메뉴 건너뛰기




Volumn 12, Issue 6, 2015, Pages 1227-1232

Extraction of Select Secure leads compared to conventional pacing leads in patients with congenital heart disease and congenital atrioventricular block

Author keywords

Congenital heart block; Congenital heart disease; Lead extraction; Pacemaker; Pediatrics; Select Secure pacing lead

Indexed keywords

ADULT; ARTICLE; ARTIFICIAL HEART PACEMAKER; ARTIFICIAL HEART PACEMAKER FAILURE; ATRIOVENTRICULAR BLOCK; CHILD; CONGENITAL HEART BLOCK; CONGENITAL HEART DISEASE; EXTRACTION; FEMALE; HEART PACING; HUMAN; MAJOR CLINICAL STUDY; MALE; MULTIVARIATE LOGISTIC REGRESSION ANALYSIS; PERICARDIAL EFFUSION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; TRANSTHORACIC ECHOCARDIOGRAPHY; ADOLESCENT; ADVERSE EFFECTS; COMPARATIVE STUDY; DEVICE REMOVAL; HEART DEFECTS, CONGENITAL; MULTIVARIATE ANALYSIS; PROCEDURES;

EID: 84930379974     PISSN: 15475271     EISSN: 15563871     Source Type: Journal    
DOI: 10.1016/j.hrthm.2015.03.004     Document Type: Article
Times cited : (32)

References (22)
  • 3
    • 77956523973 scopus 로고    scopus 로고
    • Selective-site pacing in paediatric patients: Use of the SelectSecure System and risk of vein occlusion
    • F. Gabbarini, and G. Agnoletti Selective-site pacing in paediatric patients: use of the SelectSecure System and risk of vein occlusion Europace 12 2010 1286 1289
    • (2010) Europace , vol.12 , pp. 1286-1289
    • Gabbarini, F.1    Agnoletti, G.2
  • 5
    • 84861639906 scopus 로고    scopus 로고
    • EHRA. Current practice in transvenous lead extraction: A European Heart Rhythm Association EP Network Survey
    • M.G. Bongiorni, C. Blomstrom-Lundqvist, C. Kennergren, N. Dagres, L. Pison, J.H. Svendsen, A. Auricchio Scientific Initiative Committee EHRA. Current practice in transvenous lead extraction: a European Heart Rhythm Association EP Network Survey Europace 14 2012 783 786
    • (2012) Europace , vol.14 , pp. 783-786
    • Bongiorni, M.G.1    Blomstrom-Lundqvist, C.2    Kennergren, C.3    Dagres, N.4    Pison, L.5    Svendsen, J.H.6    Auricchio, A.7
  • 8
    • 34250701748 scopus 로고    scopus 로고
    • Noncatheter-based delivery of a single-chamber lumenless pacing lead in small children
    • D. Kenny, and K.P. Walsh Noncatheter-based delivery of a single-chamber lumenless pacing lead in small children Pacing Clin Electrophysiol 30 2007 834 838
    • (2007) Pacing Clin Electrophysiol , vol.30 , pp. 834-838
    • Kenny, D.1    Walsh, K.P.2
  • 9
    • 78650142720 scopus 로고    scopus 로고
    • Performance of the lumenless 4.1-Fr diameter pacing lead implanted at alternative pacing sites in congenital heart: A chronic 5-year comparison
    • A. Khan, K. Zelin, and P.P. Karpawich Performance of the lumenless 4.1-Fr diameter pacing lead implanted at alternative pacing sites in congenital heart: a chronic 5-year comparison Pacing Clin Electrophysiol 33 2010 1467 1474
    • (2010) Pacing Clin Electrophysiol , vol.33 , pp. 1467-1474
    • Khan, A.1    Zelin, K.2    Karpawich, P.P.3
  • 10
    • 33747116031 scopus 로고    scopus 로고
    • Worldwide SelectSecure Clinical Investigators. Multi-center clinical experience with a lumenless, catheter-delivered, bipolar, permanent pacemaker lead: Implant safety and electrical performance
    • M.D. Gammage, R.A. Lieberman, R. Yee, A.S. Manolis, S.J. Compton, C. Khazen, K. Schaaf, K.A. Oleson, and G.H. Crossley Worldwide SelectSecure Clinical Investigators. Multi-center clinical experience with a lumenless, catheter-delivered, bipolar, permanent pacemaker lead: implant safety and electrical performance Pacing Clin Electrophysiol 29 2006 858 865
    • (2006) Pacing Clin Electrophysiol , vol.29 , pp. 858-865
    • Gammage, M.D.1    Lieberman, R.A.2    Yee, R.3    Manolis, A.S.4    Compton, S.J.5    Khazen, C.6    Schaaf, K.7    Oleson, K.A.8    Crossley, G.H.9
  • 11
    • 34250726688 scopus 로고    scopus 로고
    • Implantation of SelectSecure leads in children
    • V. Tuzcu Implantation of SelectSecure leads in children Pacing Clin Electrophysiol 30 2007 831 833
    • (2007) Pacing Clin Electrophysiol , vol.30 , pp. 831-833
    • Tuzcu, V.1
  • 12
    • 84879322638 scopus 로고    scopus 로고
    • Multi-institutional study of implantable defibrillator lead performance in children and young adults: Results of the Pediatric Lead Extractability and Survival Evaluation (PLEASE) study
    • J. Atallah, C.C. Erickson, and F. Cecchin Multi-institutional study of implantable defibrillator lead performance in children and young adults: results of the Pediatric Lead Extractability and Survival Evaluation (PLEASE) study Circulation 127 2013 2393 2402
    • (2013) Circulation , vol.127 , pp. 2393-2402
    • Atallah, J.1    Erickson, C.C.2    Cecchin, F.3
  • 14
    • 77749323179 scopus 로고    scopus 로고
    • Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction
    • R.G. Hauser, W.T. Katsiyiannis, C.C. Gornick, A.K. Almquist, and L.M. Kallinen Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction Europace 12 2010 395 401
    • (2010) Europace , vol.12 , pp. 395-401
    • Hauser, R.G.1    Katsiyiannis, W.T.2    Gornick, C.C.3    Almquist, A.K.4    Kallinen, L.M.5
  • 15
    • 77957242468 scopus 로고    scopus 로고
    • Cardiac pacing in infants and children
    • K.A. McLeod Cardiac pacing in infants and children Heart 96 2010 1502 1508
    • (2010) Heart , vol.96 , pp. 1502-1508
    • McLeod, K.A.1
  • 16
    • 38449085796 scopus 로고    scopus 로고
    • Practical aspects of implantable defibrillator therapy in patients with congenital heart disease
    • E.P. Walsh Practical aspects of implantable defibrillator therapy in patients with congenital heart disease Pacing Clin Electrophysiol 31 Suppl 1 2008 S38 S40
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. S38-S40
    • Walsh, E.P.1
  • 17
    • 84883368948 scopus 로고    scopus 로고
    • Cardiac pacing in paediatric patients with congenital heart defects: Transvenous or epicardial?
    • M.S. Silvetti, F. Drago, D. Di Carlo, S. Placidi, G. Brancaccio, and A. Carotti Cardiac pacing in paediatric patients with congenital heart defects: transvenous or epicardial? Europace 15 2013 1280 1286
    • (2013) Europace , vol.15 , pp. 1280-1286
    • Silvetti, M.S.1    Drago, F.2    Di Carlo, D.3    Placidi, S.4    Brancaccio, G.5    Carotti, A.6
  • 18
    • 84898929814 scopus 로고    scopus 로고
    • Clinical predictors of adverse patient outcomes in an experience of more than 5000 chronic endovascular pacemaker and defibrillator lead extractions
    • M.P. Brunner, E.M. Cronin, and V.E. Duarte Clinical predictors of adverse patient outcomes in an experience of more than 5000 chronic endovascular pacemaker and defibrillator lead extractions Heart Rhythm 11 2014 799 805
    • (2014) Heart Rhythm , vol.11 , pp. 799-805
    • Brunner, M.P.1    Cronin, E.M.2    Duarte, V.E.3
  • 21
    • 84930382897 scopus 로고    scopus 로고
    • Improved atrioventricular valve integrity with use of the newer 4.1 French diameter pacing lead in the young with and without congenital heart
    • A. Bharmanee, K. Zelin, H. Singh, and P. Karpawich Improved atrioventricular valve integrity with use of the newer 4.1 French diameter pacing lead in the young with and without congenital heart Circulation 128 2013 A12056
    • (2013) Circulation , vol.128 , pp. A12056
    • Bharmanee, A.1    Zelin, K.2    Singh, H.3    Karpawich, P.4
  • 22
    • 84939884490 scopus 로고    scopus 로고
    • Cumulative radiation exposure in pediatric patients with congenital heart disease
    • M.A. Walsh, M. Noga, and J. Rutledge Cumulative radiation exposure in pediatric patients with congenital heart disease Pediatr Cardiology 36 2014 289 294
    • (2014) Pediatr Cardiology , vol.36 , pp. 289-294
    • Walsh, M.A.1    Noga, M.2    Rutledge, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.