Volumn 223, Issue 6, 2009, Pages 697-711

Design and simulation of a poly(vinyl alcohol)-bacterial cellulose nanocomposite mechanical aortic heart valve prosthesis

Author keywords

Anisotropy; Bacterial cellulose; Finite element method; Mechanical heart valves; Non linearity; Poly(vinyl alcohol); Soft tissue

Indexed keywords

AORTIC HEART VALVES; ARTICULAR CARTILAGES; BACTERIAL CELLULOSE; DESIGN AND SIMULATION; GALERKIN; HEART VALVES; HYPER ELASTIC; MECHANICAL BEHAVIOUR; MECHANICAL HEART VALVES; MECHANICAL MODEL; NON-LINEAR; NON-LINEARITY; NONLINEAR FINITE ELEMENT METHOD; PHYSIOLOGICAL CONDITION; PRINCIPAL DIRECTIONS; SOFT TISSUE; SURFACING TECHNIQUES; BACTERIAL CELLULOSE NANOCOMPOSITES; POLY (VINYL ALCOHOL) (PVA);

EID: 84930406393     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544119JEIM493     Document Type: Article
Times cited : (62)

References (29)
  • 1
    • 0030269992 scopus 로고    scopus 로고
    • New polyurethane heart valve prosthesis: Design, manufacture and evaluation
    • Mackay, T. G., Wheatley, D. J., Bernacca, G. M., Fisher, A. C., and Hindle, C. S. New polyurethane heart valve prosthesis: design, manufacture and evaluation. Biomaterials, 1996, 17, 1857-1863.
    • (1996) Biomaterials , vol.17 , pp. 1857-1863
    • MacKay, T.G.1    Wheatley, D.J.2    Bernacca, G.M.3    Fisher, A.C.4    Hindle, C.S.5
  • 3
    • 0026741326 scopus 로고
    • CAD design stress analysis and in vitro evaluation of three leaflet blood-pump valves
    • Knierbin, B., Rosarius, N., Unger, A., Reul, H., and Rau, G. CAD design, stress analysis and in vitro evaluation of three leaflet blood-pump valves. J. Biomed. Engng, 1992, 14, 275-286.
    • (1992) J. Biomed. Engng , vol.14 , pp. 275-286
    • Knierbin, B.1    Rosarius, N.2    Unger, A.3    Reul, H.4    Rau, G.5
  • 4
    • 0025150278 scopus 로고
    • Development of a new inflow valve for a 20 cc semisoft ventricle: Preliminary results
    • Wijsmuller, E. G., Yu, L. S., Yuan, B., Bishop, N. D., and Kolff, W. J. Development of a new inflow valve for a 20 cc semisoft ventricle: preliminary results. Int. J. Artif. Organs, 1990, 13, 503-508.
    • (1990) Int. J. Artif. Organs , vol.13 , pp. 503-508
    • Wijsmuller, E.G.1    Yu, L.S.2    Yuan, B.3    Bishop, N.D.4    Kolff, W.J.5
  • 5
    • 58149308250 scopus 로고    scopus 로고
    • A finite element model on effects of impact load and cavitation on fatigue crack propagation in mechanical bileaflet aortic heart valve
    • DOI: 10.1243/09544119JEIM432
    • Mohammadi, H., Klassen, R. J., and Wan, W. K. A finite element model on effects of impact load and cavitation on fatigue crack propagation in mechanical bileaflet aortic heart valve. Proc. IMechE, Part H: J. Engineering in Medicine, 2008, 222(7), 1115-1125. DOI: 10.1243/09544119JEIM432.
    • (2008) Proc. i Mech e Part H: J. Engineering in Medicine , vol.222 , Issue.7 , pp. 1115-1125
    • Mohammadi, H.1    Klassen, R.J.2    Wan, W.K.3
  • 7
    • 0027642707 scopus 로고
    • Numerical simulation of leaflet flexure in bioprosthetic valve mounted on rigid and expansible sterns
    • Krucinski, S., Vesely, I., and Dokanish, M. A. Numerical simulation of leaflet flexure in biopros-thetic valve mounted on rigid and expansible sterns. J. Biomech., 1993, 26, 929-943.
    • (1993) J. Biomech. , vol.26 , pp. 929-943
    • Krucinski, S.1    Vesely, I.2    Dokanish, M.A.3
  • 8
    • 0030152088 scopus 로고    scopus 로고
    • A comparative study of linear and nonlinear simulations of the leaflets in a bioprosthetic heart valve during the cardiac cycle
    • Patterson, E. A., Howard, I. C., and Thornton, M. A. A comparative study of linear and nonlinear simulations of the leaflets in a bioprosthetic heart valve during the cardiac cycle. J. Med. Engng Technol., 1996, 20, 95-108.
    • (1996) J. Med. Engng Technol. , vol.20 , pp. 95-108
    • Patterson, E.A.1    Howard, I.C.2    Thornton, M.A.3
  • 9
    • 0034990044 scopus 로고    scopus 로고
    • Finite element analysis of aortic heart valve sparing: Influence of graft shape and stiffness
    • Grande, K. J., Cochran, R. P., and Reinhall, P. G. Finite element analysis of aortic heart valve sparing: influence of graft shape and stiffness. IEEE Trans. Biomed. Engng, 2001, 48, 647-654.
    • (2001) IEEE Trans. Biomed. Engng , vol.48 , pp. 647-654
    • Grande, K.J.1    Cochran, R.P.2    Reinhall, P.G.3
  • 10
    • 0035138435 scopus 로고    scopus 로고
    • Stress analysis of the aortic valve with and without sinuses of valvular
    • Beck, A., Thubrikar, M. J., and Robicsek, F. Stress analysis of the aortic valve with and without sinuses of valvular. J. Heart Valve Dis., 2001, 10, 1-11.
    • (2001) J. Heart Valve Dis. , vol.10 , pp. 1-11
    • Beck, A.1    Thubrikar, M.J.2    Robicsek, F.3
  • 11
    • 31144473685 scopus 로고    scopus 로고
    • Time-dependent analysis of leaflets in mechanical aortic bileaflet valve in closing phase using the finite strip method
    • Mohammadi, H., Ahmadian, M. T., and Wan, W. K. Time-dependent analysis of leaflets in mechanical aortic bileaflet valve in closing phase using the finite strip method. J. Med. Engng Phys., 2006, 28, 122-133.
    • (2006) J. Med. Engng Phys. , vol.28 , pp. 122-133
    • Mohammadi, H.1    Ahmadian, M.T.2    Wan, W.K.3
  • 12
    • 0020554717 scopus 로고
    • Elastic and viscoplastic material behaviour of fresh and glutaraldehyde-treated porcine aortic valve tissue
    • Rousseau, E. P. M., Sauren, A. A. H. J., and Hout, M. C. V. Elastic and viscoplastic material behaviour of fresh and glutaraldehyde-treated porcine aortic valve tissue. J. Biomech., 1983, 16, 339-348.
    • (1983) J. Biomech. , vol.16 , pp. 339-348
    • Rousseau, E.P.M.1    Sauren, A.A.H.J.2    Hout, M.C.V.3
  • 13
    • 1442275667 scopus 로고    scopus 로고
    • Further insights into normal aortic heart valve functions; Rule of compliant aortic root on leaflet opening and valve orifice area
    • Sripathi, V. C., Kumar, R. K., and Balakrishnam, K. R. Further insights into normal aortic heart valve functions; rule of compliant aortic root on leaflet opening and valve orifice area. Ann. Thoracic Surg., 2004, 77, 844-851.
    • (2004) Ann. Thoracic Surg. , vol.77 , pp. 844-851
    • Sripathi, V.C.1    Kumar, R.K.2    Balakrishnam, K.R.3
  • 14
    • 0017624352 scopus 로고    scopus 로고
    • The stress/strain and fatigue behaviour of glutar-aldehyde preserved heart valve tissue
    • Burriesci, G., Haward, I. C., and Patterson, E. A. The stress/strain and fatigue behaviour of glutar-aldehyde preserved heart valve tissue. J. Biomech., 1999, 10, 707-724.
    • (1999) J. Biomech. , vol.10 , pp. 707-724
    • Burriesci, G.1    Haward, I.C.2    Patterson, E.A.3
  • 15
    • 0034885699 scopus 로고    scopus 로고
    • A nonlinear anisotropic model for porcine heart valves
    • Li, J., Lou, X. Y., and Kuang, Z. B. A nonlinear anisotropic model for porcine heart valves. J. Biomech., 2001, 34, 1279-1289.
    • (2001) J. Biomech. , vol.34 , pp. 1279-1289
    • Li, J.1    Lou, X.Y.2    Kuang, Z.B.3
  • 16
    • 0142200802 scopus 로고    scopus 로고
    • Geometrical stress reduction factors in anisotropic porcine heart valves
    • Luo, X. Y., Li, W. G., and Li, J. Geometrical stress reduction factors in anisotropic porcine heart valves. Trans. ASME, J. Biomech. Engng, 2003, 125, 735-744.
    • (2003) Trans. ASME J. Biomech. Engng , vol.125 , pp. 735-744
    • Luo, X.Y.1    Li, W.G.2    Li, J.3
  • 17
    • 0742269712 scopus 로고    scopus 로고
    • Collagen fibers reduce stresses and stabilize motion of aortic valve leaflets during systole
    • De Hart, J., Peters, G. W. M., Schreurs, P. G. J., and Baaijens, F. P. T. Collagen fibers reduce stresses and stabilize motion of aortic valve leaflets during systole. J. Biomech., 2004, 37, 303-311.
    • (2004) J. Biomech. , vol.37 , pp. 303-311
    • De Hart, J.1    Peters, G.W.M.2    Schreurs, P.G.J.3    Baaijens, F.P.T.4
  • 20
    • 33750436937 scopus 로고    scopus 로고
    • The polyvinyl alcohol - Bacterial cellulose as a new nanocomposite for biomedical applications
    • Millon, L. E. and Wan, W. K. The polyvinyl alcohol - bacterial cellulose as a new nanocomposite for biomedical applications. J. Biomed. Mater. Res. B; Appl. Biomater., 2006, 79, 245-253.
    • (2006) J. Biomed. Mater. Res. B; Appl. Biomater. , vol.79 , pp. 245-253
    • Millon, L.E.1    Wan, W.K.2
  • 21
    • 22444450379 scopus 로고    scopus 로고
    • Measurement of the elastic modulus of single bacterial cellulose fibers using atomic force microscopy
    • Guhados, G., Wan, W. K., and Hutter, J. Measurement of the elastic modulus of single bacterial cellulose fibers using atomic force microscopy. Langmuir, 2005, 21, 6642-6646.
    • (2005) Langmuir , vol.21 , pp. 6642-6646
    • Guhados, G.1    Wan, W.K.2    Hutter, J.3
  • 22
    • 70349343323 scopus 로고    scopus 로고
    • And manufacturing of polyvinyl alcohol cryogel tri-leaflet heart valve prosthesis
    • Jiang, H., Campbell, G., Boughner, D., Wan, W. K., and Quantz, M. Design and manufacturing of polyvinyl alcohol cryogel tri-leaflet heart valve prosthesis. J. Med. Engng Phys., 2003, 24, 267-277.
    • (2003) J. Med. Engng Phys. , vol.24 , pp. 267-277
    • Jiang, H.1    Campbell, G.2    Boughner, D.3    Wan, W.K.4    Design, Q.M.5
  • 23
    • 0028533820 scopus 로고
    • A synthetic leaflet heart valve with improved opening characteristics
    • Leat, M. E. and Fisher, J. A synthetic leaflet heart valve with improved opening characteristics. Med. Engng Phys., 1994, 16, 470-476.
    • (1994) Med. Engng Phys. , vol.16 , pp. 470-476
    • Leat, M.E.1    Fisher, J.2
  • 26
    • 0028024747 scopus 로고
    • Hydrodynamic performance of the Medtronic Freestyle aortic root bioprosthesis
    • Yoganathan, A. P., Eberhardt, C., and Walker, P. G. Hydrodynamic performance of the Medtronic Freestyle aortic root bioprosthesis. J. Heart Valve Dis., 1994, 3, 571-580.
    • (1994) J. Heart Valve Dis. , vol.3 , pp. 571-580
    • Yoganathan, A.P.1    Eberhardt, C.2    Walker, P.G.3
  • 28
    • 0034793868 scopus 로고    scopus 로고
    • Mechanisms of mechanical heart valve cavitation: Investigation using a tilting disk valve model
    • He, Z., Xi, B., Zhu, K., and Hwang, N. H. C. Mechanisms of mechanical heart valve cavitation: investigation using a tilting disk valve model. J. Heart Valve Dis., 2001, 10, 666-674.
    • (2001) J. Heart Valve Dis. , vol.10 , pp. 666-674
    • He, Z.1    Xi, B.2    Zhu, K.3    Hwang, N.H.C.4