메뉴 건너뛰기




Volumn 5, Issue 4, 2006, Pages 469-482

Does use of the Hepcon® point-of-care coagulation monitor to optimise heparin and protamine dosage for cardiopulmonary bypass decrease bleeding and blood and blood product requirements in adult patients undergoing cardiac surgery?

Author keywords

Blood products; Cardiac surgery; Cardiopulmonary bypass; Coagulation management; Heparin; Protamine

Indexed keywords

HEPARIN; PROTAMINE;

EID: 33746752738     PISSN: 15699293     EISSN: 15699293     Source Type: Journal    
DOI: 10.1510/icvts.2006.133785     Document Type: Article
Times cited : (19)

References (15)
  • 2
    • 0242491042 scopus 로고    scopus 로고
    • Heparin monitoring during cardiac surgery. Part 1: Validation of whole blood heparin concentration and activated clotting time
    • Raymond PD, Ray MJ, Callen SN, Marsh NA. Heparin monitoring during cardiac surgery. Part 1: validation of whole blood heparin concentration and activated clotting time. Perfusion 2003;18:269-276.
    • (2003) Perfusion , vol.18 , pp. 269-276
    • Raymond, P.D.1    Ray, M.J.2    Callen, S.N.3    Marsh, N.A.4
  • 3
    • 0031052490 scopus 로고    scopus 로고
    • Heparin detection by the activated coagulation time: A comparison of the sensitivity of coagulation tests and heparin assays
    • Murray DJ, Brosnahan WJ, Pennell B, Kapalanski D, Weiler JM, Olson J. Heparin detection by the activated coagulation time: a comparison of the sensitivity of coagulation tests and heparin assays. J Cardiothorac Vasc Anesth 1997;11:24-28.
    • (1997) J Cardiothorac Vasc Anesth , vol.11 , pp. 24-28
    • Murray, D.J.1    Brosnahan, W.J.2    Pennell, B.3    Kapalanski, D.4    Weiler, J.M.5    Olson, J.6
  • 8
    • 3142701336 scopus 로고    scopus 로고
    • Comparison of heparin administration using the Rapidpoint Coag and Hepcon HMS
    • Newsome J, Stipanovich K, Flaherty S. Comparison of heparin administration using the Rapidpoint Coag and Hepcon HMS. J Extra-Corporeal Technol 2004;36:139-144.
    • (2004) J Extra-Corporeal Technol , vol.36 , pp. 139-144
    • Newsome, J.1    Stipanovich, K.2    Flaherty, S.3
  • 10
    • 0032753732 scopus 로고    scopus 로고
    • Haemostasis management by use of the HepconyHMS®: Increased bleeding without increased need for blood transfusion
    • Beholz S, Grubitzsch H, Bergmann B, Wollert H-G, Eckel L. Haemostasis management by use of the HepconyHMS®: increased bleeding without increased need for blood transfusion. Thorac Cardiovasc Surgeon 1999;47:322-327.
    • (1999) Thorac Cardiovasc Surgeon , vol.47 , pp. 322-327
    • Beholz, S.1    Grubitzsch, H.2    Bergmann, B.3    Wollert, H.-G.4    Eckel, L.5
  • 12
    • 0036790231 scopus 로고    scopus 로고
    • Hemostatic activation and inflammatory response during cardiopulmonary bypass: Impact of heparin management
    • Koster A, Fischer T, Praus M, Haberzettl H, Kuebler WM, Hetzer R, Kuppe H. Hemostatic activation and inflammatory response during cardiopulmonary bypass: impact of heparin management. Anesthesiology 2002;97:837-841.
    • (2002) Anesthesiology , vol.97 , pp. 837-841
    • Koster, A.1    Fischer, T.2    Praus, M.3    Haberzettl, H.4    Kuebler, W.M.5    Hetzer, R.6    Kuppe, H.7
  • 13
    • 0742272009 scopus 로고    scopus 로고
    • Comparison of structured use of routine laboratory tests or near-patient assessment with clinical judgement in the management of bleeding after cardiac surgery
    • Avidan MS, Alcock EL, Da Fonseca J, Ponte J, Desai JB, Despotis GJ, Hunt BJ. Comparison of structured use of routine laboratory tests or near-patient assessment with clinical judgement in the management of bleeding after cardiac surgery. Br J Anaesth 2004;92:178-186.
    • (2004) Br J Anaesth , vol.92 , pp. 178-186
    • Avidan, M.S.1    Alcock, E.L.2    Da Fonseca, J.3    Ponte, J.4    Desai, J.B.5    Despotis, G.J.6    Hunt, B.J.7
  • 14
    • 0035099811 scopus 로고    scopus 로고
    • A four-year experience with patient individualized heparin and protamine dosing using the Hemochron RxDx system
    • Bennett KM, Briggins D, Zucker M, LaDuca F. A four-year experience with patient individualized heparin and protamine dosing using the Hemochron RxDx system. J Extra-Corporeal Technol 2001;33:19-22.
    • (2001) J Extra-Corporeal Technol , vol.33 , pp. 19-22
    • Bennett, K.M.1    Briggins, D.2    Zucker, M.3    LaDuca, F.4
  • 15
    • 0031918371 scopus 로고    scopus 로고
    • Heparin and protamine titration do not improve haemostasis in cardiac surgical patients
    • Shore-Lesserson L, Reich DL, DePerio M. Heparin and protamine titration do not improve haemostasis in cardiac surgical patients. Can J Anaesth 1998;45:10-18.
    • (1998) Can J Anaesth , vol.45 , pp. 10-18
    • Shore-Lesserson, L.1    Reich, D.L.2    DePerio, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.