메뉴 건너뛰기




Volumn 46, Issue 1 SUPPL., 2005, Pages

The promise of immuno-PET in radioimmunotherapy

Author keywords

Immuno PET; Monoclonal antibodies; Oncology; Positron emitters; Radioimmunotherapy

Indexed keywords

BROMINE 76; CARCINOEMBRYONIC ANTIGEN; COPPER 64; COPPER 67; GALLIUM 67; IBRITUMOMAB TIUXETAN; IODINE 123; IODINE 124; RADIOISOTOPE; RHENIUM 186; RHENIUM 188; STRONTIUM 89; TECHNETIUM 99M; TOSITUMOMAB I 131; YTTRIUM 90; DIAGNOSTIC AGENT; MONOCLONAL ANTIBODY; RADIOPHARMACEUTICAL AGENT;

EID: 14844355681     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (145)

References (40)
  • 1
    • 0037363643 scopus 로고    scopus 로고
    • 90Y-ibritumomab tiuxetan radioimmunotherapy for relapsed or refractory non-hodgkin's lymphoma: Combined data from 4 clinical trials
    • 90Y-ibritumomab tiuxetan radioimmunotherapy for relapsed or refractory non-hodgkin's lymphoma: combined data from 4 clinical trials. J Nucl Med. 2003;44:465- 474.
    • (2003) J Nucl Med , vol.44 , pp. 465-474
    • Wiseman, G.A.1    Kornmehl, E.2    Leigh, B.3
  • 2
    • 0037397263 scopus 로고    scopus 로고
    • The clinical importance of dosimetry in radioimmunotherapy with tositumomab and iodine I-131 tositumomab
    • Wahl RL. The clinical importance of dosimetry in radioimmunotherapy with tositumomab and iodine I-131 tositumomab. Semin Oncol. 2003;30:31-38.
    • (2003) Semin Oncol , vol.30 , pp. 31-38
    • Wahl, R.L.1
  • 4
    • 0642372172 scopus 로고    scopus 로고
    • 90Y-labeled monoclonal antibodies in xenograft-bearing nude mice
    • 90Y-labeled monoclonal antibodies in xenograft-bearing nude mice. J Nucl Med. 2003;44:1663-1670.
    • (2003) J Nucl Med , vol.44 , pp. 1663-1670
    • Verel, I.1    Visser, G.W.M.2    Boellaard, R.3
  • 5
    • 0016631386 scopus 로고
    • Application of annihilation coincidence detection to transaxial reconstruction tomography
    • Phelps ME, Hoffman EJ, Mullani NA, Ter-Pogossian MM. Application of annihilation coincidence detection to transaxial reconstruction tomography. J Nucl Med. 1975;16:210-224.
    • (1975) J Nucl Med , vol.16 , pp. 210-224
    • Phelps, M.E.1    Hoffman, E.J.2    Mullani, N.A.3    Ter-Pogossian, M.M.4
  • 6
    • 0034092414 scopus 로고    scopus 로고
    • Scintillation crystals for PET
    • Melcher CL. Scintillation crystals for PET. J Nucl Med. 2000;41:1051-1055.
    • (2000) J Nucl Med , vol.41 , pp. 1051-1055
    • Melcher, C.L.1
  • 8
    • 35448985542 scopus 로고    scopus 로고
    • Czernin J, Schelbert H. PET/CT imaging: facts, opinions, hopes, and questions. J Nucl Med. 2004;45(suppl):1S-3S.
    • Czernin J, Schelbert H. PET/CT imaging: facts, opinions, hopes, and questions. J Nucl Med. 2004;45(suppl):1S-3S.
  • 9
    • 0034185878 scopus 로고    scopus 로고
    • 94mTc for positron emission tomography studies
    • 94mTc for positron emission tomography studies. Nucl Med Biol. 2000;27:323-328.
    • (2000) Nucl Med Biol , vol.27 , pp. 323-328
    • Qaim, S.M.1
  • 10
    • 0035139545 scopus 로고    scopus 로고
    • Device-dependent activity estimation and decay correction of radionuclide mixtures with application to Tc-94m PET studies
    • Smith MF, Daube-Witherspoon ME, Plascjak PS, et al. Device-dependent activity estimation and decay correction of radionuclide mixtures with application to Tc-94m PET studies. Med Phys. 2001;28:36-45.
    • (2001) Med Phys , vol.28 , pp. 36-45
    • Smith, M.F.1    Daube-Witherspoon, M.E.2    Plascjak, P.S.3
  • 11
    • 0030696927 scopus 로고    scopus 로고
    • Alternative positron emission tomography with non-conventional positron emitters: Effects of their physical properties on image quality and potential clinical applications
    • Pagani M, Stone-Elander S, Larsson SA. Alternative positron emission tomography with non-conventional positron emitters: effects of their physical properties on image quality and potential clinical applications. Eur J Nucl Med. 1997;24:1301-1327.
    • (1997) Eur J Nucl Med , vol.24 , pp. 1301-1327
    • Pagani, M.1    Stone-Elander, S.2    Larsson, S.A.3
  • 12
    • 0043163867 scopus 로고    scopus 로고
    • Applications of positron-emitting halogens in PET oncology
    • Glaser M, Luthra SK, Brady F. Applications of positron-emitting halogens in PET oncology. Int J Oncol. 2003;22:253-267.
    • (2003) Int J Oncol , vol.22 , pp. 253-267
    • Glaser, M.1    Luthra, S.K.2    Brady, F.3
  • 16
    • 0038546640 scopus 로고    scopus 로고
    • Quantitation in PET using isotopes emitting prompt single gammas: Application to yttrium-86
    • Walrand S, Jamar F, Mathieu I, et al. Quantitation in PET using isotopes emitting prompt single gammas: application to yttrium-86. Eur J Nucl Med. 2003;30:354-361.
    • (2003) Eur J Nucl Med , vol.30 , pp. 354-361
    • Walrand, S.1    Jamar, F.2    Mathieu, I.3
  • 19
    • 10144230692 scopus 로고    scopus 로고
    • Quantitative imaging of iodine-124 with PET
    • Pentlow KS, Graham MC, Lambrecht RM, et al. Quantitative imaging of iodine-124 with PET. J Nucl Med. 1996;37:1557-1562.
    • (1996) J Nucl Med , vol.37 , pp. 1557-1562
    • Pentlow, K.S.1    Graham, M.C.2    Lambrecht, R.M.3
  • 21
    • 35448956632 scopus 로고    scopus 로고
    • Sowby FD, ed. Radionuclide Transformations: Energy and Intensity of Emissions. International Commission on Radiological Protection Publication 38. 11-13. Oxford, UK: Pergamon Press; 1983:14, 74, 90, 144, 202, 218, 249, 444.
    • Sowby FD, ed. Radionuclide Transformations: Energy and Intensity of Emissions. International Commission on Radiological Protection Publication 38. Vol. 11-13. Oxford, UK: Pergamon Press; 1983:14, 74, 90, 144, 202, 218, 249, 444.
  • 22
    • 35448969522 scopus 로고    scopus 로고
    • Kinsey RR, ed. The NuDat Program for Nuclear Data on the Web. Version 2.5. Available at:, Accessed September 1, 2004
    • Kinsey RR, ed. The NuDat Program for Nuclear Data on the Web. Version 2.5. Available at: http://www.nndc.bnl.gov/nndc/nudat/. Accessed September 1, 2004.
  • 24
    • 0028973279 scopus 로고
    • 125I-labeled anti-Tac disulfide-stabilized Fv fragments in nude mice with interleukin 2 alpha receptor-positive tumor xenografts
    • 125I-labeled anti-Tac disulfide-stabilized Fv fragments in nude mice with interleukin 2 alpha receptor-positive tumor xenografts. Cancer Res. 1995;55:5323-5329.
    • (1995) Cancer Res , vol.55 , pp. 5323-5329
    • Choi, C.W.1    Lang, L.2    Lee, J.T.3
  • 25
    • 0032694503 scopus 로고    scopus 로고
    • Radiolabeling of an anti-carcinoembryonic antigen antibody Fab-′ fragment (CEA-scan) with the positron-emitting radionuclide Tc-94m
    • Griffiths GL, Goldenberg DM, Roesch F, Hansen HJ. Radiolabeling of an anti-carcinoembryonic antigen antibody Fab-′ fragment (CEA-scan) with the positron-emitting radionuclide Tc-94m. Clin Cancer Res. 1999;5:3001s-3003s.
    • (1999) Clin Cancer Res , vol.5
    • Griffiths, G.L.1    Goldenberg, D.M.2    Roesch, F.3    Hansen, H.J.4
  • 26
    • 0031666670 scopus 로고    scopus 로고
    • Gallium-68 chelate imaging of human colon carcinoma xenografts pretargeted with bispecific anti-CD44V6/anti-gallium chelate antibodies
    • Klivényi G, Schuhmacher J, Patzelt E, et al. Gallium-68 chelate imaging of human colon carcinoma xenografts pretargeted with bispecific anti-CD44V6/anti-gallium chelate antibodies. J Nucl Med. 1998;39:1769-1776.
    • (1998) J Nucl Med , vol.39 , pp. 1769-1776
    • Klivényi, G.1    Schuhmacher, J.2    Patzelt, E.3
  • 27
    • 0035328530 scopus 로고    scopus 로고
    • Immunoscintigraphy with PET: Ga-68 chelate imaging of breast cancer pretargeted with bispecific anti-MUC1/anti-Ga chelate antibodies
    • Schuhmacher J, Kaul S, Klivényi G, et al. Immunoscintigraphy with PET: Ga-68 chelate imaging of breast cancer pretargeted with bispecific anti-MUC1/anti-Ga chelate antibodies. Cancer Res. 2001;61:3712-3717.
    • (2001) Cancer Res , vol.61 , pp. 3712-3717
    • Schuhmacher, J.1    Kaul, S.2    Klivényi, G.3
  • 29
    • 0028786707 scopus 로고
    • RadioimmunoPET: Detection of colorectal carcinoma with positron-emitting copper-64-labeled monoclonal antibody
    • Philpott GW, Schwarz SW, Anderson CJ, et al. RadioimmunoPET: detection of colorectal carcinoma with positron-emitting copper-64-labeled monoclonal antibody. J Nucl Med. 1995;36:1818-1824.
    • (1995) J Nucl Med , vol.36 , pp. 1818-1824
    • Philpott, G.W.1    Schwarz, S.W.2    Anderson, C.J.3
  • 30
    • 0242353714 scopus 로고    scopus 로고
    • High-resolution microPET imaging of carcinoembryonic antigen-positive xenografts by using a copper-64-labeled engineered antibody fragment
    • Wu AM, Yazaki PJ, Tsai S, et al. High-resolution microPET imaging of carcinoembryonic antigen-positive xenografts by using a copper-64-labeled engineered antibody fragment. Proc Natl Acad Sci USA. 2000;97:8495-8500.
    • (2000) Proc Natl Acad Sci USA , vol.97 , pp. 8495-8500
    • Wu, A.M.1    Yazaki, P.J.2    Tsai, S.3
  • 33
    • 1842338078 scopus 로고    scopus 로고
    • Pharmacokinetics and experimental PET imaging of a bromine-76-labeled monoclonal anti-CEA antibody
    • Lövqvist A, Sundin A, Alström H, Carlsson J, Lundqvist H. Pharmacokinetics and experimental PET imaging of a bromine-76-labeled monoclonal anti-CEA antibody. J Nucl Med. 1997;38:395-401.
    • (1997) J Nucl Med , vol.38 , pp. 395-401
    • Lövqvist, A.1    Sundin, A.2    Alström, H.3    Carlsson, J.4    Lundqvist, H.5
  • 34
    • 0025349085 scopus 로고
    • 124I-labelled monoclonal antibody H17E2 in a human tumour xenograft model. A prelude to positron emission tomography (PET)
    • 124I-labelled monoclonal antibody H17E2 in a human tumour xenograft model. A prelude to positron emission tomography (PET). Br J Cancer 1990;10(suppl):89-91.
    • (1990) Br J Cancer , vol.10 , Issue.SUPPL. , pp. 89-91
    • Snook, D.E.1    Rowlinson-Busza, G.2    Sharma, H.L.3    Epenetos, A.A.4
  • 35
    • 0025762453 scopus 로고
    • Radioimmuno positron emission tomography with monoclonal antibodies: A new approach to quantifying in vivo tumour concentration and biodistribution for radioimmunotherapy
    • Westera G, Reist HW, Buchegger F, et al. Radioimmuno positron emission tomography with monoclonal antibodies: a new approach to quantifying in vivo tumour concentration and biodistribution for radioimmunotherapy. Nucl Med Commun. 1991;12:429-437.
    • (1991) Nucl Med Commun , vol.12 , pp. 429-437
    • Westera, G.1    Reist, H.W.2    Buchegger, F.3
  • 36
    • 0026592062 scopus 로고
    • PET scanning of iodine-124-3F8 as an approach to tumor dosimetry during treatment planning for radioimmunotherapy in a child with neuroblastoma
    • Larson SM, Pentlow KS, Volkow ND, et al. PET scanning of iodine-124-3F8 as an approach to tumor dosimetry during treatment planning for radioimmunotherapy in a child with neuroblastoma. J Nucl Med. 1992;33:2020-2023.
    • (1992) J Nucl Med , vol.33 , pp. 2020-2023
    • Larson, S.M.1    Pentlow, K.S.2    Volkow, N.D.3
  • 38
    • 0035012711 scopus 로고    scopus 로고
    • 124I-CDR-grafted humanized A33 monoclonal antibody
    • 124I-CDR-grafted humanized A33 monoclonal antibody. J Nucl Med. 2001;42:764-769.
    • (2001) J Nucl Med , vol.42 , pp. 764-769
    • Lee, F.T.1    Hall, C.2    Rigopoulos, A.3
  • 39
    • 1542681650 scopus 로고    scopus 로고
    • 124I-labeled engineered anti-CEA minibodies and diabodies allow high-contrast, antigen-specific small-animal PET imaging of xenografts in athymic mice
    • 124I-labeled engineered anti-CEA minibodies and diabodies allow high-contrast, antigen-specific small-animal PET imaging of xenografts in athymic mice. J Nucl Med. 2003;44:1962-1969.
    • (2003) J Nucl Med , vol.44 , pp. 1962-1969
    • Sunderesan, G.1    Yazaki, P.2    Shively, J.E.3
  • 40
    • 12144269425 scopus 로고    scopus 로고
    • 131I-radioimmunotherapy. Eur J Nucl Med Mol Imaging. July 31, 2004. [Epub ahead of print.]
    • 131I-radioimmunotherapy. Eur J Nucl Med Mol Imaging. July 31, 2004. [Epub ahead of print.]


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.