메뉴 건너뛰기




Volumn 26, Issue 1, 2013, Pages 127-136

Evaluation of an attenuation correction method for PET/MR imaging of the head based on substitute CT images

Author keywords

18F FLT; Attenuation correction; PET MR; Substitute CT; UTE

Indexed keywords

DIAGNOSTIC AGENT; FLUORODEOXYGLUCOSE F 18; RADIOPHARMACEUTICAL AGENT;

EID: 84874117797     PISSN: 09685243     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10334-012-0339-2     Document Type: Article
Times cited : (40)

References (23)
  • 2
    • 84865325053 scopus 로고    scopus 로고
    • Combined PET/MR systems: An overview and comparison of currently available options
    • 22695336 1:STN:280:DC%2BC38jhsV2rsA%3D%3D
    • Herzog H, Van Den Hoff J (2012) Combined PET/MR systems: an overview and comparison of currently available options. Q J Nucl Med Mol Imaging 56(3):247-267
    • (2012) Q J Nucl Med Mol Imaging , vol.56 , Issue.3 , pp. 247-267
    • Herzog, H.1    Van Den Hoff, J.2
  • 3
    • 0031791001 scopus 로고    scopus 로고
    • Attenuation correction for a combined 3D PET/CT scanner
    • 9800714 10.1118/1.598392 1:STN:280:DyaK1M%2FhslSqtA%3D%3D
    • Kinahan PE, Townsend DW, Beyer T, Sashin D (1998) Attenuation correction for a combined 3D PET/CT scanner. Med Phys 25:2046-2053
    • (1998) Med Phys , vol.25 , pp. 2046-2053
    • Kinahan, P.E.1    Townsend, D.W.2    Beyer, T.3    Sashin, D.4
  • 4
    • 60549086399 scopus 로고    scopus 로고
    • Towards quantitative PET/MRI: A review of MR-based attenuation correction techniques
    • 19104810 10.1007/s00259-008-1007-7
    • Hofmann M, Pichler B, Schölkopf B, Beyer T (2009) Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques. Eur J Nucl Med Mol Imaging 36(Suppl 1):S93-S104
    • (2009) Eur J Nucl Med Mol Imaging , vol.36 , Issue.SUPPL. 1
    • Hofmann, M.1    Pichler, B.2    Schölkopf, B.3    Beyer, T.4
  • 5
    • 77952302436 scopus 로고    scopus 로고
    • MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences
    • 20439508 10.2967/jnumed.109.065425
    • Keereman V, Fierens Y, Broux T, De Deene Y, Lonneux M, Vandenberghe S (2010) MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences. J Nucl Med 51:812-818
    • (2010) J Nucl Med , vol.51 , pp. 812-818
    • Keereman, V.1    Fierens, Y.2    Broux, T.3    De Deene, Y.4    Lonneux, M.5    Vandenberghe, S.6
  • 6
    • 79952162564 scopus 로고    scopus 로고
    • Simultaneous reconstruction of activity and attenuation for PET/MR
    • 21118768 10.1109/TMI.2010.2095464
    • Salomon A, Goedicke A, Schweizer B, Aach T, Schulz V (2011) Simultaneous reconstruction of activity and attenuation for PET/MR. IEEE Trans Med Imaging 30(3):804-813
    • (2011) IEEE Trans Med Imaging , vol.30 , Issue.3 , pp. 804-813
    • Salomon, A.1    Goedicke, A.2    Schweizer, B.3    Aach, T.4    Schulz, V.5
  • 9
    • 77957038794 scopus 로고    scopus 로고
    • Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype
    • 20810759 10.2967/jnumed.109.069112 1:CAS:528:DC%2BC3cXht1ejsLvI
    • Catana C, van der Kouwe A, Benner T, Michel CJ, Hamm M, Fenchel M, Fischl B, Rosen B, Schmand M, Sorensen AG (2010) Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype. J Nucl Med 51:1431-1438
    • (2010) J Nucl Med , vol.51 , pp. 1431-1438
    • Catana, C.1    Van Der Kouwe, A.2    Benner, T.3    Michel, C.J.4    Hamm, M.5    Fenchel, M.6    Fischl, B.7    Rosen, B.8    Schmand, M.9    Sorensen, A.G.10
  • 10
    • 80052644918 scopus 로고    scopus 로고
    • MRI-based attenuation correction for whole-body PET/MRI: Quantitative evaluation of segmentation- and atlas-based methods
    • 21828115 10.2967/jnumed.110.078949
    • Hofmann M, Bezrukov I, Mantlik F, Aschoff P, Steinke F, Beyer T, Pichler BJ, Schölkopf B (2011) MRI-based attenuation correction for whole-body PET/MRI: quantitative evaluation of segmentation- and atlas-based methods. J Nucl Med 52(9):1392-1399
    • (2011) J Nucl Med , vol.52 , Issue.9 , pp. 1392-1399
    • Hofmann, M.1    Bezrukov, I.2    Mantlik, F.3    Aschoff, P.4    Steinke, F.5    Beyer, T.6    Pichler, B.J.7    Schölkopf, B.8
  • 11
    • 79960336732 scopus 로고    scopus 로고
    • Attenuation correction methods suitable for brain imaging with a PET/MRI scanner: A comparison of tissue atlas and template attenuation map approaches
    • 21724984 10.2967/jnumed.110.085076
    • Malone IB, Ansorge RE, Williams GB, Nestor PJ, Carpenter TA, Fryer TD (2011) Attenuation correction methods suitable for brain imaging with a PET/MRI scanner: a comparison of tissue atlas and template attenuation map approaches. J Nucl Med 52(7):1142-1149
    • (2011) J Nucl Med , vol.52 , Issue.7 , pp. 1142-1149
    • Malone, I.B.1    Ansorge, R.E.2    Williams, G.B.3    Nestor, P.J.4    Carpenter, T.A.5    Fryer, T.D.6
  • 14
    • 0242499346 scopus 로고    scopus 로고
    • Magnetic resonance: An introduction to ultrashort TE (UTE) imaging
    • 14600447 10.1097/00004728-200311000-00001
    • Robson M, Gatehouse P, Bydder M, Bydder G (2003) Magnetic resonance: an introduction to ultrashort TE (UTE) imaging. J Comput Assist Tomogr 27:825-846
    • (2003) J Comput Assist Tomogr , vol.27 , pp. 825-846
    • Robson, M.1    Gatehouse, P.2    Bydder, M.3    Bydder, G.4
  • 15
    • 79959534469 scopus 로고    scopus 로고
    • CT substitute derived from MRI sequences with ultrashort echo time
    • 21776807 10.1118/1.3578928
    • Johansson A, Karlsson M, Nyholm T (2011) CT substitute derived from MRI sequences with ultrashort echo time. Med Phys 38(5):2708-2714
    • (2011) Med Phys , vol.38 , Issue.5 , pp. 2708-2714
    • Johansson, A.1    Karlsson, M.2    Nyholm, T.3
  • 16
    • 84863527875 scopus 로고    scopus 로고
    • Voxel-wise uncertainty in CT substitute derived from MRI
    • 22755711 10.1118/1.4711807
    • Johansson A, Karlsson M, Yu J, Asklund T, Nyholm T (2012) Voxel-wise uncertainty in CT substitute derived from MRI. Med Phys 39(6):3283-3290
    • (2012) Med Phys , vol.39 , Issue.6 , pp. 3283-3290
    • Johansson, A.1    Karlsson, M.2    Yu, J.3    Asklund, T.4    Nyholm, T.5
  • 17
    • 20044366163 scopus 로고    scopus 로고
    • Radiotherapy plus concomitant and adjuvant temozolomide for glioblastoma
    • 15758009 10.1056/NEJMoa043330 1:CAS:528:DC%2BD2MXit1Wksbk%3D
    • Stupp R, Mason WP, van den Bent MJ, Weller M, Fisher B, Taphoorn MJ, Belanger K, et al. (2005) Radiotherapy plus concomitant and adjuvant temozolomide for glioblastoma. N Engl J Med 352(10):987-996
    • (2005) N Engl J Med , vol.352 , Issue.10 , pp. 987-996
    • Stupp, R.1    Mason, W.P.2    Van Den Bent, M.J.3    Weller, M.4    Fisher, B.5    Taphoorn, M.J.6    Belanger, K.7
  • 20
    • 17144430524 scopus 로고    scopus 로고
    • A complete distortion correction for MR images: I. Gradient warp correction
    • 15798328 10.1088/0031-9155/50/7/001
    • Doran S, Charles-Edwards L, Reinsberg S, Leach M (2005) A complete distortion correction for MR images: I. Gradient warp correction. Phys Med Biol 50:1343-1361
    • (2005) Phys Med Biol , vol.50 , pp. 1343-1361
    • Doran, S.1    Charles-Edwards, L.2    Reinsberg, S.3    Leach, M.4
  • 22
    • 0036093165 scopus 로고    scopus 로고
    • PET attenuation coefficients from CT images: Experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients
    • 12111133 10.1007/s00259-002-0796-3 1:STN:280:DC%2BD38zms1Gjtg%3D%3D
    • Burger C, Goerres G, Schoenes S, Buck A, Lonn AH, Von Schulthess GK (2002) PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients. Eur J Nucl Med Mol Imaging 29:922-927
    • (2002) Eur J Nucl Med Mol Imaging , vol.29 , pp. 922-927
    • Burger, C.1    Goerres, G.2    Schoenes, S.3    Buck, A.4    Lonn, A.H.5    Von Schulthess, G.K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.