-
1
-
-
82955195821
-
Benefits of adding fluticasone propionate/salmeterol to tiotropium in moderate to severe COPD
-
22040533
-
Hanania NA, Crater GD, Morris AN, Emmett AH, O'Dell DM, Niewoehner DE. Benefits of adding fluticasone propionate/salmeterol to tiotropium in moderate to severe COPD. Respir Med. 2012;106(1):91-101.
-
(2012)
Respir Med
, vol.106
, Issue.1
, pp. 91-101
-
-
Hanania, N.A.1
Crater, G.D.2
Morris, A.N.3
Emmett, A.H.4
O'Dell, D.M.5
Niewoehner, D.E.6
-
2
-
-
0001071022
-
A comparison of the inspiratory effort required to operate the Diskhaler inhaler and Turbohaler inhaler in the administration of powder drug formulations
-
Sumby B, Cooper S, Smith I. A comparison of the inspiratory effort required to operate the Diskhaler inhaler and Turbohaler inhaler in the administration of powder drug formulations. Br J Clin Res. 1992;3:117-23.
-
(1992)
Br J Clin Res
, vol.3
, pp. 117-123
-
-
Sumby, B.1
Cooper, S.2
Smith, I.3
-
3
-
-
0027222948
-
Deposition patterns of aerosolised drugs within human lungs. Effects of ventilatory parameters
-
8321856 1:CAS:528:DyaK3sXkvVSjtbg%3D
-
Martonen B, Katz IM. Deposition patterns of aerosolised drugs within human lungs. Effects of ventilatory parameters. Pharm Res. 1993;10:871-8.
-
(1993)
Pharm Res
, vol.10
, pp. 871-878
-
-
Martonen, B.1
Katz, I.M.2
-
4
-
-
34248348182
-
The Diskus™: A review of its position among dry powder inhaler devices
-
17504364 1:STN:280:DC%2BD2s3ptlKisw%3D%3D 1974824
-
Chrystyn H. The Diskus™: a review of its position among dry powder inhaler devices. Int J Clin Pract. 2007;61(6):1022-36.
-
(2007)
Int J Clin Pract
, vol.61
, Issue.6
, pp. 1022-1036
-
-
Chrystyn, H.1
-
5
-
-
84857262977
-
The Genuair inhaler: A novel, multi-dose dry powder inhaler
-
22340451 1:CAS:528:DC%2BC38XltV2rs7g%3D
-
Chrystyn H, Niederlaender C. The Genuair inhaler: a novel, multi-dose dry powder inhaler. Int J Clin Pract. 2012;66(3):309-17.
-
(2012)
Int J Clin Pract
, vol.66
, Issue.3
, pp. 309-317
-
-
Chrystyn, H.1
Niederlaender, C.2
-
6
-
-
0011489418
-
Dispersion and characterization of pharmaceutical dry powder aerosols
-
Dunbar CA, Hickey AJ, Holder P. Dispersion and characterization of pharmaceutical dry powder aerosols. KONA Powder Part. 1998;16:45.
-
(1998)
KONA Powder Part
, vol.16
, pp. 45
-
-
Dunbar, C.A.1
Hickey, A.J.2
Holder, P.3
-
7
-
-
0030200977
-
The influence of formulation on emission, deaggregation and deposition of dry powders for inhalation
-
1:CAS:528:DyaK28Xks1entbc%3D
-
French DL, Edwards DA, Niven RW. The influence of formulation on emission, deaggregation and deposition of dry powders for inhalation. J Aerosol Sci. 1996;27:769-83.
-
(1996)
J Aerosol Sci
, vol.27
, pp. 769-783
-
-
French, D.L.1
Edwards, D.A.2
Niven, R.W.3
-
8
-
-
0037032434
-
Deagglomeration of dry powder pharmaceutical aerosols
-
12429458 1:CAS:528:DC%2BD38XosFags7g%3D
-
Voss A, Finlay WA. Deagglomeration of dry powder pharmaceutical aerosols. Int J Pharm. 2002;248(1-2):39-50.
-
(2002)
Int J Pharm
, vol.248
, Issue.1-2
, pp. 39-50
-
-
Voss, A.1
Finlay, W.A.2
-
9
-
-
0034933441
-
Ex-vivo product performance of Diskus™ and Turbuhaler inhalers using inhalation profiles from patients with severe chronic obstructive pulmonary disease
-
11392571 1:STN:280:DC%2BD38%2FhtFeksw%3D%3D
-
Burnell PK, Small T, Doig S, Johal B, Jenkins R, Gibson GJ. Ex-vivo product performance of Diskus™ and Turbuhaler inhalers using inhalation profiles from patients with severe chronic obstructive pulmonary disease. Respir Med. 2001;95(5):324-30.
-
(2001)
Respir Med
, vol.95
, Issue.5
, pp. 324-330
-
-
Burnell, P.K.1
Small, T.2
Doig, S.3
Johal, B.4
Jenkins, R.5
Gibson, G.J.6
-
10
-
-
0030707638
-
General factors influencing drug delivery to the lung
-
9474361
-
Ganderton D. General factors influencing drug delivery to the lung. Respir Med. 1997;91:13.
-
(1997)
Respir Med
, vol.91
, pp. 13
-
-
Ganderton, D.1
-
11
-
-
0033910480
-
In vitro comparison of three salbutamol-containing multidose dry powder inhalers
-
1:CAS:528:DC%2BD3cXlvVyhsrY%3D
-
Palander A. In vitro comparison of three salbutamol-containing multidose dry powder inhalers. Clin Drug Invest. 2000;20:25-33.
-
(2000)
Clin Drug Invest
, vol.20
, pp. 25-33
-
-
Palander, A.1
-
12
-
-
84878592879
-
Asthma medication delivery: Mists and myths
-
23522986
-
Rottier BL, Rubin BK. Asthma medication delivery: mists and myths. Paediatr Respir Rev. 2013;14(2):112-8.
-
(2013)
Paediatr Respir Rev
, vol.14
, Issue.2
, pp. 112-118
-
-
Rottier, B.L.1
Rubin, B.K.2
-
13
-
-
84895922767
-
Development and comparison of new high-efficiency dry powder inhalers for carrier-free formulations
-
Behara SR, Longest PW, Farkas DR, Hindle M. Development and comparison of new high-efficiency dry powder inhalers for carrier-free formulations. J Pharm Sci. 2014;103(2):465-77.
-
(2014)
J Pharm Sci.
, vol.103
, Issue.2
, pp. 465-477
-
-
Behara, S.R.1
Longest, P.W.2
Farkas, D.R.3
Hindle, M.4
-
14
-
-
8644222142
-
Inhalation technique and variables associated with misuse of conventional metered-dose inhalers and newer dry powder inhalers in experienced adults
-
15562882
-
Melani AS, Zanchetta D, Barbato N, Sestini P, Cinti C, Canessa PA, et al. Inhalation technique and variables associated with misuse of conventional metered-dose inhalers and newer dry powder inhalers in experienced adults. Ann Allergy Asthma Immunol. 2004;93(5):439-46.
-
(2004)
Ann Allergy Asthma Immunol
, vol.93
, Issue.5
, pp. 439-446
-
-
Melani, A.S.1
Zanchetta, D.2
Barbato, N.3
Sestini, P.4
Cinti, C.5
Canessa, P.A.6
-
15
-
-
84878405695
-
Prevalence and COPD phenotype for a suboptimal peak inspiratory flow rate against the simulated resistance of the Diskus® dry powder inhaler
-
23025451 1:CAS:528:DC%2BC3sXotlens7s%3D
-
Mahler DA, Waterman LA, Gifford AH. Prevalence and COPD phenotype for a suboptimal peak inspiratory flow rate against the simulated resistance of the Diskus® dry powder inhaler. J Aerosol Med Pulm Drug Deliv. 2013;26(3):174-9.
-
(2013)
J Aerosol Med Pulm Drug Deliv
, vol.26
, Issue.3
, pp. 174-179
-
-
Mahler, D.A.1
Waterman, L.A.2
Gifford, A.H.3
-
16
-
-
84881488202
-
A method of predicting inspiratory flow rate and volume from an inhaler using acoustic measurements
-
23892977
-
Holmes M, Seheult J, Geraghty C, D'Arcy S, O'Brien U, Crispino O'Connell G, et al. A method of predicting inspiratory flow rate and volume from an inhaler using acoustic measurements. Physiol Meas. 2013;34:903-14.
-
(2013)
Physiol Meas
, vol.34
, pp. 903-914
-
-
Holmes, M.1
Seheult, J.2
Geraghty, C.3
D'Arcy, S.4
O'Brien, U.5
Crispino O'Connell, G.6
-
17
-
-
0028889728
-
The Diskus™: A new multi-dose powder device -efficacy and comparison with Turbuhaler™
-
Fuller R. The Diskus™: a new multi-dose powder device -efficacy and comparison with Turbuhaler™. J Aerosol Med. 1995;8(2):11-7.
-
(1995)
J Aerosol Med
, vol.8
, Issue.2
, pp. 11-17
-
-
Fuller, R.1
-
18
-
-
84897037895
-
Comparison of dry powder versus nebulized beta-agonist in patients with COPD who have suboptimal peak inspiratory flow rate
-
Mahler DA, Waterman LA, Ward J, Gifford AH. Comparison of dry powder versus nebulized beta-agonist in patients with COPD who have suboptimal peak inspiratory flow rate. J Aerosol Med Pulm Drug Deliv. 2014;27(2):103-9.
-
(2014)
J Aerosol Med Pulm Drug Deliv
, vol.27
, Issue.2
, pp. 103-109
-
-
Mahler, D.A.1
Waterman, L.A.2
Ward, J.3
Gifford, A.H.4
-
19
-
-
84939913479
-
-
United States Pharmacopeial Convention (USP): Chapter 601 USP36-NF31. Rockville, MD: USP
-
United States Pharmacopeial Convention (USP): Chapter 601: Aerosols, metered-dose inhalers, and dry powder inhalers. In: USP36-NF31. Rockville, MD: USP; 2013;242-262
-
(2013)
Aerosols, Metered-dose Inhalers, and Dry Powder Inhalers
, pp. 242-262
-
-
-
20
-
-
84866737926
-
Characterisation of high dose aerosols from dry powder inhalers
-
22939966 1:CAS:528:DC%2BC38XhtlSlsrvM
-
Grasmeijer F, Hagedoorn P, Frijlink HW, de Boer AH. Characterisation of high dose aerosols from dry powder inhalers. Int J Pharm. 2012;437(1-2):242-9.
-
(2012)
Int J Pharm
, vol.437
, Issue.1-2
, pp. 242-249
-
-
Grasmeijer, F.1
Hagedoorn, P.2
Frijlink, H.W.3
De Boer, A.H.4
-
21
-
-
58549083959
-
Introduction of the electrical Next Generation Impactor (eNGI) and investigation of its capabilities for the study of pressurized metered dose inhalers
-
19015961 1:CAS:528:DC%2BD1cXhtlyjtLzI
-
Hoe S, Young PM, Chan H-K, Traini D. Introduction of the electrical Next Generation Impactor (eNGI) and investigation of its capabilities for the study of pressurized metered dose inhalers. Pharm Res. 2009;26:431-7.
-
(2009)
Pharm Res
, vol.26
, pp. 431-437
-
-
Hoe, S.1
Young, P.M.2
Chan, H.-K.3
Traini, D.4
-
23
-
-
84864679195
-
-
ternational Organization for Standardization. ISO 27427 Geneva: International Standards Organization
-
International Organization for Standardization. ISO 27427. Anaesthetic and respiratory equipment - nebulizing systems and components. Geneva: International Standards Organization; 2010.
-
(2010)
Anaesthetic and Respiratory Equipment - Nebulizing Systems and Components
-
-
-
25
-
-
0036305146
-
Pharmacokinetics and relative bioavailability of salbutamol metered-dose inhaler in healthy volunteers
-
12100764 1:CAS:528:DC%2BD38Xlt1aitrY%3D
-
Du XL, Zhu Z, Fu Q, Li DK, Xu WB. Pharmacokinetics and relative bioavailability of salbutamol metered-dose inhaler in healthy volunteers. Acta Pharmacol Sin. 2002;23(7):663-6.
-
(2002)
Acta Pharmacol Sin
, vol.23
, Issue.7
, pp. 663-666
-
-
Du, X.L.1
Zhu, Z.2
Fu, Q.3
Li, D.K.4
Xu, W.B.5
-
26
-
-
0002669964
-
Mechanisms of aerosol deposition and clearance
-
Moren F, Newhouse MT, Dolovich MB, editors 2nd edn. New York: Elsevier Science Publishers (Biomedical Division
-
Brain JD. Mechanisms of aerosol deposition and clearance. In: Moren F, Newhouse MT, Dolovich MB, editors. Aerosols in medicine. Principles, diagnosis and therapy, 2nd edn. New York: Elsevier Science Publishers (Biomedical Division); 1993. p. 351-74.
-
(1993)
Aerosols in Medicine. Principles, Diagnosis and Therapy
, pp. 351-374
-
-
Brain, J.D.1
-
27
-
-
11144256553
-
Finding the lung sound-flow relationship in normal and asthmatic subjects. in proceeding of Engineering in Medicine and Biology Society, 2004. IEMBS '04. 26th Annual International Conference of the IEEE, Volume: 2, 1-5
-
September 2004. Sacramento, CA, USA
-
Hossain I, Moussavi Z. Finding the lung sound-flow relationship in normal and asthmatic subjects. In proceeding of Engineering in Medicine and Biology Society, 2004. IEMBS '04. 26th Annual International Conference of the IEEE, Volume: 2, 1-5 September 2004. Sacramento, CA, USA. Conf Proc IEEE Eng Med Biol Soc. 2004;5:3852-5.
-
(2004)
Conf Proc IEEE Eng Med Biol Soc
, vol.5
, pp. 3852-3855
-
-
Hossain, I.1
Moussavi, Z.2
-
28
-
-
0033072264
-
Assessing lung deposition of inhaled medications. Consensus statement from a workshop of the British Association for Lung Research, held at the Institute of Biology
-
London, U.K. on 17 April 1998. Snell NJC, Ganderton D, eds Respir Med. 2000 Sep;94(9):918-9
-
Edwards AM. Assessing lung deposition of inhaled medications. Consensus statement from a workshop of the British Association for Lung Research, held at the Institute of Biology, London, U.K. on 17 April 1998. Snell NJC, Ganderton D, eds. Respir Med 1999;93:123-33. Respir Med. 2000 Sep;94(9):918-9.
-
(1999)
Respir Med
, vol.93
, pp. 123-133
-
-
Edwards, A.M.1
|