Volumn 56, Issue 8, 2015, Pages 1285-1291

Beyond 18F-FDG: Characterization of PET/CT and PET/MR scanners for a comprehensive set of positron emitters of growing application-18F, 11C, 89Zr, 124I,68Ga, and 90Y

Author keywords

Contrast recovery; Image quality; Positron emission tomography; Radionuclide therapy; Spatial resolution

Indexed keywords

CARBON 11; FLUORINE 18; GALLIUM 68; IODINE 124; RADIOISOTOPE; UNCLASSIFIED DRUG; YTTRIUM 90; ZIRCONIUM 89; CARBON; CONTRAST MEDIUM; FLUORINE; FLUORODEOXYGLUCOSE F 18; GALLIUM; RADIOACTIVE IODINE; RADIOPHARMACEUTICAL AGENT; YTTRIUM; ZIRCONIUM;

EID: 84938848805     PISSN: 01615505     EISSN: 2159662X     Source Type: Journal    
DOI: 10.2967/jnumed.115.156711     Document Type: Article
Times cited : (42)

References (39)
  • 1
    • 0021355477 scopus 로고
    • Brain oxygen utilization measured with O-15 radiotracers and positron emission tomography
    • Mintun MA, Raichle ME, Martin WR, Herscovitch P. Brain oxygen utilization measured with O-15 radiotracers and positron emission tomography. J Nucl Med. 1984;25:177-187.
    • (1984) J Nucl Med. , vol.25 , pp. 177-187
    • Mintun, M.A.1    Raichle, M.E.2    Martin, W.R.3    Herscovitch, P.4
  • 2
    • 0019450543 scopus 로고
    • N-13 ammonia as an indicator of myocardial blood flow
    • Schelbert HR, Phelps ME, Huang SC, et al. N-13 ammonia as an indicator of myocardial blood flow. Circulation. 1981;63:1259-1272.
    • (1981) Circulation. , vol.63 , pp. 1259-1272
    • Schelbert, H.R.1    Phelps, M.E.2    Huang, S.C.3
  • 4
    • 0031865378 scopus 로고    scopus 로고
    • PET imaging of prostate cancer using carbon-11-choline
    • Hara T, Kosaka N, Kishi H. PET imaging of prostate cancer using carbon-11-choline. J Nucl Med. 1998;39:990-995.
    • (1998) J Nucl Med. , vol.39 , pp. 990-995
    • Hara, T.1    Kosaka, N.2    Kishi, H.3
  • 7
    • 37549020260 scopus 로고    scopus 로고
    • Gallium-68 PET: A new frontier in receptor cancer imaging
    • Al-Nahhas A, Win Z, Szyszko T, et al. Gallium-68 PET: a new frontier in receptor cancer imaging. Anticancer Res. 2007;27:4087-4094.
    • (2007) Anticancer Res. , vol.27 , pp. 4087-4094
    • Al-Nahhas, A.1    Win, Z.2    Szyszko, T.3
  • 8
    • 14844355681 scopus 로고    scopus 로고
    • The promise of immuno-PET in radio-immunotherapy
    • Verel I, Visser GW, van Dongen GA. The promise of immuno-PET in radio-immunotherapy. J Nucl Med. 2005;46(suppl):164S-171S.
    • (2005) J Nucl Med. , vol.46 , pp. 164S-171S
    • Verel, I.1    Visser, G.W.2    Van Dongen, G.A.3
  • 9
    • 33646230063 scopus 로고    scopus 로고
    • Potential of immuno-positron emission tomography for tumor imaging and immunotherapy planning
    • Zalutsky MR. Potential of immuno-positron emission tomography for tumor imaging and immunotherapy planning. Clin Cancer Res. 2006;12:1958-1960.
    • (2006) Clin Cancer Res. , vol.12 , pp. 1958-1960
    • Zalutsky, M.R.1
  • 10
    • 60849128549 scopus 로고    scopus 로고
    • Monoclonal antibodies as innovative therapeutics
    • Reichert JM. Monoclonal antibodies as innovative therapeutics. Curr Pharm Biotechnol. 2008;9:423-430.
    • (2008) Curr Pharm Biotechnol. , vol.9 , pp. 423-430
    • Reichert, J.M.1
  • 11
    • 33947419410 scopus 로고    scopus 로고
    • Virus-associated tumor imaging by induction of viral gene expression
    • Fu D-X, Tanhehco YC, Chen J, et al. Virus-associated tumor imaging by induction of viral gene expression. Clin Cancer Res. 2007;13:1453-1458.
    • (2007) Clin Cancer Res. , vol.13 , pp. 1453-1458
    • Fu, D.-X.1    Tanhehco, Y.C.2    Chen, J.3
  • 14
    • 84880707765 scopus 로고    scopus 로고
    • Assessment of acquisition protocols for routine imaging of Y-90 using PET/CT
    • Carlier T, Eugène T, Bodet-Milin C, et al. Assessment of acquisition protocols for routine imaging of Y-90 using PET/CT. EJNMMI Res. 2013;3:11.
    • (2013) EJNMMI Res. , vol.3 , pp. 11
    • Carlier, T.1    Eugène, T.2    Bodet-Milin, C.3
  • 15
    • 67649158603 scopus 로고    scopus 로고
    • Correction technique for cascade gammas in I-124 imaging on a fully-3D, time-of-flight PET scanner
    • Surti S, Scheuermann R, Karp JS. Correction technique for cascade gammas in I-124 imaging on a fully-3D, time-of-flight PET scanner. IEEE Trans Nucl Sci. 2009;56:653-660.
    • (2009) IEEE Trans Nucl Sci. , vol.56 , pp. 653-660
    • Surti, S.1    Scheuermann, R.2    Karp, J.S.3
  • 18
    • 83755161889 scopus 로고    scopus 로고
    • Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner
    • Delso G, Furst S, Jakoby B, et al. Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner. J Nucl Med. 2011;52:1914-1922.
    • (2011) J Nucl Med. , vol.52 , pp. 1914-1922
    • Delso, G.1    Furst, S.2    Jakoby, B.3
  • 21
    • 12744281031 scopus 로고    scopus 로고
    • Performance of coincidence imaging with long-lived positron emitters as an alternative to dedicated PET and SPECT
    • Sandström M, Tolmachev V, Kairemo K, Lundqvist H, Lubberink M. Performance of coincidence imaging with long-lived positron emitters as an alternative to dedicated PET and SPECT Phys Med Biol. 2004;49:5419-5432.
    • (2004) Phys Med Biol. , vol.49 , pp. 5419-5432
    • Sandström, M.1    Tolmachev, V.2    Kairemo, K.3    Lundqvist, H.4    Lubberink, M.5
  • 23
    • 44249097810 scopus 로고    scopus 로고
    • Image quality with non-standard nuclides in PET
    • Laforest R, Liu X. Image quality with non-standard nuclides in PET. Q J Nucl Med Mol Imaging. 2008;52:151-158.
    • (2008) Q J Nucl Med Mol Imaging. , vol.52 , pp. 151-158
    • Laforest, R.1    Liu, X.2
  • 24
    • 77950951879 scopus 로고    scopus 로고
    • Image-quality assessment for several positron emitters using the NEMA NU 4-2008 standards in the Siemens Inveon small-animal PET scanner
    • Disselhorst JA, Brom M, Laverman P, et al. Image-quality assessment for several positron emitters using the NEMA NU 4-2008 standards in the Siemens Inveon small-animal PET scanner. J Nucl Med. 2010;51:610-617.
    • (2010) J Nucl Med. , vol.51 , pp. 610-617
    • Disselhorst, J.A.1    Brom, M.2    Laverman, P.3
  • 26
    • 84881440615 scopus 로고    scopus 로고
    • Systematic evaluation of phantom fluids for simultaneous PET/MR hybrid imaging
    • Ziegler S, Braun H, Ritt P, Hocke C, Kuwert T, Quick HH. Systematic evaluation of phantom fluids for simultaneous PET/MR hybrid imaging. J Nucl Med. 2013;54:1464-1471.
    • (2013) J Nucl Med. , vol.54 , pp. 1464-1471
    • Ziegler, S.1    Braun, H.2    Ritt, P.3    Hocke, C.4    Kuwert, T.5    Quick, H.H.6
  • 28
    • 79960321124 scopus 로고    scopus 로고
    • 18F of the ARGUS small-animal PET scanner based on the NEMA NU-4 standard
    • 18F of the ARGUS small-animal PET scanner based on the NEMA NU-4 standard. IEEE Nucl Sci Conf Rec. 2010;3454-3457.
    • (2010) IEEE Nucl Sci Conf Rec. , pp. 3454-3457
    • Canadas, M.1    Sanz, E.R.2    Vives, M.O.3
  • 29
    • 84883180389 scopus 로고    scopus 로고
    • Is the image quality of I-124-PET impaired by an automatic correction of prompt gammas?
    • Preylowski V, Schlögl S, Schoenahl F, et al. Is the image quality of I-124-PET impaired by an automatic correction of prompt gammas? PLoS ONE. 2013;8: e71729.
    • (2013) PLoS ONE. , vol.8 , pp. e71729
    • Preylowski, V.1    Schlögl, S.2    Schoenahl, F.3
  • 31
    • 84923918246 scopus 로고    scopus 로고
    • Quantitative and qualitative assessment of yttrium-90 PET/CT imaging
    • Attarwala AA, Molina-Duran F, Büsing K-A, et al. Quantitative and qualitative assessment of yttrium-90 PET/CT imaging. PLoS One. 2014;9:e110401.
    • (2014) PLoS One. , vol.9 , pp. e110401
    • Attarwala, A.A.1    Molina-Duran, F.2    Büsing, K.-A.3
  • 34
    • 1642430605 scopus 로고    scopus 로고
    • Larsson SA Positron flight in human tissues and its influence on PET image spatial resolution
    • Sánchez-Crespo A, Andreo P, Larsson SA Positron flight in human tissues and its influence on PET image spatial resolution. Eur J Nucl Med Mol Imaging. 2004;31:44-51.
    • (2004) Eur J Nucl Med Mol Imaging. , vol.31 , pp. 44-51
    • Sánchez-Crespo, A.1    Andreo, P.2
  • 35
    • 84872723047 scopus 로고    scopus 로고
    • Physics and applications of positron beams in an integrated PET/MR
    • Watson CC, Eriksson L, Kolb A. Physics and applications of positron beams in an integrated PET/MR. Phys Med Biol. 2013;58:L1-L12.
    • (2013) Phys Med Biol. , vol.58 , pp. L1-L12
    • Watson, C.C.1    Eriksson, L.2    Kolb, A.3
  • 36
    • 84867582847 scopus 로고    scopus 로고
    • Simulation study of tissue-specific positron range correction for the new Biograph mMR whole-body PET/MR system
    • Kraus R, Delso G, Ziegler SI. Simulation study of tissue-specific positron range correction for the new Biograph mMR whole-body PET/MR system. IEEE Trans Nucl Sci. 2012;59:1900-1909.
    • (2012) IEEE Trans Nucl Sci. , vol.59 , pp. 1900-1909
    • Kraus, R.1    Delso, G.2    Ziegler, S.I.3
  • 37
    • 84893229443 scopus 로고    scopus 로고
    • Accessed December 30, 2014
    • Data RD. Health Physics Society. http://hps.org/publicinformation/radardecay-data.cfm. Accessed December 30, 2014.
    • Health Physics Society
    • Data, R.D.1
  • 38
    • 84938903763 scopus 로고    scopus 로고
    • Stopping-power and range tables for electrons. National Institute of Standards and Technology website Accessed December 30, 2014
    • Stopping-power and range tables for electrons. National Institute of Standards and Technology website. http://physics.nist.gov/PhysRefData/Star/Text/ESTAR. html. Accessed December 30, 2014.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.