메뉴 건너뛰기




Volumn 188, Issue , 2013, Pages 212-220

Ultrasensitive amperometric magnetoimmunosensor for human C-reactive protein quantification in serum

Author keywords

Amperometric magnetoimmunosensors; CRP; Human serum; Magnetic beads

Indexed keywords

AMPEROMETRIC; COVALENT IMMOBILIZATION; CRP; ELECTRON TRANSFER MEDIATORS; HUMAN SERUM; INTERNATIONAL STANDARDS; MAGNETIC BEADS; SCREEN PRINTED ELECTRODES;

EID: 84881303486     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2013.07.026     Document Type: Article
Times cited : (64)

References (47)
  • 3
    • 0031298485 scopus 로고    scopus 로고
    • Reestablishment of homeostasis and the acute-phase proteins
    • G. Poznanovic, M. Petrovic, and Z. Magic Reestablishment of homeostasis and the acute-phase proteins Panminerva Medica 39 1997 291 298
    • (1997) Panminerva Medica , vol.39 , pp. 291-298
    • Poznanovic, G.1    Petrovic, M.2    Magic, Z.3
  • 4
    • 36448937142 scopus 로고    scopus 로고
    • Evaluating the role of biomarkers for cardiovascular risk prediction: Focus on CRP, BNP and urinary microalbumin
    • DOI 10.1586/14737159.7.6.793
    • A. May, and T.J. Wang Evaluating the role of biomarkers for cardiovascular risk prediction: focus on CRP, BNP and urinary microalbumin Expert Review of Molecular Diagnostics 7 2007 793 804 (Pubitemid 350171842)
    • (2007) Expert Review of Molecular Diagnostics , vol.7 , Issue.6 , pp. 793-804
    • May, A.1    Wang, T.J.2
  • 5
    • 34247142940 scopus 로고    scopus 로고
    • Use of BNP and CRP as biomarkers in assessing cardiovascular disease: Diagnosis versus risk
    • V.M. Miller, M.M. Redfield, and J.P. McConnell Use of BNP and CRP as biomarkers in assessing cardiovascular disease: diagnosis versus risk Current Vascular Pharmacology 5 2007 15 25
    • (2007) Current Vascular Pharmacology , vol.5 , pp. 15-25
    • Miller, V.M.1    Redfield, M.M.2    McConnell, J.P.3
  • 7
    • 57149092623 scopus 로고    scopus 로고
    • An Electrochemical immunosensor for C-reactive protein based on multi-walled carbon nanotube-modified electrodes
    • M. Buch, and J. Rishpon An Electrochemical immunosensor for C-reactive protein based on multi-walled carbon nanotube-modified electrodes Electroanalysis 20 2008 2592 2594
    • (2008) Electroanalysis , vol.20 , pp. 2592-2594
    • Buch, M.1    Rishpon, J.2
  • 8
    • 0037156465 scopus 로고    scopus 로고
    • Is high-sensitivity C-reactive protein an effective screening test for cardiovascular risk?
    • I. Kushner, and A.R. Sehgal Is high-sensitivity C-reactive protein an effective screening test for cardiovascular risk? Archives of Internal Medicine 162 2002 867 869 (Pubitemid 34299117)
    • (2002) Archives of Internal Medicine , vol.162 , Issue.8 , pp. 867-869
    • Kushner, I.1    Sehgal, A.R.2
  • 9
    • 0036400599 scopus 로고    scopus 로고
    • Elevated CRP levels predict poor prognosis of future cardiac events both in patients with coronary disease
    • L.R. Benzaquen, H. Yu, and N. Rifai Elevated CRP levels predict poor prognosis of future cardiac events both in patients with coronary disease Critical Reviews in Clinical Laboratory Sciences 39 2002 459 497
    • (2002) Critical Reviews in Clinical Laboratory Sciences , vol.39 , pp. 459-497
    • Benzaquen, L.R.1    Yu, H.2    Rifai, N.3
  • 10
    • 0037469232 scopus 로고    scopus 로고
    • Markers of inflammation and cardiovascular disease: Application to clinical and public health practice: A statement for healthcare professionals from the centers for disease control and prevention and the American Heart Association
    • DOI 10.1161/01.CIR.0000052939.59093.45
    • T.A. Pearson, G.A. Mensah, R.W. Alexander, J.L. Anderson, R.O. Cannon 3rd, M. Criqui, Y.Y. Fadl, S.P. Fortmann, Y. Hong, G.L. Myers, N. Rifai Jr., S. Smith, K.A. Taubert, R.P. Tracy, and F. Vinicor Markers of inflammation and cardiovascular disease: application to clinical and public health practice: a statement for healthcare professionals from the Centers for Disease Control and Prevention and the American Heart Association Circulation 107 2003 499 511 (Pubitemid 36158056)
    • (2003) Circulation , vol.107 , Issue.3 , pp. 499-511
    • Pearson, T.A.1    Mensah, G.A.2    Alexander, R.W.3    Anderson, J.L.4    Cannon III, R.O.5    Criqui, M.6    Fadl, Y.Y.7    Fortmann, S.P.8    Hong, Y.9    Myers, G.L.10    Rifai, N.11    Smith Jr., S.C.12    Taubert, K.13    Tracy, R.P.14    Vinicor, F.15
  • 11
    • 16544374872 scopus 로고    scopus 로고
    • Inflammation in atherothrombosis: How to use high-sensitivity C-reactive protein (hs-CRP) in clinical practice
    • P.M. Ridker Inflammation in atherothrombosis: how to use high-sensitivity C-reactive protein (hs-CRP) in clinical practice American Heart Hospital Journal 2 4 (Suppl. 1) 2004 4 9
    • (2004) American Heart Hospital Journal , vol.2 , Issue.4 SUPPL. 1 , pp. 4-9
    • Ridker, P.M.1
  • 12
  • 13
    • 0034034469 scopus 로고    scopus 로고
    • Evaluation of four automated high-sensitivity C-reactive protein methods: Implications for clinical and epidemiological applications
    • W.L. Roberts, R. Sedrick, L. Moulton, A. Spencer, and N. Rifai Evaluation of four automated high-sensitivity C-reactive protein methods: implications for clinical and epidemiological applications Clinical Chemistry 46 2000 461 468 (Pubitemid 30210716)
    • (2000) Clinical Chemistry , vol.46 , Issue.4 , pp. 461-468
    • Roberts, W.L.1    Sedrick, R.2    Moulton, L.3    Spencer, A.4    Rifai, N.5
  • 14
    • 0035106440 scopus 로고    scopus 로고
    • Evaluation of nine automated high-sensitivity c-reactive protein methods: Implications for clinical and epidemiological applications. Part 2
    • W.L. Roberts, L. Moulton, T.C. Law, G. Farrow, M. Cooper-Anderson, J. Savory, and N. Rifai Evaluation of nine automated high-sensitivity C-reactive protein methods: implications for clinical and epidemiological applications. Part 2 Clinical Chemistry 47 2001 418 425 (Pubitemid 32222454)
    • (2001) Clinical Chemistry , vol.47 , Issue.3 , pp. 418-425
    • Roberts, W.L.1    Moulton, L.2    Law, T.C.3    Farrow, G.4    Cooper-Anderson, M.5    Savory, J.6    Rifai, N.7
  • 15
    • 0031021084 scopus 로고    scopus 로고
    • Variability in the measurement of C-reactive protein in healthy subjects: Implications for reference intervals and epidemiological applications
    • E.M. Macy, T.E. Hayes, and R.P. Tracy Variability in the measurement of C-reactive protein in healthy subjects: implications for reference intervals and epidemiological applications Clinical Chemistry 43 1997 52 58 (Pubitemid 27024390)
    • (1997) Clinical Chemistry , vol.43 , Issue.1 , pp. 52-58
    • Macy, E.M.1    Hayes, T.E.2    Tracy, R.P.3
  • 16
    • 23844457439 scopus 로고    scopus 로고
    • CDC/AHA workshop on markers of inflammation and cardiovascular disease: Application to clinical and public health practice: Overview
    • T.A. Pearson, G.A. Mensah, Y.L. Hong, and S.C. Smith CDC/AHA workshop on markers of inflammation and cardiovascular disease: application to clinical and public health practice: overview Circulation 110 2004 E543 E544
    • (2004) Circulation , vol.110
    • Pearson, T.A.1    Mensah, G.A.2    Hong, Y.L.3    Smith, S.C.4
  • 17
    • 31044439705 scopus 로고    scopus 로고
    • Immunodetection of pentamer and modified C-reactive protein using surface plasmon resonance biosensing
    • DOI 10.1016/j.bios.2005.11.001, PII S0956566305003520
    • W.P. Hu, H.Y. Hsu, A. Chiou, K.Y. Tsens, H.I. Lin, G.L. Chang, and S.J. Chen Immunodetection of pentamer and modified C-reactive protein using surface plasmon resonance biosensing Biosensors and Bioelectronics 21 2006 1631 1637 (Pubitemid 43122031)
    • (2006) Biosensors and Bioelectronics , vol.21 , Issue.8 , pp. 1631-1637
    • Hu, W.P.1    Hsu, H.-Y.2    Chiou, A.3    Tseng, K.Y.4    Lin, H.-Y.5    Chang, G.L.6    Chen, S.-J.7
  • 18
    • 33645222733 scopus 로고    scopus 로고
    • SPR-based immunosensor for the CRP detection-A new method to detect a well know protein
    • M.H. Meyer, M. Hartmann, and M. Keusgen SPR-based immunosensor for the CRP detection-a new method to detect a well know protein Biosensors and Bioelectronics 21 2006 1987 1990
    • (2006) Biosensors and Bioelectronics , vol.21 , pp. 1987-1990
    • Meyer, M.H.1    Hartmann, M.2    Keusgen, M.3
  • 20
    • 71849110876 scopus 로고    scopus 로고
    • Development of indirect-competitive quartz crystal microbalance immunosensor for C-reactive protein
    • N. Kim, D.K. Kim, and Y.J. Cho Development of indirect-competitive quartz crystal microbalance immunosensor for C-reactive protein Sensors and Actuators B: Chemical 143 2009 444 448
    • (2009) Sensors and Actuators B: Chemical , vol.143 , pp. 444-448
    • Kim, N.1    Kim, D.K.2    Cho, Y.J.3
  • 21
    • 65549119731 scopus 로고    scopus 로고
    • Electrochemical investigations of the interaction of C-reactive protein (CRP) with a CRP antibody chemically immobilized on a gold surface
    • H. Hennessey, N. Afara, S. Omanovic, and A.L. Padjen Electrochemical investigations of the interaction of C-reactive protein (CRP) with a CRP antibody chemically immobilized on a gold surface Analytica Chimica Acta 643 2009 45 53
    • (2009) Analytica Chimica Acta , vol.643 , pp. 45-53
    • Hennessey, H.1    Afara, N.2    Omanovic, S.3    Padjen, A.L.4
  • 22
    • 41449091313 scopus 로고    scopus 로고
    • Electrochemical impedance immunosensor based on three-dimensionally ordered macroporous gold film
    • DOI 10.1021/ac7021376
    • X. Chen, Y. Wang, J. Zhou, W. Yan, X. Li, and J-J. Zhu Electrochemical impedance immunosensor based on three-dimensionally ordered macroporous gold film Analytical Chemistry 80 2008 2133 2140 (Pubitemid 351458063)
    • (2008) Analytical Chemistry , vol.80 , Issue.6 , pp. 2133-2140
    • Chen, X.1    Wang, Y.2    Zhou, J.3    Yan, W.4    Li, X.5    Zhu, J.-J.6
  • 23
    • 77955402570 scopus 로고    scopus 로고
    • Label-free RNA aptamer-based capacitive biosensor for the detection of C-reactive protein
    • A. Qureshi, Y. Gurbuz, S. Kallempudi, and J.H. Niazi Label-free RNA aptamer-based capacitive biosensor for the detection of C-reactive protein Physical Chemistry Chemical Physics 12 2010 9176 9182
    • (2010) Physical Chemistry Chemical Physics , vol.12 , pp. 9176-9182
    • Qureshi, A.1    Gurbuz, Y.2    Kallempudi, S.3    Niazi, J.H.4
  • 24
    • 0141868926 scopus 로고    scopus 로고
    • Nanoparticle-based bio-bar codes for the ultrasensitive detection of proteins
    • DOI 10.1126/science.1088755
    • J.M. Nam, C.S. Thaxton, and C.A. Mirkin Nanoparticle-based bio-bar codes for the ultrasensitive detection of proteins Science 301 2003 1884 1886 (Pubitemid 37221389)
    • (2003) Science , vol.301 , Issue.5641 , pp. 1884-1886
    • Nam, J.-M.1    Thaxton, C.S.2    Mirkin, C.A.3
  • 25
    • 18044390709 scopus 로고    scopus 로고
    • Microfluidic immunosensor systems
    • DOI 10.1016/j.bios.2004.10.016, 20th Anniversary of Biosendors and Bioelectronics
    • A. Bange, H.B. Halsall, and W.R. Heineman Microfluidic immunosensor systems Biosensors and Bioelectronics 20 2005 2488 2503 (Pubitemid 40602185)
    • (2005) Biosensors and Bioelectronics , vol.20 , Issue.12 , pp. 2488-2503
    • Bange, A.1    Halsall, H.B.2    Heineman, W.R.3
  • 26
    • 17944366258 scopus 로고    scopus 로고
    • Nanostructures in biodiagnostics
    • DOI 10.1021/cr030067f
    • N.L. Rosi, and C.A. Mirkin Nanostructures in biodiagnostics Chemical Reviews 105 2005 1547 1562 (Pubitemid 40596871)
    • (2005) Chemical Reviews , vol.105 , Issue.4 , pp. 1547-1562
    • Rosi, N.L.1    Mirkin, C.A.2
  • 27
    • 31044451214 scopus 로고    scopus 로고
    • State of the art and recent advances in immunoanalytical systems
    • DOI 10.1016/j.bios.2004.09.037, PII S095656630500357X
    • C.A. Marquette, and L.J. Blum State of the art and recent advances in immunoanalytical systems Biosensors and Bioelectronics 2 2006 1424 1433 (Pubitemid 43122006)
    • (2006) Biosensors and Bioelectronics , vol.21 , Issue.8 , pp. 1424-1433
    • Marquette, C.A.1    Blum, L.J.2
  • 28
    • 33645748230 scopus 로고    scopus 로고
    • A sensitive and high-throughput assay to detect low-abundance proteins in serum
    • H. Zhang, X. Cheng, M. Richter, and M.I. Greene A sensitive and high-throughput assay to detect low-abundance proteins in serum Nature Medicine 12 2006 473 477
    • (2006) Nature Medicine , vol.12 , pp. 473-477
    • Zhang, H.1    Cheng, X.2    Richter, M.3    Greene, M.I.4
  • 29
    • 33847363903 scopus 로고    scopus 로고
    • Integrated nanoparticle-biomolecule systems for biosensing and bioelectronics
    • DOI 10.1016/j.bios.2006.09.018, PII S0956566306004489, Selected Papers from the Ninth World Congress On Biosensors
    • I. Willner, R. Baron, and B. Willner Integrated nanoparticle-biomolecule systems for biosensing and bioelectronics Biosensors and Bioelectronics 22 2007 1841 1852 (Pubitemid 46349651)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.9-10 , pp. 1841-1852
    • Willner, I.1    Baron, R.2    Willner, B.3
  • 30
    • 84863429643 scopus 로고    scopus 로고
    • Disposable amperometric magneto-immunosensor for direct detection of tetracyclines antibiotics residues in milk
    • F. Conzuelo, M. Gamella, S. Campuzano, A.J. Reviejo, and J.M. Pingarrón Disposable amperometric magneto-immunosensor for direct detection of tetracyclines antibiotics residues in milk Analytica Chimica Acta 737 2012 29 36
    • (2012) Analytica Chimica Acta , vol.737 , pp. 29-36
    • Conzuelo, F.1    Gamella, M.2    Campuzano, S.3    Reviejo, A.J.4    Pingarrón, J.M.5
  • 32
    • 33645221091 scopus 로고    scopus 로고
    • Electrochemical biosensing of pesticide residues based on affinity biocomposite platforms
    • E. Zacco, M.I. Pividori, S. Alegret, R. Galve, and M.P. Marco Electrochemical biosensing of pesticide residues based on affinity biocomposite platforms Analytical Chemistry 78 2006 1780 1788
    • (2006) Analytical Chemistry , vol.78 , pp. 1780-1788
    • Zacco, E.1    Pividori, M.I.2    Alegret, S.3    Galve, R.4    Marco, M.P.5
  • 33
    • 81255191975 scopus 로고    scopus 로고
    • 4@Au magnetic nanoparticles attracted on Fe (III) phtalocyanine/chitosan-membrane modified screen-printed carbon electrode by a magnet
    • 4@Au magnetic nanoparticles attracted on Fe (III) phtalocyanine/chitosan-membrane modified screen-printed carbon electrode by a magnet Applied Mechanics and Materials 110-116 2012 519 526
    • (2012) Applied Mechanics and Materials , vol.110-116 , pp. 519-526
    • Gan, N.1    Meng, L.2    Hu, F.3    Cao, Y.4    Wu, Y.5    Jia, L.6    Zheng, L.7
  • 34
    • 0031837925 scopus 로고    scopus 로고
    • C-reactive protein in orthopedics
    • C. Foglar, and R.W. Lindsey C-reactive protein in orthopedics Orthopedics 21 6 1998 687 691 (Pubitemid 28277946)
    • (1998) Orthopedics , vol.21 , Issue.6 , pp. 687-691
    • Foglar, C.1    Lindsey, R.W.2
  • 35
    • 0020478887 scopus 로고
    • The horseradish peroxidase-catalyzed oxidation of 3,5,3′,5′- tetramethylbenzidine. Free radical and charge-transfer complex intermediates
    • P.D. Josephy, T. Eling, and R.P. Mason The horseradish peroxidase-catalyzed oxidation of 3,5,3′,5′-tetramethylbenzidine. Free radical and charge-transfer complex intermediates Journal of Biological Chemistry 257 1982 3669 3675
    • (1982) Journal of Biological Chemistry , vol.257 , pp. 3669-3675
    • Josephy, P.D.1    Eling, T.2    Mason, R.P.3
  • 36
    • 84878640538 scopus 로고    scopus 로고
    • Disposable amperometric magnetoimmunosensor for the sensitive detection of the cardiac biomarker amino-terminal pro-B-type natriuretic peptide in human serum
    • B. Esteban-Fernández de Ávila, V. Escamilla-Gómez, S. Campuzano, M. Pedrero, and J.M. Pingarrón Disposable amperometric magnetoimmunosensor for the sensitive detection of the cardiac biomarker amino-terminal pro-B-type natriuretic peptide in human serum Analytica Chimica Acta 784 2013 18 24
    • (2013) Analytica Chimica Acta , vol.784 , pp. 18-24
    • Esteban-Fernández De Ávila, B.1    Escamilla-Gómez, V.2    Campuzano, S.3    Pedrero, M.4    Pingarrón, J.M.5
  • 37
    • 57449117698 scopus 로고    scopus 로고
    • Impedance biosensor for peanut protein ara h 1
    • Y. Huang, M.C. Bell, and I.I. Suni Impedance biosensor for peanut protein ara h 1 Analytical Chemistry 80 2008 9157 9161
    • (2008) Analytical Chemistry , vol.80 , pp. 9157-9161
    • Huang, Y.1    Bell, M.C.2    Suni, I.I.3
  • 39
    • 10044280713 scopus 로고    scopus 로고
    • 2+-containing microspheres
    • DOI 10.1021/ac048782s
    • 2+-containing microspheres Analytical Chemistry 76 2004 7109 7113 (Pubitemid 39600887)
    • (2004) Analytical Chemistry , vol.76 , Issue.23 , pp. 7109-7113
    • Miao, W.1    Bard, A.J.2
  • 40
    • 33846240853 scopus 로고    scopus 로고
    • 2+-encapsulated liposomes as labels
    • DOI 10.1021/ac061336f
    • 2+-encapsulated liposomes labels Analytical Chemistry 79 2007 459 463 (Pubitemid 46106110)
    • (2007) Analytical Chemistry , vol.79 , Issue.2 , pp. 459-463
    • Zhan, W.1    Bard, A.J.2
  • 42
    • 77749286719 scopus 로고    scopus 로고
    • Rajesh Electrochemical characterization of surface modified gold electrode for the detection of C-reactive protein
    • N. Puri, V.K. Tanwar, V. Sharma, T. Ahuja, and A.M. Biradar Rajesh Electrochemical characterization of surface modified gold electrode for the detection of C-reactive protein International Journal of Integrative Biology 9 2009 1 5
    • (2009) International Journal of Integrative Biology , vol.9 , pp. 1-5
    • Puri, N.1    Tanwar, V.K.2    Sharma, V.3    Ahuja, T.4    Biradar, A.M.5
  • 43
    • 78149489834 scopus 로고    scopus 로고
    • Electrochemical immunosensor for simultaneous detection of dual cardiac markers based on a poly(dimethylsiloxane)-gold nanoparticles composite microfluidic chip: A proof of principle
    • F. Zhou, M. Lu, W. Wang, Z-P. Bian, J-R. Zhang, and J-J. Zhu Electrochemical immunosensor for simultaneous detection of dual cardiac markers based on a poly(dimethylsiloxane)-gold nanoparticles composite microfluidic chip: a proof of principle Clinical Chemistry 56 2010 1701 1707
    • (2010) Clinical Chemistry , vol.56 , pp. 1701-1707
    • Zhou, F.1    Lu, M.2    Wang, W.3    Bian, Z.-P.4    Zhang, J.-R.5    Zhu, J.-J.6
  • 44
    • 77952582105 scopus 로고    scopus 로고
    • Label-free capacitive biosensor for sensitive detection of multiple biomarkers using gold interdigitated capacitor arrays
    • A. Qureshi, J.H. Niazi, S. Kallempudi, and Y. Gurbuz Label-free capacitive biosensor for sensitive detection of multiple biomarkers using gold interdigitated capacitor arrays Biosensors and Bioelectronics 25 2010 2318 2323
    • (2010) Biosensors and Bioelectronics , vol.25 , pp. 2318-2323
    • Qureshi, A.1    Niazi, J.H.2    Kallempudi, S.3    Gurbuz, Y.4
  • 45
    • 84865764290 scopus 로고    scopus 로고
    • An optimised electrochemical biosensor for the label free detection of C-reactive protein in blood
    • T. Bryan, X. Luo, P.R. Bueno, and J.J. Davis An optimised electrochemical biosensor for the label free detection of C-reactive protein in blood Biosensors and Bioelectronics 39 2013 94 98
    • (2013) Biosensors and Bioelectronics , vol.39 , pp. 94-98
    • Bryan, T.1    Luo, X.2    Bueno, P.R.3    Davis, J.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.