메뉴 건너뛰기




Volumn 38, Issue 1, 2015, Pages 42-47

Lumenless pacing leads: Performance and extraction in pediatrics and congenital heart disease

Author keywords

pacing; pediatrics

Indexed keywords

ARTICLE; BODY WEIGHT; CONGENITAL HEART DISEASE; DEVICE REMOVAL; FOLLOW UP; HEART PACING; HUMAN; IMPLANT; MAJOR CLINICAL STUDY; MEDICAL DEVICE COMPLICATION; PEDIATRIC HOSPITAL; PEDIATRICS; ADOLESCENT; ADULT; ARTIFICIAL HEART PACEMAKER; CHILD; CONGENITAL HEART MALFORMATION; EQUIPMENT DESIGN; INFANT; MIDDLE AGED; PRESCHOOL CHILD; RETROSPECTIVE STUDY; YOUNG ADULT;

EID: 84920837626     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/pace.12508     Document Type: Article
Times cited : (29)

References (11)
  • 1
    • 33750970326 scopus 로고    scopus 로고
    • Pacemakers and implantable cardioverter-defibrillators in pediatric patients
    • Silka MJ, Bar-Cohen Y,. Pacemakers and implantable cardioverter-defibrillators in pediatric patients. Heart Rhythm 2006; 3: 1360-1366.
    • (2006) Heart Rhythm , vol.3 , pp. 1360-1366
    • Silka, M.J.1    Bar-Cohen, Y.2
  • 3
    • 78650142720 scopus 로고    scopus 로고
    • Performance of the lumenless 4.1-Fr diameter pacing lead implanted at alternative pacing sites in congenital heart: A chronic 5-year comparison
    • Khan A, Zelin K, Karpawich PP,. Performance of the lumenless 4.1-Fr diameter pacing lead implanted at alternative pacing sites in congenital heart: A chronic 5-year comparison. Pacing Clin Electrophysiol 2010; 33: 1467-1474.
    • (2010) Pacing Clin Electrophysiol , vol.33 , pp. 1467-1474
    • Khan, A.1    Zelin, K.2    Karpawich, P.P.3
  • 4
    • 33747116031 scopus 로고    scopus 로고
    • Multi-center clinical experience with a lumenless, catheter-delivered, bipolar, permanent pacemaker lead: Implant safety and electrical performance
    • Gammage MD, Lieberman RA, Yee R, Manolis AS, Compton SJ, Khazen C, Schaaf K, et al. Multi-center clinical experience with a lumenless, catheter-delivered, bipolar, permanent pacemaker lead: Implant safety and electrical performance. Pacing Clin Electrophysiol 2006; 29: 858-865.
    • (2006) Pacing Clin Electrophysiol , vol.29 , pp. 858-865
    • Gammage, M.D.1    Lieberman, R.A.2    Yee, R.3    Manolis, A.S.4    Compton, S.J.5    Khazen, C.6    Schaaf, K.7
  • 6
    • 34250726688 scopus 로고    scopus 로고
    • Implantation of Select Secure leads in children
    • Tuzcu V,. Implantation of Select Secure leads in children. Pacing Clin Electrophysiol 2007; 30: 831-833.
    • (2007) Pacing Clin Electrophysiol , vol.30 , pp. 831-833
    • Tuzcu, V.1
  • 7
    • 34250701748 scopus 로고    scopus 로고
    • Noncatheter-based delivery of a single-chamber lumenless pacing lead in small children
    • Kenny D, Walsh KP,. Noncatheter-based delivery of a single-chamber lumenless pacing lead in small children. Pacing Clin Electrophysiol 2007; 30: 834-838.
    • (2007) Pacing Clin Electrophysiol , vol.30 , pp. 834-838
    • Kenny, D.1    Walsh, K.P.2
  • 10
    • 77956523973 scopus 로고    scopus 로고
    • Selective-site pacing in paediatric patients: Use of the Select Secure System and risk of vein occlusion
    • Gabbarini F, Agnoletti G,. Selective-site pacing in paediatric patients: Use of the Select Secure System and risk of vein occlusion. Europace 2010; 12: 1286-1289.
    • (2010) Europace , vol.12 , pp. 1286-1289
    • Gabbarini, F.1    Agnoletti, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.