메뉴 건너뛰기




Volumn 29, Issue 3, 2015, Pages 710-714

Reversal of heparin after cardiac surgery: Protamine titration using a statistical model

Author keywords

cardiac surgery; cardiopulmonary bypass; heparin; point of care testing; protamine; statistical modeling

Indexed keywords

HEPARIN; PROTAMINE; HEPARIN ANTAGONIST;

EID: 84930082457     PISSN: 10530770     EISSN: 15328422     Source Type: Journal    
DOI: 10.1053/j.jvca.2014.12.006     Document Type: Article
Times cited : (16)

References (16)
  • 1
    • 0742272009 scopus 로고    scopus 로고
    • Comparison of structured use of routine laboratory tests or near-patient assessment with clinical judgement in the management of bleeding after cardiac surgery
    • M.S. Avidan, E.L. Alcock, and J. Da Fonseca Comparison of structured use of routine laboratory tests or near-patient assessment with clinical judgement in the management of bleeding after cardiac surgery Br J Anaesth 92 2004 178 186
    • (2004) Br J Anaesth , vol.92 , pp. 178-186
    • Avidan, M.S.1    Alcock, E.L.2    Da Fonseca, J.3
  • 2
    • 33746752738 scopus 로고    scopus 로고
    • Does use of the Hepcon point-of-care coagulation monitor to optimise heparin and protamine dosage for cardiopulmonary bypass decrease bleeding and blood and blood product requirements in adult patients undergoing cardiac surgery?
    • K.A. Aziz, O. Masood, and J.A. Hoschtitzky Does use of the Hepcon point-of-care coagulation monitor to optimise heparin and protamine dosage for cardiopulmonary bypass decrease bleeding and blood and blood product requirements in adult patients undergoing cardiac surgery? Interact Cardiovasc Thorac Surg 5 2006 469 482
    • (2006) Interact Cardiovasc Thorac Surg , vol.5 , pp. 469-482
    • Aziz, K.A.1    Masood, O.2    Hoschtitzky, J.A.3
  • 3
    • 0030888878 scopus 로고    scopus 로고
    • Whole blood heparin concentration measurements by automated protamine titration agree with plasma anti-Xa measurements
    • G.J. Despotis, J.H. Joist, and L.T. Goodnough Whole blood heparin concentration measurements by automated protamine titration agree with plasma anti-Xa measurements J Thorac Cardiovasc Surg 113 1997 611 613
    • (1997) J Thorac Cardiovasc Surg , vol.113 , pp. 611-613
    • Despotis, G.J.1    Joist, J.H.2    Goodnough, L.T.3
  • 4
    • 0034029186 scopus 로고    scopus 로고
    • Hemostatic effects of low-dose protamine following cardiopulmonary bypass
    • T. Miyashita, T. Nakajima, and Y. Hayashi Hemostatic effects of low-dose protamine following cardiopulmonary bypass Am J Hematol 64 2000 112 115
    • (2000) Am J Hematol , vol.64 , pp. 112-115
    • Miyashita, T.1    Nakajima, T.2    Hayashi, Y.3
  • 5
    • 84896404937 scopus 로고    scopus 로고
    • Individualized heparin and protamine management improves rotational thromboelastometric parameters and postoperative hemostasis in valve surgery
    • A.B. Vonk, D. Veerhoek, and C.E. van den Brom Individualized heparin and protamine management improves rotational thromboelastometric parameters and postoperative hemostasis in valve surgery J Cardiothorac Vasc Anesth 28 2014 235 241
    • (2014) J Cardiothorac Vasc Anesth , vol.28 , pp. 235-241
    • Vonk, A.B.1    Veerhoek, D.2    Van Den Brom, C.E.3
  • 6
    • 72749100230 scopus 로고    scopus 로고
    • Static blood-flow control during cardiopulmonary bypass is a compromise of oxygen delivery
    • S. Svenmarker, S. Häggmark, and M. Hultin Static blood-flow control during cardiopulmonary bypass is a compromise of oxygen delivery Eur J Cardiothorac Surg 37 2010 218 222
    • (2010) Eur J Cardiothorac Surg , vol.37 , pp. 218-222
    • Svenmarker, S.1    Häggmark, S.2    Hultin, M.3
  • 7
    • 84894065711 scopus 로고    scopus 로고
    • Method to calculate the protamine dose necessary for reversal of heparin as a function of activated clotting time in patients undergoing cardiac surgery
    • J. Suárez Cuenca, P. Gayoso Diz, and F. Gude Sampedro Method to calculate the protamine dose necessary for reversal of heparin as a function of activated clotting time in patients undergoing cardiac surgery J Extra Corpor Technol 45 2013 235 241
    • (2013) J Extra Corpor Technol , vol.45 , pp. 235-241
    • Suárez Cuenca, J.1    Gayoso Diz, P.2    Gude Sampedro, F.3
  • 8
    • 0000719057 scopus 로고
    • Prediction of blood volume in normal human adults
    • S.B. Nadler, J.H. Hidalgo, and T. Bloch Prediction of blood volume in normal human adults Surgery 51 1962 224 232
    • (1962) Surgery , vol.51 , pp. 224-232
    • Nadler, S.B.1    Hidalgo, J.H.2    Bloch, T.3
  • 9
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • J.M. Bland, and D.G. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 1986 307 310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 0034111137 scopus 로고    scopus 로고
    • Management of anticoagulation and its reversal during paediatric cardiopulmonary bypass: A review of current UK practice
    • M. Codispoti, and P.S. Mankad Management of anticoagulation and its reversal during paediatric cardiopulmonary bypass: A review of current UK practice Perfusion 15 2000 191 201
    • (2000) Perfusion , vol.15 , pp. 191-201
    • Codispoti, M.1    Mankad, P.S.2
  • 11
    • 0000685584 scopus 로고
    • The neutralization of heparin by protamine in extracorporeal circulation
    • F. Gerbode, R. Hurt, and J.J. Osborn The neutralization of heparin by protamine in extracorporeal circulation J Thorac Surg 32 1956 612 619
    • (1956) J Thorac Surg , vol.32 , pp. 612-619
    • Gerbode, F.1    Hurt, R.2    Osborn, J.J.3
  • 12
    • 84876687684 scopus 로고    scopus 로고
    • Point-of-care assessment of hypothermia and protamine-induced platelet dysfunction with multiple electrode aggregometry (Multiplate®) in patients undergoing cardiopulmonary bypass
    • E. Ortmann, A.A. Klein, and L.D. Sharples Point-of-care assessment of hypothermia and protamine-induced platelet dysfunction with multiple electrode aggregometry (Multiplate®) in patients undergoing cardiopulmonary bypass Anesth Analg 116 2013 533 540
    • (2013) Anesth Analg , vol.116 , pp. 533-540
    • Ortmann, E.1    Klein, A.A.2    Sharples, L.D.3
  • 13
    • 82255196088 scopus 로고    scopus 로고
    • Are the point-of-care diagnostics MULTIPLATE and ROTEM valid in the setting of high concentrations of heparin and its reversal with protamine?
    • R. Gertler, G. Wiesner, and P. Tassani-Prell Are the point-of-care diagnostics MULTIPLATE and ROTEM valid in the setting of high concentrations of heparin and its reversal with protamine? J Cardiothorac Vasc Anesth 25 2011 981 986
    • (2011) J Cardiothorac Vasc Anesth , vol.25 , pp. 981-986
    • Gertler, R.1    Wiesner, G.2    Tassani-Prell, P.3
  • 14
    • 0029905856 scopus 로고    scopus 로고
    • The effects of thrombocytopenia on the activated coagulation time
    • T. Ammar, C.F. Fisher, and K. Sarier The effects of thrombocytopenia on the activated coagulation time Anesth Analg 83 1996 1185 1188
    • (1996) Anesth Analg , vol.83 , pp. 1185-1188
    • Ammar, T.1    Fisher, C.F.2    Sarier, K.3
  • 15
    • 0016737841 scopus 로고
    • Heparin therapy during extracorporeal circulation. II. The use of a dose-response curve to individualize heparin and protamine dosage
    • B.S. Bull, W.M. Huse, and F.S. Brauer Heparin therapy during extracorporeal circulation. II. The use of a dose-response curve to individualize heparin and protamine dosage J Thorac Cardiovasc Surg 69 1975 685 689
    • (1975) J Thorac Cardiovasc Surg , vol.69 , pp. 685-689
    • Bull, B.S.1    Huse, W.M.2    Brauer, F.S.3
  • 16
    • 84905728619 scopus 로고    scopus 로고
    • Reappearance of circulating heparin in whole blood heparin concentration-based management does not correlate with postoperative bleeding after cardiac surgery
    • J. Ichikawa, M. Kodaka, and K. Nishiyama Reappearance of circulating heparin in whole blood heparin concentration-based management does not correlate with postoperative bleeding after cardiac surgery J Cardiothorac Vasc Anesth 28 2014 1015 1019
    • (2014) J Cardiothorac Vasc Anesth , vol.28 , pp. 1015-1019
    • Ichikawa, J.1    Kodaka, M.2    Nishiyama, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.