메뉴 건너뛰기




Volumn 10, Issue 1, 2015, Pages

Accuracy of inverse treatment planning on substitute CT images derived from MR data for brain lesions

Author keywords

MRI; Radiotherapy; s CT; Substitute CT; Treatment planning

Indexed keywords

ACCURACY; ARTICLE; BRAIN RADIOGRAPHY; CLINICAL ARTICLE; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; DOSE CALCULATION; DOSIMETRY; FEASIBILITY STUDY; HUMAN; IMAGE RECONSTRUCTION; NUCLEAR MAGNETIC RESONANCE IMAGING; ORGANS AT RISK; PATIENT POSITIONING; PILOT STUDY; RISK ASSESSMENT; THREE DIMENSIONAL IMAGING; TREATMENT PLANNING; BRAIN NEOPLASMS; GLIOBLASTOMA; IMAGE PROCESSING; INTENSITY MODULATED RADIATION THERAPY; PROCEDURES; RADIOTHERAPY DOSAGE; RADIOTHERAPY PLANNING SYSTEM; X-RAY COMPUTED TOMOGRAPHY;

EID: 84939801969     PISSN: None     EISSN: 1748717X     Source Type: Journal    
DOI: 10.1186/s13014-014-0308-1     Document Type: Article
Times cited : (31)

References (23)
  • 1
    • 0032720642 scopus 로고    scopus 로고
    • The contribution of magnetic resonance imaging to the three-dimensional treatment planning of localized prostate cancer
    • Debois M, Oyen R, Maes F, Verswijvel G, Gatti G, Bosmans H, et al. The contribution of magnetic resonance imaging to the three-dimensional treatment planning of localized prostate cancer. Int J Radiat Oncol Biol Phys. 1999;45:857-65.
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 857-865
    • Debois, M.1    Oyen, R.2    Maes, F.3    Verswijvel, G.4    Gatti, G.5    Bosmans, H.6
  • 2
    • 42349087868 scopus 로고    scopus 로고
    • Implications of contrast-enhanced CT-based and MRI-based target volume delineations in radiotherapy treatment planning for brain tumors
    • Datta NR, David R, Gupta RK, Lal P. Implications of contrast-enhanced CT-based and MRI-based target volume delineations in radiotherapy treatment planning for brain tumors. J Cancer Res Ther. 2008;4:9-13.
    • (2008) J Cancer Res Ther , vol.4 , pp. 9-13
    • Datta, N.R.1    David, R.2    Gupta, R.K.3    Lal, P.4
  • 3
    • 0030657496 scopus 로고    scopus 로고
    • The potential impact of CT-MRI matching on tumor volume delineation in advanced head and neck cancer
    • Rasch C, Keus R, Pameijer FA, Koops W, De Ru V, Muller S, et al. The potential impact of CT-MRI matching on tumor volume delineation in advanced head and neck cancer. Int J Radiat Oncol Biol Phys. 1997;39:841-8.
    • (1997) Int J Radiat Oncol Biol Phys , vol.39 , pp. 841-848
    • Rasch, C.1    Keus, R.2    Pameijer, F.A.3    Koops, W.4    Ru, V.5    Muller, S.6
  • 4
    • 80051789536 scopus 로고    scopus 로고
    • Clinical outcome of protocol based image (MRI) guided adaptive brachytherapy combined with 3D conformal radiotherapy with or without chemotherapy in patients with locally advanced cervical cancer
    • Pötter R, Georg P, Dimopoulos JCA, Grimm M, Berger D, Nesvacil N, et al. Clinical outcome of protocol based image (MRI) guided adaptive brachytherapy combined with 3D conformal radiotherapy with or without chemotherapy in patients with locally advanced cervical cancer. Radiother Oncol. 2011;100:116-23.
    • (2011) Radiother Oncol , vol.100 , pp. 116-123
    • Pötter, R.1    Georg, P.2    Dimopoulos, J.C.A.3    Grimm, M.4    Berger, D.5    Nesvacil, N.6
  • 5
    • 71049137342 scopus 로고    scopus 로고
    • Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments
    • Nyholm T, Nyberg M, Karlsson MG, Karlsson M. Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments. Radiat Oncol. 2009;4:54.
    • (2009) Radiat Oncol , vol.4 , pp. 54
    • Nyholm, T.1    Nyberg, M.2    Karlsson, M.G.3    Karlsson, M.4
  • 7
    • 33746661222 scopus 로고    scopus 로고
    • 3T MR-based treatment planning for radiotherapy of brain lesions
    • Stanescu T, Hans-sonke J, Stavrev P, Fallone BG. 3T MR-based treatment planning for radiotherapy of brain lesions. Radiol Oncol. 2006;40:125-32.
    • (2006) Radiol Oncol , vol.40 , pp. 125-132
    • Stanescu, T.1    Hans-sonke, J.2    Stavrev, P.3    Fallone, B.G.4
  • 10
    • 4544319864 scopus 로고    scopus 로고
    • MRI-based treatment planning for radiotherapy: dosimetric verification for prostate IMRT
    • Chen L, Price RA, Wang L, Li J, Qin L, McNeeley S, et al. MRI-based treatment planning for radiotherapy: dosimetric verification for prostate IMRT. Int J Radiat Oncol Biol Phys. 2004;60:636-47.
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 636-647
    • Chen, L.1    Price, R.A.2    Wang, L.3    Li, J.4    Qin, L.5    McNeeley, S.6
  • 11
    • 84872042898 scopus 로고    scopus 로고
    • T1/T2*-weighted MRI provides clinically relevant pseudo-CT density data for the pelvic bones in MRI-only based radiotherapy treatment planning
    • Kapanen M, Tenhunen M. T1/T2*-weighted MRI provides clinically relevant pseudo-CT density data for the pelvic bones in MRI-only based radiotherapy treatment planning. Acta Oncologica. 2013;52:612-8.
    • (2013) Acta Oncologica , vol.52 , pp. 612-618
    • Kapanen, M.1    Tenhunen, M.2
  • 12
    • 84859849568 scopus 로고    scopus 로고
    • An atlas-based electron density mapping method for Magnetic Resonance Imaging (MRI)-alone treatment planning and adaptive MRI-based prostate radiation therapy
    • Dowling JA, Lambert J, Parker J, Salvado O, Fripp J, Capp A, et al. An atlas-based electron density mapping method for Magnetic Resonance Imaging (MRI)-alone treatment planning and adaptive MRI-based prostate radiation therapy. Int J Radiat Oncol Biol Phys. 2012;83(1):e5-11.
    • (2012) Int J Radiat Oncol Biol Phys , vol.83 , Issue.1 , pp. e5-11
    • Dowling, J.A.1    Lambert, J.2    Parker, J.3    Salvado, O.4    Fripp, J.5    Capp, A.6    Wratten, C.7    Denham, J.W.8    Greer, P.B.9
  • 13
    • 77954077099 scopus 로고    scopus 로고
    • Treatment planning using MRI data: an analysis of the dose calculation accuracy for different treatment regions
    • Jonsson JH, Karlsson MG, Karlsson M, Nyholm T. Treatment planning using MRI data: an analysis of the dose calculation accuracy for different treatment regions. Radiat Oncol. 2010;5:62.
    • (2010) Radiat Oncol , vol.5 , pp. 62
    • Jonsson, J.H.1    Karlsson, M.G.2    Karlsson, M.3    Nyholm, T.4
  • 14
    • 79952454508 scopus 로고    scopus 로고
    • MRI-guided prostate radiation therapy planning: Investigation of dosimetric accuracy of MRI-based dose planning
    • Lambert J, Greer PB, Menk F, Patterson J, Parker J, Dahl K, et al. MRI-guided prostate radiation therapy planning: Investigation of dosimetric accuracy of MRI-based dose planning. Radiother Oncol. 2011;98:330-4.
    • (2011) Radiother Oncol , vol.98 , pp. 330-334
    • Lambert, J.1    Greer, P.B.2    Menk, F.3    Patterson, J.4    Parker, J.5    Dahl, K.6
  • 15
    • 77957038794 scopus 로고    scopus 로고
    • Toward implementing an MRI-Based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype
    • Catana C, Van der Kouwe A, Benner T, Michel CJ, Hamm M, Fenchel M, et al. Toward implementing an MRI-Based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype. J Nucl Med. 2010;51:1431-8.
    • (2010) J Nucl Med , vol.51 , pp. 1431-1438
    • Catana, C.1    Van der Kouwe, A.2    Benner, T.3    Michel, C.J.4    Hamm, M.5    Fenchel, M.6
  • 16
    • 79959534469 scopus 로고    scopus 로고
    • CT substitute derived from MRI sequences with ultrashort echo time
    • Johansson A, Karlsson M, Nyholm T. CT substitute derived from MRI sequences with ultrashort echo time. Med Phys. 2011;38:2708.
    • (2011) Med Phys , vol.38 , pp. 2708
    • Johansson, A.1    Karlsson, M.2    Nyholm, T.3
  • 17
    • 84863527875 scopus 로고    scopus 로고
    • Voxel-wise uncertainty in CT substitute derived from MRI
    • Johansson A, Karlsson M, Yu J, Asklund T, Nyholm T. Voxel-wise uncertainty in CT substitute derived from MRI. Med Phys. 2012;39:3283-90.
    • (2012) Med Phys , vol.39 , pp. 3283-3290
    • Johansson, A.1    Karlsson, M.2    Yu, J.3    Asklund, T.4    Nyholm, T.5
  • 20
    • 4644278739 scopus 로고    scopus 로고
    • Use of spherical harmonic deconvolution methods to compensate for nonlinear gradient effects on MRI images
    • Janke A, Zhao H, Cowin GJ, Galloway GJ, Doddrell DM. Use of spherical harmonic deconvolution methods to compensate for nonlinear gradient effects on MRI images. Magn Reson Med. 2004;52:115-22.
    • (2004) Magn Reson Med , vol.52 , pp. 115-122
    • Janke, A.1    Zhao, H.2    Cowin, G.J.3    Galloway, G.J.4    Doddrell, D.M.5
  • 21
    • 33745097528 scopus 로고    scopus 로고
    • Accuracy of device-specific 2D and 3D image distortion correction algorithms for magnetic resonance imaging of the head provided by a manufacturer
    • Karger CP, Höss A, Bendl R, Canda V, Schad L. Accuracy of device-specific 2D and 3D image distortion correction algorithms for magnetic resonance imaging of the head provided by a manufacturer. Phys Med Biol. 2006;51:N253-61.
    • (2006) Phys Med Biol , vol.51 , pp. N253-N261
    • Karger, C.P.1    Höss, A.2    Bendl, R.3    Canda, V.4    Schad, L.5
  • 22
    • 28744453924 scopus 로고    scopus 로고
    • Segmentation of skull and scalp in 3-D human MRI using mathematical morphology
    • Dogdas B, Shattuck DW, Leahy RM. Segmentation of skull and scalp in 3-D human MRI using mathematical morphology. Hum Brain Mapp. 2005;26:273-85.
    • (2005) Hum Brain Mapp , vol.26 , pp. 273-285
    • Dogdas, B.1    Shattuck, D.W.2    Leahy, R.M.3
  • 23
    • 84858663070 scopus 로고    scopus 로고
    • Attenuation Correction in MR-BrainPET with Segmented Tl-weighted MR images of the Patient ' s Head - A Comparative Study with CT
    • Wagenknecht G, Kops ER, Mantlik F, Fried E, Pilz T, Hautzel H, Tellmann L, Pichler BJ, Herzog H. Attenuation Correction in MR-BrainPET with Segmented Tl-weighted MR images of the Patient ' s Head - A Comparative Study with CT. 2011:2261-2266.
    • (2011) , pp. 2261-2266
    • Wagenknecht, G.1    Kops, E.R.2    Mantlik, F.3    Fried, E.4    Pilz, T.5    Hautzel, H.6    Tellmann, L.7    Pichler, B.J.8    Herzog, H.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.