메뉴 건너뛰기




Volumn 39, Issue 1, 2014, Pages 593-598

Validity and reliability of the Kinect within functional assessment activities: Comparison with standard stereophotogrammetry

Author keywords

Biomechanics; Markerless motion capture; Motion analysis; New technology

Indexed keywords

ABDUCTION; ADULT; ARTICLE; CONTROLLED STUDY; ELBOW FLEXION; ELECTRONIC SENSOR; FEMALE; FUNCTIONAL ASSESSMENT; HIP; HUMAN; HUMAN EXPERIMENT; IMAGING SOFTWARE; INTERMETHOD COMPARISON; KINECT SENSOR; KNEE FUNCTION; MALE; NORMAL HUMAN; PRIORITY JOURNAL; RANGE OF MOTION; REPRODUCIBILITY; SHOULDER; STEREOPHOTOGRAMMETRY; TEST RETEST RELIABILITY; VOLUNTEER;

EID: 84888302836     PISSN: 09666362     EISSN: 18792219     Source Type: Journal    
DOI: 10.1016/j.gaitpost.2013.09.018     Document Type: Article
Times cited : (214)

References (30)
  • 1
    • 38949177442 scopus 로고    scopus 로고
    • Human motion tracking for rehabilitation - a survey
    • Zhou H., Hu H. Human motion tracking for rehabilitation - a survey. Biomed Signal Process Control 2008, 3:1-18.
    • (2008) Biomed Signal Process Control , vol.3 , pp. 1-18
    • Zhou, H.1    Hu, H.2
  • 3
    • 49449118813 scopus 로고    scopus 로고
    • Systematic accuracy and precision analysis of video motion capturing systems - exemplified on the Vicon-460 system
    • Windolf M., Götzen N., Morlock M. Systematic accuracy and precision analysis of video motion capturing systems - exemplified on the Vicon-460 system. J Biochem 2008, 41(12):2776-2780.
    • (2008) J Biochem , vol.41 , Issue.12 , pp. 2776-2780
    • Windolf, M.1    Götzen, N.2    Morlock, M.3
  • 4
    • 19644373467 scopus 로고    scopus 로고
    • Human movement analysis using stereophotogrammetry. Part 4: assessment of anatomical landmark misplacement and its effects on joint kinematics
    • Della Croce U., Leardini A., Chiaria L., Cappozzo A. Human movement analysis using stereophotogrammetry. Part 4: assessment of anatomical landmark misplacement and its effects on joint kinematics. Gait Posture 2005, 21(2):226-237.
    • (2005) Gait Posture , vol.21 , Issue.2 , pp. 226-237
    • Della Croce, U.1    Leardini, A.2    Chiaria, L.3    Cappozzo, A.4
  • 5
    • 21844468932 scopus 로고    scopus 로고
    • On the influence of soft tissue coverage in the determination of bone kinematics using skin markers
    • Taylor W.R., Ehrig R.M., Duda G.N., Schell H., Seebeck P., Heller M.O. On the influence of soft tissue coverage in the determination of bone kinematics using skin markers. J Orthop Res 2005, 23(4):726-734.
    • (2005) J Orthop Res , vol.23 , Issue.4 , pp. 726-734
    • Taylor, W.R.1    Ehrig, R.M.2    Duda, G.N.3    Schell, H.4    Seebeck, P.5    Heller, M.O.6
  • 6
    • 0033081306 scopus 로고    scopus 로고
    • Bone position estimation from skin marker co-ordinates using global optimization with joint constraints
    • Lu T.W., O'Connor J.J. Bone position estimation from skin marker co-ordinates using global optimization with joint constraints. J Biochem 1999, 32(2):129-134.
    • (1999) J Biochem , vol.32 , Issue.2 , pp. 129-134
    • Lu, T.W.1    O'Connor, J.J.2
  • 7
    • 57649228441 scopus 로고    scopus 로고
    • Double calibration vs. global optimization: performance and effectiveness for clinical application
    • Stagni R., Fantozzi S., Cappello A. Double calibration vs. global optimization: performance and effectiveness for clinical application. Gait Posture 2009, 29(1):119-122.
    • (2009) Gait Posture , vol.29 , Issue.1 , pp. 119-122
    • Stagni, R.1    Fantozzi, S.2    Cappello, A.3
  • 8
    • 77958196411 scopus 로고    scopus 로고
    • Influence of joint constraints on lower limb kinematics estimation from skin markers using global optimization
    • Duprey S., Cheze L., Dumas R. Influence of joint constraints on lower limb kinematics estimation from skin markers using global optimization. J Biochem 2010, 43(14):2858-2862.
    • (2010) J Biochem , vol.43 , Issue.14 , pp. 2858-2862
    • Duprey, S.1    Cheze, L.2    Dumas, R.3
  • 9
    • 72249116540 scopus 로고    scopus 로고
    • Do kinematic models reduce the effects of soft tissue artefacts in skin marker-based motion analysis? An in vivo study of knee kinematics
    • Andersen M.S., Benoit D.L., Damsgaard M., Ramsey D.K., Rasmussen J. Do kinematic models reduce the effects of soft tissue artefacts in skin marker-based motion analysis? An in vivo study of knee kinematics. J Biochem 2010, 43(2):268-273.
    • (2010) J Biochem , vol.43 , Issue.2 , pp. 268-273
    • Andersen, M.S.1    Benoit, D.L.2    Damsgaard, M.3    Ramsey, D.K.4    Rasmussen, J.5
  • 10
    • 0027836449 scopus 로고
    • Incremental recognition of pedestrians from image sequences
    • Rohr K. Incremental recognition of pedestrians from image sequences. Proc IEEE CVPR 1993, 8-13.
    • (1993) Proc IEEE CVPR , pp. 8-13
    • Rohr, K.1
  • 11
    • 23444453561 scopus 로고    scopus 로고
    • Automated markerless extraction of walking people using deformable contour models
    • Wagg D., Nixon M. Automated markerless extraction of walking people using deformable contour models. Comput Anim Virtual Worlds 1996, 15(3-4):399-406.
    • (1996) Comput Anim Virtual Worlds , vol.15 , Issue.3-4 , pp. 399-406
    • Wagg, D.1    Nixon, M.2
  • 12
    • 0029237904 scopus 로고
    • 3D human body model acquisition from multiple views
    • Kakadiaris I., Metaxes D. 3D human body model acquisition from multiple views. Proc IEEE CVPR 1995, 3:618-623.
    • (1995) Proc IEEE CVPR , vol.3 , pp. 618-623
    • Kakadiaris, I.1    Metaxes, D.2
  • 13
    • 0003378777 scopus 로고    scopus 로고
    • Articulated body motion capture by annealed particle filtering
    • Deutscher J., Blake A., Reid I. Articulated body motion capture by annealed particle filtering. Proc IEEE CVPR 2000, 11:941-944.
    • (2000) Proc IEEE CVPR , vol.11 , pp. 941-944
    • Deutscher, J.1    Blake, A.2    Reid, I.3
  • 14
    • 84887642456 scopus 로고    scopus 로고
    • A marker-free system for the analysis of movement disabilities
    • Legrand L., Marzani F., Dusserre L. A marker-free system for the analysis of movement disabilities. Medinfo 1998, 9(2):1066-1070.
    • (1998) Medinfo , vol.9 , Issue.2 , pp. 1066-1070
    • Legrand, L.1    Marzani, F.2    Dusserre, L.3
  • 15
    • 0042440770 scopus 로고    scopus 로고
    • Shape-from-silhouette of articulated objects and its use for human body kinematics estimation and motion capture
    • IEEE, Madison, WI
    • Cheung G., Baker S., Kanade T. Shape-from-silhouette of articulated objects and its use for human body kinematics estimation and motion capture. IEEE conference on computer vision and pattern recognition 2003, 77-84. IEEE, Madison, WI.
    • (2003) IEEE conference on computer vision and pattern recognition , pp. 77-84
    • Cheung, G.1    Baker, S.2    Kanade, T.3
  • 19
    • 84888291777 scopus 로고    scopus 로고
    • http://research.microsoft.com/pubs/145347/BodyPartRecognition.pdf.
  • 20
    • 84858074442 scopus 로고    scopus 로고
    • Evaluation of the Kinect™ sensor for 3-D kinematic measurement in the workplace
    • Dutta T. Evaluation of the Kinect™ sensor for 3-D kinematic measurement in the workplace. Appl Ergon 2012, 43(4):645-649.
    • (2012) Appl Ergon , vol.43 , Issue.4 , pp. 645-649
    • Dutta, T.1
  • 21
    • 84864334153 scopus 로고    scopus 로고
    • Validity of the Microsoft Kinect for assessment of postural control
    • Clark R.A., Pua Y.H., Fortin K., Ritchie C., Webster K.E., Denehy L., et al. Validity of the Microsoft Kinect for assessment of postural control. Gait Posture 2012, 36(3):372-377.
    • (2012) Gait Posture , vol.36 , Issue.3 , pp. 372-377
    • Clark, R.A.1    Pua, Y.H.2    Fortin, K.3    Ritchie, C.4    Webster, K.E.5    Denehy, L.6
  • 23
    • 0029311073 scopus 로고
    • Position and orientation in space of bones during movement: anatomical frame definition and determination
    • Cappozzo A., Catani F., Croce U.D., Leardini A. Position and orientation in space of bones during movement: anatomical frame definition and determination. Clin Biomech 1995, 10(4):171-178.
    • (1995) Clin Biomech , vol.10 , Issue.4 , pp. 171-178
    • Cappozzo, A.1    Catani, F.2    Croce, U.D.3    Leardini, A.4
  • 24
    • 84888289589 scopus 로고    scopus 로고
    • http://support.xbox.com/kinect/getting-started/home.
  • 25
    • 0036207866 scopus 로고    scopus 로고
    • Standardization and Terminology Committee of the International Society of Biomechanics, ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion - part I: ankle, hip, and spine. International Society of Biomechanics
    • Wu G., Siegler S., Allard P., Kirtley C., Leardini A., Rosenbaum D., et al. Standardization and Terminology Committee of the International Society of Biomechanics, ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion - part I: ankle, hip, and spine. International Society of Biomechanics. J Biochem 2002, 35(4):543-548.
    • (2002) J Biochem , vol.35 , Issue.4 , pp. 543-548
    • Wu, G.1    Siegler, S.2    Allard, P.3    Kirtley, C.4    Leardini, A.5    Rosenbaum, D.6
  • 26
    • 20144387878 scopus 로고    scopus 로고
    • International Society of Biomechanics, ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion - Part II: shoulder, elbow, wrist and hand
    • Wu G., van der Helm F.C., Veeger H.E., Makhsous M., Van Roy P., Anglin C., et al. International Society of Biomechanics, ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion - Part II: shoulder, elbow, wrist and hand. J Biochem 2005, 38(5):981-992.
    • (2005) J Biochem , vol.38 , Issue.5 , pp. 981-992
    • Wu, G.1    van der Helm, F.C.2    Veeger, H.E.3    Makhsous, M.4    Van Roy, P.5    Anglin, C.6
  • 27
    • 34548490524 scopus 로고    scopus 로고
    • Adaptative usage of Butterworth digital filter
    • Erer K.S. Adaptative usage of Butterworth digital filter. J Biomech 2007, 40(30):2934-2943.
    • (2007) J Biomech , vol.40 , Issue.30 , pp. 2934-2943
    • Erer, K.S.1
  • 28
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1(8476):307-310.
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 29
    • 84884977504 scopus 로고    scopus 로고
    • Validity of the Microsoft Kinect for providing lateral trunk lean feedback during gait retraining
    • Clark R.A., Pua Y.H., Bryant A.L., Hunt M.A. Validity of the Microsoft Kinect for providing lateral trunk lean feedback during gait retraining. Gait Posture 2013, May.
    • (2013) Gait Posture
    • Clark, R.A.1    Pua, Y.H.2    Bryant, A.L.3    Hunt, M.A.4
  • 30
    • 33745956269 scopus 로고    scopus 로고
    • Double-step registration of in vivo stereophotogrammetry with both in vitro 6 electrogoniometry and CT medical imaging
    • Sholukha V., Leardini A., Salvia P., Rooze M., Van Sint Jan S. Double-step registration of in vivo stereophotogrammetry with both in vitro 6 electrogoniometry and CT medical imaging. J Biochem 2006, 39(11):2087-2095.
    • (2006) J Biochem , vol.39 , Issue.11 , pp. 2087-2095
    • Sholukha, V.1    Leardini, A.2    Salvia, P.3    Rooze, M.4    Van Sint Jan, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.