메뉴 건너뛰기




Volumn 20, Issue 3, 1996, Pages 95-108

A comparative study of linear and nonlinear simulations of the leaflets in a bioprosthetic heart valve during the cardiac cycle

Author keywords

[No Author keywords available]

Indexed keywords

BOUNDARY CONDITIONS; CODES (SYMBOLS); COMPUTATIONAL GEOMETRY; COMPUTER SIMULATION; FINITE ELEMENT METHOD; MATHEMATICAL MODELS; PRESSURE; STRESSES; TENSILE PROPERTIES;

EID: 0030152088     PISSN: 03091902     EISSN: None     Source Type: Journal    
DOI: 10.3109/03091909609008387     Document Type: Article
Times cited : (50)

References (22)
  • 2
    • 0027642707 scopus 로고
    • Numerical simulation of leaflet flexure in bioprosthetic valves mounted on rigid and expansile stents
    • KRUCINSKI, S., VESELY, J., DOKAINISH, M. A. and CAMPBELL, G. (1993) Numerical simulation of leaflet flexure in bioprosthetic valves mounted on rigid and expansile stents. Journal of Biomechanics, 26, 929-943.
    • (1993) Journal of Biomechanics , vol.26 , pp. 929-943
    • Krucinski, S.1    Vesely, J.2    Dokainish, M.A.3    Campbell, G.4
  • 3
    • 0025113785 scopus 로고
    • A two-dimensional finite element analysis of a bioprosthetic heart valve
    • HUANG, X., BLACK, M. M., HOWARD, I. C. and PATTERSON, E. A. (1990) A two-dimensional finite element analysis of a bioprosthetic heart valve. Journal of Biomechanics, 23, 753-762.
    • (1990) Journal of Biomechanics , vol.23 , pp. 753-762
    • Huang, X.1    Black, M.M.2    Howard, I.C.3    Patterson, E.A.4
  • 4
    • 0017328807 scopus 로고
    • Stress analysis of aortic valve leaflets with smoothed geometric data
    • CATALOGLU, A., CLARK, R. E. and GOULD, P. L. (1977) Stress analysis of aortic valve leaflets with smoothed geometric data. Journal of Biomechanics, 10, 153-8.
    • (1977) Journal of Biomechanics , vol.10 , pp. 153-158
    • Cataloglu, A.1    Clark, R.E.2    Gould, P.L.3
  • 5
    • 0002956488 scopus 로고
    • A non-linear finite element stress analysis of bioprosthetic heart valves
    • K. H. Gallagher, B. R. Simon, P. C. Johnson and J. F. Gross, (eds) Wiley, Chichester
    • CHRISTIE, G. W. and MEDLAND, I. C. (1982) A non-linear finite element stress analysis of bioprosthetic heart valves. In K. H. Gallagher, B. R. Simon, P. C. Johnson and J. F. Gross, (eds) Finite Elements in Biomechanics (Wiley, Chichester), 153-179.
    • (1982) Finite Elements in Biomechanics , pp. 153-179
    • Christie, G.W.1    Medland, I.C.2
  • 6
    • 0022929725 scopus 로고
    • Influence of stent height upon stresses on the cusps of closed bioprosthetic valves
    • SABBAH, H. N., HAMID, M. S. and STEIN, P. D. (1986) Influence of stent height upon stresses on the cusps of closed bioprosthetic valves. Journal of Biomechanics, 19, 759-769.
    • (1986) Journal of Biomechanics , vol.19 , pp. 759-769
    • Sabbah, H.N.1    Hamid, M.S.2    Stein, P.D.3
  • 7
    • 0026329244 scopus 로고
    • On stress reduction in bioprosthetic heart valve leaflets by the use of a flexible stem
    • CHRISTIE, G. W. and BARRATT-BOYES, B. G. (1991) On stress reduction in bioprosthetic heart valve leaflets by the use of a flexible stem. Journal of Cardiovascular Surgery, 6, 476-481.
    • (1991) Journal of Cardiovascular Surgery , vol.6 , pp. 476-481
    • Christie, G.W.1    Barratt-Boyes, B.G.2
  • 9
    • 0026741326 scopus 로고
    • CAD-design, stress analysis and in vitro evaluation of three leaflet blood-pump valves
    • KNIERBEIN, B., ROSARIUS, N., UNGER, A., REUL, H. and RAU, G. (1992) CAD-design, stress analysis and in vitro evaluation of three leaflet blood-pump valves. Journal of Biomedical Engineering, 14, 275-285.
    • (1992) Journal of Biomedical Engineering , vol.14 , pp. 275-285
    • Knierbein, B.1    Rosarius, N.2    Unger, A.3    Reul, H.4    Rau, G.5
  • 10
    • 0023755406 scopus 로고
    • Tissue buckling as a mechanism of bioprosthetic valve failure
    • VESELEY, I., BOUGHNER, D. and SONG, T. (1988) Tissue buckling as a mechanism of bioprosthetic valve failure. Annals of Thoracic Surgery, 46, 302-308.
    • (1988) Annals of Thoracic Surgery , vol.46 , pp. 302-308
    • Veseley, I.1    Boughner, D.2    Song, T.3
  • 11
    • 0018101376 scopus 로고
    • Fatigue induced damage in glutaraldehyde-preserved heart valve tissue
    • BROOM, N. D. (1978) Fatigue induced damage in glutaraldehyde-preserved heart valve tissue. Journal of Thoracic and Cardiovascular Surgery, 76, 202-211.
    • (1978) Journal of Thoracic and Cardiovascular Surgery , vol.76 , pp. 202-211
    • Broom, N.D.1
  • 12
    • 9544249545 scopus 로고    scopus 로고
    • Three-dimensional stress analysis of polypropylene leaflets for prosthetic heart valves
    • in press
    • THORNTON, M. A., HOWARD, I. C. and PATTERSON, E. A. (1996) Three-dimensional stress analysis of polypropylene leaflets for prosthetic heart valves. Medical Engineering and Physics (in press).
    • (1996) Medical Engineering and Physics
    • Thornton, M.A.1    Howard, I.C.2    Patterson, E.A.3
  • 14
  • 16
    • 0013679648 scopus 로고
    • The Sheffield bicuspid valve: Concept, design and in vitro and in vivo assessment, in Biologic Bioprosthetic Valves
    • edited by E. Bodner and M. Yacomb, 1986, Yorke Medical, New York
    • BLACK, M. M., DRURY, P. J., TINDALE, W. B. and LAWFORD, P. Y. (1986) The Sheffield bicuspid valve: concept, design and in vitro and in vivo assessment, in Biologic Bioprosthetic Valves, edited by E. Bodner and M. Yacomb, Proc. 3rd. Int. Symp., (1986), Yorke Medical, New York, 709-711.
    • (1986) Proc. 3rd. Int. Symp. , pp. 709-711
    • Black, M.M.1    Drury, P.J.2    Tindale, W.B.3    Lawford, P.Y.4
  • 18
    • 0021787582 scopus 로고
    • The mechanical response of glutaraldehyde-fixed bovine pericardium to uniaxial load
    • TROWBRIDGE, E. A., BLACK, M. M. and DANIEL, C. L. (1985) The mechanical response of glutaraldehyde-fixed bovine pericardium to uniaxial load, Journal of Materials Science, 20, 114-140.
    • (1985) Journal of Materials Science , vol.20 , pp. 114-140
    • Trowbridge, E.A.1    Black, M.M.2    Daniel, C.L.3
  • 19
    • 0022639085 scopus 로고
    • Pericardial heterografts: Towards quality control of the mechanical properties of glutaraldhyde fixed leaflets
    • TROWBRIDGE, E. A., ROBERTS, K. M., CROFTS, C. F. and LAWFORD, P. V. (1986) Pericardial heterografts: towards quality control of the mechanical properties of glutaraldhyde fixed leaflets, Journal of Thoracic Cardiovascular Surgery, 92, 21-28.
    • (1986) Journal of Thoracic Cardiovascular Surgery , vol.92 , pp. 21-28
    • Trowbridge, E.A.1    Roberts, K.M.2    Crofts, C.F.3    Lawford, P.V.4
  • 20
    • 0023964378 scopus 로고
    • The tensile strength of natural and chemically modified bovine pericardium
    • CROFTS, C. E. and TROWBRIDGE, E. A. (1988) The tensile strength of natural and chemically modified bovine pericardium, Journal of Biomedical Material Research, 22, 89-98.
    • (1988) Journal of Biomedical Material Research , vol.22 , pp. 89-98
    • Crofts, C.E.1    Trowbridge, E.A.2
  • 22
    • 0020080193 scopus 로고
    • A study of the effects of glutaraldehyde and formaldehyde on the mechanical behaviour of bovine pericardium
    • VAN NOORT, R., YATES, S. P., MARTIN, T. R. P., BARKER, A. T. and BLACK, M. M. (1982) A study of the effects of glutaraldehyde and formaldehyde on the mechanical behaviour of bovine pericardium, Biomaterials, 3, 21-26.
    • (1982) Biomaterials , vol.3 , pp. 21-26
    • Van Noort, R.1    Yates, S.P.2    Martin, T.R.P.3    Barker, A.T.4    Black, M.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.