메뉴 건너뛰기




Volumn 17, Issue 1, 2015, Pages

Impact of motion correction on reproducibility and spatial variability of quantitative myocardial T2 mapping

Author keywords

Image registration; Motion correction; Myocardial T2 mapping; Quantitative myocardial tissue characterization

Indexed keywords

ACCURACY; ADULT; ARTICLE; BREATH HOLDING; CARDIOVASCULAR MAGNETIC RESONANCE; CLINICAL ARTICLE; CONTROLLED STUDY; ELECTROCARDIOGRAM; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE BASED MOTION CORRECTION; MALE; MYOCARDIAL T2 MAPPING; NUCLEAR MAGNETIC RESONANCE SCANNER; PRIORITY JOURNAL; QUALITATIVE ANALYSIS; RADIOLOGICAL PARAMETERS; STEADY STATE; TISSUE CHARACTERIZATION; ADOLESCENT; ANATOMY AND HISTOLOGY; ARTIFACT; BREATHING; CARDIAC MUSCLE; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; HEART; MIDDLE AGED; MOVEMENT (PHYSIOLOGY); NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PREDICTIVE VALUE; PROCEDURES; REPRODUCIBILITY; YOUNG ADULT;

EID: 84931266773     PISSN: 10976647     EISSN: 1532429X     Source Type: Journal    
DOI: 10.1186/s12968-015-0141-1     Document Type: Article
Times cited : (24)

References (40)
  • 1
    • 0020621027 scopus 로고
    • Nuclear magnetic resonance imaging of acute myocardial infarction in dogs: Alterations in magnetic relaxation times
    • 1:STN:280:DyaL3s3isl2isQ%3D%3D 6858909
    • Higgins CB, Herfkens R, Lipton MJ, Sievers R, Sheldon P, Kaufman L, et al. Nuclear magnetic resonance imaging of acute myocardial infarction in dogs: alterations in magnetic relaxation times. Am J Cardiol. 1983;52(1):184-8.
    • (1983) Am J Cardiol , vol.52 , Issue.1 , pp. 184-188
    • Higgins, C.B.1    Herfkens, R.2    Lipton, M.J.3    Sievers, R.4    Sheldon, P.5    Kaufman, L.6
  • 2
    • 20344406203 scopus 로고    scopus 로고
    • Diagnostic performance of cardiovascular magnetic resonance in patients with suspected acute myocarditis: Comparison of different approaches
    • 15936612
    • Abdel-Aty H, Boye P, Zagrosek A, Wassmuth R, Kumar A, Messroghli D, et al. Diagnostic performance of cardiovascular magnetic resonance in patients with suspected acute myocarditis: comparison of different approaches. J Am Coll Cardiol. 2005;45(11):1815-22.
    • (2005) J Am Coll Cardiol , vol.45 , Issue.11 , pp. 1815-1822
    • Abdel-Aty, H.1    Boye, P.2    Zagrosek, A.3    Wassmuth, R.4    Kumar, A.5    Messroghli, D.6
  • 4
    • 59249091581 scopus 로고    scopus 로고
    • Myocardial edema is a feature of Tako-Tsubo cardiomyopathy and is related to the severity of systolic dysfunction: Insights from T2-weighted cardiovascular magnetic resonance
    • 18086501
    • Abdel-Aty H, Cocker M, Friedrich MG. Myocardial edema is a feature of Tako-Tsubo cardiomyopathy and is related to the severity of systolic dysfunction: insights from T2-weighted cardiovascular magnetic resonance. Int J Cardiol. 2009;132(2):291-3.
    • (2009) Int J Cardiol , vol.132 , Issue.2 , pp. 291-293
    • Abdel-Aty, H.1    Cocker, M.2    Friedrich, M.G.3
  • 5
    • 2542483377 scopus 로고    scopus 로고
    • Delayed enhancement and T2-weighted cardiovascular magnetic resonance imaging differentiate acute from chronic myocardial infarction
    • 15123531
    • Abdel-Aty H, Zagrosek A, Schulz-Menger J, Taylor AJ, Messroghli D, Kumar A, et al. Delayed enhancement and T2-weighted cardiovascular magnetic resonance imaging differentiate acute from chronic myocardial infarction. Circulation. 2004;109(20):2411-6.
    • (2004) Circulation , vol.109 , Issue.20 , pp. 2411-2416
    • Abdel-Aty, H.1    Zagrosek, A.2    Schulz-Menger, J.3    Taylor, A.J.4    Messroghli, D.5    Kumar, A.6
  • 6
    • 77952498118 scopus 로고    scopus 로고
    • Cardiac magnetic resonance with edema imaging identifies myocardium at risk and predicts worse outcome in patients with non-ST-segment elevation acute coronary syndrome
    • 3675879 20510215
    • Raman SV, Simonetti OP, Winner 3rd MW, Dickerson JA, He X, Mazzaferri Jr EL, et al. Cardiac magnetic resonance with edema imaging identifies myocardium at risk and predicts worse outcome in patients with non-ST-segment elevation acute coronary syndrome. J Am Coll Cardiol. 2010;55(22):2480-8.
    • (2010) J Am Coll Cardiol , vol.55 , Issue.22 , pp. 2480-2488
    • Raman, S.V.1    Simonetti, O.P.2    Winner, M.W.3    Dickerson, J.A.4    He, X.5    Mazzaferri, E.L.6
  • 7
    • 53749092380 scopus 로고    scopus 로고
    • Cardiac magnetic resonance with T2-weighted imaging improves detection of patients with acute coronary syndrome in the emergency department
    • 18678772
    • Cury RC, Shash K, Nagurney JT, Rosito G, Shapiro MD, Nomura CH, et al. Cardiac magnetic resonance with T2-weighted imaging improves detection of patients with acute coronary syndrome in the emergency department. Circulation. 2008;118(8):837-44.
    • (2008) Circulation , vol.118 , Issue.8 , pp. 837-844
    • Cury, R.C.1    Shash, K.2    Nagurney, J.T.3    Rosito, G.4    Shapiro, M.D.5    Nomura, C.H.6
  • 8
    • 0029978378 scopus 로고    scopus 로고
    • "Black blood" T2-weighted inversion-recovery MR imaging of the heart
    • 1:STN:280:DyaK283gtFykug%3D%3D 8633172
    • Simonetti OP, Finn JP, White RD, Laub G, Henry DA. "Black blood" T2-weighted inversion-recovery MR imaging of the heart. Radiology. 1996;199(1):49-57.
    • (1996) Radiology , vol.199 , Issue.1 , pp. 49-57
    • Simonetti, O.P.1    Finn, J.P.2    White, R.D.3    Laub, G.4    Henry, D.A.5
  • 9
    • 35248829700 scopus 로고    scopus 로고
    • T2-weighted cardiovascular magnetic resonance imaging
    • 17729358
    • Abdel-Aty H, Simonetti O, Friedrich MG. T2-weighted cardiovascular magnetic resonance imaging. J Magn Reson Imaging. 2007;26(3):452-9.
    • (2007) J Magn Reson Imaging , vol.26 , Issue.3 , pp. 452-459
    • Abdel-Aty, H.1    Simonetti, O.2    Friedrich, M.G.3
  • 10
    • 53749104540 scopus 로고    scopus 로고
    • Using magnetic resonance imaging to characterize recent myocardial injury: Utility in acute coronary syndrome and other clinical scenarios
    • 2764357 18711021
    • Arai AE. Using magnetic resonance imaging to characterize recent myocardial injury: utility in acute coronary syndrome and other clinical scenarios. Circulation. 2008;118(8):795-6.
    • (2008) Circulation , vol.118 , Issue.8 , pp. 795-796
    • Arai, A.E.1
  • 11
    • 0021152307 scopus 로고
    • A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100 MHz: Dependence on tissue type, NMR frequency, temperature, species, excision, and age
    • 1:CAS:528:DyaL2cXlsVOjs70%3D 6482839
    • Bottomley PA, Foster TH, Argersinger RE, Pfeifer LM. A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100 MHz: dependence on tissue type, NMR frequency, temperature, species, excision, and age. Med Phys. 1984;11(4):425-48.
    • (1984) Med Phys , vol.11 , Issue.4 , pp. 425-448
    • Bottomley, P.A.1    Foster, T.H.2    Argersinger, R.E.3    Pfeifer, L.M.4
  • 12
    • 0021952089 scopus 로고
    • Detection and characterization of acute myocardial infarction in man with use of gated magnetic resonance
    • 1:STN:280:DyaL2M7isFamug%3D%3D 3971541
    • McNamara MT, Higgins CB, Schechtmann N, Botvinick E, Lipton MJ, Chatterjee K, et al. Detection and characterization of acute myocardial infarction in man with use of gated magnetic resonance. Circulation. 1985;71(4):717-24.
    • (1985) Circulation , vol.71 , Issue.4 , pp. 717-724
    • McNamara, M.T.1    Higgins, C.B.2    Schechtmann, N.3    Botvinick, E.4    Lipton, M.J.5    Chatterjee, K.6
  • 13
    • 0030612765 scopus 로고    scopus 로고
    • T2 accuracy on a whole-body imager
    • 1:STN:280:DyaK1c%2FitlartQ%3D%3D 9358450
    • Foltz WD, Stainsby JA, Wright GA. T2 accuracy on a whole-body imager. Magn Reson Med. 1997;38(5):759-68.
    • (1997) Magn Reson Med , vol.38 , Issue.5 , pp. 759-768
    • Foltz, W.D.1    Stainsby, J.A.2    Wright, G.A.3
  • 14
    • 33748274368 scopus 로고    scopus 로고
    • Development of a novel optimized breathhold technique for myocardial T2 measurement in thalassemia
    • 16892203
    • He T, Gatehouse PD, Anderson LJ, Tanner M, Keegan J, Pennell DJ, et al. Development of a novel optimized breathhold technique for myocardial T2 measurement in thalassemia. J Magn Reson Imaging. 2006;24(3):580-5.
    • (2006) J Magn Reson Imaging , vol.24 , Issue.3 , pp. 580-585
    • He, T.1    Gatehouse, P.D.2    Anderson, L.J.3    Tanner, M.4    Keegan, J.5    Pennell, D.J.6
  • 16
    • 34248222257 scopus 로고    scopus 로고
    • T2 measurement of the human myocardium using a T2-prepared transient-state TrueFISP sequence
    • 17457877
    • Huang TY, Liu YJ, Stemmer A, Poncelet BP. T2 measurement of the human myocardium using a T2-prepared transient-state TrueFISP sequence. Magn Reson Med. 2007;57(5):960-6.
    • (2007) Magn Reson Med , vol.57 , Issue.5 , pp. 960-966
    • Huang, T.Y.1    Liu, Y.J.2    Stemmer, A.3    Poncelet, B.P.4
  • 18
    • 84867850605 scopus 로고    scopus 로고
    • Myocardial T(2) mapping with respiratory navigator and automatic nonrigid motion correction
    • 22851292
    • Giri S, Shah S, Xue H, Chung YC, Pennell ML, Guehring J, et al. Myocardial T(2) mapping with respiratory navigator and automatic nonrigid motion correction. Magn Reson Med. 2012;68(5):1570-8.
    • (2012) Magn Reson Med , vol.68 , Issue.5 , pp. 1570-1578
    • Giri, S.1    Shah, S.2    Xue, H.3    Chung, Y.C.4    Pennell, M.L.5    Guehring, J.6
  • 19
  • 20
    • 84891503345 scopus 로고    scopus 로고
    • T1-mapping in the heart: Accuracy and precision
    • 3927683 24387626
    • Kellman P, Hansen MS. T1-mapping in the heart: accuracy and precision. J Cardiovasc Magn Reson. 2014;16:2.
    • (2014) J Cardiovasc Magn Reson , vol.16 , pp. 2
    • Kellman, P.1    Hansen, M.S.2
  • 22
    • 34250708986 scopus 로고    scopus 로고
    • Cardiovascular magnetic resonance perfusion imaging at 3-tesla for the detection of coronary artery disease
    • 17599608
    • Cheng ASH, Pegg TJ, Karamitsos TD, Searle N, Jerosch-Herold M, Choudhury RP, et al. Cardiovascular magnetic resonance perfusion imaging at 3-tesla for the detection of coronary artery disease. J Am Coll Cardiol. 2007;49(25):2440-9.
    • (2007) J Am Coll Cardiol , vol.49 , Issue.25 , pp. 2440-2449
    • Cheng, A.S.H.1    Pegg, T.J.2    Karamitsos, T.D.3    Searle, N.4    Jerosch-Herold, M.5    Choudhury, R.P.6
  • 23
    • 84925430992 scopus 로고    scopus 로고
    • Adaptive registration of varying contrast-weighted images for improved tissue characterization (ARCTIC): Application to T1 mapping
    • Roujol S, Foppa M, Weingartner S, Manning WJ, Nezafat R. Adaptive registration of varying contrast-weighted images for improved tissue characterization (ARCTIC): application to T1 mapping. Magn Reson Med. 2015;73(4):1469-82.
    • (2015) Magn Reson Med , vol.73 , Issue.4 , pp. 1469-1482
    • Roujol, S.1    Foppa, M.2    Weingartner, S.3    Manning, W.J.4    Nezafat, R.5
  • 24
    • 84876466117 scopus 로고    scopus 로고
    • Phase-sensitive inversion recovery for myocardial T1 mapping with motion correction and parametric fitting
    • 4138055 22736380
    • Xue H, Greiser A, Zuehlsdorff S, Jolly MP, Guehring J, Arai AE, et al. Phase-sensitive inversion recovery for myocardial T1 mapping with motion correction and parametric fitting. Magn Reson Med. 2013;69(5):1408-20.
    • (2013) Magn Reson Med , vol.69 , Issue.5 , pp. 1408-1420
    • Xue, H.1    Greiser, A.2    Zuehlsdorff, S.3    Jolly, M.P.4    Guehring, J.5    Arai, A.E.6
  • 25
    • 84861231992 scopus 로고    scopus 로고
    • Motion correction for myocardial T1 mapping using image registration with synthetic image estimation
    • 4158317 22135227
    • Xue H, Shah S, Greiser A, Guetter C, Littmann A, Jolly MP, et al. Motion correction for myocardial T1 mapping using image registration with synthetic image estimation. Magn Reson Med. 2012;67(6):1644-55.
    • (2012) Magn Reson Med , vol.67 , Issue.6 , pp. 1644-1655
    • Xue, H.1    Shah, S.2    Greiser, A.3    Guetter, C.4    Littmann, A.5    Jolly, M.P.6
  • 27
    • 0002096460 scopus 로고
    • Adapting optical-flow to measure object motion in reflectance and X-ray image sequences
    • Cornelius N, Kanade T. Adapting optical-flow to measure object motion in reflectance and X-ray image sequences. ACM SIGGRAPH Comput Graph. 1984;18:24-5.
    • (1984) ACM SIGGRAPH Comput Graph , vol.18 , pp. 24-25
    • Cornelius, N.1    Kanade, T.2
  • 28
    • 67049088733 scopus 로고    scopus 로고
    • Cardiovascular magnetic resonance in the diagnosis of acute heart transplant rejection: A review
    • 2660322 19284612
    • Butler CR, Thompson R, Haykowsky M, Toma M, Paterson I. Cardiovascular magnetic resonance in the diagnosis of acute heart transplant rejection: a review. J Cardiovasc Magn Reson. 2009;11:7.
    • (2009) J Cardiovasc Magn Reson , vol.11 , pp. 7
    • Butler, C.R.1    Thompson, R.2    Haykowsky, M.3    Toma, M.4    Paterson, I.5
  • 33
    • 51049092304 scopus 로고    scopus 로고
    • Acceleration and validation of optical flow based deformable registration for image-guided radiotherapy
    • 18661435
    • Ostergaard Noe K, De Senneville BD, Elstrom UV, Tanderup K, Sorensen TS. Acceleration and validation of optical flow based deformable registration for image-guided radiotherapy. Acta Oncol. 2008;47(7):1286-93.
    • (2008) Acta Oncol , vol.47 , Issue.7 , pp. 1286-1293
    • Ostergaard Noe, K.1    De Senneville, B.D.2    Elstrom, U.V.3    Tanderup, K.4    Sorensen, T.S.5
  • 34
    • 77950601928 scopus 로고    scopus 로고
    • Real-time MR-thermometry and dosimetry for interventional guidance on abdominal organs
    • 20373409
    • Roujol S, Ries M, Quesson B, Moonen C, Denis de Senneville B. Real-time MR-thermometry and dosimetry for interventional guidance on abdominal organs. Magn Reson Med. 2010;63(4):1080-7.
    • (2010) Magn Reson Med , vol.63 , Issue.4 , pp. 1080-1087
    • Roujol, S.1    Ries, M.2    Quesson, B.3    Moonen, C.4    Denis De Senneville, B.5
  • 36
    • 0000250265 scopus 로고
    • Measures of the amount of ecologic association between species
    • Dice LR. Measures of the amount of ecologic association between species. Ecology. 1945;26(3):297-302.
    • (1945) Ecology , vol.26 , Issue.3 , pp. 297-302
    • Dice, L.R.1
  • 38
    • 0037377536 scopus 로고    scopus 로고
    • Inferior vena caval hemody- namics quantified in vivo at rest and during cycling exercise using magnetic resonance imaging
    • 1:CAS:528:DC%2BD3sXjtlyltbk%3D 12595296
    • Cheng C, Herfkens R, Taylor C. Inferior vena caval hemody- namics quantified in vivo at rest and during cycling exercise using magnetic resonance imaging. Am J Physiol Heart Circ Physiol. 2003;284(4):H1161-1167.
    • (2003) Am J Physiol Heart Circ Physiol , vol.284 , Issue.4 , pp. 1161-1167
    • Cheng, C.1    Herfkens, R.2    Taylor, C.3
  • 39
    • 84931265999 scopus 로고    scopus 로고
    • High-resolution quantitative 3D T2 mapping allows quantification of changes in edema after myocardial infarction
    • Ding H, Schär M, Zviman M, Halperin HR, Beinart R, Herzka DA. High-resolution quantitative 3D T2 mapping allows quantification of changes in edema after myocardial infarction. J Cardiovasc Magn Reson. 2013;15 Suppl 1:181.
    • (2013) J Cardiovasc Magn Reson , vol.15 , pp. 181
    • Ding, H.1    Schär, M.2    Zviman, M.3    Halperin, H.R.4    Beinart, R.5    Herzka, D.A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.