메뉴 건너뛰기




Volumn 42, Issue 5, 2015, Pages 2638-2647

Visibility and artifacts of gold fiducial markers used for image guided radiation therapy of pancreatic cancer on MRI

Author keywords

fiducial markers; image artifacts; image guided radiation therapy; MRI; pancreatic cancer

Indexed keywords

COMPUTERIZED TOMOGRAPHY; DISEASES; GOLD; IMAGE ENHANCEMENT; MAGNETISM; PHANTOMS; RADIOTHERAPY; TUMORS; VISIBILITY;

EID: 84930011293     PISSN: 00942405     EISSN: 24734209     Source Type: Journal    
DOI: 10.1118/1.4918753     Document Type: Article
Times cited : (41)

References (36)
  • 2
    • 84907189717 scopus 로고    scopus 로고
    • Differences in respiratory-induced pancreatic tumor motion between 4D treatment planning CT and daily cone beam CT, measured using intratumoral fiducials
    • E. Lens, A. van der Horst, P. S. Kroon, J. E. van Hooft, R. Dávila Fajardo, P. Fockens, G. van Tienhoven, and A. Bel, "Differences in respiratory-induced pancreatic tumor motion between 4D treatment planning CT and daily cone beam CT, measured using intratumoral fiducials," Acta Oncol. 53, 1257-1264 (2014). 10.3109/0284186x.2014.905699
    • (2014) Acta Oncol. , vol.53 , pp. 1257-1264
    • Lens, E.1    Van Der Horst, A.2    Kroon, P.S.3    Van Hooft, J.E.4    Dávila Fajardo, R.5    Fockens, P.6    Van Tienhoven, G.7    Bel, A.8
  • 3
    • 84864143985 scopus 로고    scopus 로고
    • Assessment of the technical performance of the flexible 19-gauge EUS-FNA needle
    • S. Varadarajulu, J. Y. Bang, and S. Hebert-Magee, "Assessment of the technical performance of the flexible 19-gauge EUS-FNA needle," Gastrointest. Endosc. 76, 336-343 (2012). 10.1016/j.gie.2012.04.455
    • (2012) Gastrointest. Endosc. , vol.76 , pp. 336-343
    • Varadarajulu, S.1    Bang, J.Y.2    Hebert-Magee, S.3
  • 8
    • 34247395789 scopus 로고    scopus 로고
    • Early invasive cervical cancer: Tumor delineation by magnetic resonance imaging, computed tomography, and clinical examination, verified by pathologic results, in the ACRIN 6651/GOG 183 intergroup study
    • D. G. Mitchell, B. Snyder, F. Coakley, C. Reinhold, G. Thomas, M. Amendola, L. H. Schwartz, P. Woodward, H. Pannu, and H. Hricak, "Early invasive cervical cancer: Tumor delineation by magnetic resonance imaging, computed tomography, and clinical examination, verified by pathologic results, in the ACRIN 6651/GOG 183 intergroup study," J. Clin. Oncol. 24, 5687-5694 (2006). 10.1200/JCO.2006.07.4799
    • (2006) J. Clin. Oncol. , vol.24 , pp. 5687-5694
    • Mitchell, D.G.1    Snyder, B.2    Coakley, F.3    Reinhold, C.4    Thomas, G.5    Amendola, M.6    Schwartz, L.H.7    Woodward, P.8    Pannu, H.9    Hricak, H.10
  • 9
    • 33846925354 scopus 로고    scopus 로고
    • MRI of the pancreas: Tumours and tumour-simulating processes
    • W. Schima, "MRI of the pancreas: Tumours and tumour-simulating processes," Cancer Imaging 6, 199-203 (2006). 10.1102/1470-7330.2006.0035
    • (2006) Cancer Imaging , vol.6 , pp. 199-203
    • Schima, W.1
  • 11
  • 12
    • 84879409527 scopus 로고    scopus 로고
    • Commissioning of MRI-only based treatment planning procedure for external beam radiotherapy of prostate
    • M. Kapanen, J. Collan, A. Beule, T. Seppälä, K. Saarilahti, and M. Tenhunen, "Commissioning of MRI-only based treatment planning procedure for external beam radiotherapy of prostate," Magn. Reson. Med. 70, 127-135 (2013). 10.1002/mrm.24459
    • (2013) Magn. Reson. Med. , vol.70 , pp. 127-135
    • Kapanen, M.1    Collan, J.2    Beule, A.3    Seppälä, T.4    Saarilahti, K.5    Tenhunen, M.6
  • 14
    • 84954521610 scopus 로고    scopus 로고
    • Qualitative evaluation of fiducial markers for radiotherapy imaging
    • M. F. Chan, G. N. Cohen, and J. O. Deasy, "Qualitative evaluation of fiducial markers for radiotherapy imaging," Technol. Cancer Res. Treat. 1-7 (2014). 10.1177/1533034614547447
    • (2014) Technol. Cancer Res. Treat. , pp. 1-7
    • Chan, M.F.1    Cohen, G.N.2    Deasy, J.O.3
  • 16
    • 79960519073 scopus 로고    scopus 로고
    • Intensity profile based measurement of prostate gold markers influence on 1.5 and 3T diffusion-weighted MR images
    • S. Rylander, S. Thörnqvist, S. Haack, E. M. Pedersen, and L. P. Muren, "Intensity profile based measurement of prostate gold markers influence on 1.5 and 3T diffusion-weighted MR images," Acta Oncol. 50, 866-872 (2011). 10.3109/0284186x.2011.590523
    • (2011) Acta Oncol. , vol.50 , pp. 866-872
    • Rylander, S.1    Thörnqvist, S.2    Haack, S.3    Pedersen, E.M.4    Muren, L.P.5
  • 17
    • 0030013529 scopus 로고    scopus 로고
    • The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds
    • J. F. Schenck, "The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds," Med. Phys. 23, 815-850 (1996). 10.1118/1.597854
    • (1996) Med. Phys. , vol.23 , pp. 815-850
    • Schenck, J.F.1
  • 20
    • 84930005743 scopus 로고    scopus 로고
    • Spatial accuracy and visibility studies of a MRI compatible fiducial marker [ASTRO abstract 3382]
    • P. Wersall, A. Hartwig, E. Castellanos, F. Labruto, and A. Tilikidis, "Spatial accuracy and visibility studies of a MRI compatible fiducial marker [ASTRO abstract 3382]," Int. J. Radiat. Oncol., Biol., Phys. 84 (Suppl.), S737-S738 (2012). 10.1016/j.ijrobp.2012.07.1973
    • (2012) Int. J. Radiat. Oncol., Biol., Phys. , vol.84 , pp. S737-S738
    • Wersall, P.1    Hartwig, A.2    Castellanos, E.3    Labruto, F.4    Tilikidis, A.5
  • 23
    • 0037059094 scopus 로고    scopus 로고
    • Fast two-dimensional phase-unwrapping algorithm based on sorting by reliability following a noncontinuous path
    • M. A. Herráez, D. R. Burton, M. J. Lalor, and M. A. Gdeisat, "Fast two-dimensional phase-unwrapping algorithm based on sorting by reliability following a noncontinuous path," Appl. Opt. 41, 7437-7444 (2002). 10.1364/ao.41.007437
    • (2002) Appl. Opt. , vol.41 , pp. 7437-7444
    • Herráez, M.A.1    Burton, D.R.2    Lalor, M.J.3    Gdeisat, M.A.4
  • 26
    • 18044367901 scopus 로고    scopus 로고
    • RF artifacts caused by metallic implants or instruments which get more prominent at 3 T: An in vitro study
    • U. A. Lauer, A. Berger, and F. Schick, "RF artifacts caused by metallic implants or instruments which get more prominent at 3 T: An in vitro study," Magn. Reson. Imaging 23, 493-499 (2005). 10.1016/j.mri.2005.02.012
    • (2005) Magn. Reson. Imaging , vol.23 , pp. 493-499
    • Lauer, U.A.1    Berger, A.2    Schick, F.3
  • 27
    • 31044434512 scopus 로고    scopus 로고
    • Effects on MRI due to altered rf polarization near conductive implants or instruments
    • H. Graf, G. Steidle, P. Martirosian, U. A. Lauer, and F. Schick, "Effects on MRI due to altered rf polarization near conductive implants or instruments," Med. Phys. 33, 124-127 (2006). 10.1118/1.2132571
    • (2006) Med. Phys. , vol.33 , pp. 124-127
    • Graf, H.1    Steidle, G.2    Martirosian, P.3    Lauer, U.A.4    Schick, F.5
  • 28
    • 84912557945 scopus 로고    scopus 로고
    • Mapping B1-induced eddy current effects near metallic structures in MR images: A comparison of simulation and experiment
    • S. Vashaee, F. Goora, M. M. Britton, B. Newling, and B. J. Balcom, "Mapping B1-induced eddy current effects near metallic structures in MR images: A comparison of simulation and experiment," J. Magn. Reson. 250, 17-24 (2015). 10.1016/j.jmr.2014.10.016
    • (2015) J. Magn. Reson. , vol.250 , pp. 17-24
    • Vashaee, S.1    Goora, F.2    Britton, M.M.3    Newling, B.4    Balcom, B.J.5
  • 29
    • 84930008210 scopus 로고    scopus 로고
    • Impact of field strength and RF excitation on abdominal diffusion-weighted magnetic resonance imaging
    • P. Riffel, R. K. Rao, S. Haneder, M. Meyer, S. O. Schoenberg, and H. J. Michaely, "Impact of field strength and RF excitation on abdominal diffusion-weighted magnetic resonance imaging," World J. Radiol. 5, 334-344 (2013). 10.4329/wjr.v5.i9.334
    • (2013) World J. Radiol. , vol.5 , pp. 334-344
    • Riffel, P.1    Rao, R.K.2    Haneder, S.3    Meyer, M.4    Schoenberg, S.O.5    Michaely, H.J.6
  • 32
    • 84878594974 scopus 로고    scopus 로고
    • Novel applications of an injectable radiopaque hydrogel tissue marker for management of thoracic malignancies
    • L. de Souza Lawrence, E. Ford, C. Gilbert, L. Yarmus, A. Meneshian, D. Feller-Kopman, and R. Hales, "Novel applications of an injectable radiopaque hydrogel tissue marker for management of thoracic malignancies," Chest 143, 1635-1641 (2013). 10.1378/chest.12-1691
    • (2013) Chest , vol.143 , pp. 1635-1641
    • De Souza Lawrence, L.1    Ford, E.2    Gilbert, C.3    Yarmus, L.4    Meneshian, A.5    Feller-Kopman, D.6    Hales, R.7
  • 34
    • 34248231387 scopus 로고    scopus 로고
    • Clinical multishot DW-EPI through parallel imaging with considerations of susceptibility, motion, and noise
    • S. Skare, R. D. Newbould, D. B. Clayton, G. W. Albers, S. Nagle, and R. Bammer, "Clinical multishot DW-EPI through parallel imaging with considerations of susceptibility, motion, and noise," Magn. Reson. Med. 57, 881-890 (2007). 10.1002/mrm.21176
    • (2007) Magn. Reson. Med. , vol.57 , pp. 881-890
    • Skare, S.1    Newbould, R.D.2    Clayton, D.B.3    Albers, G.W.4    Nagle, S.5    Bammer, R.6
  • 35
    • 79954443670 scopus 로고    scopus 로고
    • Highly localized positive contrast of small paramagnetic objects using 3D center-out radial sampling with off-resonance reception
    • P. R. Seevinck, H. de Leeuw, C. Bos, and C. J. G. Bakker, "Highly localized positive contrast of small paramagnetic objects using 3D center-out radial sampling with off-resonance reception," Magn. Reson. Med. 65, 146-156 (2011). 10.1002/mrm.22594
    • (2011) Magn. Reson. Med. , vol.65 , pp. 146-156
    • Seevinck, P.R.1    De Leeuw, H.2    Bos, C.3    Bakker, C.J.G.4
  • 36
    • 84929995301 scopus 로고    scopus 로고
    • http://dx.doi.org/10.1118/1.4918753


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.