메뉴 건너뛰기




Volumn , Issue , 2015, Pages 76-81

An ELISA-based amperometric biosensor within a photo-patternable adhesive microfluidic channel

Author keywords

amperometric biosensor; convective redox cycling; microfluidics; photo patternable adhesive

Indexed keywords

ADHESIVES; CHEMICAL SENSORS; ENZYME ELECTRODES; FLUIDIC DEVICES; LAMINAR FLOW; MICROELECTRODES;

EID: 84939506471     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NEMS.2015.7147377     Document Type: Conference Paper
Times cited : (2)

References (21)
  • 1
    • 84155170753 scopus 로고    scopus 로고
    • Electrochemical immunosensing on board microfluidic chip platforms
    • M. Hervas, M. A. Lopez, A. Escarpa, "Electrochemical immunosensing on board microfluidic chip platforms", Trends Anal. Chem., vol. 31, pp. 109-128, 2012.
    • (2012) Trends Anal. Chem. , vol.31 , pp. 109-128
    • Hervas, M.1    Lopez, M.A.2    Escarpa, A.3
  • 2
    • 33847712643 scopus 로고    scopus 로고
    • Mesoscopic concentration fluctuations in a fluidic nanocavity detected by redox cycling
    • M. A. G. Zevenbergen, D. Krapf, M. Zuiddam, S. G. Lemay, "Mesoscopic concentration fluctuations in a fluidic nanocavity detected by redox cycling, " Nano Lett., vol. 7, pp. 384-388, 2007.
    • (2007) Nano Lett. , vol.7 , pp. 384-388
    • Zevenbergen, M.A.G.1    Krapf, D.2    Zuiddam, M.3    Lemay, S.G.4
  • 3
    • 0027615898 scopus 로고
    • Small-volume voltammetric detection of 4-aminophenol with interdigitated array electrodes and its application to electrochemical enzyme immunoassay
    • O. Niwa, Y. Xu, H.B. Halsall, W.R. Heineman, "Small-volume voltammetric detection of 4-aminophenol with interdigitated array electrodes and its application to electrochemical enzyme immunoassay, " Anal. Chem., vol. 65, pp.1559-63, 1993.
    • (1993) Anal. Chem. , vol.65 , pp. 1559-1563
    • Niwa, O.1    Xu, Y.2    Halsall, H.B.3    Heineman, W.R.4
  • 4
    • 0022787477 scopus 로고
    • Digital simulation of the measured electrochemical response of reversible redox couples at microelectrode arrays: Consequences arising from closely spaced ultramicroelectrodes
    • A. J. Bard, J. A. Crayston, G. P. Kittlesen, T. V. Shea, M. S. Wrighton, "Digital Simulation of the Measured Electrochemical Response of Reversible Redox Couples at Microelectrode Arrays: Consequences Arising from Closely Spaced Ultramicroelectrodes, " Anal. Chem., vol. 58, pp.2321-2331, 1986.
    • (1986) Anal. Chem. , vol.58 , pp. 2321-2331
    • Bard, A.J.1    Crayston, J.A.2    Kittlesen, G.P.3    Shea, T.V.4    Wrighton, M.S.5
  • 6
    • 84868130517 scopus 로고    scopus 로고
    • Elaboration of screenprinted microelectrodes working as generator/collector and their use in a flow cell system
    • A. René, C. Cugnet, D. Hauchard, and L. Authier, "Elaboration of screenprinted microelectrodes working as generator/collector and their use in a flow cell system, " Sensor. Actuat. B-Chem., vol. 174, pp. 225-230, 2012.
    • (2012) Sensor. Actuat. B-Chem. , vol.174 , pp. 225-230
    • René, A.1    Cugnet, C.2    Hauchard, D.3    Authier, L.4
  • 7
    • 77949811258 scopus 로고    scopus 로고
    • Theory and experiments of transport at channel microband electrodes under laminar flow. 3. Electrochemical detection at electrode arrays under steady state
    • C. Amatore, N. Da Mota, C. Sella, and L. Thouin, "Theory and experiments of transport at channel microband electrodes under laminar flow. 3. Electrochemical detection at electrode arrays under steady state, " Anal. Chem., vol. 82, no. 19, pp. 2434-2440, 2010.
    • (2010) Anal. Chem. , vol.82 , Issue.19 , pp. 2434-2440
    • Amatore, C.1    Da Mota, N.2    Sella, C.3    Thouin, L.4
  • 8
    • 84907894189 scopus 로고    scopus 로고
    • High-efficiency generation-collection microelectrochemical platform for interrogating electroactive thin films
    • M. J. Anderson and R. M. Crooks, "High-efficiency generation-collection microelectrochemical platform for interrogating electroactive thin films, " Anal. Chem., vol. 86, pp. 9962-9969, 2014.
    • (2014) Anal. Chem. , vol.86 , pp. 9962-9969
    • Anderson, M.J.1    Crooks, R.M.2
  • 9
    • 84893015094 scopus 로고    scopus 로고
    • Droplet array on local redox cycling-based electrochemical (LRC-EC) chip device
    • K. Ino, T. Goto, Y. Kanno, K.Y. Inoue, Y. Takahashi, H. Shiku, T. Matsue, "Droplet array on local redox cycling-based electrochemical (LRC-EC) chip device, " Lab Chip, vol. 14, pp. 787-794, 2014.
    • (2014) Lab Chip , vol.14 , pp. 787-794
    • Ino, K.1    Goto, T.2    Kanno, Y.3    Inoue, K.Y.4    Takahashi, Y.5    Shiku, H.6    Matsue, T.7
  • 13
    • 84938600137 scopus 로고    scopus 로고
    • Effects of counter electrode induced redox cycling on fe (III) reduction within microfluidic electrochemical cells
    • Y. Li, W. Van Roy, L. Lagae, P. M. Vereecken, "Effects of Counter Electrode Induced Redox Cycling on Fe (III) Reduction within Microfluidic Electrochemical Cells, " J. Electrochem. Soc., vol.161, pp.E128-E134, 2014.
    • (2014) J. Electrochem. Soc. , vol.161 , pp. E128-E134
    • Li, Y.1    Van Roy, W.2    Lagae, L.3    Vereecken, P.M.4
  • 14
    • 84858955358 scopus 로고    scopus 로고
    • Realization of a salt bridge-free microfluidic reference electrode
    • E. V. Dydek, M. V. Petersen, D. G. Nocera, K. F. Jensen, Realization of a salt bridge-free microfluidic reference electrode, Lab Chip, vol.12, pp.1431-1433, 2012.
    • (2012) Lab Chip , vol.12 , pp. 1431-1433
    • Dydek, E.V.1    Petersen, M.V.2    Nocera, D.G.3    Jensen, K.F.4
  • 15
    • 0347541068 scopus 로고    scopus 로고
    • Conductive copolymer-modified carbon fibre microelectrodes: Electrode characterization and electrochemical detection of p-aminophenol
    • M. Jamal, A. S. Sarac, E. Magner, "Conductive copolymer-modified carbon fibre microelectrodes: electrode characterization and electrochemical detection of p-aminophenol, " Sensor. Actuat. B-Chem., vol.97, pp.59-66, 2004.
    • (2004) Sensor. Actuat. B-Chem. , vol.97 , pp. 59-66
    • Jamal, M.1    Sarac, A.S.2    Magner, E.3
  • 18
    • 41849151140 scopus 로고    scopus 로고
    • Making it stick: Convection, reaction and diffusion in surface-based biosensors
    • T. M. Squires, R. J. Messinger, S. R. Manalis, "Making it stick: convection, reaction and diffusion in surface-based biosensors", Nat. Biotechnol., vol.26, pp.417-26, 2008.
    • (2008) Nat. Biotechnol. , vol.26 , pp. 417-426
    • Squires, T.M.1    Messinger, R.J.2    Manalis, S.R.3
  • 19
    • 80755143158 scopus 로고    scopus 로고
    • Electrochemical chip integrating scalable ring-ring electrode array to detect secreted alkaline phosphatase
    • M. Takeda, H. Shiku, K. Ino, and T. Matsue, "Electrochemical chip integrating scalable ring-ring electrode array to detect secreted alkaline phosphatase, " Analyst, vol. 136, pp. 4991-4996, 2011.
    • (2011) Analyst , vol.136 , pp. 4991-4996
    • Takeda, M.1    Shiku, H.2    Ino, K.3    Matsue, T.4
  • 21
    • 84898069578 scopus 로고    scopus 로고
    • Microfluidics biosensor chip with integrated screen-printed electrodes for amperometric detection of nerve agent
    • Y. J. Yoon, K. H. H. Li, Y. Z. Low, J. Yoon, and S. H. Ng, "Microfluidics biosensor chip with integrated screen-printed electrodes for amperometric detection of nerve agent, " Sensors Actuators, B Chem., vol. 198, pp. 233-238, 2014.
    • (2014) Sensors Actuators, B Chem. , vol.198 , pp. 233-238
    • Yoon, Y.J.1    Li, K.H.H.2    Low, Y.Z.3    Yoon, J.4    Ng, S.H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.