J Radiol 65:807-813.
    • (1992) Br J Radiol , vol.65 , pp. 807-813
    • Tothill, P.1    Pye, D.W.2
  • 17
    • 0031722820 scopus 로고    scopus 로고
    • A new perspective on the causal influence of soft tissue composition on DXA-measured in vivo bone mineral density
    • Bolotin HH 1998 A new perspective on the causal influence of soft tissue composition on DXA-measured in vivo bone mineral density. J Bone Miner Res 13:1739-1746.
    • (1998) J Bone Miner Res , vol.13 , pp. 1739-1746
    • Bolotin, H.H.1
  • 18
    • 0035141788 scopus 로고    scopus 로고
    • Inaccuracies inherent in patient-specific dual-energy x-ray absorptiometry bone mineral density measurements: Comprehensive phantom-based evaluation
    • Bolotin HH, Sievansen H, Grashuis JL, Kuiper JW, Jarvinen TL 2001 Inaccuracies inherent in patient-specific dual-energy x-ray absorptiometry bone mineral density measurements: Comprehensive phantom-based evaluation. J Bone Miner Res 16:417-426.
    • (2001) J Bone Miner Res , vol.16 , pp. 417-426
    • Bolotin, H.H.1    Sievansen, H.2    Grashuis, J.L.3    Kuiper, J.W.4    Jarvinen, T.L.5
  • 19
    • 0035055470 scopus 로고    scopus 로고
    • Inaccuracies inherent in dual-energy x-ray absorptiometry in vivo bone mineral density can seriously mislead diagnostic/prognostic interpretations of patient-specific bone fragility
    • Bolotin HH, Sievansen H 2001 Inaccuracies inherent in dual-energy x-ray absorptiometry in vivo bone mineral density can seriously mislead diagnostic/prognostic interpretations of patient-specific bone fragility. J Bone Miner Res 16:799-805.
    • (2001) J Bone Miner Res , vol.16 , pp. 799-805
    • Bolotin, H.H.1    Sievansen, H.2
  • 20
    • 0035050099 scopus 로고    scopus 로고
    • Inaccuracies inherent in dual-energy x-ray absorptiometry in vivo bone mineral densitometry may flaw osteopenic/osteoporotic interpretations and mislead assessment of antresorptive therapy effectiveness
    • Bolotin HH 2001 Inaccuracies inherent in dual-energy x-ray absorptiometry in vivo bone mineral densitometry may flaw osteopenic/osteoporotic interpretations and mislead assessment of antresorptive therapy effectiveness. Bone 28:548-555.
    • (2001) Bone , vol.28 , pp. 548-555
    • Bolotin, H.H.1
  • 21
    • 0142091194 scopus 로고    scopus 로고
    • Patient-specific DXA bone mineral density inaccuracies: Quantitative effect of nonuniform extraosseous fat distributions
    • Bolotin HH, Sievansen H, Grashuis JL 2003 Patient-specific DXA bone mineral density inaccuracies: Quantitative effect of nonuniform extraosseous fat distributions. J Bone Miner Res 18:1020-1027.
    • (2003) J Bone Miner Res , vol.18 , pp. 1020-1027
    • Bolotin, H.H.1    Sievansen, H.2    Grashuis, J.L.3
  • 22
    • 0014290743 scopus 로고
    • Precision and accuracy of bone mineral determination by direct photon absorptiometry
    • Cameron JR, Mazess RB, Sorenson JA 1968 Precision and accuracy of bone mineral determination by direct photon absorptiometry. Invest Radiol 3:141-150.
    • (1968) Invest Radiol , vol.3 , pp. 141-150
    • Cameron, J.R.1    Mazess, R.B.2    Sorenson, J.A.3
  • 23
    • 0030749165 scopus 로고    scopus 로고
    • Technical principles of dual energy x-ray absorptiometry
    • Blake GM, Fogelman I 1997 Technical principles of dual energy x-ray absorptiometry. Semin Nucl Med 27:210-228.
    • (1997) Semin Nucl Med , vol.27 , pp. 210-228
    • Blake, G.M.1    Fogelman, I.2
  • 25
    • 41849089127 scopus 로고    scopus 로고
    • Correcting DXA pediatric bone mineral density measurements to account for fat inhomogeneity
    • Lee DC, Wren TAL, Gilanz V 2007 Correcting DXA pediatric bone mineral density measurements to account for fat inhomogeneity. J Bone Miner Res 22:S1;S494-S495.
    • (2007) J Bone Miner Res , vol.22 , Issue.S1
    • Lee, D.C.1    Wren, T.A.L.2    Gilanz, V.3
  • 26
    • 33846658719 scopus 로고    scopus 로고
    • Vertebral marrow fat content and diffusion and perfusion indexes in women with varying bone density: MR evaluation
    • Griffith JF, Yeung DKW, Antonio GE, Wong SYS, Kwok TCK, Woo J, Leung PC 2006 Vertebral marrow fat content and diffusion and perfusion indexes in women with varying bone density: MR evaluation. Radiology 241:831-838.
    • (2006) Radiology , vol.241 , pp. 831-838
    • Griffith, J.F.1    Yeung, D.K.W.2    Antonio, G.E.3    Wong, S.Y.S.4    Kwok, T.C.K.5    Woo, J.6    Leung, P.C.7
  • 29
    • 0026215143 scopus 로고
    • The impact of measurement errors on the diagnostic value of bone mass measurements: Theoretical considerations
    • Hassager C, Jensen SB, Gotfredsen A, Christiansen C 1991 The impact of measurement errors on the diagnostic value of bone mass measurements: Theoretical considerations. Osteoporos Int 1:250-256.
    • (1991) Osteoporos Int , vol.1 , pp. 250-256
    • Hassager, C.1    Jensen, S.B.2    Gotfredsen, A.3    Christiansen, C.4
  • 30
    • 0033963011 scopus 로고    scopus 로고
    • Long-term precision of DXA scanning assessed over seven years in forty postmenopausal women
    • Patel R, Blake GM, Rymer J, Fogelman I 2000 Long-term precision of DXA scanning assessed over seven years in forty postmenopausal women. Osteoporos Int 11:68-75.
    • (2000) Osteoporos Int , vol.11 , pp. 68-75
    • Patel, R.1    Blake, G.M.2    Rymer, J.3    Fogelman, I.4
  • 31
    • 0029986509 scopus 로고    scopus 로고
    • Meta-analysis of how well measures of bone mineral density predict occurrence of osteoporotic fractures
    • Marshall D, Johnell O, Wedel H 1996 Meta-analysis of how well measures of bone mineral density predict occurrence of osteoporotic fractures. BMJ 312:1254-1259.
    • (1996) BMJ , vol.312 , pp. 1254-1259
    • Marshall, D.1    Johnell, O.2    Wedel, H.3
  • 33
    • 0034960122 scopus 로고    scopus 로고
    • Peripheral or central densitometry: Does it matter which technique we use?
    • Blake GM, Fogelman I 2001 Peripheral or central densitometry: Does it matter which technique we use? J Clin Densitom 4:83-96.
    • (2001) J Clin Densitom , vol.4 , pp. 83-96
    • Blake, G.M.1    Fogelman, I.2
  • 34
    • 33846669092 scopus 로고    scopus 로고
    • The role of DXA scanning in the diagnosis and treatment of osteoporosis
    • Blake GM, Fogelman I 2007 The role of DXA scanning in the diagnosis and treatment of osteoporosis. J Clin Densitom 10:102-110.
    • (2007) J Clin Densitom , vol.10 , pp. 102-110
    • Blake, G.M.1    Fogelman, I.2
  • 35
    • 0031201603 scopus 로고    scopus 로고
    • Standardization of femur BMD
    • Hanson J 1997 Standardization of femur BMD. J Bone Miner Res 12:1316-1317.
    • (1997) J Bone Miner Res , vol.12 , pp. 1316-1317
    • Hanson, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.