메뉴 건너뛰기




Volumn 42, Issue 2, 2015, Pages 210-213

Reliability and concurrent validity of the Microsoft Xbox One Kinect for assessment of standing balance and postural control

Author keywords

Balance; Functional reach; Kinect; Kinect V2; XBox One Kinect

Indexed keywords

ADULT; ARTICLE; BODY EQUILIBRIUM; COMPUTER; COMPUTER PROGRAM; CONCURRENT VALIDITY; ELECTRONIC SENSOR; FEMALE; HUMAN; HUMAN EXPERIMENT; KINEMATICS; MALE; MOTION ANALYSIS SYSTEM; MOTOR PERFORMANCE; NORMAL HUMAN; PELVIS; PRIORITY JOURNAL; STANDING; STERNUM; TEST RETEST RELIABILITY; THREE DIMENSIONAL IMAGING; TRUNK; YOUNG ADULT; ADOLESCENT; BIOMECHANICS; PHYSIOLOGY; REPRODUCIBILITY; VALIDATION STUDY; VIDEO GAME;

EID: 84937813437     PISSN: 09666362     EISSN: 18792219     Source Type: Journal    
DOI: 10.1016/j.gaitpost.2015.03.005     Document Type: Article
Times cited : (136)

References (10)
  • 1
    • 84897109909 scopus 로고    scopus 로고
    • Accuracy of the Microsoft Kinect sensor for measuring movement in people with Parkinson's disease
    • Galna B., Barry G., Jackson D., Mhiripiri D., Olivier P., Rochester L. Accuracy of the Microsoft Kinect sensor for measuring movement in people with Parkinson's disease. Gait Posture 2014, 39:1062-1068.
    • (2014) Gait Posture , vol.39 , pp. 1062-1068
    • Galna, B.1    Barry, G.2    Jackson, D.3    Mhiripiri, D.4    Olivier, P.5    Rochester, L.6
  • 2
    • 84918580559 scopus 로고    scopus 로고
    • Quantifying individual components of the timed up and go using the Kinect in people living with stroke
    • Vernon S., Paterson K., Bower K., McGinley J., Miller K., Pua Y.H., et al. Quantifying individual components of the timed up and go using the Kinect in people living with stroke. Neurorehab Neural Repair 2015, 29:48-53.
    • (2015) Neurorehab Neural Repair , vol.29 , pp. 48-53
    • Vernon, S.1    Paterson, K.2    Bower, K.3    McGinley, J.4    Miller, K.5    Pua, Y.H.6
  • 3
    • 84884977504 scopus 로고    scopus 로고
    • Validity of the Microsoft Kinect for providing lateral trunk lean feedback during gait retraining
    • Clark R.A., Pua Y.H., Bryant A.L., Hunt M.A. Validity of the Microsoft Kinect for providing lateral trunk lean feedback during gait retraining. Gait Posture 2013, 38:1064-1066.
    • (2013) Gait Posture , vol.38 , pp. 1064-1066
    • Clark, R.A.1    Pua, Y.H.2    Bryant, A.L.3    Hunt, M.A.4
  • 4
    • 84888302836 scopus 로고    scopus 로고
    • Validity and reliability of the Kinect within functional assessment activities: comparison with standard stereophotogrammetry
    • Bonnechère B., Jansen B., Salvia P., Bouzahouene H., Omelina L., Moiseev F., et al. Validity and reliability of the Kinect within functional assessment activities: comparison with standard stereophotogrammetry. Gait Posture 2014, 39:593-598.
    • (2014) Gait Posture , vol.39 , pp. 593-598
    • Bonnechère, B.1    Jansen, B.2    Salvia, P.3    Bouzahouene, H.4    Omelina, L.5    Moiseev, F.6
  • 7
    • 42149157772 scopus 로고    scopus 로고
    • Assessing control of postural stability in community-living older adults using performance-based limits of stability
    • Jbabdi M., Boissy P., Hamel M. Assessing control of postural stability in community-living older adults using performance-based limits of stability. BMC Geriatr 2008, 2008.
    • (2008) BMC Geriatr , pp. 2008
    • Jbabdi, M.1    Boissy, P.2    Hamel, M.3
  • 8
    • 75649119259 scopus 로고    scopus 로고
    • Confidence in Altman-Bland plots: a critical review of the method of differences
    • Ludbrook J. Confidence in Altman-Bland plots: a critical review of the method of differences. Clin Exp Pharmacol Physiol 2010, 37:143-149.
    • (2010) Clin Exp Pharmacol Physiol , vol.37 , pp. 143-149
    • Ludbrook, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.