메뉴 건너뛰기




Volumn 5, Issue 2, 2012, Pages 252-257

Long-term mortality after transvenous lead extraction

Author keywords

Cardiovascular implantable electronic device; Lead extraction; Lead management; Mortality

Indexed keywords

CREATININE;

EID: 84862264422     PISSN: 19413149     EISSN: 19413084     Source Type: Journal    
DOI: 10.1161/CIRCEP.111.965277     Document Type: Article
Times cited : (149)

References (10)
  • 3
    • 77749323179 scopus 로고    scopus 로고
    • Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction
    • Hauser RG, Katsiyiannis WT, Gornick CC, Almquist AK, Kallinen LM. Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction. Europace. 2010; 12:395-401.
    • (2010) Europace. , vol.12 , pp. 395-401
    • Hauser, R.G.1    Katsiyiannis, W.T.2    Gornick, C.C.3    Almquist, A.K.4    Kallinen, L.M.5
  • 4
    • 40849114529 scopus 로고    scopus 로고
    • Large, single-center, single-operator experience with transvenous lead extraction: Outcomes and changing indications
    • Jones SO, Eckart RE, Albert CM, Epstein LM. Large, single-center, single-operator experience with transvenous lead extraction: outcomes and changing indications. Heart Rhythm. 2008;5:520-525.
    • (2008) Heart Rhythm. , vol.5 , pp. 520-525
    • Jones, S.O.1    Eckart, R.E.2    Albert, C.M.3    Epstein, L.M.4
  • 5
    • 57349111725 scopus 로고    scopus 로고
    • Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: High success rate and safety in more than 2000 leads
    • Bongiorni MG, Soldati E, Zucchelli G, Di Cori A, Segreti L, De Lucia R, Solarino G, Balbarini A, Marzilli M, Mariani M. Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leads. Eur Heart J. 2008; 29:2886-2893.
    • (2008) Eur Heart J. , vol.29 , pp. 2886-2893
    • Bongiorni, M.G.1    Soldati, E.2    Zucchelli, G.3    Di Cori, A.4    Segreti, L.5    De Lucia, R.6    Solarino, G.7    Balbarini, A.8    Marzilli, M.9    Mariani, M.10
  • 6
    • 66749148454 scopus 로고    scopus 로고
    • A single-centre experience of over one thousand lead extractions
    • Kennergren C, Bjurman C, Wiklund R, Gabel J. A single-centre experience of over one thousand lead extractions. Europace. 2009;11: 612-617.
    • (2009) Europace. , vol.11 , pp. 612-617
    • Kennergren, C.1    Bjurman, C.2    Wiklund, R.3    Gabel, J.4
  • 9
    • 78651316657 scopus 로고    scopus 로고
    • High mid-term mortality following successful lead extraction for infection
    • Henrikson CA, Zhang K, Brinker JA. High mid-term mortality following successful lead extraction for infection. Pacing Clin Electrophysiol. 2011; 34:32-36.
    • (2011) Pacing Clin Electrophysiol. , vol.34 , pp. 32-36
    • Henrikson, C.A.1    Zhang, K.2    Brinker, J.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.